Mouse Testosterone ELISA



Similar documents
Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

Mouse krebs von den lungen 6 (KL-6) ELISA

Human Free Testosterone(F-TESTO) ELISA Kit

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Malondialdehyde (MDA) ELISA

Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit

Rat Creatine Kinase MB Isoenzyme (CKMB) ELISA

Bovine Vitamin B12 (VB12) ELISA Kit

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Mouse glycated hemoglobin A1c(GHbA1c) ELISA Kit

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Mouse Keyhole Limpet Hemocyanin antibody(igm) ELISA Kit

The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of PST in mouse tissue homogenates and other biological fluids.

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Reagents Quantity Reagents Quantity. Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4. Standard 2 Standard Diluent 1 20mL

Uscn Life Science Inc. Wuhan

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

Rat Fibronectin ELISA Kit

IgE (Human) ELISA Kit

Mouse glycated hemoglobin A1c (GHbA1c) ELISA Kit

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

ab Albumin Human ELISA Kit

Cancer Antigen CA125 Human ELISA Kit

Human Parathyroid Hormone (PTH) ELISA Kit

Dengue IgM ELISA. For the quantitative determination of IgM-class antibodies to Dengue Virus in serum.

ab Complement C1q Human ELISA Kit

Epinephrine/Norepinephrine ELISA Kit

For the development of sandwich ELISAs to measure phosphorylated Epidermal Growth Factor Receptor (EGF R) in cell lysates.

IP10 Human ELISA Kit

Human IP-10 ELISA Kit, pink-one

ELISA-VIDITEST-MICROCYSTIN LR Lot: XX

Human TNF- Product #

RayBio Human IL-8 ELISA Kit

TECHNICAL BULLETIN. Angiotensin II EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0010 Storage Temperature 20 C

TECHNICAL BULLETIN. Glucagon EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0202 Storage Temperature 20 C

Revised 3 Oct rm (Vers. 16.1)

IP-10 ELISA KIT INTENDED USE

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

TRIIODOTHYRONINE (T3) ELISA Kit Protocol

RayBio Human TNF-alpha

Human IGFBP-3 ELISA Kit (higfbp-3-elisa)

QuickZyme Soluble Collagen Assay

Albumin ELISA Kit. Albumin ELISA Kit. Zur in vitro Bestimmung des Albumin in Urin und Stuhl

Mix-N-Go Protein A Assays

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

Toxoplasma gondii IgM ELISA Kit Protocol

Measles (Rubeola) IgM ELISA Catalog No. CB (96 Tests)

ab Free Testosterone ELISA Kit

How Does a Doctor Test for AIDS?

CatCombi Research ELISA Kit

QuickTiter Hepatitis B Surface Antigen (HBsAg) ELISA Kit

Irisin, Recombinant (Human, Mouse, Rat, Canine) Enzyme-linked Immunosorbent Assay Protocol

> IGF-1 (human) Table of Contents. Catalog # Well Enzyme Immunoassay Kit For use with human serum and plasma

QuickTiter FeLV Core Antigen ELISA Kit (FeLV p27)

LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

TECHNICAL BULLETIN. Cholecystokinin (CCK) EIA Kit for serum, plasma, culture supernatant, and cell lysates

竞 争 性 分 析 Epitope Mapping 实 验 方 法

CA19-9. Enzyme immunoassay for the quantitative determination of CA19-9 in human serum or plasma Only for in-vitro diagnostic use

ab Protein Sumoylation Assay Ultra Kit

Protocol for Catalog # EK Angiotensin II (Human, Rat, Mouse, Canine) EIA Kit (range: 0-25 ng/ml)

Free Testosterone Cat# 2924Z

Rat Anti-KLH Rat IgM ELISA Kit

TECHNICAL BULLETIN. Brain Natriuretic Peptide EIA Kit for serum, plasma, culture supernatant, and cell lysates

Mouse GLP-2 ELISA. For quantitative determination of mouse GLP-2 in serum or plasma samples.

Quantikine ELISA. Human/Canine/Porcine Insulin Immunoassay. Catalog Number DINS00

mouse CXCL10/IP-10 ELISA

Tick-Borne Encephalitis (TBE/FSME) Virus IgG Human ELISA Kit

ab Triiodothyronine (T3) ELISA Kit

Dehydroepiandrosterone Sulfate ELISA (DHEA-S)

ab IP-10 (CXCL10) Human SimpleStep ELISA Kit

Mercodia C-peptide ELISA

Biomedical Technologies Inc.

