NEMA 4X Enclosure User Guide

Similar documents
Advantium 2 Plus Alarm

ATS Overhead Table Shelf System INSTRUCTION MANUAL

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Utility Distribution Systems

Ceiling Mount Air Handler Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Wireless Indoor/ Outdoor Thermometer

Instructions & Safety Information Models A220-20D and A220-20L Version 2

For Models #6-5001, #6-7501, # & #10-12K1

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

ADEMCO 4500 Thermostat

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

BroadBand PowerShield. User Manual

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Leak Detection System

INSTANT HOT WATER RECIRCULATING SYSTEM

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

, User s Manual

16/32 Channel 1U Rack Mount CCTV Power Supply

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Single Station Remote Alarm

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Alarm Clock USER GUIDE

User Manual (English)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Water Leak Detection System

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

USER S MANUAL HSC-24A

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

INSTALLATION INSTRUCTIONS PART NUMBER:

About this Manual. Support for Your Product

Nest Learning Thermostat Installation Guide. Installation step-by-step

Installation Instructions

Bottom Loading Water Dispenser

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Automatic Phone-Out Home Monitoring Systems

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

DUST COLLECTOR 70 GALLON, 2 HP

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Detection System Model 500 Series Owner s Manual

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

SunMaxx Solar Filling Station Operating Instructions

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

MTV-FS1 / FS1T / FSB375

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

ANT1750F Multi-Directional Slim Digital Antenna / Antena multidireccional plana para interiores / Antenne numérique mince multidirectionnelle

Mini Power Bank and Charger

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

Model 5101, 5102, 5103SL, 5110, 5111, 5115 STEEL SECURITY SAFE. Read this manual carefully and never store it inside the safe!

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

24.2L M.A.N. V12 Engine Module

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Part I - Installation

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Portable Air Conditioner

Say Hello to Your Precision Cooker

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

What you can expect from your Solar Hot Water System

Installation Instructions

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

i410/i1010 AC/DC Current Clamp

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

RGC-IR Remote Gas Calibrator for IR400

Universal Laptop Charger

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Installation Instructions: (Part # SB76880) XRC Armor Front Fender Kit

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

12-Volt 10-Amp Regulated Power Supply

3 WATT LED SPOTLIGHT Model No. SLM

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Transcription:

NEMA 4X Enclosure User Guide Anatel Corporation 2200 Central Avenue Boulder, Colorado 80301 U.S.A. Voice: Fax: Support Hot Line: E-mail: Website: (303) 442-5533 (800) 373-0531 (303) 447-8365 1-877-4 ANATEL (1-877-426-2835) info@anatel.com www.anatel.com Replacement Document Order P/N: FG5705301 Revision Date: March 2000 Internal Document Number: 19822301 Revision Number: 02 Initial Release Date: November 1999 Total Pages: 16

NEMA 4X Enclosure User Guide [FG5705301] Revision History Revision Date Comments 01 November 1999 Initial Release 02 March 2000 Miscellaneous changes Copyright 2000 by Anatel Corporation. All rights reserved. Printed in U.S.A. Specifications are subject to change without notice. Information contained in this manual is intended to assist Anatel s customers in the efficient use of Anatel products. Any other use of this Guide or the information contained herein is prohibited and the reproduction of this manual or its contents without the expressed written consent of Anatel Corporation is prohibited.

