GAS DISTRIBUTION PRODUCTS METER RISERS

Similar documents
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

Gas Risers and Transition Fittings


8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P B E B B B-24267

WATER SERVICE 2

Engineering Specifications

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Hose Clamps & Fittings

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

Section 2100-Trenching and Tunneling

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

INDEX. Sec. No. Items Page Nos.

SECTION POLYVINYL CHLORIDE (PVC) PIPE

ANTENNA PARTS CATALOG

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH BLACK & GALVANIZED STEEL PIPE

Copper Meter Resetters

SECTION STORM DRAINAGE SYSTEM

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

Dock Hardware & Accessory Products Catalog

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

COATING & WRAPPING OF UNDERGROUND PIPING

Copper and Copper Alloy Tube, Pipe and Fittings

Tubing and Accessories

SECTION PIPE HANGERS AND SUPPORTS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Saves time. Saves money. Up to 2 size for commercial gas piping.

NITROUS TRANSFER PUMP INSTRUCTIONS

Installation Instructions S

AMF112 Instruction Manual

City of San Diego, CWP Guidelines

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Installation Instructions

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

SOLDERING PROCEDURE SPECIFICATIONS PROCEDURE QUALIFICATION RECORDS. and SOLDERER PERFORMANCE QUALIFICATION RECORDS

Many Products...One Source

SECTION DUCTILE IRON PIPE AND FITTINGS

Specification for Rotary Drill Stem Elements

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Cables. Accessories. For Force, Torque and Strain Sensors

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Scepter PVC Molded Junction Boxes

SECTION 1 GENERAL REQUIREMENTS

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

DRESSER TM PIPELINE SOLUTIONS

James M. Pleasants Company

Pipe Cutting and Beveling Clamshells

Nordson Automatic Spray Gun Support Kits

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

Mechanical Installation

Sewer Line Rehabilitation

Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)

INSTALLATION INSTRUCTIONS. SharkBite. Connection System. The SharkBite System

SECTION 807 PUMP STATION REHABILITATION

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

Trouble shooting guide

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

Pipe Repair Products A complete selection for all types of pipe

Mueller B-101 and A-3 Drilling and Tapping Machines

AZEK Rail Install Guide

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Residential Plumbing

AMF112 ( <00>) 13mm (1/2 in.)

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Chapter 7 Plumbing Connections

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Mini USB and USB 2.0-IP67 Connector System

Shingle Installation Guide

SECTION 1 COMPANY OVERVIEW

Scraper Passage Indicator. Electrical Indicator. Features

Guidelines for Earthquake Bracing Residential Water Heaters

ASX7-4-IOM-7 J

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Ford Pipe Repair Products The Ford Meter Box Company, Inc.

81000 Series Aluminum Gate Valve Installation and Repair Manual

ROUGHNECK II Pumpless Drain

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

NFPA31FuelOilPiping 1 Revised

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Watts Pure Water Systems

Cable Runways & Accessories

INSTALLATION INSTRUCTIONS P-TRAP SUPPLY KIT Model: RH-3016 These instructions are a guideline for a basic installation

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

DC Series Digital Conversion Alarm Operator s Manual

Transcription:

METER RISERS

INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today a leading manufacturer of connectors for the Gas Utility, Gas & Water Distribution, Propane, Plumbing and Cathodic Protection markets. An ISO 9001 certified company, Continental Industries has manufacturing locations in Tulsa and Broken Arrow, Oklahoma. Our employees are committed to providing the best value to our customers. Our full line of plastic and steel connector products are produced utilizing state-of-the-art injection molding machines, automatic screw machines, and CNC machining equipment. Our commitment to quality is evident in every step of our business processes. Renowned for our design and development of technologically advanced products, we provide our customers with reliable, cost-effective solutions to their main to meter service line installation, repair, or renewal problems. thermoweld, our exothermic welding materials and accessories products, provide a simple, efficient, cost effective method of permanently connecting two or more conductors utilizing a high temperature exothermic reaction between Aluminum and Copper Oxide to produce an almost pure copper weld. We manufacture all of our weld metal and molds in Oklahoma so you are certain of getting consistent, high quality products to satisfy your exothermic welding needs. Our Vision Simply stated, our vision is To be a Sales and Customer Driven Company. Our commitment to providing the best value to our customers is shared by the entire organization and is evidenced by both the number of long standing relationships we have gratefully developed over the years and the new relationships we are developing every day. Why Use Continental Industries is the industry leader in the manufacturing of plastic and steel mechanical fittings for the Gas & Water industry. From the Con-Stab ID Seal to Scope, steel saddles to HVT, quality and service is what drives us at Continental Industries. Manufacturing fittings since 1958, Continental has the experience and confidence necessary to provide the best quality products on the market today. Continental Industries mechanical fittings will save you both time and money and give you the peace of mind that comes with using a quality product. Continental Industries uses only the highest quality raw materials, engineered designs and manufacturing processes to ensure the consistent quality that makes Continental Industries products second to none. With regional sales offices located throughout the United States, a Continental Industries representative is only a phone call away to help with any questions you may have. Come experience what so many other satisfied customers have experienced, the excitement and family atmosphere that is Continental Industries! TABLE OF CONTENTS Anodeless Meter Risers... 3-6 Chamfer Tools... 7 Flex Risers...8-10 Riser Brackets...11 2 For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit

THE ULTIMATE CONNECTION INDUSTRIES ADVANTAGES Adapter machined from solid bar stock; not welded. Casing is TIG welded to adapter which provides a stronger and higher quality weld joint. Casing wall thickness exceeds ASTM requirements. Every part is leak tested. Bending performed through roll bending as opposed to rotary bending. Listed with IAPMO/UPC and CSA. For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit 3

INDUSTRIES THE ULTIMATE CONNECTION Specifications: Meets or exceeds all requirements for the Categorization of Mechanical Fittings within ASTM D2513 Category 1, and requirements from the Code of Federal Regulations, Title 49 part 192.281, 192.283 and 192.375. Meets or exceeds NFPA-58. Listed with IAPMO/UPC and CSA. Pipe Threads conform to ANSI B1.20.1. All Gas Carrying Steel parts meet or exceed ASTM A53. Casing Materials meet or exceed ASTM A 513. All polyethylene pipe and tubing components conform to ASTM D 2513. 4 For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit

THE ULTIMATE CONNECTION INDUSTRIES SIZE VERTICAL HORIZONTAL PART NUMBER WALL PART NUMBER (MPT X PE) LENGTH LENGTH with Con-Stab 1/2 MPT X 1/2 CTS (5/8 OD) PE.090 30 15 1253-91-4604-00 1253-91-4604-25 3/4 MPT X 1/2 CTS (5/8 OD) PE.090 18 19 9953-99-0520-00 9953-99-0521-00 3/4 MPT X 1/2 CTS (5/8 OD) PE.090 30 17 1353-91-4604-00 1353-91-4604-25 3/4 MPT X 1/2 IPS PE SDR-9.3 (.090) 30 17 1353-91-4612-00 1353-91-4612-25 3/4 MPT X 3/4 IPS PE SDR-11 (.095) 30 16 1353-91-4613-00 1353-91-4613-25 3/4 MPT X 1 CTS (1 1/8 OD) PE.099/.101 30 16 1353-91-4608-00 1353-91-4608-25 1 MPT X 1 CTS (1 1/8 OD) PE.099/.101 30 16 1453-91-4608-00 1453-91-4608-25 1 MPT X 1 IPS PE SDR-11 (.119) 30 16 1453-91-4614-00 1453-91-4614-25 1 1/4 MPT X 1 1/4 IPS PE SDR-10 (.166) 30 22 1553-91-4615-00 1553-91-4615-25 1 1/4 MPT X 1 1/4 IPS PE SDR-11 (.151) 30 22 1553-91-4615-0A 9953-99-0503-25 1 1/2 MPT X 1 1/2 IPS PE SDR-11 (.173) 36 26 1652-91-4616-00 1652-91-4616-25 2 MPT X 2 IPS PE SDR-11 (.216) 36 30 1752-91-4617-00 1752-91-4617-25 For sizes not listed, contact Continental Industries. Pressure rating Designed to meet or exceed pressure rating of PE pipe per 49 CFR Part 192 and ASTM D2513. Recommended accessories for Anodeless Meter Risers with Con-Stab ID Seal Couplings; Continental s Bladed Chamfering Tool. See below. Part numbers listed are for 2406 medium density polyethylene pipe. For part numbers with 3408 high density pipe, contact Continental Industries. = CSA Approved / = IAPMO/UPC Listed For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit 5

