SunMaxx Solar Filling Station Operating Instructions



Similar documents
Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

BOWIE PUMPS OPERATION - MAINTENANCE

2" & 3" Poly Wet Seal Pump Instruction Manual

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Oil and Coolant Circulating Heating System. Model - OCSM

Assembly and instructions

IMPORTANT SAFETY NOTICE

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

Cooling system components, removing and installing

PBX Series Quick Fit Connector Bimetallic Steam Traps

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

CARING FOR YOUR WATER HEATER

Chapter 7 Hydraulic System Troubleshooting

MODEL G300 BRAKE BLEEDER

INSTALLATION & OPERATING INSTRUCTIONS

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Trouble Shooting. Pump

1/3 HP Submersible Sump Pump with Vertical Float Switch

IMPORTANT SAFETY RULES TO FOLLOW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Stainless Steel Single and Dual Circulation Kits

15GAL STEEL OIL DRAIN WITH 110V PUMP

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Cooling system components, removing and installing

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

ClearView 100. Instruction Manual

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

Volkswagen Golf > VW Rabbit GTI 2006->

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

AMX300 DirectConnect Mixing Valve Kits

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Installation Instructions S

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Operating Instructions Drill rig DRU160

VOYAGER 570G. 744A Sprayer Control

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

This instruction is valid for all ACD pump models shown on page 2

CHEMICAL CLEANING UNIT Product number:

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

Fire Pump Plan Review March 2010

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:

Hydraulic control unit series

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Goulds Water Technology

Section 7 Adjustment, Repair and Replacement

SERVICE MANUAL Order No.WH0911S001V0

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

Float and Thermostatic Traps Series H, C and X

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Standard Hydraulic Piping Flushing Procedure

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

Rules for Safe Operation

Please also see 10 golden rules for correct Saniflo installation on

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Portable Air Conditioner

CG PTFE Diaphragm Liquid Transfer Pump

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

SINGLE STAGE INLINE FIRE PUMP

400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP

Installation, Operation, Repair and Parts Manual

Infrarot-Bewegungsmelder IP44

NITROUS TRANSFER PUMP INSTRUCTIONS

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

B150 Series Commercial Brewer. Direct Plumb Kit

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Select Radiators Installation Guide

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

PC1130 Electric Air Compressor

Draining and filling cooling system

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

Model 1210C Battery Powered Pump Shown. Description

Transcription:

SunMaxx Solar Filling Operating Instructions

Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation... 7 6. Maintenance... 7 7. Troubleshooting... 9 8. Accessories... 10 9. Parts lists... 11 10. Technical data... 13 12 1

1. Declaration of conformity 2. Introduction The product complies with the requirements of the applicable european directives. The conformity was declared. The documents to which the declaration relates and the original declaration of conformity are available at the manufacturer. Intended use The filling unit is designed for filling, flushing and venting thermal solar systems and heat pump systems. Any other use or extended use is considered to be improper. The manufacturer is not liable for any resulting damage. Notes on the documentation This manual provides important information for a safe and correct operation of the solar filling unit Solarcheck Mobilcenter UNISTAR 2000-A. The manual is designed for qualified personnel who are trained and specialised in installing heating systems. Service and maintenance works must only be carried out by approved specialists. Subject to technical modifications The continuous development and improvement of our products may cause minor modifications of technical data and illustrations. 2.1 Legend Danger: immediate danger of death and severe injury Danger: danger of death from electric shock Danger: danger of scald burn Danger of environmental and material damage Information, note 2 2

2.2 General safety instructions Store these instructions in such a way that they are accessible at all times for operating personnel! In addition to these operating instructions the following documents of related components and of the pumping media should be applied: technical specifications material safety data sheets operating instructions The manufacturer shall not be held liable for damage resulting from nonadherence to the operating instructions. Danger Danger of death due to electric shock > Prior to work on the pump, always disconnect the drive from the power supply. Danger Danger Danger of death due to explosion > Do not pump any liquids with a flash point of less than 55 C. > Do not pump petrol or solvents. Danger of scald burn due to high media temperature > Fill the solar system only when cold if necessary cover the solar collectors. Danger of burn due to hot motor casing > Do not block either suction or pressure hose for more than 1 minute to avoid overheating of the motor. Warning Caution Danger of injury due to splashing liquid > Connect the hoses tightly to the pump. Material damage due to dry running > Never allow the pump to run dry for more than 1 minute. Material damage due to tilting of the cart on uneven ground > Operate the filling unit only on even ground. 3 3

Danger of environmental damage due to hazardous pumped media > Collect escaping pumped media and dispose of according to the locally applicable regulations. Material damage due to improper storage > Prior to extended periods of pump down time clean pump to avoid adhesions and damage to the impeller. > Store pump under frost-protected conditions. 3. Transportation and unpacking > After unpacking, immediately check the filling unit for completeness and damage. > Immediately report any transit damage to the supplying company. > Dispose of packaging material according to the respective local regulations. 4 4

4. Mounting and commissioning 1. Connect filling hose to pump outlet. 2. Connect return hose to tank. 3 1 2 3. Connect filling hose (1) and return hose (2) to the fill/vent valves and open valves. Close stop valve (3). 4. Fill tank and open ball valve. 5 5