WARRANTY STATEMENT TEMENT 90-DAY LIMITED HARD ARDWARE WARRANTY Anatel Corporation (the Seller) warrants to the Buyer that the replacement parts and/or labor supplied by the Seller will be free from defects of material and workmanship for 90 days from the date of shipment. Seller s sole obligation under the foregoing warranties will be limited to either, at Seller s option, replacing or repairing defective goods or refunding the purchase price for such goods theretofore paid by Buyer; and Buyer s exclusive remedy for breach of such warranties will be forcement of such obligation of Seller. EXCL CLUSIONS These warranties will not extend to goods subjected to misuse, neglect, accident, improper installation or maintenance, or which have been altered or repaired by anyone other than an authorized representative of the Seller. WARRANTY LIMIT IMITATIONS TIONS The Seller makes no other warranty, either express or implied, with respect to this product. The Seller specifically disclaims the implied warranty of merchantability and fitness for a particular purpose. Some states, provinces or countries do no allow limitations on the duration of an implied warranty, so the above limitation or exclusion may not apply. However, any implied warranty of merchantability or fitness is limited to the 90-day duration of this written warranty. This warranty provides specific legal rights, and other rights may exist which vary from state to state, province to province, or country to country. EXCL CLUSIVE REMEDIES The remedies provided herein are the Buyer s sole and exclusive remedies. In no event shall the Seller be liable for any direct, indirect, special, incidental, or consequential damages, so the above limitation or exclusion may not apply. Anatel is a registered trademark of Anatel Corporation.

DECLARA ARATION OF CONFORMITY Manuf ufactur acturer er s Name: Anatel Corporation MANUF ANUFACTURER CTURER S ADDRESS DDRESS: 2200 Central Avenue Boulder, Colorado 80301, USA declares that the product NEMA 4X Instrument and Accessory Enclosure complies with the NEMA Type 4X definition which states that it is intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing of water, and hose directed water; undamaged by ice which forms on the enclosure. VP of Operations Anatel Corporation Boulder, Colorado The following international symbol is found on the enclosure: Protectiv otective e Earth (ground) Terminal Reference Document: IEC 417, No. 5017

NEMA 4X Enclosure User Guide SECTION PAGE 1. Introduction 6 2. Installation 8 3. Operation 14 4. Maintenance 15

SECTION 1. Introduction Introduction The NEMA 4X Instrument and Accessory Enclosure for Anatel s Access 643 and A-1000 S10 Stationary Sensor meets the universally accepted NEMA 4X specification for environmental protection, as well as Type 12 and Type 4 NEMA ratings. The enclosure, crafted of high-grade stainless steel, is sealed to withstand hose directed water. The shatter-proof window provides for visual inspection of the inside of the enclosure through the closed door. Sensors inside the enclosure detect power failures, ground fault interruptions, out of limit temperatures, and water leaks. When these conditions occur the red warning indicator flashes and power to the enclosure is turned off until the problems are corrected. The temperature sensor trips the flashing alarm when ambient temperature reaches 50 C. It automatically resets when the temperature cools to 35 C. The liquid sensor detects liquid that accumulates on the floor of the box. The flashing alarm LED is easily seen through the window in the door when indicating any of these conditions. A remote alarm connection is also provided to allow monitoring alarm conditions from a more convenient distant location. A lockable, cantilevered bracket on which the instrument is mounted swings away from the enclosure to allow for convenient testing and maintenance of the instrument. One 1/4 inch inlet connection and one 1/8 outlet connection are provided for the instruments, and one 3/8 inlet connection and one 1/4 outlet connection are provided for the heat exchanger, if that option is chosen. The installation kit includes properly sized adapters for installing either the Access 643 or the A-1000 S10 instruments with or without the heat exchanger option. Accessories available from Anatel for the NEMA 4X Instrument and Accessory Enclosure include a C80 Controller, a local printer, and digital analog convertor (DAC) modules to monitor temperature or conductivity, or both may be used to monitor temperature and conductivity of sample water. Where sample water exceeds 40 C the NEMA 4X may be equipped with an integrated heat exchanger which requires industrial cold water (ICW). The heat exchanger allows for testing sample water with temperatures above 40 C and up to 99 C. NEMA 4X USER GUIDE Page 6

