TM200VP. Thermostatic Mixing Valve. Installation instruction. Keep instructions for later use! EB-TM200VP Rev. A



Similar documents
STABITHERM INSTALLATION & SERVICE BOOKLET

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Safe Touch TMV3 Thermostatic Shower ST10010CP

Coolflo Safe Touch Shower Mixing Valve ST20015CP

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Artisan Thermostatic Bath Shower Mixer

Thermostatic bar showers. Troubleshooting and maintenance

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Assembly and instructions

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

ALTO EV. Installation Instructions Thermostatic Bar Shower Valve

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Design Utility Lever Thermostatic Bath Shower Mixer

E-gas Instant Gas Water Heaters

Float and Thermostatic Traps Series H, C and X

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Chill 4 Hole Bath Shower Mixer

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

1 DESCRIPTION OF THE APPLIANCE

Shower Handbook (Also covers 650 chrome variant)

Control of legionella bacteria in water systems

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

AMX300 DirectConnect Mixing Valve Kits

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

SF15K SF05KSS, SF10KSS

Installation Instructions and User Guide

Element D Services Plumbing

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

Please also see 10 golden rules for correct Saniflo installation on

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Laddomat Charging unit

Oil and Coolant Circulating Heating System. Model - OCSM

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

SELECTION, APPLICATION AND MAINTENANCE

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Electric Instantaneous. Water Heaters. Service manual

Hydraulic control unit series

Installation, Maintenance, & Repair Series 4000B/LF4000B

SELECTION, APPLICATION & MAINTENANCE

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Elson 10/15L Unvented Water Heater

Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

Hot water supply, distribution and use

V10 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Operating instructions

BERMAD Fire Protection

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

PBX Series Quick Fit Connector Bimetallic Steam Traps

Operators manual Basic water heater

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Morco House Riverview Road Beverley HU17 0LD

Troubleshoot resources for homeowner

Liquorice Kitchen Sink Tap

Unvented water heater

AIRE Thermostatic bath shower mixer Installation and operating instructions

Blowdown vessels Meeting the requirements of HSE PM60

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Your safety and the safety of others are very important.

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

VAD Variable Area Desuperheaters

BERMAD Fire Protection

Thermo Siphon Solar Systems

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

How To Design A Gas Dryer

Description of functions

Operating instructions

1. Description. 2. List of Accessories included A B C F G H

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

your water pressure explained

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Unvented water heater

Itho Products for Hot and Boiling water. product-

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

MIRA'S GUIDE TO MIXER SHOWERS

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

FILLING AND PURGING THE SYSTEM

UNDERSTANDING CENTRAL HEATING SYSTEMS

Energy Saving Fact Sheet Boilers

2010 Residential Water Heater Replacement Check List

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

ClearView 100. Instruction Manual

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Mira Extra Bath and Thermostatic Shower Control

Elektromotoren und Gerätebau Barleben GmbH

Baxi Combi 80e & 105e

ENGINE COOLING SYSTEM

Transcription:

TM200VP Installation instruction EB-TM200VP Rev. A Keep instructions for later use! Thermostatic Mixing Valve

