HPS TM Products Series 43. Vacuum Line Heaters OPERATION AND MAINTENANCE MANUAL



Similar documents
For more information or literature, contact: MKS Instruments, Inc Sterling Drive Boulder, CO USA

ATS Overhead Table Shelf System INSTRUCTION MANUAL

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

APC Step-Down Transformer. User s Manual

Electric Water Heater

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Installation and safety instructions for AC/DC built-in devices

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Model 1756 Test Lead Kit

Ceiling Mount Air Handler Manual

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

VK-250 WARRANTY REGISTRATION FORM

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Installation and Operating Instructions (for chargers shown below)

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Mini-led spotlight with magnetic base

HP UPS R1500 Generation 3

DRY-BATH INCUBATOR. MODELS I-G35, I-G55, I-120 and I-240. Owner/Operator Manual

MODEL G300 BRAKE BLEEDER

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

4 in 1 Air Compressor

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Single Phase Soft Starter


12-Volt 10-Amp Regulated Power Supply

Threaded Inline Air Heaters

100 Series Maxi Internal Filters. Instruction Manual

Advantium 2 Plus Alarm

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

BroadBand PowerShield. User Manual

Installation and Operating Instructions (for chargers shown below)

RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack

For Models #6-5001, #6-7501, # & #10-12K1

Tablet 30W Tablet 92W

Utility Distribution Systems

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

CHARGING SYSTEMS INTERNATIONAL

Scotch-Weld PUR Easy 250 Adhesive Applicator

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Manual Ranging MultiMeter

Bubble King. User Manual

Nest Learning Thermostat Installation Guide. Installation step-by-step

SMD Rework Station TABLE OF CONTENTS

3 WATT LED SPOTLIGHT Model No. SLM

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

tire inflator with pressure gauge

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

SENTRY SECURITY MODULE

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

Architect/Contractor Information Package

Wine Cooler with Thermo-Electric Cooling & Heating Technology

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

, User s Manual

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

About this Manual. Support for Your Product

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

USER S MANUAL HSC-24A

i410/i1010 AC/DC Current Clamp

Air Conditioning Systems Warranty Manual. Version 1.8

INSTRUCTION MANUAL MODEL PCD-88

Mini Power Bank and Charger

Oil and Coolant Circulating Heating System. Model - OCSM

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Machine Safety Switch: SI-LM40 Series Limit Switch Style

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

24.2L M.A.N. V12 Engine Module

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Ensuring safety and uptime by managing condensable gases

How To Use A Power Supply Unit (Upu)

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Anthro Tablet Charging Cabinets

Triple Expansion Chassis

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

16/32 Channel 1U Rack Mount CCTV Power Supply

120Volt 60-70A ARC WELDER Rev

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Transcription:

HPS TM Products Series 43 Vacuum Line Heaters OPERATION AND MAINTENANCE MANUAL

Please Note: MKS Instruments provides these documents as the latest version for the revision indicated. The material is subject to change without notice, and should be verified if used in a critical application.

HPS TM Products Series 43 Vacuum Line Heaters March 1997 PART #100009447 REV. A Vacuum Line Heater

Part # 43 - or 93 - Please fill in these numbers and have them readily available when calling for service or additional information. (The part number is located on the label attached to a cable of the heater.) For more information or literature, contact: MKS Instruments, Inc., HPS TM Products Inc. 5330 Sterling Drive Boulder, CO 80301 USA Phone: 303-449-9861 800-345-1967 FAX: 303-442-6880 1999 MKS Instruments, Inc., HPS TM Products Inc. All rights reserved. Kevlar and Teflon are registered trademarks of E.I. du Pont de Nemours & Co. Twist-Lock is a registered trademark of Hubbell, Inc. VacuComp is a trademark of MKS Instruments, Inc., HPS TM Products Vacuum Line Heater