SECTION 1. Introduction Components of the NEMA 4X include: 1. AC Power Terminal. The AC Power Terminal is used to connect the box to 120 VAC power. 2. Power Distribution Box. The power distribution box with AC switch, GFCI protected outlet, and electronics connection. The GFCI breaker protects all other outlets in the NEMA 4X box. The power distribution box houses no user serviceable parts. 2. Power Distribution Box 3. Power Connector Block 4. Air Circulation Fan 1. AC Power Terminal 5. Heat Exchanger 6. Remote Alarm Connector Block 3. Power Connector Block. The power connector block provides power outlets for all accessories. 4. Air Circulation Fan. Air is circulated within the box by the fan to mix the air and allow continuous heat transfer out of the box through its surface. 5. Heat Exchanger. The optional heat exchanger is factory installed. 6. Remote Alarm Connector Block. A remote alarm connector block provides a 10 ma, 5V maximum source for connecting either an audible or visual alarm monitoring. NEMA 4X USER GUIDE Page 7

SECTION 2. Installation NEMA 4X Installation tion Enclosure Anatel recommends that the NEMA 4X Instrument and Accessory Enclosure be mounted on a wall or specially built stand. The enclosure weighs over 100 pounds empty and over 118 pounds when all instruments are installed and requires a substantial mounting structure. The floor of the box should be level when the box is mounted. 28.5 When mounting, provide a minimum of a 1 standoff from the wall to allow for air circulation behind the enclosure. 1. Mounting. The back of the enclosure has four holes to be used for mounting bolts in the pattern shown at the right. The holes are.438 in diameter to accommodate 3/8 bolts. Bolts must be stainless steel and sealing washers must be used to maintain the NEMA rating. 28.5 Mounting bolt pattern. 2. Plumbing connections for units without a heat exchanger. If a heat exchanger is not used, the holes provided to access the water connections for the heat exchanger will be plugged. Connect sample water to the Instrument sample IN fitting shown in the diagram on the right. Connect the Water OUT fitting to a tube to the drain. 3. Plumbing connections for units equipped with a heat exchanger. If a heat exchanger is used the sample water must circulate through it for cooling before it is analyzed. Connect the ICW to the ICW IN and ICW OUT ports to circulate cold water through the heat exchanger. Connect the sample water to the Water sample IN fitting of the heat exchanger. Connect the Water sample OUT port to the Instrument sample IN port using the preshaped tubing with appropriate fittings found in the installation kit. Water sample IN Water sample OUT Water sample OUT ICW OUT Instrument sample IN Water OUT Water connections. NEMA 4X USER GUIDE Page 8

SECTION 2. Installation 4. Electrical connections. The NEMA 4X Enclosure requires a 120 VAC, 50/60 Hz supply. Make connections through the conduit on the left side of the enclosure (see photo). The circuit is protected with a 15A circuit breaker. AC input Electrical connection Power must be connected through the NMP 1/2 liquid tight conduit fitting using the appropriate conduit type (supplied by the buyer) to maintain the NEMA 4X rating. Power connection fitting. Connect to the terminal block according to the diagram on the right. Ground is connected at (the earth symbol), neutral at N, and line at L. Two of the terminals are not used and labeled as such. Not Used N Not Used L AC power terminal block connections diagram. NEMA 4X USER GUIDE Page 9

SECTION 2. Installation 5. ANET and remote alarm. Access for cables for the ANET connection and a cable for a remote alarm is also on the left side of the enclosure. Cables must be passed through the NMP 1/2 liquid tight conduit fitting using liquid tight conduit (supplied by the buyer) to maintain the NEMA 4X rating. Connect the remote alarm to the terminal provided in the box. ANET and remote alarm input conduit ANET and remote alarm. Installing the TOC Analyzer The NEMA 4X enclosure is compatible with the Access 643 and the A-1000 S10 and A-1000 XP Stationary Sensors. Mount the TOC analyzer of your choice on the hinged instrument mounting panel inside the enclosure. Each instrument requires different mounting screw locations shown in the photos at the right. Instrument mounting screw locations on the instrument mounting panel. NEMA 4X USER GUIDE Page 10

