Respirator Selection for Diisocyanates



Similar documents
3M Service Life Software United States

JobHealth Highlights Technical Information for Occupational Health and Safety Professionals

RESPIRATORY PROTECTION PROGRAM

NIOSH Respirator Selection Logic. Author: Nancy Bollinger, M.S.

Cartridge Change Schedule

OH&ESD. Regulations. Update. #21 Respiratory Protection page 1 of 8

If you regularly wear a respirator on the job, OSHA requires your employer to provide:

3M Personal Safety Division 3M Center, Building W-75 St. Paul, MN, USA

NIOSH approval labels key information to protect yourself By R. Metzler and J. Szalajda

Respiratory Safety and PPE Module 7. Special Warehouse Worker Hazards in Structural Steel Fabricating and Supply Companies

Respiratory Protection in the Workplace. A Practical Guide for Small-Business Employers

DEVELOPING A CODE OF PRACTICE FOR RESPIRATORY PROTECTIVE EQUIPMENT

3M Personal Safety Division E C O R D. Cartridge. Filter. and. Guide. User Information to Help Optimize Protection

Pancreatin. Ingredient CAS No Percent Hazardous

Safety Data Sheet SOMAmer Reagent

7500 Series. Important: Keep these user instructions for reference.

SCBA Frequently Asked Questions

Material Safety Data Sheet

SAFETY DATA SHEET FILE NO.: , DRY CIDER VINEGAR SDS DATE: 05/05/15

Safety Data Sheet. Product #: Aspira Scientific 521 Cottonwood Dr. Milpitas, CA

NFPA Hazard Class: * Physical Form: Solid. Health: 0 (Least) * Appearance: Yellow Flammability: 1 (Slight)

Ingredient CAS No Percent Hazardous Aluminum Oxide % Yes

WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA-D

Loss Control TIPS Technical Information Paper Series

Lead Monitoring / Removal

Questions and Answers (Q&A) about OSHA s National Emphasis Program (NEP) Occupational Exposure to Isocyanates

3M Automotive Respirators And Safety Products

MSDS (Material Safety Data Sheet)

Material Safety Data Sheet

University of Tennessee Safety Program

MATERIAL SAFETY DATA SHEET 3M(TM) Marine Adhesive Sealant 5200, 5210 Tan; PN 06501, 6501E 08/21/09

MATERIAL SAFETY DATA SHEET according to the (US) Hazard Communication Standard (29 CFR )

Revision Date 01/26/2012 Print Date 01/26/2012

Material Safety Data Sheet

Confined Space Air Monitoring

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

: Resin Fibre Discs - Aluminum Oxide, Zirconia Alumina

Material Safety Data Sheet. Chemical Product and Company Identification Product Name or Number:

SAFETY DATA SHEET Glen-Pak TM DNA purification cartridge (for use with disposable syringes) xx

Oregon OSHA s guide to. developing a respiratory protection program for small-business owners and managers

EOSMS 204C Effective Date: 12/8/2014 Page 1 of 8

Material Safety Data Sheet

Sodium Aluminum Tetrafluoride

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 08/25/2011

Safety Data Sheet. SECTION 1: Identification. SECTION 2: Hazard identification

DOW CORNING CORPORATION Material Safety Data Sheet

The University will meet or exceed the legislated requirements made under the Alberta Occupational Health and Safety Act, Regulation and Code.

Revision Number: Issue date: 02/14/ PRODUCT AND COMPANY IDENTIFICATION 2. HAZARDS IDENTIFICATION PICTOGRAM(S) None

EMERGENCY PHONE: or (651) (24 hours)

Reducing Roofers Exposure to Asphalt Fumes

Material Safety Data Sheet. Calcium Lactate

Why and when to replace your 3M Filters!

Carpet Seam Sealer 8200

Occupational Health and Safety. Bulletin. Respiratory Protective Equipment: An Employer s Guide

Material Safety Data Sheet BZK Antiseptic Towelettes / Wipes

Subpart E Personal Protective And Life Saving Equipment

WINDEX MULTI-SURFACE CLEANER - VINEGAR

Spartan Chemical Company, Inc. Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET High Pressure Laminate Fire Retardant

MODEL FIRE DEPARTMENT RESPIRATORY PROTECTION PROGRAM

MATERIAL SAFETY DATA SHEET

Personal Protection Equipment for Mold Remediation

DIAMOND POWDER - MICRON

CeramClean II Aluminum Safe

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

WORKPLACE EXPOSURE LIMITS

MATERIAL SAFETY DATA SHEET 3M Super 33+ and Super 88 and 37 and 15 Vinyl Electrical Tape-No Lead 12/02/10

MATERIAL SAFETY DATA SHEET 3M Scotch-Brite Durable Flex (DF) Belts, A FIN, A MED, A CRS 01/13/12

MATERIAL SAFETY DATA SHEET COPPER ALLOYS 101, 102, 103, 104, 110, 122, 151, XP5

WINDEX COMMERCIAL LINE GLASS CLEANER WITH AMMONIA- D

Wildfire Smoke and Your Health

# 228 Fit Testing: Frequently Asked Questions

Material Safety Data Sheet

IDENTIFICATION Sodium Perchlorate is a white sand-like solid. It is used in explosives, jet fuels, as a medication, and to make other chemicals.

