ALL STAINLESS STEEL CASING SPACERS



Similar documents
TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION STORM DRAINAGE SYSTEM

Green Thread Product Data

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Wastewater Capital Projects Management Standard Construction Specification

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

SPR PE Steel Reinforced Liner

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

Section 2100-Trenching and Tunneling

TECHNICAL SPECIFICATION

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

INDEX. Sec. No. Items Page Nos.

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

ROOF DRAINS TABLE OF CONTENTS

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

James M. Pleasants Company

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

SECTION POLYVINYL CHLORIDE (PVC) PIPE

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

COATING & WRAPPING OF UNDERGROUND PIPING

JCM GENERAL PRODUCT DIRECTORY Effective March 1, 2010 Replaces 01/12/2007


SECTION 1 GENERAL REQUIREMENTS

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

FLEX-WRAP Foam Pipe Wrap

Packaged Terminal Air Conditioner Wall Sleeve Installation

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

Super Slider ADJUSTABLE FROM Model #HD26229

Application Guide. Compensators Hose Assemblies Expansion Joints FLEX-WELD INCORPORATED FLEX-WELD.COM. Manufactured By:

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SECTION PRECAST CONCRETE UTILITY STRUCTURES

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

SECTION DUCTILE IRON PIPE AND FITTINGS

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

DIVISION 4300 STORM DRAINAGE

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Installation Instructions Hustler 6-BTV Trap Vertical

Section SEWER PIPE INSTALLATION AND TESTING

SECTION DUCTILE IRON PIPE AND FITTINGS

RT-200 HI-TEST ROPE TESTER

WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

METHOD OF STATEMENT FOR STATIC LOADING TEST

Secondary Containment Comparison ATI Ultra COAT vs HDPE

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL Pre-Insulated Piping

TITANIUM FABRICATION CORP.

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

HYLINER AKS HDPE LINING

Section Installation of pipe and casing for sanitary sewer by methods of augering.

PTFE Slide Bearings 04/10 149

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

39HQ Airovision Air Handling Units

RING JOINT SYSTEMS 207

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

CHAPTER 6 - SANITARY SEWER

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

SECTION UNDERGROUND ELECTRIC SERVICE

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

Royal Seal Gasketed Sewer Pipe

SANITARY SEWER SPECIFICATIONS

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Pipe Clamps and Accessories

I BEAM TRACK INSTALLATION

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Mounting Instructions for SP4 Power Modules

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

ASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

Flowtite Jacking Pipe

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

ECM-D70T / ECM-D70T1.5

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH BLACK & GALVANIZED STEEL PIPE

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

With over 100 years of conveyor pulley experience, Baldor Dodge can be trusted to keep your conveyors running.

Embedded Parts Introduction - Anchors

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

Transcription:

ALL STAINLESS STEEL CASING SPACERS The Standard of Excellence in the Industry Position pipe within casing under roadways, railroads, bridges, and canals. Ideal for sliplining. 1213 BADGER STREET YORKVILLE, ILLINOIS 60560 (630) 553-0840 (800) 426-4301 FAX (630) 553-0181 www.cascademfg.com 2007 Cascade Waterworks Mfg.

CASING SPACER INSTALLATIONS LOW COEFFICIENT OF FRICTION 48" DIP into 60" Casing, 110' up 10% Grade Owner: Cobb Marietta Water Authority, Hwy 41 Transmission main Engineer: Welker and Associates Contractor: John D. Stephens Contractor planned on a full day with a wench cable to pull, jacking equipment to push, plus a 7 man crew. With CASCADE S spacers the entire 110' was installed in 1 hour 45 minutes using only a back hoe. CORRECTING FOR GRADE 8" DIP into 24" casing, 380' gravity sewer. Owner: City of Atlanta Engineer: Dept. of Pollution Control Contractor: Newell Bore for casing turned up and lost 8" of grade over last 90'. CASCADE provided numbered spacers that when installed in sequence, brought the carrier back to grade. Spacers are also field adjustable. CENTERING 54" steel into 72" and 64", CMP casing, 200' Owner: City of Seattle Tolt River Pipeline Engineer: CH 2 M Hill Contractor: Frank Coluccio CASCADE spacers center the carrier within the casing to maintain alignment and restrain carrier against floatation or other movement. PVC INSTALLATION-RESTRAINING 30" Vylon PVC into 48" casing, 750' gravity sewer Owner: Engineer: Trinity River Authority Contractor: Pate Bros. McDonald and Associates Spacers placed on spigot end at limit line for Bell insertion. When assembled, spacer pushes Bell relieving stress and reducing chances of telescoping pipes. Spacers maintain proper flow line while restraining against floatation. 2

