Infectious Waste Disposal Procedure 25 PA Code 284 Ursinus College Collegeville, PA 19426

Similar documents
REGULATED MEDICAL WASTE

Policy for the Disposal of Biological Waste

MEDICAL WASTE DEFINITION OF TERMS HEALTH & SAFETY CODE, PART 14; COUNTY ORDINANCE #7646

Potentially Infectious Medical Waste and Sharps Disposal

Appendix H Managing Biohazardous Waste SOP

Infectious Waste Management Plan

Regulated Medical Waste Generator Inspections An Inspector s View Point

"ADOPTED STANDARDS FOR THE REGULATION OF MEDICAL WASTE" IN HEALTH CARE FACILITIES LICENSED BY THE MISSISSIPPI STATE DEPARTMENT OF HEALTH

Medical Waste Management Plan

MEDICAL WASTE DISPOSAL POLICY. EFFECTIVE DATE: January 31, 1991 REVISED DATE: April 1, 2008 I. AUTHORITY TO ESTABLISH DISPOSAL POLICY:

Connecticut Biomedical Waste (BMW) Requirements (22a ) and Common Industry Practices

INFECTIOUS/BIOLOGICAL WASTE MANAGEMENT PROTOCOL

A Guide to Managing Your Biological Waste at the University at Albany

Appendix H IBC Managing Biohazardous Waste SOP

Medical or Biological Waste: Storage, Treatment, Disposal and Transportation Plan

The University of Texas at San Antonio Office of Environmental Health, Safety and Risk Management. Part A. Biological Waste Management Safety Plan

How To Understand And Understand The Rules Of Hazardous Waste

West Virginia Department of Health & Human Resources Bureau of Public Health Office of Environmental Health Services

Potentially Infectious Medical Waste

Revision 5. Calvin College Medical Waste Management Plan. Date: Health and Safety

Northeastern University Procedure for Disposal of Medical or Biological Waste

APPENDIX D INFECTIOUS WASTE MANAGEMENT GUIDE

UCLA Henry Samueli School of Engineering and Applied Science STANDARD OPERATING PROCEDURE MEDICAL WASTE (BIOHAZARD WASTE) MANAGEMENT

Percentage of the Medical Waste Stream That Is Regulated Medical Waste Microbiological Waste Pathological Waste Blood and Body Fluids

Managing Regulated Medical Waste in New Mexico

MUNICIPALITY OF ANCHORAGE

INSTITUTIONAL POLICY AND PROCEDURE (IPP)

UNIVERSITY OF RICHMOND REGULATED MEDICAL WASTE MANAGEMENT GUIDELINES

Utah Division of Solid and Hazardous Waste Solid Waste Management Program

MEDICAL WASTE MANAGEMENT

BIOHAZARDOUS/MEDICAL WASTE MANAGEMENT PLAN

Biohazardous Waste Management Plan

CITY OF LONG BEACH DEPARTMENT OF HEALTH AND HUMAN SERVICES 2525 GRAND AVENUE LONG BEACH, CALIFORNIA / MEDICAL WASTE GENERATOR PACKET

Biohazardous Waste and Sharps Disposal

From: Chief, Bureau of Medicine and Surgery To: Ships and Stations Having Medical Department Personnel

* * * * * * * * * * * * * * * *

REGULATED MEDICAL WASTE MANAGEMENT. Title 15, Article 27, Environmental Conservation Law (DEC)

A Guide to the Handling and Disposal of Medical Waste Contents

Biohazardous, Medical & Biological Waste Guidance Chart

MEDICAL WASTE MANAGEMENT

Biomedical. Waste Management Guide

Michigan State University Biohazardous Waste Management Plan

MEDICAL WASTE MANAGEMENT PLAN ACCUMULATION SITE(S) FOR UC DAVIS HEALTH SYSTEM SCHOOLS OF HEALTH EDUCATION & RESEARCH

Annual Biomedical Waste Code Training

Biomedical Waste Disposal Procedures

TARLETON STATE UNIVERSITY Biohazardous Waste Program

ENVIRONMENTAL HEALTH DEPARTMENT SAN JOAQUIN COUNTY

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE

Biosafety Level 2 (BSL-2) Safety Guidelines

GWYNEDD MERCY UNIVERSITY. Biohazard Waste Management Plan

DEPARTMENT OF ENVIRONMENTAL HEALTH Office of Solid/Medical Waste Management 1131 Harbor Bay Parkway, Rm. 200 Alameda, CA Tel.