1. Safety Guidelines 1. Follow the installation instructions. 2. Use the appliance according to its intended use in good condition with due regard to safety and risk of danger. 3. Note that the appliance is exclusively for use in the applications detailed in these installation instructions. Any other use will not be considered to comply with requirements and would invalidate the warranty. 4. Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons. 5. Immediately rectify any malfunctions which may influence safety. 2. Application The Honeywell TM200VP TMV3 Approved thermostatic mixing valve has been specially designed to meet the NHS Model Engineering Specification D 08 to reduce the risk of emitting water at an unsafe temperature. Valves operating outside the conditions shown in the table below cannot be guaranteed to operate as TMV 3 valves. Table 1: Conditions for normal use Operating pressure range High Low pressure pressure Maximum static pressure [bar] 10 10 Flow pressure, hot & cold [bar] 1 to 5 0.2 to 1 Hot supply temperature [ C] 52-65 52-65 Cold supply temperature [ C] 5-20 5-20 Thermostatic mixing valves are required to meet specific performance criteria dependent on application. Table 2: Mixed water temperature Application Mixed water temperature (at point of discharge [ C]) B Bidet 38 max. S Shower 41 max. W Washbasin 41 max. T44 Bath (44 C fill) 44 max. Table 3: Suitable applications suitable for application on TM200VP 3/4E HP-W, LP-W, LP-B, HP-B, (15mm) LP-S, HP-S, HP-T44 TM200VP 3/4H HP-W, LP-W, LP-B, HP-B, (22mm) LP-S, HP-S, HP-T44 The TM200VP can be fitted to a single outlet or to several outlets, provided that both the water supply pressures and flow rates are adequate. To comply with health guidelines, a thermostatic mixing valve should be no further than two metres from any outlet it is supplying. Bath HOT Diagram 1 HOT HOT COLD HOT COLD MU1H-1363GE23 R0608 2 Honeywell GmbH

3. Specification Table 4: Specifications Maximum working pressure 10 bar Maximum hot inlet temperature 90 C Supply pressure to both Hot and Cold inlets should be within the following range, but not exceed the differential pressure stated below High pressure systems 0.5-5.0 bar Low pressure systems 0.1-1.0 bar Maximum differential pressure between Hot and Cold should not exceed the following High pressure systems 2.0 - bar Low pressure systems 0.4 - bar Mixed temperature setting range 35 C-46 C Minimum temperature between hot 10 C supply and mix to ensure safety shut-off requirement Valve body material Dezincification resistant chrome plated brass Materials = WRAS approved for use with wholesome water Approvals= Buildcert approved as meeting the NHS Model Engineering Specification D 08 - certificate number BC308/0108 4. Flow rate chart Pressure drop p (bar) 1,0 0,8 0,6 0,5 0,4 0,3 0,2 0,1 0,08 0,06 0,05 0,04 0,03 0,02 0,01 3 4 5 6 7 8 9 10 20 30 Through flow amount V (Vmin) 5. Safety shut-off feature The TM200VP will automatically close off the mixed water flow in the event of either hot or cold water supply failure when installed in accordance with these installation instructions. After safety shut-off shutdown has occurred, and the mixing valve has cooled down, very low flow may occur. This is normal and is not cause for alarm. 6. Installation 6.1 Safety guidelines for installation Jointing compound will cause damage to the internals of the mixing valve and prevent the check valves from functioning correctly. Therefore, jointing compound must not be used on the connections and could invalidate the warranty if used. Use of jointing compounds in other parts of the installation should be avoided or flushed out before fitting the TM200VP. It is preferable for the TM200VP to be installed with balanced dynamic pressure. However, control will also remain within the specified limits when upply pressures are different, provided that under flow conditions the pressure differential between the supplies remain within the stated specification. The installer must take precautions to ensure this. Failure to observe these instructions may lead to a potential failure or incorrect operation of the valve. It is strongly recommended that the pipework is flushed before installing the mixing valve. Grit, flux and other debris will adversely affect the performance of TM200VP. No claim for malfunction will be considered if adequate protection against dirt ingress is not provided. If there is any doubt then a strainer (e.g. Honeywell FY32) should be fitted upstream of the TM200VP and on both hot and cold supplies. Honeywell GmbH 3 MU1H-1363GE23 R0608

