Application of Foundry Sand In Civil Construction

Similar documents
Effect of basalt aggregates and plasticizer on the compressive strength of concrete

Lab 1 Concrete Proportioning, Mixing, and Testing

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

Strength and Workability Characteristics of Concrete by Using Different Super Plasticizers

AGREGADOS RECICLADOS MITOS Y REALIDADES

EXPERIMENT NO.1. : Vicat s apparatus, plunger

CATALOGUE OF PRODUCTS

NOTE: FOR PROJECTS REQUIRING CONTRACTOR MIX DESIGN, THE DESIGN PROCEDURES ARE SPECIFIED IN THE SPECIAL PROVISIONS OF THE CONTRACT.

Chapter Two Types of Cement The properties of cement during hydration vary according to:

To go into depth on fly ash would be beyond the scope of this paper. Nevertheless, believe us ASH IS CASH.

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

Chapter 8 Design of Concrete Mixes

Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

1.5 Concrete (Part I)

"APPLICATION OF COAL COMBUSTION BY-PRODUCTS IN MASONRY PRODUCTION" Tarun R. Naik Director, Center for By-Products Utilization

What is Cement? History Overview of the Cement Manufacturing Process Brief Overview of Kiln Operations Why Burn Wastes?

SIEVE ANALYSIS OF FINE AND COARSE AGGREGATES

:: ARTIFICIAL SAND :: Zone One Sand : Zone Two Sand :

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

Analysis of M35 and M40 grades of concrete by ACI and USBR methods of mix design on replacing fine aggregates with stone dust

STRENGTH OF CONCRETE INCORPORATING AGGREGATES RECYCLED FROM DEMOLITION WASTE

Stabilization of Soil with Self-Cementing Coal Ashes

Construction Materials Testing. Classes of Test

METHOD A7 THE DETERMINATION OF THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF GRAVEL, SOIL AND SAND

FACT SHEET: HYDRATED LIME FOR MASONRY PURPOSES

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

PROPERTIES AND MIX DESIGNATIONS

Residues from aluminium dross recycling in cement

SOIL-LIME TESTING. Test Procedure for. TxDOT Designation: Tex-121-E 1. SCOPE 2. APPARATUS 3. MATERIALS TXDOT DESIGNATION: TEX-121-E

PROPERTIES OF ZINC ALLOY CAST PRODUCT WITH DIFFERENT COMPOSITION OF SILICA SAND AND BENTONITE IN GREEN SAND MOULD

Stone crusher dust as a fine aggregate in Concrete for paving blocks

GROUND GRANULATED BLAST FURNACE SLAG & SLAG CEMENT

Hardened Concrete. Lecture No. 14

EXPERIMENT 10 CONSTANT HEAD METHOD

Properties of Concrete with Blast-Furnace Slag Cement Made from Clinker with Adjusted Mineral Composition

CGA Standard Practices Series. Article 600 Standard for Pozzolan Enhanced Grouts Used in Annular Seals & Well Destruction

Dubai Municipality Standard DMS 1: Part 5: 2004

Evaluation of M35 and M40 grades of concrete by ACI, DOE, USBR and BIS methods of mix design

2. PREPARATION OF TEST SPECIMENS


Properties of Fresh Concrete

DURABILITY OF MORTAR LININGS IN DUCTILE IRON PIPES Durability of mortar linings

Site sampling and testing of concrete

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

Coal Properties, Sampling & Ash Characteristics by Rod Hatt Coal Combustion, Inc. Versailles, KY

Example Specification for Concrete using Current Building Code Requirements

Casting. Training Objective

Pavement Thickness. esign and RCC-Pave Software. Roller-Compacted Concrete Pavement: Design and Construction. October 24, 2006 Atlanta, Georgia

POWDER PROPERTIES LABORATORY

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 888 PORTLAND CEMENT CONCRETE PAVEMENT USING QC/QA.

Evaluation of Initial Setting Time of Fresh Concrete

INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCES Volume 1, No 3,2010. Copyright 2010 All rights reserved Integrated Publishing services

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

Influence of Nano-SiO 2 and Microsilica on Concrete Performance

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Materials for the production of primary aluminium

Quality Assurance Program. June by Texas Department of Transportation (512) all rights reserved

TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. ABSTRACT

Standard Test Procedures Manual

Standard Test Procedures Manual

ISIDAÇ 40. building chemicals. Special cement for your special products!

