APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out



Similar documents
Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Uninterruptible Power Supply

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Model #: SMART2200CRMXL

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

MAJORSINE Power Inverter

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Dell Smart-UPS 1,500 3,000 VA

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Installation and Operation Back-UPS 1250, 1300, 1500

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Back-UPS Pro 1300/1500 Installation and Operation

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Smart-UPS On-Line 230 V

PowerGem Pro Uninterruptible Power Supply

Internet Office 500VA Tower Standby 120V UPS with USB port

Online UPS. PowerWalker VFI 1000R/1U

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

User Manual 1K/2K/3K Online UPS

R5000 Uninterruptible Power System (UPS) Overview

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

How To Use A Power Supply Unit (Upu)

R5000 Uninterruptible Power System (UPS) Overview

BC Pro UPS System Standby UPS System

APC Smart-UPS 2400/3000 VA 100/ VAC 3U. Uninterruptible Power Supply

User s Manual Before using the inverter, you need to read and save the safety instructions.

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

220/230/240V. Smart-UPS 220/230/240V. Versatile, high density power protection for computer networks, telecommunications, and industrial applications

LAP ENERGIA PARA DATACENTERS

USER MANUAL Online UPS 1K/2K/3K

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

User s Manual AURORA 1.2K/2.2K

Cisco Redundant Power System 2300

750VA/1000VA/1500VA 100/120/230VAC 2U

USER MANUAL Online UPS 1K/2K/3K Rack

Thyristor-controlled power supplies and battery chargers

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Internet Office UPS System Standby UPS for PCs, workstations and more

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

User Manual. English. APC Smart-UPS RT. 3000/5000/6000 VA VAC Tower/Rack Mount 3U Uninterruptible Power Supply

User Manual. English. APC Smart-UPS RT. 8000/10000 VA Vac Tower/Rack-Mount 6U Uninterruptible Power Supply

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Installation and Operation

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Powerware 5110 UPS User s manual

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

User s Manual. Professional Rack Mount LCD Series PR1000ELCDRT2U/PR1500ELCDRT2U/ PR2200ELCDRT2U K

Tough Decision: On-Line or Line-Interactive UPS?

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Galaxy VM. Three-phase power protection. schneider-electric.com

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

The UPS for the highest security in industry and data centres

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

IBM 9910 Uninterruptible Power Systems safeguard your equipment and data from power problems

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Transcription:

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software, Smart UPS signalling RS-232 cable, User Manual Standard Lead Time: Usually Ships within 2 Weeks

Matrix-UPS Features & Benefits Availability Automatic internal bypass Intelligent Battery Management Hot-swappable batteries Hot-swappable modules Scalable runtime Automatic self-test Manageable external batteries Battery modules connected in parallel Automatic restart of loads after UPS shutdown Modular design Adaptability Supplies utility power to the connected loads in the event of a UPS overload condition or fault. Maximizes battery performance, life, and reliability through intelligent, precision charging. Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Ensures clean, uninterrupted power to protected equipment during Power Module replacement. Allows additional run time to be quickly added as needed. Periodic battery self-test ensures early detection of a battery that needs to be replaced. Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime. Delivers higher availability through redundant batteries. Automatically starts up the connected equipment upon the return of utility power. Provides fast serviceability and reduced maintenance requirements via selfdiagnosing, field-replaceable modules. Adjustable voltagetransfer points tightening the output voltage regulation. Maximizes useful battery life by widening the input voltage window or Plug-and-Play external Ensures clean, uninterrupted power to the loads when adding extra runtime to batteries the UPS. Field-replaceable Ensures compatibility with equipment that has different plug types. power distribution panel Manageability SmartSlot LCD display Serial Connectivity InfraStruXure Manager Compatible Serviceability User-replaceable batteries Predictive failure notification User-replaceable batteries User-replaceable power modules Audible Alarms Protection Customize UPS capabilities with management cards. Alpha-Numeric Display which displays system parameters and alarms. Provides management of the UPS via a serial port. Enables centralized management via the APC InfraStruXure Manager. Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Provides early-warning fault analysis ensuring proactive component replacement. Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Enables simple upgrades and replacements of the Power Modules. Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.

