A Technical Publication from the Co-ordination and Information Centre. Dangerous Goods Transport Tanks

Similar documents
Intermodal Containers Presented by Bill Hand Training Coordinator Hazardous Materials Response Team Harris County, Texas

Transportation of Soils Contaminated with Flammable Liquids

Transportation of Radioactive Materials

Reference in RID/ADR (restructured) to published standards and standards in preparation at CEN TC 23/256/261/268/286/296

A Guide to the Transportation of Dangerous Goods Regulations

External Visual Inspection Form

Hydrostatic Testing of Aviation Components

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Portable Pipelines for First Responders

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Western Plant Health Association DOT MC 330 & 331 NH3 Cargo Tank Inspection Checklist Form

University of Tennessee Safety Guidelines

Pressure Vessels (Air Compressors) and LPG Tanks

This will also provide you with the knowledge to insure long life for your Investment

A placard provides the viewer with a variety of information through several different methods. First is the color of the placard.

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

NFPA31FuelOilPiping 1 Revised

Dangerous Goods Safety Guidance Note. Road transport of dangerous goods in receptacles of more than 500 L or kg

List of Frequently Utilized Storage Tank Standards and Practices

The Engineering Science of Oil Pipelines

Queen's University Environmental Health and Safety

How To Stop A Gas Leak

Welding Codes and How They're Used (DOD) (ANSI). (AWS), (ASME) (API). not American Welding Society AWS D1.1 AWS D1.2 AWS D1.3 AWS D1.4 AWS D1.

D.O.T. REQUIREMENTS FOR TRANSPORTATION OF SAMPLE CONTAINERS. Thomas F. Welker Welker Engineering Company

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

EXPIRATION DATE: March 31, GRANTEE: Structural Composites Industries (SCI) Pomona, CA

Compressed Gas Cylinder Safety

UCLA - Compressed Gas Cylinder Storage and Handling

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

Portable Pipelines for First Responders. Chris Christopoulos, Jr.

BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013)

Notes. Material 1. Appropriate Flammable Liquids

EXTENSION OF PERIODIC INSPECTION INTERVAL FOR LPG CYLINDERS

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

SCBA Frequently Asked Questions

Guidance for Those Who Use and Store Gas Cylinders

Introduction- Joe Conner, Founder/ President

BRAZED PLATE INSTALLATION MANUAL

Compressed Gas Cylinder Program

S6.3 Administration. c) Rules for repairs and modifications of transport tanks are provided in NBIC Part 3, Repairs and Alterations, Supplement 6.

GAS CYLINDER SAFETY. 2. GRADES OF GASES BOC have divided the gases that they supply into 3 grades.

Spill Prevention, Control and Countermeasure Plan (SPCC) Program

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Procedures for Inspection Bodies Testing and Inspection of UK Tanks

ENGINE COOLING SYSTEM

Section VIII, Div. 1 (Rules for Construction of Pressure Vessels).

STORAGE TANK SELECTION AND SIZING (ENGINEERING DESIGN GUIDELINE)

Revised April (May) 2015

Hazardous Materials Packagings

Advantages and Disadvantages of the Preferred Alternative Fuels

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Oil and Gas Pipeline Design, Maintenance and Repair

Design of a Fuel Oil Storage Facility

PRESSURE EQUIPMENT SAFETY REGULATION

Mechanical Systems Competency 1.20

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

2002 E D I T I O N INSTRUCTOR

Natural Gas Emergencies

PLBG/GAS SAFETY Information Bulletin

A Job Safety Execution Plan is required. mixtures of the above called, natural gas liquids (NGL's) refined products and their components

APPLICATION FOR ADR ROAD VEHICLE APPROVAL CERTIFICATE

ASME B31.3 Process Piping. Scope of B31.3 Course

Safe Reliable Professional

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Installation of Underground LP-Gas Systems

Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

Signature and ISX CM870 Fuel System

Gas Detection for Refining. HA University

TABLE OF CONTENT

UltraTech International, Inc. Canadian Secondary Containment Requirements

Compressed Gas Cylinder Storage and Handling Guide

Emergency Response Guide

GUIDELINES FOR THE LOCATION OF STATIONARY BULK AMMONIA STORAGE FACILITIES

=.03% CO2 10/4/2012. Carbon Dioxide (CO2) Safety. Carbon Dioxide (CO2) Safety. Carbon Dioxide (CO2) Safety. Carbon Dioxide (CO2) Safety

mobile pipeline Bulk transportation and storage of energy gases

BP WIND ENERGY POLICIES AND PROCEDURES

CHAPTER 4.2. USE OF PORTABLE TANKS AND UN CERTIFIED MULTIPLE-ELEMENT GAS CONTAINERS (MEGCs)

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

CSA Group Safety Standards for Oil and Gas Pipeline Systems: A Life-Cycle Approach

Waste Oil Collection / Storage

Chapter 7 Plumbing Connections

Tentative Interim Amendment NFPA 59A. Standard for the Production, Storage, and Handling of Liquefied Natural Gas (LNG) 2016 Edition

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES

MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

Example Confined Space Entry Programs

20 TANK CONTAINER STANDARD SPECIFICATION MODEL NUMBER: 24 FSTD 2 QUOTATION NUMBER

Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems. 20.A General B Compressed Air and Gas Systems

CHAPTER 5 WATER HEATERS

Air Eliminators and Combination Air Eliminators Strainers

Civil Engineering Sector Labour-Management Health and Safety Committee

REQUIREMENTS FOR SEPTIC TANK PUMPERS AND CHEMICAL TOILET OPERATORS

LIQUEFIED PETROLEUM GASES

Vehicle Maintenance Facilities Requirements for CNG and LNG Vehicles

Manual piston sampler...m 11

A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

COMPRESSED GAS SAFETY

LNG Storage and Fuel Gas Systems. LNG: Fuel for Shipping, London 15-Feb Carriers & Offshore Units. Jürgen Harperscheidt Sales Manager

Transcription:

Dangerous Dangerous Goods, Goods, Rail Safety Rail & Safety 511 Alberta & 511 A Technical Publication from the Co-ordination and Information Centre Dangerous Goods Transport Tanks March 2016

- 1 - This material is meant as a guide to certain parts of the Transportation of Dangerous Goods Regulations and is not meant to be a substitute for them. It is the responsibility of handlers, offerers and transporters of dangerous goods to consult the Regulations for the exact requirements. The Coordination and Information Centre of can provide accurate information regarding the Regulations 24 hours a day. Co-ordination and Information Centre Dangerous Goods, Rail Safety Branch and 511 Alberta Main Floor, Twin Atria Building 4999 98 Avenue Edmonton, Alberta, T6B 2X3 Tel. Edmonton: (780) 422 9600 Tel. Province-wide: 1 (800) 272 9600 Fax: (780) 427 1044 These telephone lines are recorded to assist in responding to the emergency (natural/manmade) and/or inquiry regarding dangerous goods and to ensure that the information is accurate. Direct any questions regarding the recording to the Compliance Officer responding to your call or contact the Manager of the CIC at 780-427-8660. Legal Authority: Dangerous Goods Transportation and Handling Act, Section 13(1).

- 2 - Bulk Transport Tanks There are two pieces of legislation which cover the use of bulk tanks for transporting dangerous goods: the federal Transportation of Dangerous Goods Regulations; and the Dangerous Goods Transportation and Handling Regulation. The provincial regulations adopt the federal regulations to maintain consistency of the rules within all of Canada for moving dangerous goods. Federal Legislation Part 5.10 requires that anyone offering for transport or transporting Class 2 gases in large tanks comply with the selection and use criteria set out in CSA Standard B622. Part 5.14 requires that anyone offering for transport or transporting Class 3, 4, 5, 6.1, 8 and 9 dangerous goods in large tanks comply with the selection and use criteria set out in CSA Standard B621. These two standards allow the shipper and the carrier of dangerous goods to select the correct type of tank to use for each dangerous good. Both standards refer to the manufacturing standard CSA B620, which outlines how a tank must be constructed and maintained for continued dangerous goods service. All tanks constructed after July 1, 1995 must be built to standard. Only facilities that are registered with Transport Canada can manufacture, assemble, modify, repair or test tanks that are used to transport dangerous goods. A list of registered facilities is available on the Transport Canada website. http://wwwapps.tc.gc.ca/saf-sec-sur/3/fdr-rici/highway/tanks.aspx US Tanks Tanks built in the US to the US Department of Transport standard set out in the Code of Federal Regulations (CFR) Title 49 will have information on identification plates that is similar to their Canadian equivalent tanks. They will be marked MC or DOT instead of the TC mark used in Canada. These tanks are considered equivalent to a tank designed to the Canadian standard and, providing they are built in the US or built before August 31, 2008 in Canada, they can be used in Canada. After August 31, 2008 tanks manufactured in Canada, for use in Canada, must be constructed and maintained according to CSA B620.

