How To Use A Digital Red Led Auto Thermometer Panel Meter

Similar documents
Small 7-key User-definable Remote Control User s Guide

0832 Dot Matrix Green Display Information Board User s Guide

Information Board User s Guide

Bluetooth Audio Receiver Board Starter Version User s Guide

6 X 100Watt Class-D Audio Amplifier Board- TDA7498 User s Guide

2 X 250Watt Class D Audio Amplifier Board IRS2092 User s Guide

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

High Power LED Driver Series User s Guide

12 Volt 30 Amp Digital Solar Charge Controller

AutoRanging Digital MultiMeter

40-Segment 2.54 pitch LED Bar Display Board User s Guide

Manual Ranging MultiMeter

Hand-held thermometer Model CTH7000

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Light Meter (Foot Candles)

Description. Dimensions. Features. precision works better

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

RS DIGITAL THERMOMETER

Duct Humidity Transmitter

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

PSC-A5 Solar Charge Controller Manual

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Xenon HID Lighting System

AN588 ENERGY HARVESTING REFERENCE DESIGN USER S GUIDE. 1. Kit Contents. 2. Introduction. Figure 1. Energy Harvesting Sensor Node

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Dual Laser InfraRed (IR) Thermometer

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

is then retained absolutely without interruption.

Dome Camera with IR Night Vision

HP4000EX Hardware Manual

INSTALLATION AND OPERATION MANUAL

Lab E1: Introduction to Circuits

Operating instructions IV / 2007

Dual Laser InfraRed (IR) Thermometer

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Dual Laser InfraRed (IR) Thermometer

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500 Series Low-Cost Data Loggers and Accessories

0.28" Quadruple Digit Numeric Displays. Technical Data Sheet. Model No.: KW4-281XSB

ramon 2.2 Radon Monitor manual

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

PWM-60 series IP67 TRC ELECTRONICS, INC

MINI MCR-SL-R-UI(-SP)

Terminal and Dimension

T0118 T2118 T3118. Instruction Manual

ABB Drives. User s Manual HTL Encoder Interface FEN-31

4-Channel Thermometer / Datalogger

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

LED...A Q Series Sealed High-Intensity

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Instruction Manual Temp 4/5/6 Temperature Meter Series

Dual Laser InfraRed (IR) Thermometer with Color Alert

Section D..General Auto Electrical Corporation

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16400(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JAN.19,2000 TOTAL PAGE : 7 APPROVED BY:

Mini InfraRed Thermometer with Laser Pointer

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS (LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : DEC.01,1999 TOTAL PAGE : 7 APPROVED BY:

Instruction Manual. T3111 T3111L T3111P T3111Ex

Digital Clamp-on DMMs with uncompromising performance

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

Wireless Data Logger Monitoring Systems

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

TC-9102 Series Surface Mount Temperature Controllers

USB-500/600 Series Low-Cost Data Loggers and Accessories

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

MILE Encoder for EC 90 flat

Hygro-Thermometer + InfraRed Thermometer Model RH101

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

SOLAR POWER - THE NEW WAY TO RV!

ECP & ECP240-32EX

Telefon (+45) Telefax (+45) Installation and operating manual

GREISINGER electronic GmbH

USER GUIDE. LED Light Meter. Model LT45

BITMAIN. APW PSU Series User Guide

Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy

Temperature & Humidity SMS Alert Controller

Solar Technology For Worldwide Applications M. TRUOT CEO OF A FRENCH COMPANY WORLDWIDE DISTRIBUTORS

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Solar Controller / Battery Charger User s Manual

Inductive Proximity Sensors

Model 201 Wiegand Touchpad Reader Installation Guide

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Business/ Home GSM Alarm System

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

User Manual for CH-PFC76810

1.50mm Height 2220 Package Top View Full Color Chip LEDs Technical Data Sheet. Part No.: LL-R5050RGBC-001

MSFET MICROSENS Miniature ph Sensor Module

Transcription:

0.56 " Digital Red LED Automobile Thermometer Panel Meter User s Guide 2004-2009 Sure Electronics Inc. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0

0.56" DIGITAL RED LED AUTOMOBILE THERMOMETER PANEL METER USER S GUIDE Table of Contents Chapter 1. Overview...1 1.1 Overview... 1 1.2 Main Features... 2 Chapter 2. Specification Characteristics...3 2.1 Specification Characteristics... 3 Chapter 3. Features...4 3.1 Adapted to the Ambient Brightness... 4 3.2 Slowly Adjust the Brightness of Diode... 6 Chapter 4. How to Use a Thermometer...7 4.1 Connection with Power Supply and Thermo Probe... 7 4.2 Display Mode Settings... 7 4.2.1 Display in &... 7 4.2.2 Select Display Temperature from CH1 or CH2... 8 Chapter 5. Mechanical Drawing...110 Chapter 6. Contact Us...121 2004-2009 Sure Electronics Inc. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page i