Table of Contents Table of Contents Package Contents... 1 Symbols Used in this Manual... 1 Safety Precautions... 2 Specifications... 3 Feature and Control Locations... 4 Typical Applications for theseries 43 Vacuum line Heaters... 5 About the HPS TM Products Series 43 Vacuum Line Heaters... 6 Installing and Using the Series 43 Vacuum Line Heaters... 7 Before Installing Heaters... 7 Power... 7 Power Cord... 7 Inspect Pipe System and Heaters... 7 Installing the Heaters... 8 Temperature Control Circuit... 8 Using the Heaters... 9 Replacing a Blown Fuse in the Power Cord (without GFELCI)... 9 Accessories / Part Replacement... 11 Product Warranty... 12 Notes... 13 Vacuum Line Heater

Vacuum Line Heater

Package Contents Before unpacking your HPS Products Series 43 Vacuum Line Heater, check all surfaces of the packing material for shipping damage. Please be sure that your Series 43 Heater package contains these items: t Series 43 Heaters (quantity specified on packing slip) t 1 VacuComp Series 43 Vacuum Line Heaters User's Guide. Power cords are not included with the Heaters and must be ordered separately. See page 13 for a list of these and other accessories. Inspect the Heater for visible evidence of damage during shipment. If it has been damaged, notify the carrier immediately. Keep all shipping materials and packaging for claim verification. Do not return the product to HPS TM. ( If any items are missing from the package, call HPS Customer Service at 1-303-449-9861 or 1-800-345-1967. Inspect the for visible evidence of damage. If it has been damaged in shipping, notify the carrier immediately. Keep all shipping materials and packaging for claim verification. Do NOT return the Product to HPS TM. Symbols Used in this Manual The first three symbols below, that may be located on your Series 43, identify critical safety concerns. They are used throughout this manual to further define the safety concerns associated with the product. The last two symbols identify other information in this manual that is essential or useful in achieving optimal performance from the Series 43. CAUTION: Risk of electrical shock. ISO 3864,No. B,3.6 CAUTION: Refer to manual. ISO 3864,No.B,3.1 Failure to heed message could result in personal injury or serious damage to the equipment or both. CAUTION: Hot surface. IEC 417,No.5041 Failure to heed message could result in severe burns. Failure to heed message could result in damage to the equipment. Calls attention to important procedures, practices, or conditions. Vacuum Line Heater 1

Safety Precautions Do not use Heaters outdoors or in an explosive environment. The Heaters are rated IP40 according to IEC 529 "Degrees of Protection Provided by Enclosures," (IP Code). IP40 is, "Protected against ingress of solid foreign objects greater than or equal to 1.0 mm in diameter and not protected against ingress of water with harmful effects." Heaters are designed for use with metal piping. Heater operating temperatures may exceed the melting point of other materials. Check specifications. Do not immerse the Heaters in water or liquid of any kind. Electrical shock may result. Permanent Heater damage may also occur. Ground piping system according to U.S. National Electric Code or local requirements or both. If Heaters are used or operated on ungrounded metal piping, a risk of electrical shock is posed. Alternatively, a Ground Fault Equipment Leakage Current Interrupter (GFELCI) may be used. Do not touch the Heater surface during operation. Outside surface temperatures may reach 135 C. Severe burns are likely. Heaters must be secured to piping before operation. Heaters may overheat, resulting in permanent damage, if not attached to piping. Also, Heaters should only be used with piping of their assigned diameter. 22 Vacuum Line Heater

Specifications Environment Indoor use only Temperature Heater Nominal Set Point Heater Exterior Range Pipe Line Interior Range Relative Humidity Electrical Duty Cycle Power Cord Current Limit 150 C (302 F) 105 C (221 F) 90 to 135 C 55 to 100 C (194 to 275 F) (131 to 212 F) 120 to 200 C 85 to 140 C (248 to 392 F) (185 to 284 F) 90% maximum ~50% for 120 VAC, ~72% for 100 VAC 12 A Materials Foam Thickness Connectors Weight Range Product Safety Silicone, fiberglass-reinforced silicone, Kevlar, Teflon, insulated wire 1 /8 or 1 /4 (3.2 or 6.4 mm) Midget Twist-Lock, nylon, NEMA ML-1 0.3 to 2.3 lb (0.14 to 1.03 kg) UL Recognized File E52951 2JR Design and / or specifications subject to change without notice. Vacuum Line Heater 3