THE CASCADE SYSTEM The CASCADE Casing Spacer system replaces the old method of banding wooden skids to the carrier pipe with steel straps. Compare CASCADE S method with the obsolete one. In addition to the typical positioning design shown on this page, CASCADE has also developed designs for: Placing multiple carriers within one casing Positioning thermally insulated pipe without damage to insulation Centering small carriers within large casings Positioning gravity sewer to on grade requirements CASCADE FEATURES Lowest coefficient of friction in the industry easy to push High corrosion resistance eliminate backfill Dielectric insulator cathodic protection Design flexibility position carrier positively Simple to use trouble free insertion CASCADE All stainless Steel Casing Spacers are the state of the art system for inserting pipes within pipes. The old method of strapping on and greasing wooden skids is obsolete. Compare CASCADE S system with the antiquated wooden skids... CASCADE ALL STAINLESS STEEL CASING SPACERS Easily attached by a single person. No special tools needed. Slide into casing with minimum pushing force. Low coefficient of friction lets runners glide over rough spots insuring trouble free insertion. Lowest Coefficient of Friction in the Industry. High Corrosion Resistance 100% chemically passivated; Dielectrically insulates carrier and holds securely without any backfill. No Backfill Lowers construction costs and allows for future access. WOODEN SKIDS AND STRAPS Require at least two sets of hands to attach. Cumbersome, time consuming, greasy. Notching and banding tools needed. Hard to push. Catch on weld beads. Carrier rotates. Joints are destabilized. Binding can break straps or skids, making removal and reinsertion necessary. Corrodes. Requires backfill to insure long term stability. Allows bacteria to concentrate. Backfill of sand, gravel, or grout is expensive and makes future access difficult or impossible. WHY CASCADE? EXPERIENCE CASCADE IS THE LEADER in casing spacers for the water and sewer industry with literally thousands of successful installations across the nation. CASCADE has worked with every type of pipe used in water and sewer systems. New challenges are welcome, but chances are if it is a water or sewer application - we ve already done it. QUALITY CASCADE is the leader in quality as well as experience from the liner to the runner - inside to out - there is no corner cutting. Each component material was carefully selected so that the product would be top notch - the best available. Imitators make cheaper products - not equal products. 3

THE CASCADE SYSTEM BASIC POSITIONS Standard: Assists installation and carries slip joint bells at least.75" off casing wall. Maintains dielectric insulation. No restraint against movement such as floatation or surge pressure bucking. Centered & Restrained: Positions carrier in center of casing. Provides restraint against movement. Best for mechanically restrained pipe joints. Restrained: Keeps carrier at bottom of casing while restraining against movement. Multiple & Restrained: Reduces bores under highway. CASING SPACER PLACEMENT DIAGRAM TYPICAL STEEL/D.I. CARRIER TYPICAL PLASTIC CARRIER SPECIFYING SPACER WIDTH & PLACEMENT INTERVALS When deciding the width and placement intervals of CASCADE spacers, the main concerns are pipe stiffness, joint stability, height of separation between carrier and casing, and live load. Generally, stiffer pipe can be supported adequately at greater intervals than more flexible pipe. Casing pipes have deflections, ridges, or otherwise uneven surfaces. Care should be taken to maintain joint stability during, as well as after, installation. Unless special circumstances exist, CASCADE recommends 8 wide spacers at 10 intervals on sizes up to 48 pipe. Pipes over 48 O.D. should be supported with 12 wide spacers. For ductile iron carrier pipes, 10 intervals are the adequate through 60 O.D. For steel carrier pipes, 8 intervals are adequate through 60 O.D. For 24 and larger pipe with the separation between carrier and casing greater than 5 inches, 6 intervals and/or 12 wide spacers should be considered. All variations of PVC pipes (sewer, C-900 and thinner wall PVC) need support at closer intervals and should be supported every 6. Polyethylene pipes vary widely in the interval required and depends on the wall thickness and the maximum allowable deflection between supports. The pipe manufacturer should be consulted if intervals longer than 6 are desired. Concrete and prestressed concrete cylinder pipe require shorter intervals. Always use Model CCS-ER Spacers. In all instances, a spacer should be placed so as to support the carrier within 2 of the end of the casing pipe. Please consult Cascade if there are any special conditions or if any questions arise. For multiple pipe Casing Spacers, consult factory. 4

THE CASCADE SYSTEM SAMPLE DRAWINGS MULTIPLE CARRIERS TUNNEL LINER DUAL CARRIERS CORRECTING FOR GRADE CENTERED CONFIGURATION RESTRAINED CONFIGURATION 5