MASONRY INFORMATION. Selecting and Specifying Mortar and Grout for Unit Masonry. Introduction. Desirable Mortar Properties. Selection of Mortar


EXPERIMENTAL INVESTIGATION ON STRENGTH AND DURABILITY PROPERTIES OF HYBRID FIBER REINFORCED CONCRETE

Manufacturing Quality Concrete Products

PROJECT PROFILE ON CEMENT CONCRETE HOLLOW BLOCKS

A Study on the Flexural and Split Tensile Strengths of Steel Fibre Reinforced Concrete at High Temperatures

Recycling and Utilization of Mine Tailings as Construction Material through Geopolymerization

Lapping and Polishing Basics

STANDARD INSPECTION & TEST PLAN (ITP) FOR CIVIL WORKS :

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

still different technique of assessment.

Modern Sand Reclamation Technologies for Economy, Environment Friendliness and Energy Efficiency

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

It is an important tool to assess factors that affect the bioavailability of a drug from a solid preparartion.

Apr 17, 2000 LAB MANUAL PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)

Objective: Preparation of Materials Lesson Instructions

The Effects of Various Lime Products for Soil Drying

Strength of Concrete

GLOBAL MANUFACTURING. ARAUJO, Anna Carla AUG, 2015 Mechanical Engineering Department POLI/COPPE/UFRJ

Jacket crown. Advantage : Crown and Bridge

Ultra-High Strength Concrete Mixtures Using Local Materials

Guide to Magnetic Materials

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Physical and Chemical Properties of Materials

Mold Preventing I nterior System

FLEXURAL AND TENSILE STRENGTH PROPERTIES OF CONCRETE USING LATERITIC SAND AND QUARRY DUST AS FINE AGGREGATE

Transcription:

IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN: 2278-1684, PP: 38-42 www.iosrjournals.org Application of Foundry Sand In Civil Construction Mr. I.M. Attar 1 Prof. A.K. Gupta 2 (Student M.E. (C&M) Part-I, -416101 (Professor & Vice-Principal, Dr.J.J.Magdum College Of Engineering, Jaysingpur-416101) ABSTRACT: This work continues the research on recycling of waste in the manufacture of brick. Initially, clay with a major content of soil was used. The obtained specimens showed high porosity due to the combustion of the organic matter present. Moreover, this type of raw material has properties that vary greatly according to the extraction sites. In order to improve quality and achieve uniformity in the properties of the obtained products, samples with commercial clay in similar composition are studied in this work. By recycling of waste reduces damping area as well as control the pollution. 1. INTRODUCTION A foundry is a manufacturing facility that produces metal castings by pouring molten metal into a preformed mold to yield the resulting hardened cast. The primary metals cast include iron and steel from the ferrous family and aluminium, copper, brass and bronze from the nonferrous family. Foundry sand is high quality silica sand that is a by-product from the production of both ferrous and nonferrous metal castings. The physical and chemical characteristics of will depend in great part on the type of casting process and the industry sector from which it originates. Metal foundries use large amounts of sand as part of the metal casting process. Foundries successfully recycle and reuse the sand many times in a foundry. When sand can no longer be reused in the foundry, it is removed from the foundry and is termed. Foundry sand production is nearly 6 to 10 million tons annually. Like many waste products, has beneficial applications to other industries. Foundries purchase high quality size-specific silica sands for use in their molding and casting operations. The raw sand is normally of a higher quality than the typical bank run or natural sands used in fill construction sites. The sands form the outer shape of the mold cavity. These sands normally rely upon a small amount of betonies clay to act as the binder material. Chemical binders are also used to create sand cores. There are two basic types of available, green sand (often referred to as molding sand) that uses clay as the binder material, and chemically bonded sand that uses polymers to bind the sand grains together. Green sand consists of 85-95% silica, 0-12% clay, 2-10% carbonaceous additives, such as sea coal, and 2-5% water. Green sand is the most commonly used molding media by foundries. The silica sand is the bulk medium that resists high temperatures while the coating of clay binds the sand together. The water adds plasticity. The carbonaceous additives prevent the burn-on or fusing of sand onto the casting surface. Green sands also contain trace chemicals such as MgO, K2O, and TiO2. Chemically bonded sand consists of 93-99% silica and 1-3% chemical binder. Silica sand is thoroughly mixed with the chemicals; a catalyst initiates the reaction that cures and hardens the mass. There are various chemical binder systems used in the foundry industry. The most common chemical binder systems used are phenol-urethanes, epoxy-resins, fury alcohol, and sodium silicates. 2. PHYSICAL CHARACTERISTICS OF FOUNDRY SAND I. TYPICAL PARTICLE SIZE AND SHAPE Foundry sand is typically sub angular & rounded in shape. After being used in the foundry process, a significant number of sand agglomerations. When these are broken down, the shape of the individual sand grains is apparent. II. GRAIN SIZE ANALYSIS OF FOUNDRY SAND The grain size distribution of spent is very uniform, with approximately 90to 98 percent of the material between 4.75mm and 600micron sieve sizes. Five to 20 percent of can be expected to be smaller than 300 micron sieve size. The particle shape is typically sub angular to round. A Waste gradation has been found to be too fine to satisfy some specification for fine aggregate. III. WHAT COLOR IS FOUNDRY SAND? Green sand is typically black or gray in color. Chemically bonded sand is typically a medium tan or off -white color IV. SLUMP TEST Unsupported concrete when it is fresh will flow to the sides and sinking height will to be placed. This 38 Page