Feature and Control Locations ➊ ➋ ➌ ➍ ➎ ➏ Exterior Heater Surface Interior Heater Mat Control Block with a Ceramic-Bodied, Snap-Action Thermostat and a Thermal Fuse Cable Lead with Male Twist-Lock Connector Cable Lead with Female Twist-Lock Connector Kevlar Lace ➊ ➍ ➎ ➌ ➏ ➋ Straight-Section Heater ➐ ➑ ➓ ➐ ➑ ➒ ➓ 120 VAC, Fused Power Plug Spare Fuse Ground Ring Terminal Female Twist-Lock Connector ➒ 120 VAC Power Cord 6 ft or Custom Length, without GFELCI 44 Vacuum Line Heater

Typical Applications for the Series 43 Vacuum line Heaters vv Prevent solidification of ammonium chloride (NH 4 Cl) in a silicon nitride LPCVD system vv Prevent solidification of aluminum chloride (AlCl 3 ) in an aluminum etching system vv Reduce solid buildup in other semiconductor processes, such as titanium nitride, tungsten, and TEOS CVD Vacuum Line Heater 5

About the HPS TM Products Series 43 Vacuum Line Heaters The HPS TM Products Series 43 Vacuum Line Heaters, a line of heating jackets specially made for HPS TM components and valves, have been designed for semiconductor processes to prevent solid buildup in vacuum systems. The Series 43 Heaters are designed to be simple and quick to install. These Heaters reduce contamination, increase your system uptime and product yield, and decrease scheduled maintenance. To control the solidification of by-products, such as ammonium chloride, you need to maintain a system vacuum component temperature of at least 120 C. The Series 43 Heaters heat your system to a stable temperature well above this minimum, drastically reducing by-product buildup and system downtime. The Series heats lines internally to an average, stable temperature of 150 C (for the 150 C set point thermostat) or 105 C (for the 105 C set point thermostat). From room temperature, the Heaters typically reach their set temperature in less than 30 minutes. The Heater s lace and hook feature makes it quick and easy to install or remove Series 43 Heaters. All materials used in the Heaters and Insulators are suitable for clean room use. As a safety feature, a thermal fuse is included, which prevents any possible overheating in the unlikely event of thermostat failure. 66 Vacuum Line Heater

Installing and Using the Series 43 Vacuum Line Heaters Before Installing Heaters Power Assigned to each individual Heater is a current rating. Do not link Heaters together in excess of 12 A as this may damage the Heaters permanently. Verify load with the following steps. 1 Locate the current rating for 120 VAC on the label attached to a cable lead. 2 Add the values together to get a total demand of 12 A or less. The power and current ratings are different if using a 100 VAC outlet. Add the values shown on the label for 100 VAC. Also note that the electrical duty cycle is higher at 100 VAC, meaning Heaters will take longer to reach a stable temperature. Power Cord Using a Ground Fault Equipment Leakage Current Interrupter (GFELCI) is highly recommended. Circuit interruption can be supplied either by your electrical service box or by the HPS TM GFELCI power cord (see Accessories, p. 13). The cord provides a resettable, 12-ampere circuit breaker. An HPS TM Heater power cord and a separate, portable GFCI are also available (see Accessories, p. 13). The power cord has an integrated, replaceable 12-ampere fuse for safety. Either power cord has a grounded ring terminal for attachment to either ISO-KF or ISO-MF vacuum flange clamps. Place the ring terminal under the wing nut of a standard ISO-KF clamp to ground its flange. A special ISO- Universal Grounding Claw Clamp is available to ground MF 80 or MF 100 clamps to their flange (see Accessories, p. 13). Inspect Pipe System and Heaters 1 Inspect the surfaces of piping for burrs that might penetrate the Heater insulation and for surface defects that may not allow full contact of the Heater or Insulator with the pipe. 2 Inspect each Heater for damage, particularly on the ends and the inside surface. Do not use a damaged Heater. 3 Contact the HPS TM Customer Service Department if any damage is found. Vacuum Line Heater 7