INDUSTRIES 1 Verify the stab fitting is the correct size for the polyethylene (P.E.) pipe. Verify the SDR (or wall thickness) of the pipe matches the SDR (or wall thickness) printed on the fitting label. 2 ASSEMBLY INSTRUCTIONS : ID SEAL CON-STAB IMPORTANT For use on: Polyethylene gas pipe meeting the requirements of ASTM D 2513 Pressure Rating: Designed to meet or exceed pressure rating of PE pipe per 49 CFR Part 192 and ASTM D 2513 Operating Temperature: -20 to 140 F Cut pipe ends square. 5 Mark the stab depth by inserting pipe into ID chamfer tool and marking the pipe at the entrance as shown. 6 If using ID chamfer tool with gauge, check for proper chamfer by inserting pipe on gauge up to the o ring. With proper chamfer, o ring will begin to enter pipe. THE ULTIMATE CONNECTION Proper Chamfer Improper Chamfer 3 Clean piping thoroughly to assure there is no dirt, grease or oil in assembly area. 4a Chamfer end of pipe using Continental's ID chamfering tool with ID gauge. or 4b Chamfer end of pipe using Continental's double ended ID chamfering tool. Stab pipe completely 7 into fitting entrance. 8 Stab pipe completely into fitting so that the mark on the pipe is within 1/8" from the fitting entrance. 9 10 Repeat steps 1 thru 8 for all Con-Stab joints. To assure proper assembly and to comply with 49 CFR 192 Subpart J Test Requirements, the joint shall be leak tested. 6 PATENT #'S 5,366,260, 5,692,785 & 5,853,272 For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit

THE ULTIMATE CONNECTION INDUSTRIES CHAMFER TOOLS ID CHAMFERING TOOLS To Be Used With Con-Stab ID Seal Fittings CATALOG NO. DESCRIPTION DOUBLE ENDED ID CHAMFER TOOLS 0000-33-5647-00 1/2 IPS X 1/2 CTS (5/8 OD) 0000-33-5481-00 3/4 IPS X 1/2 CTS (5/8 OD) 0000-33-5652-00 3/4 IPS X 1/2 IPS 0000-33-5480-00 1 CTS (1 1/8 OD) X 1/2 CTS (5/8 OD) 0000-33-5963-00 1 CTS (1 1/8 OD) X 1/2 IPS 0000-33-5763-00 1 CTS (1 1/8 OD) X 3/4 CTS (7/8 OD) 0000-33-5589-00 1 CTS (1 1/8 OD) X 3/4 IPS 0000-33-5514-00 1 IPS X 1/2 CTS (5/8 OD) 0000-33-5516-00 1 IPS X 3/4 IPS 0000-33-5606-00 1 IPS X 1 CTS (1 1/8 OD) ID CHAMFER TOOL SWITH GAUGE 0000-33-6580-04 1/2 CTS (5/8 OD).090 WALL 0000-33-6580-08 1 CTS (1 1/8 OD).099/.101 WALL 0000-33-6580-12 1/2 IPS SDR-9.3 0000-33-6580-13 3/4 IPS SDR-11 0000-33-6580-14 1 IPS SDR-11 0000-33-6580-15 1 1/4 IPS SDR-10 (.166 WALL) 0000-33-6580-10 1 1/4 IPS SDR-11 (.151 WALL) 0000-33-6580-16 1 1/2 IPS SDR-11 0000-33-6580-17 2 IPS SDR-11 DOUBLE ENDED ID CHAMFER TOOL ID CHAMFER TOOL W/ GAUGE Continental Can Provide For All Of Your Main To Meter Connection Needs For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit 7

INDUSTRIES ConFlex Risers are designed to meet or exceed pressure rating of PE pipe per 49 CFR Part 192 and ASTM D2513.. THE ULTIMATE CONNECTION ConFlex Risers conform to trench depth and flex with ground movement. ConFlex Risers may be installed with or without meter set present. ConFlex Risers have a swivel feature to allow tightening the Service Head Adapter without turning the flex hose. Service Head Adapter design has been used in the natural gas industry since 1967. The Service Head Adapter offers a simple and dependable installation method. The stiffener is integral to the adapter coupling. It does not fall out. No loose components. The Service Head Adapter design is listed by IAPMO and CSA. Service Head Adapter meets the requirements of ASTM F 1948 and ASTM D 2513. ConFlex Risers meet the requirements of; ASTM D 2513 D.O.T. Title 49 of the Code of Federal Regulations, Part 192.283 (b) and 192.375. NFPA 54 & NFPA 58 ConFlex Risers have a moisture seal as required in NFPA 54 & NFPA 58. The Flex Hose meets 300 lb tensile requirement and 1000 lb crush requirement stated in NFPA 58. The Flex Hose to Service Head Adapter joint meets 300 lb tensile requirement stated in NFPA 58. Liner Sleeve provided to meet requirements of NFPA 58. IAPMO and CSA Listed. 8 For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit

THE ULTIMATE CONNECTION INDUSTRIES SIZE (MPT X PE) WALL 1/2 MPT X 1/2 CTS (5/8 OD) PE.090 3/4 MPT X 1/2 CTS (5/8 OD) PE.090 1 MPT X 1/2 CTS (5/8 OD) PE.090 3/4 MPT X 3/4 CTS (7/8 OD) PE.090 1 MPT X 3/4 CTS (7/8 OD) PE.090 3/4 MPT X 1 CTS (1 1/8 OD) PE.099/.101 1 MPT X 1 CTS (1 1/8 OD) PE.099/.101 1 1/4 MPT X 1 CTS (1 1/8 OD) PE.099/.101 LENGTH PART NUMBER PART NUMBER w/ Liner Sleeve w/o Liner Sleeve 36 1253-92-1004-36 1253-96-1004-36 60 1253-92-1004-60 1253-96-1004-60 72 1253-92-1004-72 1253-96-1004-72 84 1253-92-1004-84 1253-96-1004-84 96 1253-92-1004-96 1253-96-1004-96 36 1353-92-1004-36 1353-96-1004-36 60 1353-92-1004-60 1353-96-1004-60 72 1353-92-1004-72 1353-96-1004-72 84 1353-92-1004-84 1353-96-1004-84 96 1353-92-1004-96 1353-96-1004-96 36 1453-92-1004-36 1453-96-1004-36 60 1453-92-1004-60 1453-96-1004-60 72 1453-92-1004-72 1453-96-1004-72 84 1453-92-1004-84 1453-96-1004-84 96 1453-92-1004-96 1453-96-1004-96 36 1353-92-1006-36 1353-96-1006-36 60 1353-92-1006-60 1353-96-1006-60 72 1353-92-1006-72 1353-96-1006-72 84 1353-92-1006-84 1353-96-1006-84 96 1353-92-1006-96 1353-96-1006-96 36 1453-92-1006-36 1453-96-1006-36 60 1453-92-1006-60 1453-96-1006-60 72 1453-92-1006-72 1453-96-1006-72 84 1453-92-1006-84 1453-96-1006-84 96 1453-92-1006-96 1453-96-1006-96 36 1353-92-1008-36 1353-96-1008-36 60 1353-92-1008-60 1353-96-1008-60 72 1353-92-1008-72 1353-96-1008-72 84 1353-92-1008-84 1353-96-1008-84 96 1353-92-1008-96 1353-96-1008-96 36 1453-92-1008-36 1453-96-1008-36 60 1453-92-1008-60 1453-96-1008-60 72 1453-92-1008-72 1453-96-1008-72 84 1453-92-1008-84 1453-96-1008-84 96 1453-92-1008-96 1453-96-1008-96 36 1553-92-1008-36 1553-96-1008-36 60 1553-92-1008-60 1553-96-1008-60 72 1553-92-1008-72 1553-96-1008-72 84 1553-92-1008-84 1553-96-1008-84 96 1553-92-1008-96 1553-96-1008-96 For sizes not listed, contact Continental Industries. Pressure rating Designed to meet or exceed pressure rating of PE pipe per 49 CFR Part 192 and ASTM D2513. = CSA Approved / = IAPMO/UPC Listed Installation Instructions provided with each riser or visit for installation instructions. For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit 9