Power conditioning Boost and Trim Automatic Voltage Regulation (AVR) Protects connected loads from surges, spikes, lightning, and other power disturbances. Gives higher application availability by correcting low and high voltage conditions without using the battery.

Output Output Power Capacity 3750 Watts / 5000 VA Max Configurable Power 3750 Watts / 5000 VA Nominal Output Voltage 120V,208V Efficiency at Full Load 93% Output Voltage Distortion Less than 5% at full load Output Frequency (sync to mains) 57-63 Hz for 60 Hz nominal Crest Factor up to 5 : 1 Waveform Type Sine wave Output Connections (6) NEMA 5-15R (1) NEMA L14-30R (2) NEMA L6-30R Bypass Internal Bypass (Automatic and Manual) Input Nominal Input Voltage Input Frequency Input Connections 208V 60 Hz +/- 5 Hz NEMA L6-30P Cord Length 1.83 meters Input voltage range for main 156-252 (208) / 176-282 ( 240V)V operations Other Input Voltages 240 Batteries & Runtime Battery Type Typical recharge time Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof 3.30 hour(s) RBC Quantity 2 Replacement battery cartridge note The MX5000 ships with 2-SmartCell's. There is no RBC available for a standard SmartCell. If a SmartCell-XR is being used,then an RBC14 may be purchased. Typical Backup Time 27.8 minutes (1875 Watts) at Half Load Typical Backup Time 10.2 minutes (3750 Watts)

at Full Load Runtime Chart Extended Run Options Matrix-UPS APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out Communications & Management Interface Port(s) Available SmartSlot Interface Quantity Control panel Audible Alarm Emergency Power Off (EPO) DB-9 RS-232,SmartSlot 1 Multi-function LCD status and control console Alarm when on battery : distinctive low battery alarm : configurable delays Yes Physical Maximum Height 683.00 mm Maximum Width 351.00 mm Maximum Depth 452.00 mm Net Weight 137.73 KG Shipping Weight 155.91 KG Color Beige Units per Pallet 1.00 Environmental Operating Environment 0-40 C Operating Relative Humidity 0% Operating Elevation 0-3000 meters Storage Temperature -15-45 C Storage Relative Humidity 0% Storage Elevation 0-15000 meters Audible noise at 1 meter from surface of unit Online Thermal Dissipation 60.00 dba 900.00 BTU/hr Conformance Regulatory Approvals CE,CSA,FCC Part 15 Class A,UL 1778 Standard Warranty 2 years repair or replace,optional on-site warranties available,optional extended

warranties available **The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.

8.0 Storing the UPS 8.1 Storage Conditions The UPS should be covered and stored in a cool dry location. The UPS should be stored with the Battery Packs in a fully charged state. That is, the reported battery capacity should be at 100% before the UPS is switched off for storage. Disconnect the Battery Packs from the UPS and from each other (where applicable). Store the Battery Packs in an upright position. 8.2 Extended Storage To achieve expected run time following extended storage, the UPS should be allowed to refresh the Battery Packs every 6 months in environments where the ambient temperature is -15 C to +30 C (5 F to 86 F). For extended storage in environments where the ambient temperature is +30 C to +45 C (86 F to 113 F), the UPS should be allowed to refresh the Battery Packs every 3 months. 9.0 Specifications Note: Where specification ratings differ, values for the UPS configured for 240 Vac operation are given in brackets [ ]. 9.1 Input Nominal input voltage: single phase 208 Vac [240 Vac]. Nominal input frequency: 60 Hz. On-line efficiency @ full load: > 92%, > 93% with fully charged batteries for the 3000VA and 5000VA models, respectively. Input circuit breaker: 20 Amp, 30 Amp; for the 3000VA and 5000VA models, respectively. Input connector: NEMA L6-30P (250V/30A). 9.2 Transfer Characteristics Frequency limits for on-line operation: 60 Hz, ±5%. Input voltage limits for on-line operation: -25% to +15% of the nominal input voltage. Transfer to/from on-battery: 0 ms typical with computer loads, 1.5 ms maximum. Transfer occurs synchronous with the utility voltage phase. Transfer to/from bypass: Transfers to and from bypass occur synchronously with the utility voltage phase. Transfers both to and from bypass mode occur in 0 ms typically. 9.3 Output Characteristics Maximum load: 3000 VA or 2250 W @ 0.75 power factor; 4700 VA or 3750 W @ 0.8 power factor [5000 VA, 3750 W @ 0.75 power factor] for the 3000VA and 5000VA models, respectively. Nominal output voltages: 208 Vac / 120 Vac [240 Vac / 120 Vac]. On-line voltage regulation: ±5%. When "Auto" or "Low" utility failure sensitivity is selected by the user, the output voltage regulation may become relaxed to +5%, -12%. On-line frequency regulation: 60 Hz, ±5% (synchronized to the utility). On-battery output voltage regulation: ±5%. On-battery output frequency regulation: 60 Hz, ±0.1 Hz unless synchronized to utility frequency during utility brownout. On-battery output voltage total harmonic distortion: < 5%.

