CLFE(X)UTP INSTALLATION AND OPERATION MANUAL

Similar documents
Ethernet over Copper Transmission Extenders. Ethernet Transmission over Coaxial or UTP Cable. Fiber Optic and Ethernet Network Solutions

Ethernet over Copper Transmission Extenders

Model PS-4001 Power Supply User Instructions

IFS SP-PoE Splitter User Manual

8-Port PoE Network Switch

2-Port Gigabit Ethernet Switch Operations Guide

XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design

Provides one channel for Ethernet over existing

Power over Ethernet (PoE)

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Important Safety Instructions

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

User Guide. MT-91 / MT-90 / MT-92 Interlinking Transmitter Module MT-90/MT-92 MT-91

Provides one channel for Ethernet over existing

Digital Satellite Receiver

IMPORTANT SAFETY INSTRUCTIONS

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Power Supply Guide Version 1.0 for D-Show

The Bouncer Bluetooth Stereo Speaker

Rock-Ola Music Center Set-Up and Installation Guide For all Q-Series models 230V, Export

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

HD udta Quick-Start Guide

BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK

AXIS T81B22 DC 30W Midspan

ANI Instruction Manual DIGITAL INDOOR/OUTDOOR TV ANTENNA OMNI-DIRECTIONAL WITH AMPLIFIER INTRODUCTION:

SUB 10 ACTIVE STUDIO SUBWOOFER

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS

Albrecht DR314. DAB/DAB+/FM Radio 1.) User Manual

VG4 Fiber Optic Media Converter

ECM-30 30A AC Power Module Spike Suppressor

24 Wide Screen LED Monitor with HDMI

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

igroove SXT Owner's Manual

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Megapixall Security Tools & Accessories

esata External Storage

PoE+ Extender Switch User's Manual. Rev W

ZaapTV HD509N. User s Guide. How to use the HD509N set-top box

Tone Hammer 500. Owners Manual. Manual Version 1.0

8-Port PoE Network Switch

Antenna Splitter ASA 1. Instruction manual

Power over Ethernet (PoE) Explained

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

User Guide ACT-32T Bodypack Transmitters

Register your product and get support at. AS111. User manual

EAGLE Power over Ethernet Products for IP Powering Applications. Flexibility, Simplicity and Value LAN POWER SYSTEMS. Trend Datacom USA, Inc.

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

ANTENNA DISTRIBUTION SYSTEM USER'S GUIDE

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Spider IV 15. Pilot s Handbook Manuel de pilotage Pilotenhandbuch Pilotenhandboek Manual del Piloto 取 扱 説 明 書

Model 70A00-1. GSM Cellular Communications Center

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

MCA Series Multi-Channel Amplifiers. Operation Manual

AXT620 Ethernet Switch

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Product Scope. Hardened Ethernet. Commercial Ethernet. Extended Ethernet. Wireless Ethernet. Fibre Optic Twisted Pair Coaxial Telephone Wireless

16/32 Channel 1U Rack Mount CCTV Power Supply

User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch

Operation Manual. Multi Channel Power Amplifier DPA-430L

10/100/1000 Base-T to Gigabit Fiber Media Converter

HOME THEATER SYSTEM. Instruction Manual. Model ASR150. Please read the instruction manual carefully before using your unit.

To Purchase This Item, Visit BMI Gaming (800) Owner s Manual

12-Volt 10-Amp Regulated Power Supply

DIGITAL CABLE TV RECEIVER OPERATION MANUAL DVB-C8080AL DIGITAL CABLE RECEIVER DEAR CONSUMER

May by Sonos, Inc. All rights reserved.

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

USER GUIDE LOUDBOX MINI

COBRA Power over Ethernet Products for IP Surveillance Applications LAN POWER SYSTEMS. Trend Datacom USA, Inc.