- 3 - Tank Types TC 406/306 low pressure, oval shaped, highway tank for general flammable liquids including gasoline, crude oil and diesel. They operate at about atmospheric pressure or 21 kpa (3 psi). It should be noted that TC 406 and TC 306 used in petroleum crude oil service may differ from units used for gasoline and other flammable liquids. There may be design changes such as no internal automatic safety shut off valves. These units are marked TC 306 Crude or TC 406 Crude and are to be used solely for the purposes of transporting crude oil, tars, asphalts, oils, bitumen and cutbacks. Safety features on these tanks include rollover protection by means of a trough at the top of the tank to prevent damage to manholes and vents. Other features include high strength bumpers, safety relief vents and internal baffles to minimize liquid surge and provide added strength to the barrel of the tank. Some tanks have more than one compartment. A void section often separates these compartments to prevent contamination between compartments. These voids must be open to atmosphere. There is a hole at the top and bottom of the void, which must not be plugged. Sometimes the presence of a plug indicates damage to the internal integrity of the tank. A tank found by enforcement staff with a plug will be placed out of service until the unit is repaired at a registered facility.

- 4 - TC 407/307 circular tank. These tanks are capable of operating at pressures higher than those set down for TC 406/306 tanks at 138 kpa (20 psi). They can be constructed to take all flammable liquids including the more volatile Packing Group I liquids, sour crude oil and some corrosives such as CORROSIVE LIQUIDS N.O.S (HYDROCHLORIC ACID). TC 412/312 circular tank. These tanks are capable of operating at pressures higher than those set down for TC 406/306 tanks. Some are steel with large outer stiffening rings and are often lined. The type of lining may prevent the construction of internal baffles in these units and hence they are usually long and narrow to minimize surging. Some tanks constructed to this standard are manufactured from fibreglass reinforced plastic. This type of tank is often used in dual service because it can handle both corrosive liquids and, with suitable grounding capabilities, flammable liquids such as crude oil.

- 5 - TC 331 is a high pressure tank designed for liquefied gases such as propane and anhydrous ammonia. They are designed for high pressures around 1723 kpa (250 psi) depending upon the liquefied gas. Additional features on these tanks may include off tank shutdown systems in the event of a failure during loading or offloading. TC 338 cryogenic gas insulated highway tanks. These are used for cold liquefied gases such as Nitrogen. A variation on this design is the TC 341, another cryogenic unit generally used for Oxygen. Both these types of tanks are designed in a similar manner to a Thermos bottle. They are engineered to keep the cold in and the heat out of the product by having a tank within a tank with a vacuum in-between to lessen heat transfer. They are not designed for high pressure service and operate at pressures of about 345 kpa (50psi) and above depending upon the product. These units often periodically vent gases to maintain the pressure in the tank, especially on hot days.

- 6 - TC 407/412/350 vacuum truck. These tanks are commonly designed with a characteristic large rear door, which opens for dumping. They are generally used for cleanup of chemical spills, oil spills and cleanout of storage tanks. They are also haul crude oil and water from the oil separation process at well heads. A unit dedicated to hauling crude oil may be designated as a TC 350 Crude and the certification plate on the tank would be marked accordingly. A full specification TC 350 tank must have a thermal and remote shutoff installed on all product outlet points, including mud gates, unless it is marked as a TC 350 Crude. As with TC 406/306 Crude tanks, only crude oil or water/oil mixtures from an oil well would be allowed in one of these units. TC 3AXM/3AAXM/3T tube trailers are specialized units that are designed to the CSA B340 Standard used for cylinders. They hold gases, which cannot be easily liquefied, such as natural gas, at very high pressure. These units are usually re-tested using acoustic methods under permits issued by Transport Canada. U.S. DOT units are allowed if they were constructed and in service in Canada prior to January 1, 1993.