Protein A Assay. Immunoenzymetric Assay for the Measurement of Protein A Catalog # F400. Intended Use. Summary and Explanation

ab83369 Alkaline Phosphatase Assay kit (Colorimetric)

Instruction Manual ELISA kit

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences

Mercodia C-peptide ELISA

Mouse-IgG Rheumatoid Factor ELISA Kit

Testosterone (Pig) ELISA Kit

Anti-CENP-B (IgG) ELISA

Enzyme Immunoassay for the Quantitative Determination of Histamine in Food. Histamine. Cat #COR

Anti-ds-DNA-A ELISA. For the quantitative and qualitative determination of IgA antibodies against double-stranded DNA (dsdna) in human serum

ab Anti- Borrelia burgdorferi IgM Human ELISA Kit

Cortisol (Saliva) ELISA

Borrelia burgdorferi IgM Human ELISA Kit

Ovarian Cancer Antigen CA125 ELISA Kit Protocol. (Cat. No.:EK )

ab Anti-Borrelia burgdorferi IgG Dog ELISA Kit

Qualification Study CHO 360-HCP ELISA (Type A to D)

Factors Affecting Enzyme Activity

Testosterone EIA Kit User Manual

Thrombin Generation Assay

MTT Cell Proliferation Assay

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: Genscreen ULTRA HIV Ag-Ab Number: PQDx Abstract

Serum Testosterone ELISA

HUMAN FREE THYROXINE (FT4) ELISA. Product Data Sheet. Cat. No.: RCAN-FT4-4340R. For Research Use Only. Page 1 of 16 VERSION

Human Luteinizing Hormone (LH) Custom Kit

THE ACTIVITY OF LACTASE

Transcription:

KAMIYA BIOMEDICAL COMPANY Mouse Testosterone ELISA For the quantitative determination of mouse Testosterone in biological samples. Cat. No. KT-52637 For Research Use Only. Not for use in diagnostic procedures. Page 1 of 5 Rev. 2010-02-17

Product Information Mouse Testosterone ELISA Cat. No. KT-52637 INTENDED USE This Testosterone ELISA kit is intended for laboratory research use only and is not for use in diagnostic or therapeutic procedures. The stop solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of Testosterone in the sample, this Testosterone ELISA kit includes a set of calibrators. The calibrators are assayed at the same time as the samples and allow the operator to produce a calibration curve of optical density versus Testosterone concentration. The concentration of Testosterone in the samples is then determined by comparing the O.D. of the samples to the calibration curve. PRINCIPLE This Testosterone enzyme linked immunosorbent assay applies a technique called a quantitative sandwich immunoassay. The microtiter plate provided in this kit has been pre-coated with a monoclonal antibody specific for Testosterone. Calibrators or samples are then added to the microtiter plate wells and Testosterone if present will bind to the antibody pre-coated wells. In order to quantitatively determine the amount of Testosterone present in the sample, a standardized preparation of horseradish peroxidase (HRP)-conjugated polyclonal antibody, specific for Testosterone are added to each well to sandwich the Testosterone immobilized on the plate. The microtiter plate undergoes incubation, and then the wells are thoroughly washed to remove all unbound components. Next, A and B substrate solution is added to each well. The enzyme (HRP) and substrate are allowed to react over a short incubation period. Only those wells that contain Testosterone and enzyme-conjugate antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. COMPONENTS Reagents Microtiter Plate Calibrator 1 (0 ng/ml) 1 Calibrator 2 (0.5 ng/ml) 1 Calibrator 3 (1 ng/ml) 1 Calibrator 4 (2.5 ng/ml) 1 Calibrator 5 (5 ng/ml) 1 Calibrator 6 (10 ng/ml) 1 Enzyme Conjugate Substrate A Substrate B Stop Solution Wash Buffer (100X concentrate) Lysis Buffer Quantity 96 wells 1 x 10 ml 1 x 10 ml Page 2 of 5 Rev. 2010-02-17

