Digital Multimeter Guide Mastech M9803R

Similar documents
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

AutoRanging Digital MultiMeter

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

User's Guide. True RMS Industrial Multimeter

Model UT33A: OPERATING MANUAL Table of Contents (1)

Manual Ranging MultiMeter

HOW TO USE MULTIMETER. COMPILE BY: Dzulautotech

Model UT58A/B/C: OPERATING MANUAL

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

Model UT60A: OPERATING MANUAL. Table of Contents. Page

User Guide. Model Insulation Tester / Megohmmeter

UT202A Operating Manual. Contents

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Model UT201/202: OPERATING MANUAL. Table of Contents

Intelligent Digital Multimeters

What is a multimeter?

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Fundamentals of Signature Analysis

How To Use A Cdm250 Digital Multimeter

Dynatek 6080RS multimeter

Table of Contents. Page

Essential Electrical Concepts

The Basics of Digital Multimeters

Kirchhoff s Laws Physics Lab IX

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

Lab 3 - DC Circuits and Ohm s Law

Model UT71A/B OPERATING MANUAL

RC Circuits and The Oscilloscope Physics Lab X

ABCs of DMMs Multimeter features and functions explained Application Note

Using an Oscilloscope

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

Experiment 2 Diode Applications: Rectifiers

7 FUNCTION DIGITAL MULTIMETER

Lab E1: Introduction to Circuits

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

ECEN 1400, Introduction to Analog and Digital Electronics

RADIANT PLASMA 4700 Plasma Spark Generator

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Seven function digital multimeter

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

Owner s Manual & Safety Instructions

Loop Calibration and Maintenance

115C and 117C. True-rms Multimeters. Users Manual

5000V Graphical Megohmmeter Model 5070

Model 187 & 189. Users Manual. True RMS Multimeter

Electrical Fundamentals Module 3: Parallel Circuits

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

Transistor Amplifiers

Fluke 3000 FC Series Test Tools Technical Data


Renewable Energy Monitor User Manual And Software Reference Guide. (979)

10 Multimeter. Users Manual

Robot Board Sub-System Testing. Abstract. Introduction and Theory. Equipment. Procedures. EE 101 Spring 2006 Date: Lab Section # Lab #6

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Parallel Plate Capacitor

Electrical Safety Tester

High voltage power supply (1 to 20 KV)

Electrical Resonance

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

Inductors in AC Circuits

Rectifier circuits & DC power supplies

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter

Circuit Analyses. Laboration 1 how to measure Current and Voltage and Resistance

TOOLS DIAGNOSTIC. The information presented in this chapter is organized as follows: Quick reference tables. Detailed product specifications.

School of Electrical and Information Engineering. The Remote Laboratory System. Electrical and Information Engineering Project 2006.

Talon VFD / Inverter Meter

Multi-Range Programmable DC Power Supplies 9115 Series

The full wave rectifier consists of two diodes and a resister as shown in Figure

Modular I/O System Analog and Digital Interface Modules

Dual Display Digital Multimeter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Measuring Electric Phenomena: the Ammeter and Voltmeter

EXPERIMENT 7 OHM S LAW, RESISTORS IN SERIES AND PARALLEL

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

1587/1577. Insulation Multimeters. Users Manual

Ground Resistance Clamp On Tester

Insulation resistance testing. A complete solution for every person.

Objectives: Part 1: Build a simple power supply. CS99S Laboratory 1

Lab 3 Rectifier Circuits

Multi-Range Programmable DC Power Supplies 9115 Series

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Beginners Guide to the TDS 210 and TDS 220 Oscilloscopes

User Guide. 4 wire Earth Resistance Tester Model GRT300

Electronic WorkBench tutorial

= V peak 2 = 0.707V peak

Table of Contents. Title

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

RLC Series Resonance

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Oscilloscope, Function Generator, and Voltage Division

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

The new Velleman Projects catalogue is now available. Download your copy here:

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

TMS TANK MANAGEMENT SYSTEM

Transcription:

Mastech M9803R Version 2008-Jan-1 Dept. of Electrical & Computer Engineering Portland State University Copyright 2008 Portland State University

1 Basic Information This guide provides basic instructions for operating the Mastech M9803R Bench Digital Multimeter. The M9803R provides these features: Multiple measurement functions: DC & AC voltage, DC & AC current, resistance, audible continuity test, capacitance, frequency, diode test True RMS capability 4 ½ digit backlit LCD display with 42 segment bar graph Auto and Manual Range with data hold RS232C computer interface 2 Instrument Front Panel Figure 1: Mastech M9803R front panel Copyright Precision Mastech Enterprises Co. 1