6.2 Installation Guidelines These instructions should be followed to ensure a trouble free installation. The installer should make sure that the installation complies with the requirements of the Water Regulations and any other relevant regulations. Before installing a TM200VP, check water flow rates, supply temperatures and dynamic pressures at all hot and cold taps. A calibrated jug or vessel of known volume and a watch with a second hand can be used for water flow measurements. Alternatively a water flow gauge can be used. Due account should be taken of multiple demand, for example, the simultaneous use of two or more taps to ensure adequate hot and cold flow rates to the mixing valve is maintained even when the outlets are turned on. When installing with unit with plastic pipe, an appropriate insert should be used according to the pipe manufacturer s recommendation. Sufficient consideration should be given to the support of the unit, particularly if installing with plastic pipe. Where necessary, it is recommended to use copper pipe on at least one leg (the valve outlet to the tap may be the most suitable). The TM200VP has been designed to slow down the build up of calcium within the valve body. However, in known hard water areas, the use of a water treatment device should be considered to promote trouble free operation of the controls and fittings. It is preferable for the TM200VP to be installed with balanced dynamic pressure. However, control will also remain within the specified limits when supply pressures are different provided that under flow conditions the pressure differential between supplies is within the stated specification. The TM200VP can be installed in any orientation including vertical or horizontal pipework. It is recommended that isolation/service valves are installed in the supply pipework adjacent to the TM200VP to facilitate servicing of the valve. The TM200VP is provided with 15mm or 22mm compression fitting and flanged connectors on all three ports. This enables the valve to be fitted to an existing system without straining the pipework and also assists with the servicing of the mixing valve. 6.3 Installation 1. The TM200VP should be connected in the hot water supply pipe with the flow in the direction of the arrows stamped on the body, + = HOT, = COLD and MIX to hot tap(s). 2. The integral check valves supplied within the tailpieces of thetm200vp must be fitted to the hot and cold inlet ports, as shown in diagram 2. This is to prevent cross circulation between hot and cold pipes and they should not be removed under any circumstances. Diagram 2 7. Setting the TM200VP The valve is set by turning the greencontrol knobclockwise to reduce the mixed water temperature and anticlockwise to increase the mixed temperature. The valve has a single turn through approximately 360, with a central control band from 35 C to 46 C. The hot tap should be left to stabilise before final setting to ensure correct adjustment. For convenience typical settings are marked on the green control knob. These settings will be accurate when dynamic hot and cold supply pressures are equal. They will vary slightly from the indicated figure when hot and cold supply pressures are different and should be used as a guide only. The mixed water temperature should be set at the temperature required for a particular application (See Table 2). MU1H-1363GE23 R0608 4 Honeywell GmbH

8. Locking the setting Once the correct setting has been achieved it can be locked in position by placing the clear cap over the control knob ensuring the notch in the clear cap and lug on the valve are engaged (see diagram 3). The cap is then secured in place with the screw provided. The actual set point temperature can be viewed through the clear window as shown on the locking cap in diagram 3. The TM200VP is now ready for use. Clear window Diagram 4 Cold water tank Cold water tank Diagram 3 Locking cap Lug Notch 9. A typical example The example shown in diagram 4 below shows a typical system with mains pressure cold feed and low pressure tank fed hot water installation. Under these conditions the hot and cold water is separate and therefore differences in fluctuations in hot and cold flow rates and pressures whilst being a nuisance are not that important. Once mixing valve(s) are fitted as shown in diagram 5 to give a blended hot water temperature, the hot and cold systems are connected and steps must be taken to ensure that the supply pressures are kept within the specified differential. In diagram 5 this has been achieved by fitting a pressure reducing valve (for example, a Honeywell D05 pressure reducing valve) on the common cold inlet. This not only gives improved performance from the mixing valves but also the system in general. In addition, pressure reducing valves help reduce the overall water consumption. 1. If a new water main is fitted, or work is carried out to the old water main then a strainer should be fitted immediately after the stop tap to prevent debris from entering the mixing valves. If work is carried out to an existing system please refer to the section on installation. If there is any doubt, then a strainer should be fitted. Pressure reducing valve Diagram 5 2. Because pressures vary due to head loss between upper and lower floors as well as pipework layout and sizing, fitting pressure reducing valves in higher pressure zones will reduce the flow from outlets in those areas minimising the risk of starving flow in other lower pressure zones. 3. The mixing valves are normally fitted one per hot outlet. The TM200VP can be fitted to serve several outlets provided that both the water supply pressures and mixed flow rates are adequate. To comply with health regulations, no tap should be more than two metres away from the mixing valve. Pump boosted storage Cold water tank Diagram 6 Multi-storey pump-boosted with high and low storage MU1H-1363GE23 R0608 5 Honeywell GmbH