- 7 - Identification Plates All tanks used in the service of transporting dangerous goods must have a plate attached to the shell or an integral part of the structure of the tank. The plate must be constructed of a metal that is not subject to corrosion and it must be located on the left side of the tank near the front or, prior to 1 July 1985, on the right side near the front. The plate must be legible. A tank built after 1 July 1995 must be built to the CSA B620 standard and must have a plate attached to it with at least the following information (5.1.6.1.6 in CSA B620): TC Specification e.g. TC 406 or TC 406 Crude; tank vehicle assembler (Tank veh. assembler); tank vehicle serial number; tank vehicle completion and certification date month and year (cert. date); tank manufacturer (Tank mfr.); tank maximum allowable pressure in kpa (MAWP); tank test pressure in kpa (Test P); vessel material specification number; weld material (Weld Matl.); minimum allowable thickness of shell in millimeters (Min. shell thick); minimum allowable thickness of heads in millimeters (Min. head thick); volumetric capacity in litres (Vol. Cap. Litres); date of tank manufacture month and year (Date of mfr.). Manufacturer *Note: Additional information may be required depending on the type of tank and when the tank was constructed. Please refer to the version of the CSA B620 Standard at the time of construction of the tank when determining what information is needed on the tank plate.

- 8 - Tank Testing and Marking All tanks must be tested on a periodic basis as shown in the following table (Table 7.1 in CSA B620): Type External Inspection Internal Inspection Lining Inspection Leakage Test Pressure, Hydro or Pneumatic 406/306 1 year 5 years 1 year 5 years 406/306 Crude 2.5 years 5 years 2.5 years 5 years 407/307 1 year 5 years 1 year 5 years 407 Vacuum with full 6 months 5 years 1 year 2 years opening heads 412/312 1 year 5 years 1 year 5 years 412 Vacuum with full 6 months 5 years 1 year 2 years opening heads 423 1 year 1 year 1 year 5 years 350 6 months 1 year 1 year 2 years 350 Crude 1 year 1 year 1 year 2 years 331 1 year 5 years 1 year (2 years for Chlorine) 5 years (2 years for Chlorine) 338 1 year 5 years 341 1 year 10 years (unless alternative testing 10 years is used) 11 1 year 10 years if it has a manhole 1 year 5 years 51 Portable 2.5 years 5 years 5 years 5 years 56/57 Portable 2.5 years 2.5 years 60 Portable 2 years 4-8-10-12 years 4-8-10-12 years 4-8-10-12 years then every year then every year then every year Types 1,2 and 3 Intermodal 2.5 years 2.5 years 5 years 5 years UN 31 Intermediate Bulk Container (Slip Tanks) 5 years 5 years Lined and unlined tanks in corrosive service must have an annual internal inspection. The lined tanks must also have the lining checked at the same time interval. Unlined tanks in corrosive service must have an annual internal inspection and a thickness test done every 2 years. All tanks with an upper coupler must have the tank checked for corrosion under the upper coupler every 5 years. For additional requirements, refer to Table 7.1, Table 7.2, Table 7.3 and related legend from CSA B620.

- 9 - Each tank must be marked on the side near the metal identification plate or head end with the following letters, as applicable, to show that the periodic tests have been carried out. A new tank requires the initial test information on the manufacturer s plate only: Letter V I P T L K UC WF C Visual (External) Inspection Internal Inspection Pressure Test Thickness Test Lining Inspection Leak Test Upper Coupler Area Inspection Test or Inspection Wet Fluorescent Magnetic Particle Inspection For TC 341 tanks only if a Cold Vacuum Retention test has been carried out instead of an internal (alternative testing). The date the tests were carried out must also appear on the tank, for example (one possible format): 02/09 V I K P 123 shows that visual, internal, leak and pressure tests were carried out in February 2009. The digits 123 represent the last three digits in the Transport Canada registration number of the test facility.