VAC 50/60Hz Power Adapter

=============================== WARNING

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

Prisma Optical Media Converters Industrial Ethernet 10/100 Switching Mini Media Converters

Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

undx2io 2-in/2-out Dante Wallplate

IP Box Camera ACM Ver Hardware User s Manual

TABLETOP CONTROLLER USER'S MANUAL

User Guide TL-POE150S PoE Injector

Kinivo 301BN HDMI Switch

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

PEDAL POWER ISO-5 User s Manual Version 1.2

EOSP-500 Dual Zone Streaming Music Player User Manual

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Terminal and Dimension

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Comfort Contego User Manual

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Quick Installation Guide 8-Port 10/100/1000Mbps Green Switch

Quick Installation Guide. 16-Port 10/100Mbps Fast Ethernet Switch

2 series II COMPANION MULTIMEDIA SPEAKERS

User's Manual. 8-Port 10/100Mbps with 4-Port PoE Fast Ethernet Switch FSD-804P - 1 -

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

HP UPS R1500 Generation 3

HWg-STE HWg-STE PoE MANUAL

8-Port 10/100Mbps 802.3af / 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch. FGSD-910P / FGSD-910HP User s Manual

Long Reach PoE over Coaxial Extender Kit

INSTALLATION GUIDE. AXIS T8133 Midspan 30W

Transcription:

Ethernet-over-UTP/Twisted Pair Extender with Pass-Through PoE Important Safety Warning: Read and keep these directions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with a dry cloth Install in accordance with the manufacturer s instructions This installation should be made by a qualified service person and should conform to all local codes See further safety instructions on Page 8 The ComNet CopperLine Ethernet over UTP line consists of four models that support 100Mbps Ethernet as well as Pass-through Power over Ethernet (PoE) over twisted pair cable (CAT5, UTP). These models support transmission distances of up to 3,000 feet (914m) at 10 Mbps, or 2,100 feet (640m) at 100 Mbps. The CLFE1UTP, the CLFE4UTP, CLFE8UTP and the CLFE16UTP transport, one, four, eight or sixteen channels respectively. The IEEE 802.3-compliant Ethernet electrical interface of these Ethernet extenders also meets the requirements for IEEE 802.3af PoE power, passing-through up to 30 watts of power per port to the powered device (PD). The series may also be used interchangeably with other CopperLine Ethernet-over-UTP extenders. Environmentally hardened to the requirements of NEMA TS-1/ TS-2 for most out-ofplant applications, and true plug-and-play design ensures ease of installation and operation. LED indicators are provided for rapidly ascertaining the operating status of the device. See Figures 6 8 on Page 7 for LED explanations. Packaged in a rugged aluminum housing, these units are designed for desktop or standalone mounting. The CLFE8UTP and CLFE16UTP are offered in EIA 19 1U high rack for easy installation. See Figures A through C on Page 8 for mounting instructions. See Figures 1 8 for complete installation details. PAGE 1

FIGURE 1 CLFE1UTP UTP FIGURE 2 CLFE1UTP LEFT PANEL + RIGHT PANEL Power Supply Connection via external power adaptor Optional, if there is no power supply connected to the unit it will try to detect PoE. 2 1 Ground Screw* Note: Center pin on power connector is positive (+). For 1-pair mode, use the first pair of pins (pins 1 & 2) of the Extended Ethernet RJ-45 port on the left panel. Note: 4-pair mode is required for PoE. * Warning: A ground connection is required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage. FIGURE 3 CLFE4UTP LEFT PANEL or UTP RIGHT PANEL Ground Screw* * Warning: A ground connection is required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage. PAGE 2

