STC 2P Series Solenoid Valves

Similar documents
STC 3S A Series Solenoid Valves

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

Advantium 2 Plus Alarm

Assisted lift operated 2/2-way solenoid valves Type EV250B

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Solenoid valves 2/2-way direct-operated Type EV210A

Load Cell Amplifier Module. Instruction Manual LCA

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

3/2-way Solenoid Valve, direct-acting, NC or NO

Leak Detection System

Terms and Conditions v

BroadBand PowerShield. User Manual

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

PROTECTO 401 Price List

4 Posiflow Proportional Solenoid Valves

Price List January 1, 2015

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

AIRCRAFT FUEL PUMP & PARTS PRICE LIST

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

TERMS AND CONDITIONS

System 8. ü ( System 8

Mini-led spotlight with magnetic base

Warranties All Products. Revised: 8/1/15 7 Pages

Ceiling Mount Air Handler Manual

Single Station Remote Alarm

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

SELLING TERMS AND CONDITIONS

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

GM DURAMAX LMM Fuel Pickup Kit Installation Guide

In-Tank Fuel Pump Installation Instructions (Read Carefully Before Starting Project)

Park 250 Brushless Outrunner Instructions

Installation Instructions

Air vacuum pump with r134a & r12/22

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Part I - Installation

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

Mini Power Bank and Charger

3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

RT-200 HI-TEST ROPE TESTER

PRECISION MICRODYNAMICS QUOTE / CONTRACT TERMS & CONDITIONS

INSTANT HOT WATER RECIRCULATING SYSTEM

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Triton Systems of Delaware, LLC Warranty Statement / Return Policy

SAVARD PLUMBING COMPANY

Installation Instructions

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

SolarEdge Technologies Ltd.

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

This AGREEMENT is made as of the day of in the year of, by and between the following parties, for the sale of materials.

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

RGC-IR Remote Gas Calibrator for IR400

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Ozone Generator Manual

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

el-720 Carbon Dioxide Gas Leak Detector User s Guide

VW TDI (Golf, Jetta, New Beetle) Upgrade Turbocharger

IR Repeater. Operation Manual P8620

VPCCCare. Virtual PC Center Service Warranty Program

Infineon Technologies North America Corp. Terms and Conditions of Sale

COMPLIANCE WITH LAWS, CODES, AND STANDARDS

CABLE MODEM QUICK START

TERMS AND CONDITIONS OF SALE. Quotations, Purchase Orders, Acknowledgements, Packing Lists/Slips, Invoices & Credits

Web Site Hosting Service Agreement

INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

MODEL G300 BRAKE BLEEDER

PALLET JACK TON

Installation and Operation Guide PD4600 Series Converter Replacement

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Installation, Operation, Repair and Parts Manual

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

GRIPS. into a brilliant universe of chrome

PURCHASE ORDER ACKNOWLEGMENT AND TERMS AND CONDITIONS

VK-250 WARRANTY REGISTRATION FORM

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

LCD5500Z / PKP-LCD v3.x Installation Instructions

MOTOROLA MOBILITY INC. LIMITED GLOBAL WARRANTY MOTOROLA TABLET COMPUTER

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

24.2L M.A.N. V12 Engine Module

Installation Instructions

, User s Manual

MP-4V Heavy Duty Riveter / 39048

Owner s Manual. Pelican Custom Premium WHWF 1865/2162

User and Installation Guide

Transcription:

STC 2P160-250 Series Solenoid Valves 2P160-250 Series Solenoid Valve Specifications Valve Model 2P160-1/2 2P200-3/4 2P250-1 Valve Type Action 2 Way, Normally Closed (NC) Direct Lift Diaphragm, Uni-Directional Cv (Orifice, mm) 4.8 (16) 7.6 (20) 12 (25) Operating Pressure Proof Pressure 0 to 90 PSI 200 PSI Operating Temperature Media: -5 to 50 C; Ambient: -5 to 35 C Port Size (NPT) 1/2 3/4 1 Body Materials Seal Materials Coil Duty Voltage Voltage Tolerance Coil Power Electrical Connections Service ENGINEERED NYLON NBR (Buna N), Options: VITON, EPDM Class H, IP65, 100% ED Voltage Options: 12, 24VDC; 24, 110/120, 220/240 VAC, 50/60Hz 10% of Specified Voltage 14 to 30W DIN 43650, Form A Air, Inert Gas, Liquid, Vacuum S T C TM 1