0.56" Digital Red LED Automobile Thermometer Panel Meter NOTES: Product Version : Ver 1.0 Document Version : Ver 1.0 ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page ii 2004-2009 Sure Electronics Inc

0.56" DIGITAL RED LED AUTOMOBILE THERMOMETER PANEL METER USER S GUIDE Chapter 1. Overview 1.1 Overview Thanks for using the thermometer of ME-SP33X series by Sure Electronics. Please read this manual carefully prior to the installation of thermometer. Thermometers of ME-SP33X series are the first LED-based self-made type. Aside from the features such as simplicity, self-adaptation to ambient brightness inherited from panel meter of ME-SP03X series, flexibility is the most impressive feature which provides 4 different versions that can suit the needs of global buyers. TABLE 1-1 MEMBERS OF ME-SP33X SERIES ME-SP33X SERIES S/N CH1 CH2 ME-SP330 - Built-in sensor ME-SP331 External Probe - ME-SP332 External Probe Built-in sensor ME-SP333 External Probe External Probe Thermometers equipped with built-in sensor, such as ME-SP330 and ME-SP332, can be used to measure temperature in household families, offices, PC rooms and vehicles. While external probe can help you extend your application range to some harsh environment, such as to measure the water temperature of vehicles, air-conditioners, refrigerators, water-heaters or the temperature of computer cases since the external probe itself is water-proof. As listed in the above table, ME-SP330 and ME-SP331 are equipped with a single built-in sensor and an external probe respectively. While ME-SP332 and ME-SP333 can measure temperature of two different applications since both of them are equipped with dual sensors. FIGURE 1-1 PRODUCT DIAGRAM 2004-2009 Sure Electronics Inc. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 1

0.56" Digital Red LED Automobile Thermometer Panel Meter FIGURE 1-2 ACCESSORIES Note: All diagrams or schematics in this manual are for reference only. 1.2 Main Features 1. C/ F selectable 2. Internal sensor or external thermo probe or a combination of both are provided 3. By the change of ambient brightness, thermometer will alternately display temp in C and F 4. Self adapted to ambient brightness, not dazzling in night time since the brightness can be adjusted automatically. 5. Large (0.56 /14.2mm) easy-to-read red LED display 6. Miniature housing 7. Ideal for automotive, industrial applications 8. -10 to +60 operating temperature range 9. Over 90% components are SMT based, which are reliable and environment-friendly 10. UL and CE-certified compound AWG22 cables are used, low voltage drop ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 2 2004-2009 Sure Electronics Inc

0.56" DIGITAL RED LED AUTOMOBILE THERMOMETER PANEL METER USER S GUIDE Chapter 2. Specification Characteristics 2.1 Specification Characteristics Power Supply Requirements Min. Typ. Max. Units Supply Voltage ME-SP33X 8.5 12 26 V Supply Current ( @ VCC = 12V ) Full Sunlight - 36 - ma Total Darkness - 13 - ma Performance Temperature Range Internal Sensor 32(0) - 140(60) F ( C) External Probe -31(-24) - 257(125) F ( C) Display Resolution -9.9 F ( C) to 99.9 F ( C) - 0.1 - F ( C) Other range - 1 - F ( C) Accuracy 0 C to 60 C External 0 ±1.0 ±1.5 C Internal 0 ±2.0 ±4.0 C Responding Rate: - 0.5 - S Display Display Type and Size Digit Display 3 digit, 0.56 /14.2 mm high LED F & C Display 1 digit, 0.39 /9.9 mm high LED Over-range Indication or no signal input ME-SP33X OL Physical/Environmental Operating Temperature -10-60 C Storage Temperature -40-75 C Humidity 0-85 %RH Note: The allowed input range of power supply is DC 8.5-26V, a higher voltage may burn out the thermometer. 2004-2009 Sure Electronics Inc. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 3

0.56" DIGITAL RED LED AUTOMOBILE THERMOMETER PANEL METER USER S GUIDE Chapter 3. Features The brightness of the diode varies with the change of ambient brightness and won t be too dazzling in night time. 3.1 Adapted to the Ambient Brightness 1. The brightness of diode will reach its topmost when the panel meter is in a room under direct sunlight exposure. 2. The brightness of the diode is comparatively high when the panel meter is placed in a room, around which the environment is similar to dawn, nightfall or cloudy weather. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 4 2004-2009 Sure Electronics Inc.