LCD Panel The LCD shows the measured value as numbers in the center of the display. In addition, a multi-segment bar graph gives an analog representation of the value. At the bottom of the panel is a row of annunciators that indicate the range mode, measurement unit (V, A, Ω, F, Hz), and multiplier (n, µ, m, k, M). Power Switch This switch controls the AC line input to the multimeter. It is located at the rear of the multimeter case. Function / Range Selector Rotary Switch The rotary switch selects which measurement function to perform. For DC and AC current measurements, it also sets the range 1. The multimeter is turned off by rotating the switch to the OFF position. When the switch is in any other position, the multimeter is turned on. DC & AC current (up to 10 A) Multimeter OFF AC voltage DC voltage DC & AC current (up to 400 ma) Selection indicator Resistance & Continuity Diode test Frequency Multimeter OFF Capacitance Figure 2: Close-up view of the rotary switch Copyright Precision Mastech Enterprises Co. 1 Use a range that is just large enough to accommodate the maximum DC or AC current to be measured. As an example, if the actual current is 15 ma, then the 40 ma range is optimal. The 4 ma range is too small, while the 400 ma range is too big. Note that 400 ma will work, but the 40 ma range has better resolution. 2

Function Buttons These buttons activate additional multimeter functions. Some often used buttons are: BACKLIGHT illuminates the LCD display. FUNCTION SELECTOR When the rotary switch is set for Resistance & Continuity, pressing this button toggles between Resistance mode and Continuity mode. When the rotary switch is set for DC and AC current (A), pressing this button toggles between DC mode and AC mode. When the rotary switch is set for DC and AC current (ma), pressing this button toggles between DC mode and AC mode. RANGE RANGE allows manual selection of the measurement range Differences among Auto Range, Manual Range, and Fixed Range modes In Auto Range mode, the multimeter automatically chooses the appropriate range for measuring and displaying the data. In Manual Range mode, the user can step through different ranges by pushing the RANGE button. In Fixed Range mode, the range is set by the position of the rotary switch, so the RANGE button has no effect. Function Auto Manual Fixed DC Voltage AC Voltage DC & AC Current (A) DC & AC Current (ma) Resistance Continuity Capacitance Frequency Diode Table 1: Available range modes for each measurement function Pressing the RANGE button selects the Manual Range mode. The AUTO annunciator will turn off, and the MANU annunciator will turn on. Each subsequent press of the RANGE button will change the range and update the display. Pressing the RANGE button for longer than one second will exit the Manual Range mode and revert back to Auto Range mode. The MANU annunciator will turn off, and the AUTO annunciator will turn back on. Warning When measuring current, always start at the highest range first and check the measured value. If more resolution is needed, then gradually step down to lower ranges. Failure to follow this procedure can lead to excessive current at the ma or A input terminals of the multimeter and may blow the internal fuse. 3

Input Terminals External test leads are connected to the input terminals of the multimeter. Figure 3: Close-up view of the input terminals Copyright Precision Mastech Enterprises Co. o o o o VΩ Hz Positive input terminal for all functions except current measurements COM Negative (ground) input terminal for all functions A Positive input terminal for both DC and AC current measurements up to 10 A ma Positive input terminal for both DC and AC current measurements up to 400 ma 3 Test Leads Test leads are insulated wires that connect the circuit or component being tested to the multimeter s input terminals. Two leads are required for all measurements. By convention, one lead is color-coded red (positive input), while the other is color-coded black (negative or ground input). One end of the test lead is plugged into an input terminal on the multimeter. The other end can be one of a variety of test connectors. Popular choices include straight test probes, alligator clips, mini-grabbers, and spade lugs. Measuring DC/AC Current (A) A ma COM VΩ Hz Measuring DC/AC Voltage, Resistance, Continuity, Capacitance, Frequency, Diode Measuring DC/AC Current (ma) A ma COM VΩ Hz A ma COM VΩ Hz Figure 4: Standard test lead connections for various measurements 4

