The Calculation of G rms



Similar documents
ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

Electrical Resonance

Lock - in Amplifier and Applications

RANDOM VIBRATION AN OVERVIEW by Barry Controls, Hopkinton, MA

Introduction to Digital Audio

Tamura Closed Loop Hall Effect Current Sensors

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

RF Measurements Using a Modular Digitizer

The front end of the receiver performs the frequency translation, channel selection and amplification of the signal.

Computer Networks and Internets, 5e Chapter 6 Information Sources and Signals. Introduction

VCO Phase noise. Characterizing Phase Noise

Improving A D Converter Performance Using Dither

SOFTWARE FOR GENERATION OF SPECTRUM COMPATIBLE TIME HISTORY

Direct and Reflected: Understanding the Truth with Y-S 3

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

SIGNAL PROCESSING FOR EFFECTIVE VIBRATION ANALYSIS

How to avoid typical pitfalls when measuring Variable Frequency Drives

PeakVue Analysis for Antifriction Bearing Fault Detection

PHYS 331: Junior Physics Laboratory I Notes on Noise Reduction

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

How to compute Random acceleration, velocity, and displacement values from a breakpoint table.

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

Lab #9: AC Steady State Analysis

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Frequency Response of Filters

Q1. The graph below shows how a sinusoidal alternating voltage varies with time when connected across a resistor, R.

Acceleration levels of dropped objects

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

FAST Fourier Transform (FFT) and Digital Filtering Using LabVIEW

PROCEDURE: 1. Measure and record the actual values of the four resistors listed in Table 10-1.

Principles of Adjustable Frequency Drives

Transistor Characteristics and Single Transistor Amplifier Sept. 8, 1997

FREQUENCY CONTROLLED AC MOTOR DRIVE

CHAPTER 6 Frequency Response, Bode Plots, and Resonance

MICROPHONE SPECIFICATIONS EXPLAINED

LAB 12: ACTIVE FILTERS

Dithering in Analog-to-digital Conversion

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

electronics fundamentals

Basics of Digital Recording

Analysis/resynthesis with the short time Fourier transform

The Fourier Analysis Tool in Microsoft Excel

Switch Mode Power Supply Topologies

Physics 623 Transistor Characteristics and Single Transistor Amplifier Sept. 13, 2006

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Lecture 1-6: Noise and Filters

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

CIRCUITS LABORATORY EXPERIMENT 3. AC Circuit Analysis

Experiment 3: Double Sideband Modulation (DSB)

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

LABORATORY 10 TIME AVERAGES, RMS VALUES AND THE BRIDGE RECTIFIER. Bridge Rectifier

Auto-Tuning Using Fourier Coefficients

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION

Analog Filters. A common instrumentation filter application is the attenuation of high frequencies to avoid frequency aliasing in the sampled data.

Accurate Measurement of the Mains Electricity Frequency

Trigonometric functions and sound

SIGNAL PROCESSING & SIMULATION NEWSLETTER

Decoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.

PRACTICAL GUIDE TO DATA SMOOTHING AND FILTERING

SR2000 FREQUENCY MONITOR

Similar benefits are also derived through modal testing of other space structures.

Introduction to Digital Filters

Basic Acoustics and Acoustic Filters

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b

Chapter 8 - Power Density Spectrum

Programmable-Gain Transimpedance Amplifiers Maximize Dynamic Range in Spectroscopy Systems

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

Current and Temperature Ratings

Lab 1: The Digital Oscilloscope

Measuring Impedance and Frequency Response of Guitar Pickups

Filter Comparison. Match #1: Analog vs. Digital Filters

Spectrum Level and Band Level

ANIMA: Non-Conventional Interfaces in Robot Control Through Electroencephalography and Electrooculography: Motor Module

Lab 1. The Fourier Transform

Designing Gain and Offset in Thirty Seconds

Network Theory Question Bank

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

Introduction to Receivers

Section 3. Sensor to ADC Design Example

A Sound Analysis and Synthesis System for Generating an Instrumental Piri Song

MATRIX TECHNICAL NOTES

The accelerometer designed and realized so far is intended for an. aerospace application. Detailed testing and analysis needs to be

SUMMARY. Additional Digital/Software filters are included in Chart and filter the data after it has been sampled and recorded by the PowerLab.

