RAM 4021-DPX Operation Manual

Similar documents
RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Model SRMD Setra Remote Monitoring Display

RGC-IR Remote Gas Calibrator for IR400

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Advantium 2 Plus Alarm

User's Guide. Integrating Sound Level Datalogger. Model Introduction

el-720 Carbon Dioxide Gas Leak Detector User s Guide

INSTALLER S & OWNER S MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

ExStik TM ph Waterproof Meters

Medical Air Systems: Scroll

Wireless Indoor/ Outdoor Thermometer

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

CO-220 Carbon Monoxide Meter

INSTRUCTION MANUAL DTH Fax: (503)

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

EzFlex Combustible Gas Leak Detector Model EZ40

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Installation and Operation Guide for PD4100 Series Power Control Centers

Intelli-Time Alarm Clock model 13027

Installation Operation Maintenance Troubleshooting

ENMET Corporation PO Box 979 Ann Arbor, MI ENG 97D STAND-ALONE MANUAL. Manual Part Number MCN-389, 01/21/08

MTX-D, Oil Temperature/Pressure Gauge

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Mold Alert... Operation Manual P0270

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Installation and Operation Guide for PD4000 Series Power Control Center

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

Temperature, Humidity & Dew Point Chart Recorder

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

User Guide for the Kidde RemoteLync. Remote Notification Device

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation Manual DIAPHRAGM WELL TANK

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

MP-4V Heavy Duty Riveter / 39048

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Microwave Meter. Instruction Manual

Installation Instructions

How To Use A Cdm250 Digital Multimeter

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

12-Volt Negative Ground Installation Instructions

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Conserve Insight Energy Use Monitor. User Guide

Installation Instructions

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Air Conditioning Systems Warranty Manual. Version 1.8

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

OPERATING INSTRUCTIONS FOR LED-4 MULTI-SPORT TABLETOP SCOREBOARD

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

IR Repeater. Operation Manual P8620

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

MODEL G300 BRAKE BLEEDER

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Wireless Home Security System Product Manual (Model #80355)

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Leak Detection System

Weather Radio Alarm Clock

INSTALLATION INSTRUCTIONS PART NUMBER:

Automatic Phone-Out Home Monitoring Systems

We reserve the right to make technical changes.

Model 349KLX Remote Display Digital Scale User Instructions

Model Owner s Manual. Español - P. 19 Français - P. 39

EX-5175-EC Sensor/Transmitter Manual

Alarm Clock USER GUIDE

P. D. Q. Automatic Burnout Furnaces. 115 and 230-volt Models OPERATOR S MANUAL

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Installation and Operation Guide PD4600 Series Converter Replacement

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

Part I - Installation

Water Leak Detection System

Customer Support

Universal Wireless Effects Controller USER S GUIDE SA115

Instruction Manual CPPM-4

PAINT SPRAY GUN WASHER

SR 801. DK... Digitalvægt... 2 GB... Digital Scale... 7 D... Digitalwaage S... Digitalvåg U.S.A. and countries outside the EU...

Transcription:

RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions

ABL 4021-DPX /RAM 4021-DPX TABLE OF CONTENTS DESCRIPTION...1 General 1 SET UP PROCEDURE...2 Set-up modes 2 OPERATION...4 CALIBRATION...5 Calibration carbon monoxide sensor with co test gas 5 Dew point sensor calibration 6 ZERO/CAL adjustment for carbon monoxide 6 MAINTENANCE (qualified technicians only)...7 Dew point sensor replacement 8 Carbon monoxide sensor replacement 8 TROUBLESHOOTING SECTION...9 Zero fail during CO calibration 9 Calibration gas fail during co calibration 9 ACCESSORIES AND FIELD REPLACEMENT PARTS...10 ACCESSORIES 10 REPLACEMENT PARTS 10 EQUIPMENT TECHNICAL DATA...11 4021-DPX DIAGRAM...12 WARRANTY...13 WIRING DIAGRAM...14