SAFETY DATA SHEET. 955 Connecticut Ave, Suite 5202 Bridgeport, CT Tel: Date Prepared: July 22, 2015

Safety Training Topic PERSONAL PROTECTIVE EQUIPMENT

MATERIAL SAFETY DATA SHEET. Rainguard The Professionals Choice Advanced Waterproofer

Material Safety Data Sheet

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR HAZARD COMMUNICATION SECTION: 1700 REVISION DATE: 2/3/2012 REVISION: 4 NUMBER:

PATHWAYS DRAIN TREATMENT. Use only for the purpose on the product label.

MATERIAL SAFETY DATA SHEET


MATERIAL SAFETY DATA SHEET. 1. Product and Company Identification. 2. Hazards Identification

TREMPRO 638 SSL GRAY - 15 SSG CS Version 3. Print Date 12/22/2011 REVISION DATE: 12/20/2011

Material Safety Data Sheet SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

Transcription:

August 2009 Vol. 26. No. 7 Respirator Selection for Diisocyanates This article was originally published in 3M s JobHealth Highlights Volume 18, Number 2, 2000, written by Larry Janssen, C.I.H. Revised by Scott Shinn, C.I.H. in August 2009 Scott Shinn, C.I.H. Scott Shinn is a Certified Industrial Hygienist with 3M OH&ESD Technical Service and Regulatory Affairs. Introduction The Occupational Safety and Health Administration (OSHA) respiratory protection regulation 29 CFR 1910.134 requires employers who use gas or vapor air-purifying respirators to develop cartridge change schedules based on objective information or data. (1) This provision applies whether or not the contaminant has adequate warning properties. OSHA says this very clearly in its compliance directive for 1910.134, which states, Where an effective change schedule is implemented, air-purifying gas and vapor respirators may be used for hazardous chemicals, including those with few or no warning properties. (2) While no chemicals are exempt from the regulation or the compliance directive, some users are still uncertain whether air-purifying respirators can be used for the common diisocyanates such as toluene-2,4-diisocyanate (TDI), hexamethylene-1,6-diisocyanate (HDI) and methylene bisphenyl isocyanate (MDI). OSHA has clarified its position on this issue in a letter dated July 18, 2000 that indicates air-purifying respirators may be used if all requirements of 1910.134 are met and other potential hazards are addressed. The letter is available at http://www.osha.gov.

Discussion Prior to the revised OSHA Respiratory Protection Standard effective April 8, 1998 supplied-air respirators were used to help reduce exposures to the common diisocyanates. This was appropriate, since OSHA s original respiratory protection regulation used a decision logic that only allowed airpurifying respirators to be used for gases or vapors with adequate warning properties. A contaminant is said to have adequate warning properties if it has persistent odor or irritation effects at concentrations at or below the exposure limit. (3) Reported odor thresholds for the diisocyanates range from two to more than ten times their exposure limits. (4,5) Therefore, the diisocyanates have poor warning properties and supplied-air respirators were required. Now air-purifying respirators may be used for compounds with poor warning properties if a cartridge change schedule is set up. If the respiratory protection regulation requires cartridge change schedules to be used instead of reliance on warning properties, why have some been concerned about the suitability of air-purifying respirators for the diisocyanates? It seems that their concerns are based on one or more of four misconceptions: Misconception #1 Air-purifying respirators should not be used because diisocyanates have poor warning properties. Although OSHA specifically permits change schedules in lieu of sensory warning properties, some argue this is not a safe practice. They believe diisocyanates could enter a facepiece through a spent cartridge or defect (e.g., a torn exhalation valve) and the user would be unaware, risking prolonged exposure. In reality, this potential exists for any gas or vapor with poor warning properties and for all particulate contaminants. In addition, the fact that a contaminant has adequate warning properties does not ensure that all respirator users will be able to detect it at or below the exposure limit. Because odor thresholds are median values for a population, more than half of individuals will not detect the odor until the level is above the reported odor threshold. (3) A sound respiratory protection program minimizes the risk of undetected exposure by assuring that respirators are properly fitted, maintained and worn, and that cartridges are changed at appropriate intervals.