INDUSTRIES THE ULTIMATE CONNECTION SIZE (MPT X PE) 1/2 MPT X 1/2 IPS PE 3/4 MPT X 1/2 IPS PE 1 MPT X 1/2 IPS PE 3/4 MPT X 3/4 IPS PE SDR-11 (.095) 1 MPT X 3/4 IPS PE SDR-11 (.095) 1 MPT X 1 IPS PE SDR-11 (.119) 1 1/4 MPT X 1 1/4 IPS PE WALL LENGTH PART NUMBER PART NUMBER w/ Liner Sleeve w/o Liner Sleeve 36 1253-92-1012-36 1253-96-1012-36 60 1253-92-1012-60 1253-96-1012-60 SDR-9.3 72 1253-92-1012-72 1253-96-1012-72 (.090) 84 1253-92-1012-84 1253-96-1012-84 96 1253-92-1012-96 1253-96-1012-96 36 1353-92-1012-36 1353-96-1012-36 60 1353-92-1012-60 1353-96-1012-60 SDR-9.3 72 1353-92-1012-72 1353-96-1012-72 (.090) 84 1353-92-1012-84 1353-96-1012-84 96 1353-92-1012-96 1353-96-1012-96 36 1453-92-1012-36 1453-96-1012-36 60 1453-92-1012-60 1453-96-1012-60 SDR-9.3 72 1453-92-1012-72 1453-96-1012-72 (.090) 84 1453-92-1012-84 1453-96-1012-84 96 1453-92-1012-96 1453-96-1012-96 36 1353-92-1013-36 1353-96-1013-36 60 1353-92-1013-60 1353-96-1013-60 72 1353-92-1013-72 1353-96-1013-72 84 1353-92-1013-84 1353-96-1013-84 96 1353-92-1013-96 1353-96-1013-96 36 1453-92-1013-36 1453-96-1013-36 60 1453-92-1013-60 1453-96-1013-60 72 1453-92-1013-72 1453-96-1013-72 84 1453-92-1013-84 1453-96-1013-84 96 1453-92-1013-96 1453-96-1013-96 36 1453-92-1014-36 1453-96-1014-36 60 1453-92-1014-60 1453-96-1014-60 72 1453-92-1014-72 1453-96-1014-72 84 1453-92-1014-84 1453-96-1014-84 96 1453-92-1014-96 1453-96-1014-96 SDR-10 (.116) 36 N/A 1553-96-1015-36 SDR-11 (.151) 36 N/A 9953-99-0445-00 1 1/2 MPT X 1 1/2 IPS PE SDR-11 (.173) 36 N/A 1653-96-1016-36 2 MPT X 2 IPS PE SDR-11 (.216) 36 N/A 1753-96-1017-36 For sizes not listed, contact Continental Industries. Pressure rating Designed to meet or exceed pressure rating of PE pipe per 49 CFR Part 192 and ASTM D2513. = CSA Approved / = IAPMO/UPC Listed Installation Instructions provided with each riser or visit for installation instructions. 10 For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit

THE ULTIMATE CONNECTION RISER BRACKETS INDUSTRIES 17-6133-00 6 Stand-Off 17-6134-00 9 Stand-Off 17-6134-01 9 Stand-Off (2) 3/8 wide x 2 long angular mounting slots Accommodates 1/2 thru 1 1/4 flex risers Powder coated finish Mounting hardware included (2) 3/8 wide x 2 long angular mounting slots Accommodates 1/2 thru 1 1/4 flex risers Powder coated finish Mounting hardware included Accommodates 1/2 thru 1 1/4 flex risers Powder coated finish Mounting hardware included 17-6135-00 Universal Riser Bracket Can be used for virtually any mounting situation Foundation, single or double remote installations Accommodates 1/2" thru 2" risers Carriage bolts supplied for ease of assembly Powder coated finish Foundation mounting hardware included (2) 3/8 wide x 1-5/8 straight mounting slots (Drivepost shown sold separately) For Assistance Call 1-800-558-1373 or FAX 1-800-788-1668 Visit 11

OTHER QUALITY PRODUCTS FROM INDUSTRIES CON-STAB ID SEAL FITTINGS MECHANICAL SADDLES & FITTINGS STEEL SERVICE TEES Con-Stab ID Seal Fittings STEEL COUPLINGS Mechanical Saddles & Fittings TRANSITION FITTINGS Steel Service Tees EFV FITTING CATALOG Steel Couplings IN-LINE REPAIR FITTINGS Transition Fittings WATER DISTRIBUTION PRODUCTS PVC WATER FITTINGS EFV Catalog The Contractors Choice From standard to special s, continental industries has your in-line repair Fitting. no other single manufacturer can offer the variety of repair Fittings that continental industries provides. the ultimate connection In-Line Repair Fittings PVC Water Fittings ID SEAL and thermoweld are registered trademarks of Continental Industries thermoweld for Cathodic Protection INDUSTRIES 1140 North 129th East Ave. Tulsa, Oklahoma 74116 (Phone) 800-558-1373 or 918-627-5210 (Fax) 800-788-1668 or 918-622-1275 0000-99-1046-00 ECN 2653 REV K 05/15