SOLID WASTE MANAGEMENT PROGRAM WASTE MANAGEMENT DIVISION DEPARTMENT OF ENVIRONMENTAL CONSERVATION AGENCY OF NATURAL RESOURCES STATE OF VERMONT

Laboratory Biosafty In Molecular Biology and its levels

REGULATED MEDICAL WASTE MANAGEMENT PLAN

REGULATED MEDICAL WASTE Q & A

Medical Waste Disposal

MANAGEMENT AND DISPOSAL OF BIOLOGICAL WASTE TEXAS A&M UNIVERSITY. July 2003

ENVIRONMENTAL HEALTH, SAFETY & RISK MANAGEMENT. Hazardous Materials &Waste Management Plan at

Health Sciences Campus Biomedical Waste Management Standard Operating Procedure (SOP)

Waste Management Program

Infectious Waste Contingency Plan

Administrative Procedure

Compliance Bulletin Solid Waste Medical Waste Identification reviewed/revised February 2012

2.3. The management in each HCF shall be responsible for ensuring good waste management practices in their premises.

CHAPTER Section 2 of P.L.1989, c.34 (C.13:1E-48.2) is amended to read as follows:

Medical Waste Management Plan

Policies and Procedures Manual Waste Management Plan Policy No. 06:04:00 Page 1 of 12

Guideline C-4: The Management of Biomedical Waste in Ontario

Workshop December, 2014

Medical Waste Management Act

MANAGEMENT AND DISPOSAL OF BIOLOGICAL WASTE AT TEXAS A&M INTERNATIONAL UNIVERSITY

Operating Procedure INFECTIOUS WASTE MANAGEMENT AND DISPOSAL

BIOMEDICAL WASTE MANAGEMENT

(a) Navy Environmental Health Center Pharmaceutical Waste Management Guidelines (b) 29 CFR , Occupational Exposure to Bloodborne Pathogens

THE UNIVERSITY OF MAINE BIOMEDICAL WASTE MANAGEMENT PLAN

History Note:Statutory Authority G.S. 130A ; Eff. Oct. 1, 1990; Amended Eff. April 1, 1993.

Waste Management Program

Each has the following responsibilities under this SOP:

STATE OF RHODE ISLAND AND PROVIDENCE PLANTATIONS DEPARTMENT OF ENVIRONMENTAL MANAGEMENT

UNIVERSITY OF NORTH FLORIDA BIOMEDICAL WASTE MANAGEMENT PLAN DEVELOPED BY: ENVIRONMENTAL HEALTH, SAFETY, INSURANCE & RISK MANAGEMENT

Slide 1. Welcome to the on-line training course for Waste Management!

Bloodborne Pathogens Program Revised July,

UCCS Biosafety Management Policy

INFECTIOUS WASTE MANAGEMENT PLAN Marshall University Robert C. Byrd Biotechnology Science Center

Environmental Health & Occupational Safety 413 Student and Business Services Building, ext MEDICAL WASTE MANAGEMENT PLAN

CLINICAL AND RELATED WASTE OPERATIONAL GUIDANCE

Hazardous and Regulated Waste Management Plan Purpose

Texas Commission on Environmental Quality Page 1 Chapter Municipal Solid Waste

INFECTIOUS WASTE MANAGEMENT PLAN West Virginia School of Osteopathic Medicine, Fredric W. Smith Science Building

CHS Medical Group Hazardous Waste Management In Service

SPECIAL MEDICAL WASTE PROGRAM

NEW HAMPSHIRE CODE OF ADMINISTRATIVE RULES

Tufts Environmental Health and Safety April 2010

RADIATION CONTROL TECHNIQUE #2 INSTRUCTIONS FOR PREPARATION OF RADIOACTIVE WASTE FOR DISPOSAL

HAZARDOUS WASTE MANAGEMENT AT HEALTHCARE FACILITIES

105 CMR: DEPARTMENT OF PUBLIC HEALTH

Compliance Bulletin Solid Waste Medical Waste Generators reviewed/revised February 2012

Biomedical Waste Management Plan

Medical Waste Management Act. January 2015

Biomedical Waste Management Plan

Transcription:

The purpose of the Infectious Waste Disposal procedure is to establish procedures for the safe handling and proper disposal of infectious waste generated at in accordance with regulation 25 PA Code Chapter 284. As a Generator of Infectious Waste, personnel handling such waste must follow the code requirements for storage and labeling of containers, manifests, and recordkeeping. A quick reference checklist follows the procedure in Appendix A. The Environmental Health & Safety Coordinator manages the infectious waste program. I. Definition of Infectious Waste According to regulation 25 PA Code 271.1, Infectious Waste is defined as a municipal and residual waste which is generated in the diagnosis, treatment, immunization or autopsy of human beings or animals, in research pertaining thereto, in the preparation of human or animal remains for interment or cremation, or in the production or testing of biologicals, and which falls under one or more of the following categories: A. Cultures and stocks. Cultures and stocks of infectious agents and associated biologicals, including the following: cultures from medical and pathological laboratories; cultures and stocks of infectious agents from research and industrial laboratories; wastes from the production of biologicals; discarded live and attenuated vaccines except for residue in emptied containers; and culture dishes, assemblies and devices used to conduct diagnostic tests or to transfer, inoculate and mix cultures. B. Pathological wastes. Human pathological wastes, including tissues, organs and body parts and body fluids that are removed during surgery, autopsy, other medical procedures or laboratory procedures. The term does not include hair, nails or extracted teeth. C. Human blood and body fluid waste and items contaminated with human blood and body fluid waste. D. Animal wastes. Contaminated animal carcasses, body parts, blood, blood products, secretions, excretions and bedding of animals that were known to have been exposed to zoonotic infectious agents or nonzoonotic human pathogens during research (including research in veterinary schools and hospitals), production of biologicals or testing of pharmaceuticals. E. Isolation wastes. Biological wastes and waste contaminated with blood, excretion, exudates or secretions from: 1. Humans who are isolated to protect others from highly virulent diseases. 2. Isolated animals known or suspected to be infected with highly virulent diseases.

F. Used sharps. Sharps that have been in contact with infectious agents or that have been used in animal or human patient care or treatment, at medical, research or industrial laboratories, including hypodermic needles, syringes (with or without the attached needle), Pasteur pipettes, scalpel blades, blood vials, needles with attached tubing, culture dishes, suture needles, slides, cover slips and other broken or unbroken glass or plasticware. II. Storage Requirements Infectious waste must be stored in a manner that: A. Maintains the integrity of the container, prevents the leakage or release of waste from the containers and provides protection from water, rain and wind. B. Prevents the spread of infectious agents. C. Affords protection from animals and does not provide a breeding place or a food source for rodents. D. Maintains the waste in a nonputrescent state, using refrigeration (<=7 o C) or freezing (<=-18 o C) when necessary. E. Prevents odors from emanating from the container. F. Prevents unauthorized access to the waste. III. Containers A. In general, containers must be 1. Leak proof 2. Impervious to moisture. B. Sharps containers must be 1. Rigid. 2. Tightly lidded. 3. Puncture resistant. C. Re-use 1. Nonrigid containers may not be re-used. 2. Corrugated fiberboard containers may be re-used if the surface of the container has been protected from direct contact with the waste. 3. Rigid, fiberboard containers may be re-used if the container has been properly disinfected according to DEP guidelines or the surface of the container was protected from direct contact with the waste.

D. Bags IV. Labeling If bags are used as the only storage container, 1. Use double or multiple bags. 2. Securely tie the bag. 3. Ensure the bags are constructed of material that meets ASTM standard D1709-91 and D1922-89 by should be stamped on the bag or the box of the packaged bags. 4. Ensure the bags have sufficient seam strength equal in resistance to tearing and equally as impermeable as the other parts of the bag. 5. The bags must be fluorescent orange, orange-red, or red in color and labeled per regulations. A. The outermost container for each infectious waste package for off-site transportation must be immediately labeled: 1. Label must be securely attached and legible. 2. Indelible ink used to complete the information on the label. 3. If handwritten, 3 x 5 in size. B. Label information must contain the following: a. Name, address, and telephone number of generator. b. Date the waste was generated. c. Name of transporter. C. The outermost container or bag for each infectious waste package for either onsite or offsite movement must contain the following information: a. The words infectious waste. b. Universal biohazard symbol c. Date waste was generated V. Duration of storage A. Infectious waste, excluding sharps, may be stored at room temperature or in a refrigerator until the storage container is full, but no longer than 30 days from the date waste was first placed in the container. B. A filled infectious waste container may be stored in a freezer for up to 90 days after the date waste was first placed in the container. C. If waste becomes putrescent during the storage period, it must be removed off-site within 24 hours for processing or disposal.