Pass-Through PoE Operations for the CLFE1UTP ComNet s CopperLine CLFE1UTP extended distance IP data and PoE maintains the safety standards for communications found within the 802.3af PoE standards. This is for the protection of products operating in the extended distance transmission chain. In the event of malfunctions the communication system is designed to shut down power transmission to avoid device damage. The CLFE1UTP can be powered by a local power source (12 Volts D.C. or 24 Volts A.C.) or from a single PSE source, such as a network switch s PoE port using its unique Pass-through PoE feature (4-pair mode only). This latter feature eliminates the need for CLFE1UTP local power while also providing power for the camera (See full installation instructions, Page 6). Powering The CLFE1UTP Transceivers Input with external power plug installed. External power adapter (included) Under normal operating conditions CLFE1UTP transceivers should be powered using the PoE source. External power to the CLFE1UTP should be restricted to installations where a camera requires local power. When installing the CLFE1UTP, the following conditions apply which will affect its operations. The CLFE1UTP is provided with the ability to operate using a local external power supply. The standard accessory local power adaptor plug can be used for power supplies that do not have the CLFE1UTP s standard power input connector. When inserting the adaptor into the power input, the CLFE1UTP is only powered from a local power source and not from a PSE source. The camera will continue receiving power from the PSE source and operations will be normal. However, if the external plug adaptor is inserted in the CLFE1UTP and no power is applied, the CLFE1UTP will not power up even if a PoE source is present, the camera will continue to receive power. In this case the CLFE1UTP is not operational and no data will flow. If the CLFE1UTP is externally powered and PSE power is lost, power to the CLFE1UTP must be recycled in order for the PSE to recognize the PD (Camera). PAGE 3

FIGURE 4 CLFE8UTP or UTP or UTP 12V Power Supply Ground Screw* * Warning: A ground connection is required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage. FIGURE 5 CLFE16UTP or UTP or UTP or UTP 12V Power Supply or UTP Ground Screw* * Warning: A ground connection is required for the surge protection to work. Failure to ground properly voids the warranty and may cause damage. PAGE 4

FIGURE 6 POSSIBLE ETHERNET CONFIGURATIONS Multiple Configurations are possible. Consult ComNet Design Center. Single Port CopperLine over UTP NVR PoE Switch CNGE2FE24MSPOE 3,000ft 328ft CLFE1UTP (914m) Cat-5 CLFE1UTP (100m) Cat-5 PoE Camera Multi Port CopperLine over UTP CLFE16UTP 3,000ft (914m) Cat-5 CLFE1UTP 328ft (100m) Cat-5 PoE Camera NVR PoE Switch CNGE2FE24MSPOE CopperLine 4-Port Switch Extended over UTP or Coax CLFE16UTP CLFE16UTP 3,000ft (914m) Cat-5 OR 5,000ft (1524m) Coax CLFE4US1TPC 328ft (100m) Cat-5 IP Cameras IP Cameras NVR PoE Switch CNGE2FE24MSPOE CopperLine Managed High Power Midspan NVR 3,000ft (914m) Cat-5 Data + Power CLFE1UTP CLFE1UTP PoE Camera 5,000ft (1524m) Coax Data +Power Switch CNGE2FE24MS CLFE16IPS CLFE1UTP CLFE1UTP PoE Camera PAGE 5

IP Camera-END InstaLLation (CLFE1UTP) S1 S2 S3 Off On Set the S1 10/100BaseT dip switch to the appropriate rate based on the required maximum data rate and maximum distance. OFF = 10BaseT; ON = 100BaseT Set the S2 Master/Slave dip switch to ON for Master mode Set the S3 1- or 4-pair dip switch ON for 1-pair or OFF for 4-pair operation. For systems not utilizing PoE, connect the 12V Power Supply to the power connector of the CLFE1UTP. A power adapter connector is provided to simplify connection. CAUTION: If the external power adaptor is connected with no power applied, the CLFE1UTP will not recognize the PoE source and the system will be inoperative. Connect the IP camera RJ-45 connector to the 10/100BaseT Ethernet port of the CLFE1UTP using a standard Cat5/6 cable, 100m length (max). Connect one end of the long UTP cable to the RJ-45 connector of the CLFE1UTP. The link LED on the 10/100 connector should be ON to indicate proper connection between the camera and the CLFE1UTP. Ethernet SwITCh/NVR-END InstaLLation (CLFE1UTP) S1 S2 S3 Set the S2 Master/Slave dip switch to OFF for Slave mode Set the S1 and S3 dip switches to match the setting on the camera-end. S1 S2 S3 S4 S1 S2 S3 S4 Off On 1-p 4-P 10 100 CLFE4UTP, CLFE8UTP and CLFE16UTP: For each channel used, set the appropriate dip switches for each channel to match the camera end. Note: Multichannel units are preset to Slave mode. No adjustment required. For systems not utilizing PoE, connect the 12V Power Supply to the power connector of the selected. Connect the RJ-45 connector of the Ethernet switch to the 10/100BaseT Ethernet port of the selected using a standard Cat5/6 cable, 100m length (max). Connect one end of the long UTP cable to the RJ-45 connector of the selected. The Link LED on the 10/100 Ethernet connector should be ON to indicate proper connection between the switch and the selected. The Link LED (Red for 100BaseT, Green for 10BaseT) will be ON and not flashing to indicate confirmed connection between the CLFE1UTP and selected extenders. PAGE 6

