UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 DOUBLE PIPE HEAT EXCHANGER



Similar documents
UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE CONVECTIVE HEAT TRANSFER

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE ABSORPTION OF CARBON DIOXIDE INTO WATER

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

VAPOR PRESSURE AS A FUNCTION OF TEMPERATURE. This laboratory covers material presented in section 11.8 of the 9 th Ed. of the Chang text.

XControls Bring Applications to Life

CHEG 3128 Heat, Mass, & Kinetics Laboratory Diffusion in Laminar Flow Regimes Modeling and COMSOL Tutorial Tutorial by Andrea Kadilak

HEAT TRANSFER ENHANCEMENT ON DOUBLE PIPE HEAT EXCHANGER BY WIRE COILED AND TAPER WIRE COILED TURBULATOR INSERTS

AMX300 DirectConnect Mixing Valve Kits

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

Transmitter Interface Program

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Installing the IF-NMEASC & SC30 Windows XP Drivers & Software

FILLING AND PURGING THE SYSTEM

Vertical Tube Heat Exchanger (VTHX) or The Heat Exchanger Network (HEN) Control Process. Operating Manual

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Experiment 3 Pipe Friction

Using Excel to find Perimeter, Area & Volume

AN EXPERIMENTAL STUDY OF EXERGY IN A CORRUGATED PLATE HEAT EXCHANGER

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

Shell and Tube Heat Exchanger

SA-9600 Surface Area Software Manual

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Stainless Steel Single and Dual Circulation Kits

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions

Heat Exchangers - Introduction

Only smart people read the manual.

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

INSTALLATION INSTRUCTIONS BL-8704

Quick Start Guide See Inside for Use and Safety Information

Experiment # 3: Pipe Flow

INSTALLATION INSTRUCTIONS MK-8704

Florida Atlantic University VPN Client Installation Guide

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

(S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26)

Spreadsheets and Laboratory Data Analysis: Excel 2003 Version (Excel 2007 is only slightly different)

Small Animal Respiratory Exchange Ratio (RER)

Quick Reference Guide

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Network Camera. Quick Operation Guide V4.0.1

Dash 8Xe / Dash 8X Data Acquisition Recorder

SAGEM TM 1201/1241 V2

HERZ-Thermal Actuators

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

High kw Electric Tankless Water Heater Troubleshooting Guide

Rexroth Hydraulic Pump A10VO Series User Manual

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Laddomat Charging unit

User manual. Atec. 086L0130 Rev. 1 EN

Zebra GC420t User Guide VIF-NA-BG-125, V3.0

Dash 18X / Dash 18 Data Acquisition Recorder

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

User Manual. For more information visit

HEAT TRANSFER IM LECTURE HOURS PER WEEK THERMODYNAMICS - IM _1

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.6, pp ,

Installation Instructions S

BOREHOLE SEALING IN A COAXIAL HEAT EXCHANGER BY BENTONITE TREATMENT

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Floor Heating Warehouse.co.uk

MAINTENANCE & TROUBLESHOOTING

User manual. 086U6297 Rev. 9 EN

Introducing AUDIT- BUDDY

Description of functions

OnDemand Version 1.7. Installation Manual and User s Guide. AST Technology. Sophienstrasse Herford Germany

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

North Carolina State University Emergency Facilities Closure Checklist- Part I

Installing a Probe. Typical Installation

THRUST CURVE LOGGER V-4.200

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

Computer Networks I Laboratory Exercise 1

Measurement of Specific Heat Capacity Using Differential Scanning Calorimeter

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Watts Pure Water Systems

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Online Monitoring User Guide

Kurz MODBUS Client User s Guide

Calibration of Glassware

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Vaporization of Liquid Nitrogen

GenStore Archive Cabinet

Manual. Sealer Monitor Software. Version

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

How To Replace A Reverse Osmosis Water Tank

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

EScribe. EScribe at a glance

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Error Codes: 02F. Model: (110. = Whirlpool) S/N: CSP Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer

LUNG VOLUMES AND CAPACITIES

Model 288B Charge Plate Graphing Software Operators Guide

Bottom Loading Water Dispenser

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

M V Intake Manifold INSTALLATION INSTRUCTIONS

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

Transcription:

UNIVERSITY OF MINNESOTA DULUTH DEPARTMENT OF CHEMICAL ENGINEERING ChE 3211-4211 DOUBLE PIPE HEAT EXCHANGER OBJECTIVE Determine the Reynolds number for each flow. Determine the individual heat transfer coefficients for the inside and outside of the tube. Determine the experimental overall heat transfer coefficient, U, (based on the inside area of the hot tube and the log mean temperature) and the theoretical overall heat transfer coefficient, U, (based on the inside area of the hot tube and the individual heat transfer coefficients). Compare the calculated data for the parallel and co-current flows and the laminar, transition and turbulent flows (dependent on which ones you were asked to collect data for). INTRODUCTION In many heat transfer processes, heat is transferred from one fluid to another through a solid wall. The exchanger geometry, fluid properties, and flow rates are the parameters that influence the rate of heat transfer. A study of these parameters forms the basis for design of heat exchangers. A double pipe heat exchanger is a simple, low cost configuration normally preferred for applications requiring heat transfer areas less than about 10 m 2. REFERENCE Your text on Heat Transfer Holman, J.P., "Heat Transfer", McGraw Hill, Fifth Edition, New York, N.Y., 1981, Chapter 10, pp 437-467 McCabe, W.L., Smith, J.C., Marriott, P., "Unit Operations of Chemical Engineering", 4th Edition, McGraw-Hill, 1985 1