Installing the Heaters Do not use Heaters outdoors or in an explosive environment. 1 At the point of power supply for the Heaters, begin to install them one at a time. Tie the laces snugly or fasten in place with their snaps. Series 43 Heaters are designed to fit snugly for good heat transfer but should tie in place easily. Do not use any other device to hold a Heater in place. Heaters for bellows and flexible hose must be installed with the control block (cord strain relief) in the up position with respect to gravity. Failure to follow these instructions could lead to overheating and possible Heater damage. 2 Connect all subsequent cable Twist-Lock connectors. Arrange and connect Heater cable leads in a manner least likely to place stress on the Heater mounting system or to impair the view of critical readouts. Cables should not touch surfaces that might damage the wire insulation. The last Heater of each line will have an unused cable with a female connector. It is safe to leave this connector alone. A cap is not required. 3 Retrace Heater installation to be sure that all connectors are interlocked and all laces are tied snugly. Ground piping system according to U.S. National Electric Code (NEC) or local requirements or both. Temperature Control Circuit For specially ordered Heaters that need external temperature control, continue on with the next step. For standard catalog Heaters with internal mechanical thermostats, skip this section. Go to Using the Heaters. 1 Turn off power to the controller if it has been turned on. 2 Connect any thermocouple circuit to its respective temperature controller. 3 Verify power supply from the controller to the Heater. It must be properly fused per manufacturer s specification, local code, and NEC requirements. 88 Vacuum Line Heater

4 Connect the power supply and ground leads from the temperature controller to the initial Heater. 5 Adjust the temperature control to the desired setting. Do not exceed 180 C. A higher temperature setting may shorten Heater life. Using the Heaters Heaters must be secured to piping before operation. Upon startup, observe Heaters closely for smoke, which indicates overheating of piping or an individual Heater. 1 If smoke is seen, shut down the system. 2 Verify that operating temperatures are under 180 C before restarting. 3 Check the Heaters' rated voltage. It must be consistent with the supply voltage. Do not touch the Heater surface during operation. Outside surface temperatures may reach 135 C. Severe burns are possible. Replacing a Blown Fuse in the Power Cord (without GFELCI) The power cords' integrated 12-ampere fuse is located inside the 120 VAC plug. The fuse may blow if Heaters are strung together in excess of 12 A. A shorted Heater would also blow a fuse. Observe or test the Heater and check power consumption before replacing. 1 With a screwdriver, remove the rubber insulator sheet at the base of the electrical prongs of the plug as shown on the next page. A pry slot has been provided to ease removal. 2 A spare fuse is encapsulated in the power cord near the plug. Use a knife to gently pry it out. 3 Insert the new fuse into the plug of the cord and replace rubber insulator sheet. If another fuse is needed, replace with a fuse rated for 12 A and 100 to 250 V. Spare fuses may also be purchased from HPS TM (see Accessories, p. 11). Vacuum Line Heater 9

Spare fuse 12-A fuse Inside 120 VAC Power Cord 6 ft or Custom Length, without GFELCI 10 10 Vacuum Line Heater

Accessories / Part Replacement Fuses 12 A, Box of 5 Part # 100006985 Ground Fault Circuit Interrupter (GFCI) Grounding Claw Clamp MF 80 or MF 100 Low Temperature Alert (LTA) Jumper Kit LTA Lead Kit Power Cord, 120 VAC 6 ft Custom, 25 ft Max 6 ft, With GFELCI (and 12-Ampere Circuit Breaker), 43PWRACC001 100007322 100008683 100008680 43PWRCORD01 43PWRCORD02 43PWRCORD04 Please call HPS TM Products Customer Service Department at either 1-303- 449-9861 or 1-800-345-1967 to order any of these parts or to receive catalogs for other HPS TM Products. Vacuum Line Heater 11