Note: The lysis buffer solution is used only when the sample is cell culture fluid & body fluid & tissue homogenate; If the sample is serum or blood plasma, then the lysis buffer solution is a superfluous reagent. STORAGE All reagents provided are stored at 4 C. Refer to the expiration date on the label. SAMPLE COLLECTION AND STORAGE Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at approximately 1,000 x g. Remove serum and assay immediately or aliquot and store samples at -20 C or -80 C. Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1,000 x g at 4 C within 30 minutes of collection. Store samples at -20 C or -80 C. Avoid repeated freeze-thaw cycles. Cell Culture Supernates and Other Biological Fluids Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20 C or -80 C. Avoid repeated freeze-thaw cycles. NOTE: Serum, plasma and cell culture fluid samples to be used within 7 days may be stored at 4 C, otherwise samples must be stored at -20 C ( 2 months) or -80 C ( 6 months) to avoid loss of bioactivity and contamination. Avoid freeze-thaw cycles. When performing the assay slowly bring samples to room temperature. DO NOT USE HEAT-TREATED SPECIMENS. MATERIALS REQUIRED BUT NOT SUPPLIED 1. Microplate reader capable of measuring absorbance at 450 nm. 2. Precision pipettes to deliver 2 ml to 1 ml volumes. 3. Adjustable 10-100 ml pipettes for reagent preparation. 4. 100 ml and 1 liter graduated cylinders. 5. Calibrated adjustable precision pipettes, preferably with disposable plastic tips. (A manifold multichannel pipette is desirable for large assays.) 6. 37 C incubator. 7. Absorbent paper. 8. Distilled or de-ionized water 9. Data analysis and graphing software. Graph paper: linear (Cartesian), log-log or semi-log, or log-logit as desired. 10. Tubes to prepare calibrator or sample dilutions. Precautions 1. Kamiya Biomedical l Company is only responsible for the kit itself, but not for the samples consumed during the assay. The user should calculate the possible amount of the samples used in the whole test. Please reserve sufficient samples in advance. 2. Please predict the concentration before assaying. If values for these samples are not within the range of the calibration curve, users must determine the optimal sample dilutions for their particular experiments. 3. If the samples are not indicated in the manual, a preliminary experiment to determine the validity of the kit is necessary. 4. Owing to the possibility of mismatching between antigen from other resource and antibody used in our kits (e.g. antibody targets conformational isotope rather than linear isotope), some native or recombinant proteins from other manufacturers may not be recognized by our products. 5. Influenced by the factors including cell viability, cell number and also sampling time, samples from cell culture supernatant may not be detected by the kit. Page 3 of 5 Rev. 2010-02-17

6. Fresh samples without long term storage is recommended for the test. Otherwise, protein degradation and denaturalization may occur in those samples and finally lead to wrong results. REAGENT PREPARATION Bring all kit components and samples to room temperature (18-25 C) before use. Dispense 10 µl of lysis buffer solution into 100 µl specimens, mix and stand for one hour (The proportion of lysis buffer and specimens shall be no less than 1:10). (NOTE: This step is required when the sample is cell culture fluid & body fluid & tissue homogenate; If the sample is serum or blood plasma, then this step should be skipped.) Wash Solution Dilute 10 ml of Wash Solution concentrate (100X) with 990 ml of de-ionized or distilled water to prepare 1,000 ml of Wash Solution (1X). ASSAY PROCEDURE It is recommended that all Calibrators and Samples be added in duplicate to the Microtiter Plate. 1. Secure the desired number of coated wells in the holder, then add 50 µl of Calibrators or Samples to the appropriate well of the antibody pre-coated Microtiter Plate. 2. Add 100 µl of Conjugate to each well. Mix well. Complete mixing in this step is important. Cover and incubate for 1 hour at 37 C. 3. Wash the microtiter plate using one of the specified methods indicated below: 4. Manual Washing: Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well completely with wash solution, then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure four more times for a total of five washes. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame. 5. Automated Washing: Aspirate all wells, then wash plate five times using wash solution. Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350 µl/well/wash (range: 350-400 µl). After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. It is recommended that the washer be set for a soaking time of 10 seconds or shaking time of 5 seconds between washes. 6. Add 50 µl substrate A and 50 µl substrate B to each well. Cover and incubate for 10 minutes at 20-25 C. (Avoid exposure to light.) 7. Add 50 µl stop solution to each well. Mix well. 8. Read the optical density (OD) at 450 nm using a microtiter plate reader immediately. CALCULATION OF RESULTS 1. This calibration curve is used to determine the amount in an unknown sample. The calibration curve is generated by plotting the average OD (450 nm) obtained for each of the six calibrator concentrations on the vertical (Y) axis versus the corresponding concentration on the horizontal (X) axis. 2. First, calculate the mean OD value for each calibrator and sample. All OD values are subtracted by the mean value of the zero calibrator before result interpretation. Construct the calibration curve using graph paper or statistical software. 3. To determine the amount in each sample, first locate the OD value on the Y-axis and extend a horizontal line to the calibration curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration. 4. Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in the result. Each user should obtain their own calibration curve. 5. The sensitivity by this assay is 0.01 ng/ml. Disposal Note Safety 1. This kit contains materials with small quantities of sodium azide. Sodium azide reacts with lead and copper plumbing to form explosive metal azides. Upon disposal, flush drains with a large volume of water to prevent azide accumulation. Avoid ingestion and contact with eyes, skin, and mucous Page 4 of 5 Rev. 2010-02-17