2P160-250 SERIES SOLENOID VALVE COMPONENTS 2

Installation and Operation: To connect the valve Inlet and Outlet: Connect the inlet and outlet in the direction of the arrow marked on the valve. To install coil: Put the coil onto the armature tube of the valve. Put the lock-washer and nut onto the armature tube. Hand tighten the nut, then use a wrench to tighten the nut to a quarter turn; do not over-tighten the nut, it may cause the armature tube to fail pre-maturely. To connect DIN coil: 1. Remove the Philip screw from the plastic housing and unplug it from the DIN coil. 2. From the screw opening, push the terminal block out from the plastic housing. 3. Note the 1, 2 and ground markings on underside of DIN enclosure. 4. For DC DIN Coil, Connect 1 to Positive, 2 to Negative. 5. For AC DIN Coil, connect 1 to HOT wire, 2 to Neutral wire, and if required connect 6. Do not energize the coil without installing it onto the valve, it will burn the coil and create fire hazards. Safety Note: Standard valves are supplied with continuous duty coils. The proper class of insulation for the service is indicated on the coil. The coil temperature may become hot after being energized for extended periods, but it is normal. Do not energize the coil without installing it onto the valve or connect the coil to a wrong voltage, as it may overheat and damage the coil; although the coil is made of flame retarded material, misuse of the coil in this manner could create fire hazards and generate smoke or burning odor which indicates excessive coil temperature and should disconnect the power to the coil immediately. Operation: 2P160-250 series valve is a 2/2 Direct Lift Diaphragm Normally Closed, zero differential, solenoid valve. When the valve receives an electrical signal, a magnetic field is formed which attracts the plunger covering the main orifice to lift off, causing system pressure to drop. As system pressure on the top of the diaphragm is reduced, full system pressure on the other side of the diaphragm acts to lift the diaphragm away from the main orifice, which allows media to flow through the valve. Since the bleed orifice is dimensionally smaller than the pilot orifice, the system pressure cannot rebuild on the top of the diaphragm as long as the pilot orifice remains open. When the valve is de-energized, it releases its hold on the plunger. Then the plunger forced by the spring drops and covers the main orifice. The system pressure builds up on the top of the diaphragm through the bleed orifice, forcing the diaphragm down until it covers the main orifice and stops media flow through the valve. 3

2P160-250 Series Solenoid Valve Installation Dimensions L (MM) H (MM) 2P160 74 115 2P200 70 115 2P250 87 125 4

Catalog No.: PUB 2012 2P160-250 Terms and Conditions By purchasing from SIZTO TECH CORPORATION (STC), you agree to these TERMS AND CONDITIONS. No other terms shall apply except as agreed in writing signed by us. We reserve the right to correct typographic errors and reject orders. SHIPMENTS: All shipments are F.O.B. 892 Commercial Street, Palo Alto, CA 94303, USA. Most orders are shipped via UPS Standard Ground unless instructions accompany order. Outside the UPS zones, shipment will be made Best Way. The responsibility for goods delay, lost or damaged in transit rests with the carrier and purchaser. Purchaser may purchase shipping insurance to cover lost or damaged products caused by shipping. RETURN OF MERCHANDISE: No merchandise is accepted for return 30 days after delivery date. No credit allowed on merchandise shipped as ordered and returned without obtaining an authorization number IN ADVANCE. A 20% restocking charge applies to all returns, and transportation charges must be fully prepaid. We will pay ground transportation charges on re-sent or returned merchandise due to STC's error. Shortages & Mis-Shipments: Any shortages or mis-shipment must be reported within 15 days. CANCELLATION POLICY: Blanket order can be canceled 90 days before scheduled ship date. There will be a 10% charge if a blanket order is cancel within 90 days of scheduled ship date, and a 20% charge if cancel within 60 days. Regular order for non-custom parts can be canceled any time before the order is shipped. For custom parts, a 30% down payment is required either at the time of order or 90 days prior to scheduled ship date, whichever comes later.. Remittances should be sent to: Sizto Tech Corporation, 892 Commercial Street, Palo Alto, CA 94303, USA Credit Card Payments: Visa, MasterCard, Discover, or American Express Accepted International Customers: Advance Payment Required via Bank Wire, Cashier's Check or Approved Credit Card. Credit Application: To establish a net 30 day account, please mail or fax three trade references with complete mailing addresses and account numbers. LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER: Sizto Tech Corporation (STC) only warrants this product to be free from defects in materials and workmanship at the time of shipment. This limited warranty expires one year after delivery to the end-user. STC s entire obligation to the Purchaser for breach of this limited warranty shall be limited to replacement of the defective product or refund of the original purchase price of this product, at STC s option. Purchaser has thirty (30) days to return the goods after STC has agreed to accept the return. All freight charges on returned material shall be paid by the Purchaser. STC s limited warranty shall not apply, however, to the product that have been subjected to misuse, alteration, accident or negligence during handling or storage.. DISCLAIMER OF IMPLIED WARRANTIES: All implied warranties, which may arise by implication of law or application of course of dealing or usage of trade, including, but not limited to, implied warranties of merchantability or fitness for a particular purpose are expressly excluded. There are no warranties, which extend beyond the description of the faced hereof. The end user is solely responsible for the suitability and fitness of this product selected for a particular application. OBLIGATIONS You warrant, represent and agree: (1) to comply with all laws; (2) that our sale and shipment of the product will not, by export thereof, your legal status or otherwise, cause us to violate any law; and (3) to indemnify us against any losses from a failure by you or a third party to comply with law or these terms and conditions, or from use of the product. SAFETY WARNING Failure or improper selection or improper use of the components and products described herein or related items can cause death, personal injury and/or property damage. This document and other related information from STC provide products options for further investigation by users having the technical expertise. It is important that you analyze all aspects of your application and review the information concerning the component or product in the current catalog. Due to the variety of operation conditions and applications for these components or products, the user, through his own analysis and testing, is solely responsible for making the final selection, installation and maintenance of the products and assuring that all performance, safety and warning requirements of the application are met. All products set-ups and maintenance require the supervision of a qualified individual who is familiar with installation, inspection and testing through training or experience. IMPORTANT NOTICE: The products described herein, including without limitation, product features, specifications, design, availability and pricing, are subject to change without notice. We continuously improve the products, and we reserve the right to change specifications without incurring any obligation to incorporate new factors in equipment previously sold. Information contained herein may be changed without prior notification. S T C Sizto Tech Corporation 892 Commercial Street Palo Alto, CA 94303 USA Tel: 650-856 8833 Fax: 650-856 8811 Email: Sales@StcValve.com; www.stcvalve.com 5