5. Insert cable of pump motor into socket. 6. Switch on pump. 7. Open tank lid to ensure the circulation of the air. Caution: Monitor fluid level in the tank and, if necessary, refill heat transfer fluid to prevent air entering the solar circuit. 8. Flush the solar circuit with the fluid. Check at the vision panel of the filter or through the tank opening if there are still air bubbles in the heat transfer fluid. Continue flushing until there is no air remaining in the fluid. 6 6

5. End of operation After filling and flushing the solar system: > Switch off pump. > Close fill and vent valve (1+2) at the solar station. > Open stop valve (3) between fill and vent valve. Caution: Collect escaping pumped media in a container. By opening the drain valve at the pump outlet you can release the pressure that is generated between pump outlet and fill valve when flushing the pipe: > Turn the green handwheel of the drain valve at the pump outlet and let the remaining liquid run out. After that you can unscrew the filling hose easily from the fill valve: > Unscrew filling hose and return hose from fill and vent valve. > Screw open hose ends together with the provided connecting piece in order to avoid dripping or escaping of fluid during transport. 6. Maintenance Danger Caution Danger of death due to electric shock > Prior to work on the pump, always disconnect the drive from the power supply. Danger of environmental damage due to hazardous pumped media > Collect escaping pumped media and dispose of according to the locally applicable regulations. 6.1 Connections > Check regularly if hose couplings are tight. 6.2 Cleaning the filter There is a built-in fine filter on the suction side of the pump to filter out sold and welder residues. Check the vision panel at the filter regularly and clean the filter when you see dirt deposits on the strainer. > Screw off the filter casing, remove the strainer and clean both with rinsing water or compressed air. 7 7

6.3 Disassembling the pump 1. Disconnect line connections 2. Unscrew bolts on the pump side 3. Remove cover and side disc 4. Pull housing with impeller and rear side disc off the shaft 6.4 Replacing components Impeller To change the impeller we recommend to use a special tool. See chapter 8, Accessories. > Push impeller out of the casing > Insert a new impeller. Observe direction of impeller wings (see adjacent illustration): Impeller wings must be bent to the opposite side of the rotating direction. Lateral discs > Turn around or replace Intake Outlet Seals > Replace O-rings and push firmly into the recesses Replacing shaft gasket: 1. Remove retaining ring with suitable pliers 2. Push out bearing and shaft gasket 3. Push in new shaft gasket and bearing 4. Insert retaining rings 6.5 Assembling the pump Assembly of the pump is the reverse of disassembly see exploded drawing. 1. Connect lateral disc with punched hole to the rear of the casing 2. Push casing with impeller and second lateral disc onto the shaft 3. Insert and tighten bolts 4. Attach lines The lateral discs and O-rings must lie precisely in the recesses to ensure that the O-rings are not pinched. 8 8

7. Troubleshooting Fault Possible cause Remedy Pump does not take in liquid Pump does not build up pressure Liquid escapes from the pump Intake line is not leaktight Impeller worn or damaged Suction line or foot valve is blocked Pressure line closed or blocked Ball valve at the tank outlet closed or tank empty Impeller or lateral discs are worn Seal connection or line Replace impeller Clean suction line or foot valve Open fittings on the pressure side or clean pressure line Open ball valve or fill tank Replace impeller or lateral discs Filter clogged Clean filter (see chapter 6, Maintenance) Ball valve at the tank outlet closed Shaft gasket or O-ring is missing or defective Open ball valve Check whether part is in place and insert or replace defective component Pump does not start Impeller blocked Fill pump with the medium to be pumped Impeller clogged up or macerated Use an impeller appropriate to the medium Motor defective Have motor checked by specialist personnel and have repaired if necessary 9 9

8. Accessories Multifunction valve with bypass for mixing the heat transfer medium on-site Kit for filling ground loops including two 150 litre tanks, hose extension, additional stop valves and multifuncion valve to switch the suction line from external tanks to internal tank Remote control with 10 metre cable Tool for changing the impeller A useful tool to install the impeller easily into the casing. Suitable for all ZUWA impellers. Order No.: 110 124 00 tool for changing the impeller 10 10

9. Parts lists 30 60 71-73 70 40 20 10 80 Pos.: Part / Designation SKU Quantity 10 Chassis 13405110BT 1 20 Inflatable wheel 80120 2 30 30 litre tank 13405 1 40 Steam suction hose 13 x 6 30026 1 60 Steam hose 13 x 6 3 m 131123 2 70 T-piece brass 3 x ¾ internal thread 80110 1 71 Reducer plug ¾"- ⅜" internal thread 132236 1 72 Drain valve ⅜" 132232 1 73 Threaded nipple brass ¾" x ¾" external thread 131215 1 80 Pressure pipe filter series 324-o ½" int. thread 53240T0235 1 11 11

10. Technical data SUNMAXX FILLING STATION Voltage 110 V Frequency 50 Hz Maximum power consumption 370 W Maximum fluid temperature Approved pumping media Maximum operating pressure Maximum flow rate with water / heat transfer medium Diameter return hose / pressure hose 176 F water, heat transfer medium 70 psi 8 / 87 gallons/min ½ / ½ inches Tank content 8 gallons Motor protection class IP 55 Dimensions (height x width x depth) 39 x 19.5 x 21 inches Weight without packaging (empty tank) 46 pounds 12 13