4 Measurement Procedures Measuring DC Voltage (V) COM, VΩ Hz 2. Turn the rotary switch to: V 3. Choose either Auto Range (default) or Manual Range. 4. Connect the test leads in parallel across the test circuit. probe tip positive side of circuit probe tip negative side of circuit 5. Read the measured voltage. Note: If the positions of the probe tips are swapped, the measured value will have a negative sign. DC (V) Circuit + Measuring AC Voltage (V) COM, VΩ Hz 2. Turn the rotary switch to: V 3. Choose either Auto Range (default) or Manual Range. 4. Connect the test leads in parallel across the test circuit. 5. Read the measured voltage. Note: The M9803R displays the RMS (Root Mean Square) magnitude of the AC waveform. AC (V) Circuit Measuring DC & AC Current (up to 10 A) COM, A 2. Turn the rotary switch to: 3. Use the FUNCTION SELECTOR button to set whether DC or AC current will be measured. A 4. Turn off power to the test circuit and then connect the test leads in series with the circuit branch to be measured. 5. Turn on power to the circuit and read the measured current. DC & AC (A) Circuit 5

Measuring DC & AC Current (up to 400 ma) COM, ma 2. Initially, turn the rotary switch to: 400mA 3. Use the FUNCTION SELECTOR button to set whether DC or AC current will be measured. 4. Turn off power to the test circuit and connect the test leads in series with the circuit branch to be measured. 5. Turn on power to the circuit and read the measured current. Note: If the value does not have enough resolution, then use the rotary switch to progressively lower the range setting to either 40mA or 4mA. DC & AC (ma) Circuit Measuring Resistance (Ω) COM, VΩ Hz 2. Turn the rotary switch to: 3. Choose either Auto Range (default) or Manual Range. 4. Turn off any power to the test device. Connect the test leads across the resistor. 5. Read the measured resistance. Note: Measurement accuracy can be improved by using REL mode (Refer to full Users Manual). Measuring Capacitance (F) COM, VΩ Hz 2. Turn the rotary switch to: 3. Choose either Auto Range (default) or Manual Range. 4. Turn off any power to the test device and discharge the capacitor 2. Ω 5. Connect the test leads across the capacitor. If the capacitor is polarized, be sure to follow the polarity markings. 6. Read the measured capacitance. Note: Measurement accuracy can be improved by using REL mode (Refer to full Users Manual). Resistance (Ω) Capacitance (F) 2 The capacitor can be safely discharged by shorting a large resistor (e.g., 100 kω) across the two capacitor leads. 6

Appendix 1 Resolution and Accuracy DC Volts (mv DC) 400 mv 0.1 mv ± (0.3% rdg + 5d) 4 V 1 mv ± (0.3% rdg + 2d) 40 V 10 mv ± (0.3% rdg + 2d) 400 V 100 mv ± (0.3% rdg + 2d) AC Volts (true rms, ac-coupled) 4 V 1 mv 40 V 10 mv 400 V 100 mv ± (0.8% rdg + 5d) 50Hz to 60Hz ± (1.2% rdg + 2d) 45Hz to 1kHz DC Current 4 ma 1 µa ± (0.8% rdg + 5d) 40 ma 10 µa ± (0.8% rdg + 5d) 400 ma 100 µa ± (0.8% rdg + 5d) 10 A 10 ma ± (1.5% rdg + 10d) AC Current 4 ma 1 µa ± (1.5% rdg + 5d) 45Hz to 400Hz 40 ma 10 µa ± (1.5% rdg + 5d) 45Hz to 400Hz 400 ma 100 µa ± (1.5% rdg + 5d) 45Hz to 400Hz 10 A 10 ma ± (2% rdg + 10d) 45Hz to 400Hz Resistance 400 Ω 0.1 Ω ± (0.5% rdg + 5d) 4 kω 1 Ω ± (0.5% rdg + 3d) 40 kω 10 Ω ± (0.5% rdg + 3d) 400 kω 100 Ω ± (0.5% rdg + 3d) 4 MΩ 1 kω ± (1% rdg + 5d) 40 MΩ 10 kω ± (1.5% rdg + 10d) Capacitance 4 nf 1 pf ± (2% rdg + 40d) in relative mode 40 nf 10 pf ± (2% rdg + 5d) in relative mode 400 nf 100 pf ± (2% rdg + 5d) in relative mode 4 µf 1 nf ± (2% rdg + 5d) 40 µf 10 nf ± (2% rdg + 5d) @ 20 µf ± (5% rdg + 5d) @ > 20 µf Appendix 2 References [1] M9803R Bench Multimeter Users Manual, Precision Mastech Enterprises Co. 7