EQUIPMENT 1. Double pipe heat exchanger (Technovate 9052) 2. Digital thermometer 3. Stopwatch 4. 2-1 gallon plastic bottles 5. Calipers 6. Open end wrench 7. Samples of heat exchange tubes. 8. Top loading balance CHEMICALS/MATERIALS 1. Hot water 2. Cold water 2

Figure 1. Model 9052 Flow Diagram PROCEDURE Collect flow and temperature data in both the parallel and counter flow modes using hot water flowing through the inner pipe. The possible combinations of flow regimes are shown in Table I. The lab instructor will inform each group prior to the lab which flow mode(s) and flow rates to use in the experiment. 3

Table I. Experimental Flow Rates HOT WATER COLD WATER Laminar (Re<2100) Transition (2100<Re<4000) Turbulent (Re>4000) Laminar (Re<2100) Transition (2100<Re<4000) Turbulent (Re>4000) Laminar (Re<2100) Transition (2100<Re<4000) Turbulent (Re>4000) Laminar (Re<2100) Transition (2100<Re<4000) Turbulent (Re>4000) The configuration of the heat exchanger is shown in Figure 1. Counter flow or parallel flow is chosen by switching valve V-17. Counter-clockwise (ccw) for parallel flow and clockwise (cw) position for counter flow. 1. Calculate the flow rates at which laminar, transient and turbulent flow will occur [(gm/sec) or (ml/sec)]. You should know prior to the lab experiment how to calculate the Reynolds number for both the hot and cold water flows in the heat exchanger. 2. Ensure that all the valves in the system are closed. Open the two green handle water shut off valves located below the heat exchangers on the wall. 3. Fully open the flowmeter output valve V-15, the drain valve V-16, the cold water supply valve V-5, the hot water inlet valve V-2 and the mixer output flow control valve V-4. 4. For the first set of experimental temperature readings, set valve V-17 to parallel or counter flow depending on which mode you are to collect data in. For hot water, valve V-3 should be closed. Adjust the hot and cold water flows with valves V-13 and V-14 respectively. You can switch valve V-18 to divert either hot or cold water flow through the flow meter to get an approximate flow. Actual flow rates should be determined volumetrically by weighing a volume of water collected over a period of time. Note: Flow rates in the laminar range are very small. 5. Allow the heat exchanger to reach steady state. (Note: This may take up to 20 minutes on initial start up due to the long lag time in the building hot and cold water piping, especially when water is not being used frequently. After initial start up, steady state should be reached within a minute or two. Monitor temperatures to determine when steady state is reached.) 6. If the experiment is run using the computer for data acquisition, Appendix A will be attached and should be consulted before proceeding to the next step. 7. Record the temperatures and the flow rates (weight of liquid collected over a period of time) of the hot and cold fluids. The temperatures are monitored through the use of 4

thermocouples IT-9 and IT-11 for the hot fluid; OT-1 and OT-6 for the cold fluid; and ST-1, ST-2 and ST-4 for the outer surface temperature of the inner tube. If the computer data acquisition program is used, the data from each thermocouple will be collected every second. Six hundred (600) data points for each thermocouple will be collected over a period of 10 minutes. Hot and cold water flows should be collected in triplicate during this period of time. 8. The hot and cold water flows should be recorded on paper and entered into the spreadsheet after the temperature data has been collected (the run finished). If you press Enter or click on another cell to enter data into a cell at the same time that data is being entered into a cell by the data acquisition system, the data acquisition system will lock up and you may lose your data. You will have to restart the run. (There are times when the computer will have to be rebooted.) 9. The spreadsheet should be saved after each run. 10. Adjust the flow rates to the next desired flow rate. Repeat steps 5-7. 11. Reverse V-17 if you have to collect data in the opposite mode and repeat steps 5-8. The heat exchanger should reach steady state within a minute or two. Monitor temperatures to determine when steady state is reached and then start data collection. 12. Continue adjusting flow rates and repeat steps 4-8 until temperature data is collected for all the modes and flow rates you have been assigned. 13. Upon completion of this experiment, close both of the green handle water shut-off valves under the unit. Allow the water to drain out of the system. Then close all valves tight and back off 1/4 turn. SAFETY NOTES 1. Safety glasses with side shields shall be worn at all times during the experiment. Hot and cold water is used in this experiment under building main pressure reduced to approximately 30 psi. There is a chance of a tube bursting or a valve leaking water and start to spray the area around the area of the heat exchanger. 2. Prior to operation of the system, familiarize yourself with the equipment. Trace all process lines, test all valves, and ensure that all valves are closed. 3. Cold water should be admitted first and then the hot water in order to avoid damage due to thermal expansion. 4. While admitting hot water to the system, open the valves cautiously and check all connections for possible leaks. 5. At the end of the experiment, the hot water supply should be shut off first. Allow the cold water to circulate for a couple of minutes before shutting off the cold water supply. 6. Be aware of unlagged hot water lines, they heat up rapidly. 7. If a valve appears tight or doesn't yield to hand force, do not attempt to turn it with a wrench. Turn off the hot water, permit the system to drain and cool down, then loosen the packing bonnet slightly and try again. 5