ORDERING INFORMATION RUNNER RISER RIBBED LINER SHELL TYPICAL DATA RUNNERS MATERIAL SPECIFICATIONS SHELL - RISERS - FASTENERS - LINER - RUNNERS - Minimum 14 gauge T-304 stainless steel. All surfaces are fully chemically passivated. Flanges are ribbed for strength. Max 10 ga. T-304 stainless steel, reinforced 6" and over height. 5/16-18 T-304 stainless steel PVC -.090 thick, 85-90 durometer (ASTM D1706-61T) - 80 Max constant operating temperature - 150 F (64 C) Electrical properties - (ASTM - D149-61) 1380 V/min. Resistance: Salt Spray (ASTM - B117) - Excellent Acids - Good Ultra High Molecular Weight Polyethylene Low coefficient of friction High resistance to abrasion and sliding wear Toughness under impact Low deflection under compression Dielectric insulation PROPERTY ASTM METHOD UNITS VALUE Specific Gravity D-792 gm/cc.934 Tensile Strength (Break) D-638 PSI 3500 Elongation (Break) D-638 % 380 Izod Impact D-256 ft.-lbs/in. of NO notch BREAK Hardness D-2240 Shore D 67 Coefficient of Friction D-1894.11-.13 Heat Distortion Temp. 66PSI D-648 C 88 Coefficient of Thermal Expansion D-696 F -1 2 X 10-4 ELECTRICAL PROPERTIES ASTM METHOD UNITS VALUE Dielectric Constant D-150 2.3 Dissipation Factor 60 cycles to 10 6 cycles D-150 <.05 x 10 3 Volume Resistivity@23-c D-257 ohm,cm >10 10 Surface Resistivity D-257 ohm >10 16 Dielectric strength D-148 KV/CM 900 ABRASION CHARACTERISTICS Taber Abrasion D-1044 Mg/loss Nil Sand Slurry* 7 * Sand Slurry condition - 7 hours in one part water at 1725 RPM. Carbon Steel = 100. UHMW 1900 = 15. Lower value more resistant to abrasion. EXAMPLES 1) Carrier - 12" DIP or C-900 PVC Casing - 24" Steel -.375 wall Spacer Width - 8" Configuration - Centered CCS 1320-8 / C23.25 CTR 2) Carrier - 48" Steel Casing - 66" concrete Spacer width - 12" Configuration - Restrained CCS 4800-12 / C66 RES 3) Carrier - 6" SCH 40 PVC Casing - 16" Steel.25" wall Spacer width - 8" Configuration - Standard CCS 663-8 / C15.5 STD RISER/RUNNER HEIGHTS FOR STANDARD SPACERS 2" Height through 10" pipe size. 2 1/2" Height through 48" pipe size. 3" through 64" pipe NUMBER OF RISER / RUNNERS REQUIRED FOR STANDARD SPACERS 4 Runners through 24" pipe size 6 Runners through 36" pipe size 8 Runners through 48" pipe size CASCADE provides drawings for approval on all special applications. IMPORTANT WHEN ORDERING CASING SPACERS, PLEASE HAVE THE FOLLOWING INFORMATION AT HAND: Job Name/Engineer s Name Type and O.D. of carrier pipe Type of joint Type and I.D. of casing pipe Length of casing or quantity of spacers needed Configuration Requirement: Standard, Centered, or Restrained; any special installation requirements 6

CASCADE SPECIFICATIONS STYLE CCS CASING SPACERS Casing spacer shall be a two-piece shell per carrier pipe and made from T-304 stainless steel of a minimum 14 gauge thickness. Each shell section shall be lined with a 0.090 thick, ribbed PVC extrusion with a retaining section that overlaps the edges of the shell and prevents slippage. Bearing surfaces (runners) shall be ultra high molecular weight polyethylene (UHMW) to provide abrasion resistance and a low coefficient of friction (0.12). The runners shall be attached to support structures (risers) at appropriate positions to properly support the carrier pipe within the casing pipe and to ease installation. The runners shall be mechanically bolted to the riser. The bolt heads are welded to the inside of the risers for strength. Risers shall be made of T-304 stainless steel of a maximum 10 gauge. All risers shall be MIG welded to the shell. Bottom risers 6 and over in height shall be reinforced. All reinforcing plates shall be 10 ga. T-304 stainless steel and shall be MIG welded to mating parts. Standard positioning within the casing pipe shall be sized such that the carrier rests near the bottom of the casing pipe and the height of the risers and runners are to provide a bottom clearance not less than onehalf inch between the casing pipe and the extreme outside diameter of the joint (bell, seam weld, joint clamp,...) of the carrier pipe. Centered & Restrained positioning within the casing pipe shall be sized such that the height of the risers and runners are to center the carrier pipe in the casing pipe with a top clearance of three-fourths inch minimum. Restrained positioning within the casing pipe shall be sized such that the carrier rests near the bottom of the casing pipe and the height of the risers and runners are to provide a bottom clearance not less than one-half inch between the casing pipe and the extreme outside diameter of the joint (bell, seam weld, joint clamp,...) of the carrier pipe and a top clearance of three-fourths inch minimum. Multiple Carrier pipes within the casing pipe shall be sized such that the carrier pipes are held at fixed distances relative to each other, with the height of the risers and runners to provide not less than three-fourths inch between the casing pipe and the outside diameter of the riser/runner combinations. Special reinforcing plates may be required to stabilize and support structure. All welds and metal surfaces shall be chemically passivated. Due to the numerous application possibilities, consult factory for spacing requirements. Casing spacers shall be Model CCS as manufactured by Cascade Waterworks Mfg. Co. of Yorkville, IL or approved equal. STYLE CCES CASING END SEALS RUBBER SEAL CASCADE Model CCES End Seals pull over the casing and carrier pipes after installation to provide a barrier to backfill debris and seepage. STAINLESS STEEL BAND MATERIAL SPECIFICATIONS: SEAL - Neoprene - Other compounds available BANDS - T-304 Stainless Steel Cascade s Runners can be replaced in the field if bore is offgrade or installation is not to design. REINFORCED RISER 7