Protection: overcurrent and short circuit protected, latching shutdown upon overload. Output connections: (6) NEMA 5-15R receptacles, (1) NEMA L14-30R receptacle, and (2) NEMA L6-30R receptacles. 9.4 Noise and Surge Isolation Isolation: galvanic isolation, output neutral bonded to ground. Normal mode EMI/RFI noise attenuation: 40 to 60 db over 100 khz to 30 MHz range. Common mode EMI/RFI noise attenuation: 40 to 60 db over 100 khz to 30 MHz range. Normal mode let-through: < 1% of applied ANSI C62.41 Category A or B ±6 kv test. Common mode let-through: < 2% of applied ANSI C62.41 Category A or B ±6 kv test. 9.5 Battery Pack Battery type: spill proof, maintenance free sealed lead-acid. Nominal battery pack voltage: 48 Vdc. Typical battery life: 3 to 6 years (depends upon number of discharge cycles and normal ambient temperature). Recharge time: see table in section 9.9. Maximum number of Battery Packs: limited only by desired recharge time. 9.6 Environment Operating temperature: 0 C to 40 C (32 F to 104 F). Storage temperature: -15 C to 45 C (5 F to 113 F). Operating and storage relative humidity: 0 to 95%, non-condensing. Operating elevation: 0 to 3,000 m (10,000 ft). Storage elevation: 0 to 15,000 m (50,000 ft). Electromagnetic immunity: IEC 801-2, 801-3, 801-4, 801-5; severity level III or IV. Audible noise: < 55 dba at 1 m (3 ft). 9.7 Physical UPS dimensions (EU and IU mated): 17.8" H x 13.8" W x 17.8" D (45.2 x 35.1 x 45.2 cm). Battery pack dimensions: 9.1" H x 6.9" W x 17.8" D (23.1 x 17.5 x 45.2 cm). UPS weight (EU and IU mated): 145 lb (65.8 kg), 176 lb (79.8 kg) for the 3000VA and 5000VA models, respectively. Electronics Unit (EU) weight: 40 lb (18.1 kg), 45 lb (20.4 kg) for the 3000VA and 5000VA models, respectively. Add 8 lbs (3.6 kg) for shipping independent of IU. Battery pack weight: 64 lbs (29.0 kg). Add 5 lbs (2.3 kg) for shipping independent of UPS. Total shipping weight - 3000VA model: 244 lb (110.7 kg). Includes weight of packaging, mated EU and IU, and one (1) Battery Pack. Total shipping weight - 5000VA model: 344 lb (156.0 kg). Includes weight of packaging, mated EU and IU, and two (2) Battery Packs. Color: beige. 9.8 Approvals Safety approvals: UL per 1778, CSA per C22.2. EMC verification: FCC, CDC Class A verified.