FIGURE 7 POWER LED INDICATORS POWER RED OFF Power is on Power is off FIGURE 7 EXTENDED LED INDICATORS TRAFFIC (Extended) 10/100BaseT GREEN Connection is OK, 10BaseT mode YELLOW Flashing, Traffic present RED Connection is OK, 100BaseT mode OFF No traffic FIGURE 8 ETHERNET LED INDICATORS GREEN TRAFFIC (Standard) Flashing Connection is OK with traffic Link YELLOW Connection is OK OFF No connection No connection PAGE 7

MECHANICAL INSTALLATION INSTRUCTIONS INSTALLATION CONSIDERATIONS The CLFE1UTP and CLFE4UTPare supplied as Standalone modules. The CLFE8UTP and CLFE16UTP can be installed as Standalone modules or can be rack-mounted with the addition of the provided 19-Inch Rack-Mounting Ear Brackets. Figure A Dimensions are for the CLFE1UTP standalone ComNet module 1.6" (4cm) 1.15" (3cm) 1.6" (4cm) 3.73" (9.5cm) Figure B Dimensions are for the CLFE4UTP standalone ComNet module 3.3" (8.4cm) 1.6" (4cm) 3.6" (9.2cm) Figure C Dimensions are for the CLFE8UTP and CLFE16UTP ComNet modules 3.25" (8.25cm) 17" (43.2cm) 1.75" (4.45cm) PAGE 8

MECHANICAL INSTALLATION INSTRUCTIONS Read and keep these directions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a dry cloth. Install in accordance with the manufacturer s instructions. This installation should be made by a qualified service person and should conform to all local codes. DO NOT bundle UTP or Coax signals in the same conduit as high-voltage wiring. To reduce the risk of fire or electrical shock, do not expose these products to rain, moisture, dripping or splashing. No objects filled with liquids, such as vases, shall be placed on the equipment. DO NOT install the unit in a place where the operating ambient temperature exceeds 75ºC. Make sure that the external power supply output voltage is in the recommended range. Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including DVRs) that produce heat. Protect the power cord from being walked on or pinched, particularly at the power source, convenience receptacles and the point where they exit from the apparatus. Only use attachments/accessories specified by the manufacturer. Unplug this apparatus during lightning storms or when unused for long periods of time. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when a power supply cord or plug is damaged, liquid has been spilled, objects have fallen inside the apparatus, the apparatus has been exposed to rain or moisture, do not operate normally or has been dropped. The main plus is used as the disconnect device and shall remain readily operable. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus. WARNING: This apparatus is a Class I product. This product must be connected to a mains socket outlet through an AC to DC power supply. WARNING: The mains plug is used as the disconnect device and shall remain readily operable. WARNING: For non-poe applications, unit is to be connected to a mains socket outlet through a Listed Class I power supply rated 12 VDC or 24 VAC. 3 CORPORATE DRIVE Danbury, CT 06810 USA T: 203.796.5300 F: 203.796.5303 TECh SUPPORT: 1.888.678.9427 info@comnet.net 8 TURNBERRY PARk ROAD GILDERSOME MORLEY LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 F: +44 (0)113 253 7462 info-europe@comnet.net 2012 Communications Networks Corporation. All Rights Reserved. ComNet and the ComNet Logo are registered trademarks of Communication Networks, LLC. PAGE 9