D. Used sharp containers may be used until full and no longer than 1 year providing the container meets the general storage requirements; however, the best practice is to remove sharps containers when the containers are 2/3-3/4 full. VI. Waste Removal During the semester, infectious waste should be picked up once a month. The Environmental Health & Safety Coordinator communicates the monthly scheduled pickup dates during the academic year; other times, pickups are on a will call basis. Contact the Environmental Health & Safety Coordinator at 610-409-3221. VII. Recordkeeping Manifests: The signer of the manifest must ensure all information is correct before signing. The signer will be the one contacted by the DEP in the event of an issue with the waste. A. The following information must be on the manifest: 1. Name, mailing address and telephone of the generator 2. Total number of pages. 3. Each transporter s company name, identification number, PA infectious and chemotherapeutic waste transporter license number and telephone number. 4. Number of containers, types of containers, and the total quantity of the waste by weight or volume. 5. Infectious waste code number for each waste indicated on manifest. 6. United States Department of Transportation proper shipping name, hazard class and identification number for each waste, if applicable. 7. Special instructions and information necessary for proper handling of the waste during transportation, shipping, storage, or disposal, if any. 8. The printed or typed name of the handwritten signature of the generator s authorized representative, and the date of shipment. 9. The printed or typed name and handwritten signature of the initial transporter s authorized representative, and the date of receipt. 10. The designated facility s name, site address, Pennsylvania State permit or identification number and phone number. 11. An authorized representative of the generator shall ensure that the manifest has been completed and shall read the certification statement on the manifest prior to signing the manifest. 12. The generator shall ensure before the waste is transported offsite that the required information on all parts of the manifest are capable of being read.

B. Copy 4 of the manifest is retained by the Generator upon shipment of the infectious waste. Please mail this copy to the Purchasing Agent in Facilities Services. C. Copy 1 is mailed to the Generator by the owner/operator of the processing or disposal facility. Currently, the College s vendor, Stericycle, provides this copy via the company s website, www.stericycle.com. The Environmental Health & Safety Coordinator ensures this copy is available within the required 20 day period. D. Copy 1 must be received by the Generator within 20 days of the date the generator s waste was accepted by the initial transporter. If the manifest is not received, a. Generator must contact the transporter or owner or operator of the designated facility or both to determine the status of the infectious waste. b. Notify the regional PADEP office by telephone within 1 business day of the status of the shipment. c. If the manifest is not received within 35 days of the date, the generator must notify by telephone the regional PADEP office and submit an exception report to the PADEP s central office that includes 1. a legible copy of the unsigned manifest 2. cover letter explaining the efforts undertaken to located the waste shipment and the results E. All manifests must be maintained for 5 years from the date of shipment.

Appendix A Infectious Waste Checklist Requirement Storage: - Containers maintained, not leaking, puncture proof. - Waste maintained in nonputrescent state - no odors. - Sharps stored in appropriate containers. - Double bags employed when bags are the only storage container. Bags meet strength and certification requirements. - Infectious waste stored for no longer than 30 days at room temperature. - Infectious waste stored for no longer than 90 days in the freezer. - Infectious waste sharps stored for no longer than 1 year. Labeling: - Outermost container of infectious waste for offsite transport labeled immediately with proper label name, address and telephone of generator, and date waste generated in indelible ink - Outermost container of infectious waste properly labeled with biohazard symbol and the words infectious waste. - Stationary containers lined with appropriately colored bag. Containers: - Nonrigid containers not re-used. - Corrugated fiberboard containers only re-used if container protected from direct contact of the waste. Manifests: - Name, address and telephone number of college printed on manifest. - Total number of pages used to complete manifest. - Transporter(s) company name, identification number, PA infectious and chemotherapeutic waste transporter license number and telephone number on manifest. - Number and type of containers and the total quantity of waste by weight of volume listed. - Infectious waste code for each waste. - Proper DOT shipping name, hazard class and identification number if applicable. - Special instructions for handling, storage and disposal if applicable. - Printed/typed name and handwritten signature of generator s authorized signature. - Printed/typed name and handwritten signature of the initial transporter s authorized representative and date of receipt. Completed