9.9 Typical On-Battery Run Times Typical On-Battery Run Time Versus Load, 3000 VA Matrix-UPS with SmartCells, in Hours Number of SmartCells Computer Load (VA) 1 2 3 4 5 6 7 8 250 3.07 7.20 11.56 15.93 20.29 24.65 29.02 33.38 500 1.46 3.52 5.80 8.24 10.69 13.13 15.57 18.01 1000 0.57 1.46 2.46 3.52 4.58 5.80 7.02 8.24 1500 0.33 0.83 1.46 2.11 2.81 3.52 4.23 4.99 2000 0.22 0.57 0.99 1.46 1.93 2.46 2.99 3.52 2500 0.17 0.46 0.78 1.18 1.59 1.99 2.45 2.90 3000 0.13 0.36 0.62 0.92 1.25 1.59 1.92 2.30 Recharge Time, in Hours 1.2 2.8 2.7 3.8 4.9 6 7 8.1 Calculations based on loads with a.75 power factor. Lower power factor loads will yield higher run times. Run times are typical at 25 C (77 F). Recharge times to 90% of rated capacity after discharge into 50% of rated load. Typical On-Battery Run Time Versus Load, 3000 VA Matrix-UPS with SmartCell XR Battery Packs, in Hours Number of SmartCell XR Battery Packs Computer Load (VA) 1 2 3 4 5 6 7 8 1000 3 6.75 10.75 14.75 18.75 22.75 26.75 30.75 1500 1.8 4.3 6.9 9.5 12.1 14.7 17.3 19.9 2000 1.2 3 5 7 9 11 13 15 2500 0.9 2.4 4 5.6 7.2 8.8 10.4 12 3000 0.75 1.8 3.25 4.7 6.15 7.6 9.05 10.5 Recharge Time, in Hours 3.8 8.1 12.5 16.9 21.3 25.7 30.1 34.5 Calculations based on loads with a.75 power factor. Lower power factor loads will yield higher run times. Run times are typical at 25 C (77 F). Recharge times to 90% of rated capacity after discharge into 50% of rated load.

Typical On-Battery Run Time Versus Load, 5000 VA Matrix-UPS with SmartCells, in Hours Number of SmartCells Computer Load (VA) 2 3 4 5 6 7 8 500 3.07 5.02 7.20 9.38 11.56 13.75 15.93 1000 1.46 2.46 3.52 4.58 5.80 7.02 8.24 1500 0.83 1.46 2.11 2.81 3.52 4.23 4.99 2000 0.57 0.99 1.46 1.93 2.46 2.99 3.52 2500 0.46 0.78 1.18 1.59 1.99 2.45 2.90 3000 0.36 0.62 0.92 1.25 1.59 1.92 2.30 4000 0.24 0.42 0.62 0.83 1.08 1.33 1.59 5000 0.17 0.31 0.46 0.62 0.78 0.98 1.18 Recharge Time, in Hours 2.8 2.7 3.8 4.9 6 7 8.1 The case of one SmartCell does not apply to 5000 VA Matrix-UPS. Calculations based on loads with a.75 power factor. Lower power factor loads will yield higher run times. Run times are typical at 25 C (77 F). Recharge times to 90% of rated capacity after discharge into 50% of rated load. Typical On-Battery Run Time Versus Load, 5000 VA Matrix-UPS with SmartCell XR Battery Packs, in Hours Number of SmartCell XR Battery Packs Computer Load (VA) 1 2 3 4 5 6 7 8 1000 3 6.75 10.75 14.75 18.75 22.75 26.75 30.75 1500 1.8 4.3 6.9 9.5 12.1 14.7 17.3 19.9 2000 1.2 3 5 7 9 11 13 15 2500 0.9 2.4 4 5.6 7.2 8.8 10.4 12 3000 0.75 1.8 3.25 4.7 6.15 7.6 9.05 10.5 4000 0.53 1.25 2.25 3.25 4.25 5.25 6.25 7.25 5000 0.37 0.9 1.6 2.4 3.2 4 4.8 5.6 Recharge Time, in Hours 3.8 8.1 12.5 16.9 21.3 25.7 30.1 34.5 Calculations based on loads with a.75 power factor. Lower power factor loads will yield higher run times. Run times are typical at 25 C (77 F). Recharge times to 90% of rated capacity after discharge into 50% of rated load.