membranes. In case of contact, rinse affected area with plenty of water. Observe all federal, state, and local regulations for disposal. 2. All blood components and biological materials should be handled as potentially hazardous. Follow universal precautions as established by the Centers for Disease Control and Prevention and by the Occupational Safety and Health Administration when handling and disposing of infectious agents. IMPORTANT NOTES 1. When not in use, kit components should be refrigerated. All reagents should be warmed to room temperature before use. 2. Microtiter plates should be allowed to come to room temperature before opening the foil bags. Once the desired number of strips has been removed, immediately reseal the bag and store at 4 C to maintain plate integrity. 3. Samples should be collected in pyrogen/endotoxin-free tubes. 4. Samples should be frozen if not analyzed shortly after collection. Avoid multiple freeze-thaw cycles of frozen samples. Thaw completely and mix well prior to analysis. 5. When possible, avoid use of badly hemolyzed or lipemic sera. If large amounts of particulate matter are present, centrifuge or filter prior to analysis. 6. It is recommended that all calibrators, controls, and samples be run in duplicate. 7. When pipetting reagents, maintain a consistent order of addition from well-to-well. This ensures equal incubation time for all wells. 8. Cover or cap all reagents when not in use. 9. Do not mix or interchange different reagent lots from various kit lots. 10. Do not use reagents after the kit expiration date. 11. Read absorbances within 2 hours of assay completion. 12. All residual wash liquid must be drained from the wells by efficient aspiration or by decantation followed by tapping the plate forcefully on absorbent paper. Never insert absorbent paper directly into wells. 13. Because stabilized Chromogen is light sensitive, avoid prolonged exposure to light. Also avoid contact between stabilized Chromogen and metal, or color may develop. 14. Incomplete washing will adversely affect the test outcome. All washing must be performed with wash buffer provided. 15. Washing can be performed manually as follows: completely aspirate the liquid from all wells by gently lowering an aspiration tip (aspiration device) into the bottom of each well. Take care not to scratch the inside of the well. 16. After aspiration, fill the wells with at least 0.35 ml of diluted wash solution. Let soak for 10-15 seconds, then aspirate the liquid. Repeat as directed under Assay Procedure. After the washing procedure, the plate is inverted and tapped dry on absorbent tissue. 17. Alternatively, the wash solution may be put into a squirt bottle. If a squirt bottle is used, flood the plate with wash buffer, completely filling all wells. After the washing procedure, the plate is inverted and tapped dry on absorbent tissue. 18. If using an automated washer, the operating instructions for washing equipment should be carefully followed. 19. Assay Procedure Preliminary notes: Do not mix reagents from different lots. It is recommended that assays be performed in duplicate. Calibrators and samples must be assayed at the same time. Avoid exposing the substrate to direct sunlight. FOR RESEARCH USE ONLY. Not for use in diagnostic procedures. KAMIYA BIOMEDICAL COMPANY 12779 Gateway Drive, Seattle, WA 98168 Tel: (206) 575-8068 Fax: (206) 575-8094 Email: LifeScience@k-assay.com www.k-assay.com Page 5 of 5 Rev. 2010-02-17