vertical settlement is known as slump. The slump test does not measure the workability of concrete but is very useful in detecting variations in the uniformity of a mix of given nominal proportions. The mould for slump test is frustum of cone placed on a smooth surface with smaller opening at the top and filled with concrete with three layers. Each layer is in tamped 25 times by a slandered 16 mm tamping rod. Immediately after filling the cone it slowly lifted, and the unsupported concrete will now slump hence the name of test is slump test. In order to reduced the influence on slump of the variations in the surfaces frictions the inside of the mold and its bas are moistened at the beginning of every test. 1. For natural sand For w: c ratio of 0.6 to 0.7 shear slump 2. For 10% + 90% sand For w: C ratio of 0.6 to 0.7 shear slump 3. For 30% + 70% sand For w: C ratio of 0.7 shear slump. 4. For 60% + 40% sand No shear slump V. COMPACTION FACTOR TEST There is no generally accepted method of directly measuring in the amount of work necessary to achieve full compaction probably the best test yet available uses the universe approach, the degree of compaction achieved by a standard amount of work is determined. The degree of compaction, called the compacting factor, is measured by the density ratio i.e. ratio of density actually achieved in the test to the density of the same concrete fully compacted. The density of concrete in the cylinder is calculated after passing the concrete through the two hoppers, and the density actually achieved by the fully compacted concrete is defined as the compacting factor. The later density can be obtained by actually filling the cylinder with concrete in three layers, each tamped or alternatively calculated from the absolute volumes of the ingredients. The test is more resistive at the low workability ends of the scale than at high workability. Very dry mixes tend to sticks in one or both hoppers and the material has to be eased gently by polling with still rod. Moreover, it seems that for concrete of very low workability the actual amount of work required for full compaction depends on the weakness of the mix while the compacting factor does not. The compacting factor test provides a good measured of workability. COMPACTION FACTOR OBSERVATION TABLE NATURAL SAND 1 0.5 16.415 16.515 0.993 2 0.6 18.315 18.325 0.999 3 0.7 18.920 19.050 0.993 10%FOUNDRY SAND +90%NATURAL SAND 1 0.5 15.780 15.810 0.998 2 0.6 18.460 18.580 0.993 3 0.7 19.545 19.765 0.988 30%FOUNDRY SAND + 70%NATURAL SAND 1 0.5 15.655 15.720 0.995 2 0.6 16.650 16.700 0.997 3 0.7 19.130 19.200 0.997 60%FOUNDRY SAND + 40%NATURAL SAND 39 Page