ABL-4021-DPX FOR YOUR SAFETY Like any piece of complex equipment, the GfG Instrumentation ABL-4021 series will do the job it was designed to do, only if it is used and serviced in accordance with the manufacturer s instructions. All individuals who have or will have the responsibility of servicing the equipment must carefully read this manual. The warranties made by GfG Instrumentation with regards to this instrument are voided, if the product is not used and serviced in accordance with the instructions in this manual. Please protect yourself and others who depend on this instrument by following these instructions. The above does not alter statements regarding GfG Instrumentation s warranties and conditions of sale and delivery. DESCRIPTION General This unit is designed to provide continuous monitoring of the carbon monoxide and dew point in the levels of breathing air. The instrument s electronics are enclosed in a NEMA-4X polycarbonate case. The case is corrosion resistant, positively pressurized by the compressor supply line, and sealed except for a bleed hole to exhaust the compressor s air. The unit operates on 110 V AC power. It comes equipped with a case mounted horn that may be disconnected if not required. 1

Calibration adjustment controls are not necessary since they are automatically performed by the microprocessor. The carbon monoxide chemical cell has a life expectancy of two to three years with a 30-day calibration check recommended. The dew point sensor has an expected life of two years and requires no calibration due to its auto calibration feature. SET UP PROCEDURE By briefly depressing the top button (see Figure 1) it is possible to cycle through the set up parameters. Each time the top button is depressed the display screen will identify the selected mode and will indicate the current set up. The lower button will change the parameter. Set-up modes The following outlines the set up modes and options available. In each mode it is possible to change the set up using the lower button. DPalm xx.x Dew point high relay setting (dryer failure alarm) DLalm xx.x Dew point low relay setting (dryer control) COalm xx CO XX The alarm point in parts per million is displayed The part per million of carbon monoxide to be used for calibration is displayed (i.e. CO - 20). 2

The carbon monoxide test gas concentration may be set from 5 to 100 PPM and is factory set to 20 PPM. It is important to use the same test gas as the CAL setting, otherwise the calibration will fail because of the error protection feature. NOTE: This set-up must be identical to the PPM concentration of the carbon monoxide calibration gas (5-50 PPM CO). CO rly DP rly DL rly Test Mode The carbon monoxide alarm relay (remote) can be made operational (ON) or disabled (OFF) in this mode. Setting the relay ON or OFF permits any auxiliary device connected to them to be shut off if not needed. During calibration it will be automatically shut off. Setting the relay ON or OFF permits any auxiliary device connected to them to be shut off if not needed. Factory set to 10 degrees F. (Dryer failure relay) Used for controlling a dryer to cycle on/off at the set point determined-factory set to - 4 degrees F. Activates alarms and solid squares on LED readout when lower button is pushed. The alarm horn and light relays may be tested by pressing and holding the bottom button while in alarm test Set-Up mode. When testing an auxiliary horn, be sure the relay is turned ON. 3

OPERATION Plug the unit into 110 V AC and the display will show introductory messages and a warm-up countdown. If the unit does not power up, check the electrical connections and try replugging the unit. If the start up does not occur, call the factory. After the warm-up countdown, the instrument will display CO readings. The air regulator may be adjusted at any time to set the flow level from 0.5 to 0.9 CFH. If the low flow indication shows on the display, increase the flow to 1 CFH; and then drop the flow to operational range of.5 to.8 CFH. CAUTION: If the unit is reading a carbon monoxide gas level, do not make any adjustment for a few hours until the unit has settled in. If calibration is attempted within the first fifteen minutes, a TOO SOON message will occur on the display. If the carbon monoxide gas readings remain high or below zero (-0), recalibration may be needed. We also recommend checking the compressor s air intake, which may be the cause for high readings. Outside air intake is recommended - but can easily be contaminated by furnace exhaust, building vents, parking lots, etc. Intakes within the building are to be avoided because they often contain low PPM level carbon monoxide. 4