SECTION 2. Installation The installation kit includes two 1/8 diameter socket shoulder screws (8-32 x 1/2 ) to be installed in the upper holes of the instrument mounting panel. Install these screws in the appropriate locations and hang the instrument on the panel by its upper brackets. Socket shoulder screw. Install a 10-24 x 1/2 phillips head screw from the installation kit in the two lower brackets to secure the instrument. Connect the water sample line to the 1/4 inlet (labeled: Instrument sample IN) and 1/8 outlet (labeled: Water OUT) stainless steel compression fittings. The Access 643 Analyzer connections match these fittings. The A-1000 S10 outlet fitting requires a 1/4 to 1/8 adapter fitting to make the connection. All necessary fittings and tubing are included in the installation kit. (See the Anatel Access 643 TOC Analyzer User Guide or the A-1000 TOC Analysis System User Guide for more information.) Screws installed in lower brackets. NEMA 4X USER GUIDE Page 11

SECTION 2. Installation Optional Component Installation tion 1. Component location. The C80 Controller, local printer, and digital analog converters are located as in the photo on the right. Refer to component wiring connections on page 13. DACs C80 Controller Local printer Location of optional components. 2. C80 Controller. Insert the power cord, communications cable, and mounting clamp through the face of the bracket on the back of the NEMA 4X Enclosure. (See the photos on the right.) Screw the nut on the clamp until the C80 is firmly in place. See the Anatel Access 643 TOC Analyzer User Guide or the A- 1000 TOC Analysis System User Guide for further installation and operating information. C80 Controller. 3. Local printer. Insert the printer in the bracket on the back of the NEMA 4X Enclosure, plug in the power cord, and connect the printer as described in the Anatel Access 643 TOC Analyzer User Guide or the A-1000 TOC Analysis System User Guide. (See the photo of the printer installed on the right.) Local printer installed. NEMA 4X USER GUIDE Page 12

SECTION 2. Installation 4. Digital analog converters. If using one converter screw the two male/female hex standoffs into the back of the NEMA 4X Enclosure. Connect the module as described in the Anatel Access 643 TOC Analyzer User Guide or the A-1000 TOC Analysis System User Guide. If using both the temperature and conductivity modules, connect the two together with the male/female hex standoffs. They will not be tightly joined together. Connect the cable to the modules as described in the Anatel Access 643 TOC Analyzer User Guide or the A-1000 TOC Analysis System User Guide. (See the photo of two DACs installed on the right.) Two DACs installed. Power Distribution Box Power Connection C 80 AC Printer AC Printer DACs C 80 A 1000 Component wiring connections. NEMA 4X USER GUIDE Page 13

SECTION 3. Operation Operation Switch the power ON at the switch on the power distribution box. Turn the components ON and operate the instrument and all optional components as described in the Anatel Access 643 TOC Analyzer User Guide or the A-1000 TOC Analysis System User Guide. The NEMA 4X Instrument and Accessory Enclosure will protect the instrument and accessory components from potentially harsh environmental conditions for optimum performance. NEMA 4X USER GUIDE Page 14

SECTION 4. Maintenance Maintenance 1. The NEMA 4X Instrument and Accessory Enclosure requires minimum maintenance. Follow recommended maintenance and service procedures for the instrument and all accessory components installed in the enclosure. Refer to the Anatel Access 643 TOC Analyzer User Guide or the A-1000 TOC Analysis System User Guide. 2. From time to time test the GFCI circuit to be sure it is working properly. 3. Inspect the enclosure for signs of leaks. 4. Clean the stainless steel surface with an appropriate cleaner. CAUTION: Do not use abrasive cleaners on the window. Do not use steel wool to clean the stainless steel surfaces. 5. Check inside the box for printer paper that may pile up inside if not removed periodically. NEMA 4X USER GUIDE Page 15

If you have any questions,, contact Anatel Customer Support t toll free at t 1-877-4 ANATEL (1-877-426-2835)