1 0.5 15.395 15.655 0.983 2 0.6 15.915 16.930 0.940 3 0.7 16.885 17.015 0.992 SIGNIFICANCE AND LIMITATION: 1. When more size of aggregate is larger as compared with mean particle size the drop into bottom container will produce segregation and give unreliable comparison with other mixes of smaller maximum aggregate size. 2. The method of introducing concrete into mold bars no relationship to any of the more common methods of placing and compacting high quality concrete. 3. Compaction factor test establishes the fact that with increases in the size of coarse aggregate the workability will decreases. 3. CHEMICAL PROPERTIES I. FOUNDRY SAND Spent (chemically bonded sand) consists primarily of silica sand. Following table lists the chemical composition of typical sample of spent. As per our finding the sand has very minute loss on ignition which is around 8.90 %.It indicates that if the is used in the construction it also can be used in the regions where the temperatures are high.acid soluble matter in has no effect on concrete since its presence is in very negligible amount. The other contents of the are the same as found in the natural sand that is used for the construction purpose such as silica, alumina and ferrous oxide. The presence of lime i.e. calcium oxide increases the binding property of the sand to form mixture.thus the overall effect of the chemical contents of on the concrete is no different than sand. Loss on ignition 8.90% Water soluble matter 0.03% Acid soluble matter 8.50% Content of SiO2 0.50% Contents of Al2O3 2.67% Content of Fe2O3 0.59% Contents of Cao 2.65% TABLE NO.1 II. ph value of The ph of was determined in the laboratory and was found to be around 13. This defines that the is very alkaline in nature. But as the replaces the natural sand by means of percentage and not completely hence Ph of when it is replaced with the natural sand was determined. Table shows the ph of solution (25% suspension) of the mixture of by percentage. SAMPLE Ph value 100% 13 40 Page

10 % + 90% natural sand 7.65 30 % + 70%natural sand 7.85 60% + 40% natural sand 8 TABLE NO 2 As the Ph of the solution of and the natural sand lies around the natural sand (with 10, 30, 60% replacement of natural sand by ) Lies around the neutral value. It indicates it s no contribution towards enhancing the corrosion of the steel used in concrete 4. WORK DONE AND SCHEDULE REGARDING CASTING OF CONCRETE A study investigating the beneficial reuse of in cast-iron place concrete and concrete blocks. Several concrete mixes using (chemically bounded sand ) as a partial replacement for fine aggregate we are developed and tested, concrete block from several mixes we are prepared testing of thesplitting tensile strength. The concrete mixes we are designed using weigh analysis replacement of fine aggregates with foundry sand ranged 10%, 30% 60%, all mixed design used a water cement ratio 0.45. Concrete blocks were cast manually in laboratory. Design mixes for blocks were developed based on sieve analysis data. Three mixes were developed using 10%, 30% & 60% replacement of fine aggregates with foundry sand. The 7days & 14 days compressive strength of the blocks were then determined. The compressive strength of the block decreased as the percentage of is increased. However the mixes containing replacement of 10% produced strength higher than the minimum strength of concrete blocks. The average strength of the percentage of 30% and 60% is sufficient to use in practices. Also the concrete cylinder was cast manually in the laboratory with the same procedure as concrete blocks. We are determined the tensile strength after curing 7 days and 14 days. The splitting tensile strength of cylinder decreases with respective increasing percentage of. The table shows the actual work done and schedule regarding the casting of concrete blocks and concrete cylinders. The table shows the strength variations in concrete blocks and concrete cylinder after replacement of natural sand by percentage of. After 7 days After 14 days proportion Compressive Splitting tensile Compressive Splitting tensile Strength strength Strength strength ( N/mm 2 ) (N/ mm 2 ) ( N/ mm 2 ) ( N/ mm 2 ) Blocks with 22.37 10 30.87 12.3 natural sand Blocks with 10% 30.37 14.61 35.33 15.87 Blocks with 30% 25.50 13.33 34.09 14.61 Blocks with 60% 24.70 11.28 33.49 12.35 TABLE NO. 03 5.CONCLUSION The success of using depends upon economics. The bottom line issues are cost. Availability of the and availability of similar natural aggregates in the region. If these issues can be successfully resolved, the competitiveness of using will increase for foundries and for end users of the sand. This is true of any recycled material. From physical analysis the physical properties are somewhat similar to the natural sand & chemical analysis 41 Page

there is no harmful chemical in it which gives no hazardous to use in concrete Initially strength increases as the replaces sand from 8% to 13% and a drop takes place in same after that as we go on replacing by natural sand in more quantity by till 13% to20% and increase takes place as we go from 20% to 40% replacement and slight decreases occurs at 60% replacement. But even than it gives more Splitting tensile strength than the minimum strength of concrete given by natural sand REFERENCES Books 1. Concrete technology by M.S. Shetty 2. Engineering chemistry R. V. Gadag Journals 1. Ambuja cement technical literature series (79); conquering concrete sept.2005 2. National building museum annual report 2004 Websites http://www.foundry recycling.com http://www.cwc.org http://wmr.sagepub.com 42 Page