0.56" Digital Red LED Automobile Thermometer Panel Meter 3. The brightness of the diode is the darkest when the panel meter in placed in an environment of almost no light from outside. 2004-2009 Sure Electronics Inc. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 5

Features 3.2 Slowly Adjust the Brightness of Diode When the ambient environment of panel meter is shifted from light to dark or dark to light, the brightness of diode will be gradually changed and whole process will last for 1 seconds. The adjustment of brightness is smooth and it won t make people feel abrupt. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 6 2004-2009 Sure Electronics Inc

0.56" DIGITAL RED LED AUTOMOBILE THERMOMETER PANEL METER USER S GUIDE Chapter 4. How to Use a Thermometer 4.1 Connection with Power Supply and Thermo Probe FIGURE 4-1 CONNECTION SCHEMATIC Note: 1. VCC (+) and GND (-) shall be connected with the positive (+) and negative (-) of DC power supply ranging from 8.5-26V. 2. Pay more attention to polarity when hooking up, otherwise thermometer will be burnt out. 3. When an external probe (no matter a 2-pin or 3-pin version) is to be connected with the pin header of thermometer, always leave the pin +5V disconnected. 4.2 Display Mode Settings 4.2.1 Display in & Thermometer can display temperature in or, which can be set by K1 and K2 of DIP switch. K1 K2 Func. OFF OFF Display in ON OFF Display in OFF ON Alternate display with the change of ambient brightness( / ) ON ON No function Notes: 1. By setting K1 and K2, thermometer can alternately display temperature in and. 2004-2009 Sure Electronics Inc. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 7

How to Use a Thermometer 2. See following for steps of how to make the thermometer change its display from C(F)to F(C) with the change of ambient brightness C(F)to F(C): 1 Expose thermometer under intense light source (luminance intensity >=1000 Lux). 2 Cover thermometer with something to avoid being exposed under intense light (luminance intensity<=60lux). 3 Thermometer will start to change the current display from ( ) to ( ) if you repeat the above steps twice. Application example: You will need a flashlight to toss light directly on thermometer when ambient luminance intensity is less than 60 Lux and normally you will need to repeat the on & off action twice. You can also use flashlight even when the ambient luminance intensity exceeds 60 Lux, when you switch off the flashlight, cover your thermometer with your hands so that the luminance intensity can fall short of 60 Lux. 4.2.2 Select Display Temperature from CH1 or CH2 Thermometer allows you to select displaying temperature reading from CH1 or CH2, which can be achieved by setting k3 and k4 of DIP switch. K3 K4 Func. OFF OFF Display temp reading of CH2 ON OFF Display temp reading of CH1 OFF ON Alternate displaying automatically ( CH1 / CH2) ON ON Alternate display with the change of ambient brightness(ch1 / CH2) Notes: 1. Set K3 and K4 to OFF in terms of ME-SP330. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 8 2004-2009 Sure Electronics Inc

0.56" Digital Red LED Automobile Thermometer Panel Meter 2. Set K3 and K4 to ON and OFF respectively in terms of ME-SP331. 3. In terms of ME-SP332 and ME-SP333, thermometer can alternately display temperature of CH1 or CH2 by setting K3 and K4. 4. Thermometer will display temperature reading of CH2 if it were selected to do so. 5. Thermometer will display temperature reading of CH1 if it were selected to do so. 6. When you select to display temperature readings of both CH1 and CH2 automatically and alternately, thermometer will do so. Details are as follows: 1 Time interval for each change in between CH1 and CH2 is 4 seconds. 2 The displaying of CH1 and CH2 denotes the temperature displaying thereafter. CH1 means temperature reading from CH1 will be displayed and CH2 means temperature reading from CH2 will be displayed. 7. When Alternate display with the change of ambient brightness is selected, you can have thermometer display temperature readings of CH1 and CH2 alternately by changing the ambient brightness. Detailed steps are as follows: 1 Expose thermometer under intense light (make luminance intensity >=1000 Lux). 2 Cover thermometer with something to avoid intense light (make luminance intensity <=60 Lux). 3 Repeat the above steps four times and thermometer will change the current display from CH1 (CH2) to CH2 (CH1). 4 It takes approximately 9 seconds before the next prompt(ch1/ch2) can be displayed when the thermometer is in use. The display of CH1(CH2) denotes the display of temperature readings from CH1(CH2). Application example: refer to 4.2.1 2004-2009 Sure Electronics Inc. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 9

0.56" DIGITAL RED LED AUTOMOBILE THERMOMETER PANEL METER USER S GUIDE Chapter 5. Mechanical Drawing FIGURE 5-1 MECHANICAL DRAWING ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 10 2004-2009 Sure Electronics Inc.

0.56" DIGITAL RED LED AUTOMOBILE THERMOMETER PANEL METER USER S GUIDE Chapter 6. Contact Us Sure Electronics Co., Ltd. 5F, Zone A, Qinhuai Technology Innovation Center 105-2 DaMing Rd (ZIP:210022) Nanjing P.R.China Tel: +86-13601408832 (For technical questions only) +86-25-66606340 (English service, from GMT1-10AM) Fax: +86-25- 66606341-866 Website: www.sure-electronics.com www.sure-electronics.net 2004-2009 Sure Electronics Inc. ME-SP330 & ME-SP331 & ME-SP332 & ME-SP333_Ver1.0_Page 11