SPECIFICATIONS STYLE CCS-ER CASING SPACERS (EXTENDED RANGE) Pipe 36 Diameter and Up Casing spacer shall be made from T-304 stainless steel of a minimum thickness of 14 gauge. Each shell section shall be a maximum of 12 wide, and shall be a two-piece design. Each shell section shall have a stud bar and receiver bar TIG welded to the shell. Studs shall be T-304 and threaded as 5/8-11x7 long. Each stud bar shall include up to three studs, and shall allow a maximum of 1 adjustment to circumference to compensate for the variations in large diameter (non-uniform) pipe. The shell shall be lined with a 0.090 thick, ribbed PVC extrusion with a retaining section that overlaps the edges of the shell and prevents slippage. Bearing surfaces (runners) shall be ultra high molecular weight polyethylene (UHMW) to provide high abrasion resistance and a low coefficient of friction (0.12). The runners shall be attached to support structures (risers) at appropriate positions to properly support the carrier within the casing and to ease installation. The runners shall be mechanically bolted to the riser. The bolt heads are welded to the inside of the risers for strength. Risers shall be made of T-304 stainless steel of a maximum 10 gauge. Bottom risers 6 and over in height shall be reinforced. All risers shall be MIG welded to the shell. Standard positioning within the casing pipe shall be sized such that the carrier rests near the bottom of the casing pipe and the height of the risers and runners are to provide a bottom clearance not less than one-half inch between the casing pipe and the extreme outside diameter of the joint (bell, seam weld, joint clamp,...) of the carrier pipe. Centered & Restrained positioning within the casing pipe shall be sized such that the height of the risers and runners are to center the carrier pipe in the casing pipe with a top clearance of three-fourths inch minimum. Restrained positioning within the casing pipe shall be sized such that the carrier rests near the bottom of the casing pipe and the height of the risers and runners are to provide a bottom clearance not less than one-half inch between the casing pipe and the extreme outside diameter of the joint (bell, seam weld, joint clamp,...) of the carrier pipe and a top clearance of three-fourths inch minimum. All welds and metal surfaces shall be chemically passivated. Due to the numerous application possibilities, consult factory for spacing requirements. Casing spacers shall be Model CCS-ER as manufactured by Cascade Waterworks Mfg. Co. of Yorkville, IL or approved equal. WARRANTY Cascade Waterworks Mfg. Co. warrants its product(s) for one year from the date of shipment to be free of defects in material or workmanship. Cascade will repair or replace this product if it is found to be defective within the above stated one year warranty period provided that the buyer submits his claim in writing and delivers the original claimed defective product in its entirety, freight prepaid to Cascade Waterworks Mfg. Co., 1213 Badger Street, Yorkville, IL, 60560 for inspection within 30 days. Written notice or products sent to Mfg. Reps or any other agents will not be honored as valid warranty claims. Cascade is not liable or responsible for any loss, damage or injury to any person(s) or property directly or indirectly arising from the use or inability to use this product. The user shall determine the suitability of the product for its intended use prior to any application and said user assumes all risks in connection with the use of this product. No claims for labor or damage will be allowed. Buyer must advise Cascade within 30 days of discovery of the alleged defect or the claim will be barred. This warranty is exclusive and in lieu of all others, whether written, oral or implied. Upon the product(s) purchase from Cascade Waterworks Mfg. Co., or any of its Agents, the purchaser agrees to all of the above terms of warranty. 04/07 8