CALIBRATION Calibration carbon monoxide sensor with co test gas (recommended every 30 days) Although the unit was calibrated at the factory, it may require carbon monoxide recalibration due to handling. The only way to assure the sensor is operating properly is to place gas on it. To calibrate the unit with carbon monoxide test gas, shut off the air from the compressor supply line with the regulator, and after a few moments, a LOW FLOW message will appear. Assemble the calibration kit and connect the tank of test gas to the cal port connector on the instrument. Open the gas valve (use only the fixed flow regulator provided with the calibration kit). The display will read CAL GAS DETECTED then WAIT and a 60 second count down will begin. If the compressor air supply line was not shut off, a message will appear SUPPLY OFF. If such a message occurs, shut off the supply air; and then begin the cal process again to activate the cal port switch. After 60 seconds a gas reading will appear. With 20 PPM test gas applied the gas reading should be 20. The number will move around as it s self adjusting, then will automatically set. After the unit auto calibrates, a message will appear CAL PASSED, then REMOVE CAL GAS, indicating that the CO gain adjustment has been set for 20 PPM. This prompts the calibrator to remove test gas. Then the message LOW FLOW appears, prompting the calibrator to turn the supply on at the regulator. 5

If an incorrect gas concentration is used or the sensor and/or instrument is not properly functioning, the auto calibration process will not finish. If the instrument fails to complete the auto calibration process within 5-6 minutes, remove the calibration gas, and the message will appear CAL FAILED. This affords improper calibration protection and an effort should be made to understand why it did not calibrate (see troubleshooting section for assistance). Dew point sensor calibration The dew point sensor does not require external calibration, and will self calibrate periodically, or after a severe humidity change. During the dew point sensor auto-calibration, the dew point reading will remain constant on the display until auto calibration is complete. The auto calibration process will take 2-3 minutes. ZERO/CAL adjustment for carbon monoxide The carbon monoxide read-out (PPM) will be 0 in the absence of carbon monoxide. This 0 can be calibrated by flowing clean air over the sensor and activating the zero/cal set switch. The ZERO/CAL set switch is activated through a small hole in the face of the unit using a wire activator (bent paper clip). Two methods are available to check or set the carbon monoxide ZERO/CAL. With normal flow through the unit from a clean air supply, depress the ZERO/CAL switch and the message ZEROING will appear. Hold closed until the ZEROING message disappears, immediately release the switch, and the instrument will self zero. 6

If the supply air is clean the display will show a 0 reading for CO which indicates that a zero setting has been accepted and is now in use. If the supply line has more than a trace of carbon monoxide the following message will appear ZERO CO, alternating with a flashing CO alarm light. The instrument is informing the user that it will not zero calibrate because of bad Zero air, and it will use its previously zeroed cal setting. CAUTION: Be sure that the cylinder in use is zero gas impurity free air (standard air) when zero initializing. A second method for zeroing is to place zero test gas (Impurity Free Air) in the cal port in the same manner described previously with calibration gas, and the unit will initiate its calibration gas routine. However, the unit expects that 20 PPM CO is being applied in the cal port unless the zero set switch is pushed. Check to see that the message now says ZEROING instead of WAIT with the 60 second countdown. At any time during the countdown the zero may be pushed to program the unit for zero gas. If the set switch is not pushed, the instrument will fail to calibrate. This is the error protection. After the zero button is depressed, a ZEROING message appears. Then release the zero set switch, and the instrument will self zero. MAINTENANCE (qualified technicians only) NOTE: Except for the sensors, all internal parts are to be serviced only by the factory or its authorized agents. 7

Dew point sensor replacement The dew point sensor is shipped to you pre-calibrated, no user calibration is required. The dew point sensor will auto calibrate periodically during use. To replace, disconnect the power to the instrument, unplug and remove the sensor from the dew point sensor chamber, replace sensor and reassemble. Carbon monoxide sensor replacement When CO test gas fails to show a gas response during calibration, or the instrument will not complete calibration, a new sensor is required. Most CO sensors will last from one and one-half years to three years. To replace the sensor, disconnect the power to the unit; remove the four corner screws, and the electronics front cover. Next remove the three screws that hold the grey sensor block and unplug the CO sensor from its socket. Replace with a new sensor after being sure that the shorting wire is removed from the new sensor. Reassemble the unit and reconnect to power. Let the new sensor settle in for at least an hour prior to calibrating. A NEW CO SENSOR MUST BE ZEROED When calibrating a new CO sensor, perform a zero operation prior to a gas calibration procedure. Caution needs to be taken that the air is free of carbon monoxide. If the supply line is not CO free, then obtain a tank of Impurity Free Air test gas from GfG (stock number 7802-006). After a successful zero operation is completed, supply 20 PPM cal gas (or another value selected in the Set Up mode) and perform a gas calibration on the instrument (see calibration section). 8