Product Warranty Extent of the Warranty MKS Instruments, Inc., warrants the HPS TM Products Series 43 Vacuum Line and its accessories to be free from defects in materials and workmanship for one (1) year from the date of shipment by HPS TM or authorized representative to the original purchaser (PURCHASER). Any product or parts of the product repaired or replaced by HPS TM under this warranty are warranted only for the remaining unexpired part of its one (1) year original warranty period. After expiration of the applicable warranty period, the PURCHASER shall be charged HPS TM current prices for parts and labor, plus any transportation for any repairs or replacement. ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO THE WARRANTY PERIOD. NO WARRANTIES, EXPRESS OR IMPLIED, WILL APPLY AFTER THIS PERIOD. Warranty Service The obligations of HPS TM under this warranty shall be at its option: (1) to repair, replace, or adjust the product so that it meets applicable product specifications published by HPS TM or (2) to refund the purchase price. What Is Not Covered The product is subject to above terms only if located in the country of the seller from whom the product was purchased. The above warranties do not apply to: I. Damages or malfunctions due to failure to provide reasonable and necessary maintenance in accordance with HPS TM operating instructions. II. Damages or malfunctions due to chemical or electrolytic influences or use of the product in working environments outside the specification. III. Fuses and all expendable items which by their nature or limited lifetime may not function for a year. If such items fail to give reasonable service for a reasonable period of time within the warranty period of the product; they will, at the option of HPS TM, be repaired or replaced. IV. Defects or damages caused by modifications and repairs effected by the original PURCHASER or third parties not authorized in the manual. Condition of Returned Products HPS TM will not accept for repair, replacement, or credit any product which is asserted to be defective by the PURCHASER, or any product for which paid or unpaid service is desired, if the product is contaminated with potentially corrosive, reactive, harmful, or radioactive materials, gases, or chemicals. When products are used with toxic chemicals, or in an atmosphere that is dangerous to the health of humans, or is environmentally unsafe, it is the responsibility of the PURCHASER to have the product cleaned by an independent agency skilled and approved in the handling and cleaning of contaminated materials before the product will be accepted by HPS TM for repair and/or replacement. In the course of implementing this policy, HPS TM Customer Service Personnel may inquire of the PURCHASER whether the product has been contaminated with or exposed to potentially corrosive, reactive, harmful, or radioactive materials, gases, or chemicals when the PURCHASER requests a return authorization. Notwithstanding such inquiries, it is the responsibility of the PURCHASER to ensure that no products are returned to HPS which have been contaminated in the aforementioned manner. Other Rights and Remedies I. These remedies are exclusive. HPS TM SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES, FOR ANTICIPATED OR LOST PROFITS, INCIDENTAL DAMAGES OR LOSS OF TIME, OR OTHER LOSSES INCURRED BY THE PURCHASER OR BY ANY THIRD PARTY IN CONNECTION WITH THE PRODUCT COVERED BY THIS WARRANTY, OR OTHERWISE. Some states do not allow exclusion or limitation of incidental or consequential damage or do not allow the limitation on how long an implied warranty lasts. If such laws apply, the limitations or exclusions expressed herein may not apply to PURCHASER. II. Unless otherwise explicitly agreed in writing, it is understood that these are the only written warranties given by HPS TM. Any statements made by any persons, including representatives of HPS TM, which are inconsistent or in conflict with the terms of the warranty shall not be binding on HPS TM unless reduced to writing and approved by an authorized officer of HPS TM. III. This warranty gives PURCHASER specific legal rights, and PURCHASER may also have other rights which vary from state to state. IV. For HPS TM products sold outside of the U.S., contact your MKS TM representative for warranty information and service. Warranty Performance To obtain warranty satisfaction, contact the following: MKS TM Instruments, Inc., HPS TM Products, Inc., 5330 Sterling Drive, Boulder, CO 80301, USA, at phone number (303) 449-9861. You may be required to present proof of original purchase. 12 12 Vacuum Line Heater

Notes Vacuum Line Heater 13

14 14 Vacuum Line Heater