8. Keep the laboratory working space clean and uncluttered. Be aware of potential hazards such as wet spots or debris on floors that could cause slips or falls. WASTE DISPOSAL PROCEDURES 1. There is no waste associated with this experiment. Only hot and cold water are used in this experiment and they can be sent to the drain. 08/2012 6

APPENDIX A Double Pipe Heat Exchanger Computer Data Acquisition Instructions The temperature data is collected with a DATAQ DI-1000TC Instrumentation module for Temperature measurement. The software program WinDaq/Lite will be used for data acquisition. 1. Connect the thermocouple (TC) wires to the DI-1000TC box. 2. Connect the USB cable from the DI-1000TC box to the USB port on the portable computer. 3. Turn on the computer and select the student account in Windows XP. Enter student as the password. Wait for Windows XP to finish loading. 4. Double click on the WinDaq 1000TC shortcut icon on the desktop to load the data acquisition software. 5. A window opens (DI-1000 Acquisition 0) showing an oscilloscope tracing of the temperatures for 7 thermocouples. The data as it is displayed moves from left to right. When the cursor reaches the right side of the window it starts again at the left side of the graph. The mode of data display can be changed but this is probably the best way to view the data on the monitor. 6. The software has been configured to collect 1 data point/sec/tc (7 samples/sec). Over a 10 minute period 600 temperature data points are collected for each thermocouple. The number of data points/sec/tc and the length of the sample time can be changed but for this experiment, this is the best configuration. If it is not set up right, see the Lab Services Coordinator. 7. Set up the heat exchanger in the proper configuration so it is operating to your satisfaction. 8. During the 10 minute period you collect temperature data you will also collect 3 sets of hot and cold water in 1 gallon white buckets for your mass flow data. 9. On the computer desktop, double click on the Excel icon to start Excel. 10. A small dialogue box appears on the spreadsheet. This dialogue box is named WinDaq- XL. Click on the circle in this box to open up another dialogue box. a. Under Select the WinDaq Device click on DI-194 Serial Device (xx) b. In the Starting Cell entry field, enter the cell designator for the upper left corner where you want to begin putting the data. A1 is the default. If you want to begin in another row or column enter that cell designator. c. In the Rows to Fill entry field enter 600. 600 data points will be collected over the 10 minute period (10 min x 60 sec/min x 1 data point/sec) for each thermocouple. When 600 data points have been collected the program will stop importing the data into the spreadsheet. d. Click on start to begin data acquisition. 7

11. The program automatically puts EC in each of the columns in the first row of the designated starting cell. 12. The thermocouple name for each column is listed below. They are the same as channels 1, 2, 3, 4, 5, 6, 7 shown on the oscilloscope chart in the data acquisition program. Column 1 Column 2 Column 3 Column 4 Column 5 Column 6 Column 7 NOTE: IT-9, Hot Water in IT-11, Hot Water out OT-1, Cold Water in/out (dependent on whether parallel/counter flow) OT-6, Cold Water in/out (dependent on whether parallel/counter flow) ST-1, Surface temperature 1 (Temperature of the outside surface of the inside [hot water] tube. ST-2, Surface temperature 2 (Temperature of the outside surface of the inside [hot water] tube. ST-4, Surface temperature 4 (Temperature of the outside surface of the inside [hot water] tube. ST-3, Surface temperature 3 has a broken thermocouple so it cannot be used. 13. The data from additional experimental runs can be put to the right of the previous run. Data can not be collected in columns beyond column HZ. Data from each experimental run can also be put into a new sheet. 14. Do not enter data into the spreadsheet while it is collecting data from Windaq. If you press Enter or click on another cell to enter data into a cell at the same time that data is being entered into a cell by the data acquisition system, the data acquisition system will lock up and you may lose your data. You will have to restart the run. (There are times when the computer will have to be rebooted.) 15. The spreadsheet should be saved after each run. 08/2012 8

Department of Chemical Engineering Stockroom Checkout slip Double Pipe Heat Exchanger ChE 3211 Name: (print name) Date: Lab No.: Lab 1 Tuesday 12:00-4:50 PM Lab 2: Thursday 12:00-4:50 PM Lab No.: Lab 3 Tuesday and Thursday morning (9:30-11:50 AM) (circle one) Equipment Out In Equipment Out In Stopwatch Calipers Name: (Signature) 9