TROUBLESHOOTING SECTION The CO zero cal will not set if the there is CO gas present, or if the sensor or electronics are bad. Also, the instrument will not calibrate if the incorrect concentration of CO gas is used, or the sensor is bad or beyond its useable life. With 20 PPM CO cal gas the instrument will read close to 20 during calibration. If the computer cannot auto adjust the readout to 0 (zero) or 20 (cal), the zero or calibration will fail. Zero fail during CO calibration If a failure occurs during CO zero cal, the zero air should be questioned for CO content. Another zero operation with known good zero air should be performed. If the instrument still fails to zero, the unit is malfunctioning, call the factory for further instructions. Calibration gas fail during co calibration With 20 CO PPM gas on the unit the reading should reach 20. If the reading does not reach 20, use the appropriate following procedure. 1. If the gas reading does not show any increase when the gas is applied, probably the sensor is expired or the test gas is zero concentration. Check hose connections to assure gas is flowing into the sensor chamber. 2. If the reading is close to 20, a zero calibration procedure with known zero gas will probably correct the problem. If the unit was zeroed with more than a couple PPM of CO, the cal will fail when 20 PPM test gas is applied. 9

ACCESSORIES AND FIELD REPLACEMENT PARTS ACCESSORIES 7750-001 Calibration kit (includes calibration connector and 20 ppm test gas 34 L) 2605-002 High pressure regulator (5,000 PSI) 1301-002 Remote horn 110 V AC REPLACEMENT PARTS 5503-020 Sensor chemical cell 1702-DPX Dew point sensor 7750-004 Calibration regulator 7802-001 Test gas - 20 ppm carbon monoxide 34 L 7802-006 Test gas - impurity free Air 34 L (zero gas) 10

EQUIPMENT TECHNICAL DATA Gases detected Carbon monoxide Dew point Sensor Electro chemical Solid state cell Thin film type Meter scale 0 to 100 ppm CO -80 F to +40 F Response 90% max. in 20 sec N/A Accuracy +/- 1ppm +/- 3 F Expected sensor life 3 years 2 years CO sensor warranty 1 year Operating temperature range (sample +32 F to 105 F air) Factory set adjustable alarm points 10ppm CO (H) +10 F(L) -4 F Standard inlet pressure ½ feed - 80 to 120 psig Sample flow rate 0.5 cubic feet of air per hour (scfh) Relays 1 CO alarm 250 V AC/30 V DC @7A 2 dew point Power source 110 V AC @ 1A Dimensions 7.3 x 5.9 x 4 inches (L x W x H) (185 x 150 x 101 mm) 11

FIGURE 1 4021-DPX DIAGRAM set up buttons 12

WARRANTY GFG INSTRUMENTATION, INC., warrants each new electrical product manufactured by it to be free from defective material and workmanship for the purpose intended, for a period of one (1) year from the date of sale to the original purchaser, and agrees to remedy any such defect or to furnish a new part (at the company s option) in exchange for any part of any product of its manufacture which under normal use, and service disclosed such defect; provided the product is delivered by the purchaser to GFG S factory, intact, for our examination, with all transportation prepaid to our factory, provided that such examination discloses, in our judgment, that it is thus defective. This warranty does not extend to any products that have been subjected to misuse, neglect, accident, unauthorized modifications, or to use in violation of instructions furnished by us, nor does it extend to products that have been repaired or altered outside of our factory. This warranty is in lieu of all warranties express or implied and no representative or person is authorized to assume for us any other liability in connection with the sale of our products. All implied warranties are limited to the duration of this written warranty. In no event is GfG INSTRUMENTATION, INC., liable for special, incidental, or consequential damages arising from any breach of warranty of product. 13

WIRING DIAGRAM 14