Misconception #2 Air-purifying respirators cannot remove diisocyanates. diisocyanates are adsorbed by activated carbon and retained extremely well In fact, it has been known for many years that diisocyanates are adsorbed by activated carbon and retained extremely well. (6,7) Cartridge breakthrough equations predict very long service lives for the diisocyanates under plausible use conditions. If a diisocyanate is the only air contaminant present, a cartridge change schedule will most likely be based on general hygiene and maintenance considerations rather than breakthrough concerns. If other organic vapors are present in the same atmosphere as a diisocyanate, those vapors invariably break through first. Cartridge change schedules will be established using predicted breakthrough of the other contaminant(s). It must be recognized that diisocyanates may form condensation aerosols when they are airborne. For this reason, it is generally necessary to use a particulate filter in combination with an organic vapor cartridge. Misconception #3 Air-purifying respirators are not approved for gases and vapors with poor warning properties. The National Institute for Occupational Safety and Health (NIOSH) supports OSHA s requirement for change schedules and recommends against reliance on warning properties. (8) In addition, NIOSH directed respirator manufacturers to change the cautionary language previously used on cartridge and canister approval labels and user instructions to be consistent with 1910.134. Specifically, the statement Do not wear for protection against organic vapors with poor warning properties or those which generate high heats of reaction with sorbent was changed to Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters are replaced before breakthrough occurs. (9) This cautionary language must appear on labels for all gas and vapor respirators sold after July 1, 2001.

Misconception #4 Air-purifying respirators should not be used because diisocyanates are sensitizers or are too hazardous. Subscribe If you would like to be notified by email when each new issue becomes available, register at www.3m.com/jhh For more information, please contact Health and Safety Services Technical Assistance: 1-800-243-4630 Internet sites: www.3m.com/occsafety www.respexam.com There is no doubt the effects of diisocyanate overexposure can be serious, particularly in individuals who become sensitized. However, this reasoning is contrary to accepted respirator decision logic. By definition, no respirator is required when exposure to an air contaminant is below the exposure limit. The purpose of a respirator is to reduce an exposure that is above an exposure limit to an exposure that is below that limit. The diisocyanates have exposure limits. Any respirator that reduces a diisocyanate overexposure to a concentration below its exposure limit is acceptable. NIOSH changed its long-standing policy of recommending only the most protective respirators (e.g., SCBA) for use with carcinogens to reflect this logic. (10) NIOSH now acknowledges that the entire range of respirators can be considered for protection against carcinogens with exposure limits. The same respirator decision logic is applicable to all air contaminants, including the diisocyanates. Summary When properly selected and used, air-purifying respirators can be used safely and effectively to reduce exposures to the common diisocyanates. Appropriate cartridge change schedules can be developed to ensure cartridges are changed before breakthrough occurs. OSHA is correct in allowing employers to choose air-purifying respirators for diisocyanates if they are appropriate for their workplaces. As is the case with any other air contaminant, a complete respiratory protection program per 29 CFR 1910.134 is necessary to ensure that respirators are selected properly and provide appropriate protection. References 1. Respiratory Protection, Code of Federal Regulations Title 29 (5), Part 1910.134. 1999. pp. 402-427. 2. U. S. Department of Labor/OSHA: Inspection Procedures for the Respiratory Protection Standard. (Directive Number CPL 2-0.120). Washington D.C., 1998.

References, continued 3. National Institute for Occupational Safety and Health (NIOSH): Respirator Decision Logic (DHHS/NIOSH Pub. No. 87-108). Washington, D.C.: U.S. Department of Health and Human Services/NIOSH, 1987. 4. Jensen, B. and P. Wolkoff: VOCBASE: Odor Thresholds, Mucous Membrane Irritation Thresholds and Physio-Chemical Parameters of Volatile Organic Compounds. [Computer Software]. National Institute of Occupational Health, Denmark, 1996. 5. Health Risk Associates: Warning Properties of Industrial Chemicals. Seattle: Health Risk Associates, 1994. 6. Vasta, J.F.: Respirator Cartridge Evaluation for Isocyanate Containing Imron and Centari Enamels. Am. Ind. Hyg. Assoc. J. 46(1):39-44 (1985). 7. Dharmarajan, V., R.D. Lingg, and D.R. Hackathorn: Evaluation of Air- Purifying Respirators for Protection Against Toluene Diisocyanate Vapors. Am. Ind. Hyg. Assoc. J. 47(7):393-398 (1986). 8. U.S. Department of Health and Human Services/NIOSH: NIOSH Respirator Use Policy. August 4, 1999. [Policy Statement]. 9. U.S. Department of Health and Human Services/NIOSH: Letter to All Manufacturers (Approval Label Change). June 16, 2000. [Letter to All Manufacturers]. 10. U.S. Department of Health and Human Services/NIOSH: NIOSH Respirator Use Policy for Protection Against Carcinogens. May 2, 1997. [Policy Statement].