10. Commissioning the TM200VP 1. Check that the designation of the TM200VP matches the intended application (Table 2), that the supply pressures are within the range of operating pressures and that the supply temperatures are within the range permitted for the valve from guidance information on the prevention of legionella. 2. Adjust the temperature of the mixed water following the instructions given in Setting the TM200VP, and the requirements of the application o record the temperature of the hot and cold supplies o record the temperature of the mixed water at the smallest and largest draw-off flow rates o turn off the cold water supply to TM200VP and record the mixed water temperature and the maximum temperature achieved The values should not be greater than 2 C of the nominal set point shown in Table 2. 11. Servicing 11.1General information Most domestic water supplies contain calcium which will separate out when the water is heated in a system. The degree and speed of scaling depends, amongst other factors, on water flow rates, system design, the degree of hardness of the water and the temperature to which it is heated. Over a period, scale may form within the valve, particularly at the hot inlet where the water is hottest and this may eventually prevent one or more ports from closing fully and thereby impair the temperature control. Descaling of the mixing valve then becomes necessary. Because circumstances differ between installations, it is not possible to give a definitive water hardness level which will affect the mixing valve within a certain time period. Simple scale protection of the incoming water supply on any system will always provide benefits in extending the efficient operating life of thermostatic mixing valves and other fittings before service is required. Scale protection is essential in applications where water is particularly hard. If purpose made measuring equipment is not readily available, a good guide to hardness can be established by checking site experience with speed of scale build up in kettles or coffee machines. 11.2Servicing It is recommended that the mixing valves are B inspected on a regular basis, at least annually, or more frequently if performance is impaired, to ensure they are working correctly and that dirt ingress into the system does not cause a loss in performance of the mixing valve. Please note that during servicing the valve piston should be greased with an approved (WRAS) silicon lubricant. If required, a Honeywell service kit is available for cartridge replacement. 1. Prior to servicing the TM200VP, the mixed water temperature must be recorded. Should the temperature be 2 C greater than the nominal setting the following should be checked before dismantling the valve o Check strainers are clean o Ensure check valves are in good working order o Check isolating valves are fully open 2. If these checks are satisfactory then the Honeywell service kit is available for cartridge replacement (separate instructions in the service kit detail this procedure). After servicing the commissioning procedure detailed in point 10 under Commissioning the TM200VP should be followed. Honeywell GmbH 6 MU1H-1363GE23 R0608

12. In-service testing Following commissioning, in-service tests (as shown in Commissioning the TM200VP ) should be carried out at 6-8 weeks and 12-15 weeks. 1. If no significant changes (i.e. 1K) occur in either test, a further inservice test should be carried out at 24 to 28 weeks after commissioning. 2. If small changes (i.e. 1 to 2K) occur in one test necessitating adjustment, a further in-service test should be carried out at 24 to 28 weeks after commissioning. 3. If small changes (i.e. 1 to 2K) occur in both tests necessitating adjustment, a further in-service test should be carried out at 18 to 21 weeks after commissioning. 4. If significant changes (i.e. > 2K) occur in either test necessitating service work, a further in-service test should be carried out at 18 to 21 weeks after commissioning. The general principle to be observed after the first 2 or 3 in-service tests is that the intervals of future tests should be set to those which previous tests have shown can be achieved with no more than a small change in mixed water temperature. GB MU1H-1363GE23 R0608 7 Honeywell GmbH

Honeywell Control Systems Ltd. Honeywell House Arlington Business Park Bracknell, Berkshire RG12 1EB T (0 13 44) 65 60 00 F (0 13 44) 65 62 40 www.honeywell.com/uk Automation and Control Solutions Honeywell GmbH Hardhofweg D-74821 Mosbach Phone: (49) 6261 810 Fax: (49) 6261 81309 http://europe.hbc.honeywell.com www.honeywell.com Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorised Representative Honeywell GmbH MU1H-1363GE23 R1363 Subject to change 2008 Honeywell GmbH