AC : MEASUREMENT OF OP-AMP PARAMETERS USING VEC- TOR SIGNAL ANALYZERS IN UNDERGRADUATE LINEAR CIRCUITS LABORATORY

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Active Vibration Isolation of an Unbalanced Machine Spindle

Exploring the Necessity of the Hot Hipot Test

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

What you will do. Build a 3-band equalizer. Connect to a music source (mp3 player) Low pass filter High pass filter Band pass filter

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES NQF LEVEL 3 OUTCOME 4 - ALTERNATING CURRENT

Cell Phone Vibration Experiment

Basics of Structural Vibration Testing and Analysis

Introduction to FM-Stereo-RDS Modulation

Optimizing VCO PLL Evaluations & PLL Synthesizer Designs

Transcription:

The Calculation of G rms QualMark Corp. Neill Doertenbach The metric of G rms is typically used to specify and compare the energy in repetitive shock vibration systems. However, the method of arriving at the G rms measurement (input signal filtering, cutoff frequency of the measurement) can have a dramatic effect on the value. It is important to understand how the measurement is made, and to understand its limitations, in order to use it effectively. This paper will describe the metric of G rms, how it is calculated in both the frequency and time domains and what factors can cause variations in G rms calculations. What is G rms? Repetitive shock (RS) vibration systems produce a continuously varying pseudorandom broad spectrum vibration. A typical real time signal from an accelerometer mounted on an RS table is shown in figure 1. The root mean square (rms) value of this signal can be calculated by squaring the magnitude of the signal at every point, finding the average (mean) value of the squared magnitude, then taking the square root of the average value. The resulting number is the G rms metric. (Note: Since this paper addresses G rms calculations specifically, all of the discussion here assumes a signal source that is representative of g s (acceleration). However, the discussion would apply equally well to any measured signal.) Figure 1. Typical acceleration signal from an RS vibration system

Consider for a moment what the case would be if the signal from the accelerometer on the table were a sine wave rather than the complex signal you see in figure 1. The rms value of a sine wave is easy to calculate from the real time signal it is simply the peak value of the sine wave times the square root of two. The resultant number would be the G rms value for that vibration level. Similarly, the rms value of the signal shown in figure 1 can be calculated. However, since this irregular signal is not described by a straight-forward equation, it is not possible to directly calculate the rms value like you can for a sine wave. Fortunately, there are other methods for calculating the rms value of the signal. Calculating G rms from a real time signal If you need to continuously measure the rms value of a signal in a system for example, to control the vibration level of a repetitive shock vibration system one straightforward method is to employ analog rms converter circuitry 1. rms to DC converter chips are available commercially that produce an output voltage proportional to the rms value of the input signal (figure 2). Adding an input filter to the circuit will limit the frequency range of the signal that is being measured. A microprocessor based control circuit could easily monitor the output rms signal, display a G rms value and control the vibration system to maintain a G rms setpoint. Figure 2. Block diagram of rms converter chip (Source: Analog Devices data sheet, AD736) Another method is to perform the rms calculation digitally. This is done by first sampling the analog input signal, yielding a sequence of numbers corresponding to the magnitude of the input signal at each sampled point. The rms calculation now is fairly straightforward. First, each value is squared. Then, all the values are averaged together. A final square root calculation yields the rms number. This method requires the use of the appropriate anti-aliasing filters and sampling circuitry to insure an accurate measurement of the signal across the frequency range of interest. Calculating G rms from a frequency domain signal Even though the G rms signal can be easily described as a time domain measurement, it is typically thought of as a frequency domain measurement taken from the Power

Spectrum, or Power Spectral Density, curve. A brief review of the basics of Fourier theory will make this method of determining G rms clearer. When G rms is calculated using Power Spectrum information it is often thought of as the area under the curve of the Power Spectrum display. More accurately, it is the square root of the integral of the Power Spectrum 2. This calculation results in the same G rms value as obtained through the time domain measurements thanks to Parseval s Theorem. Parseval s Theorem (figure 3) states that the energy of a signal is the same whether calculated in the time domain or the frequency domain 3. Since the Power Spectrum display is in units of G 2, the integral of the Power Spectrum, or the area under the curve, satisfies the right side of Parseval s Theorem, while the summation of the squared values of the digitally sampled time domain signal satisfy the left side of the equation. Taking the square root of each side results in equivalent G rms calculations. h 2 ( t) dt = H ( f ) 2 df Figure 3. Parseval s Theorem When you look at the Power Spectrum of a typical vibration signal (figure 4) one thing that can be confusing is the units of the Y axis. For a Power Spectrum, the units are shown as g 2/ Hz, or often G rms 2 /Hz. In this case, the rms is not referencing the rms calculation in the time domain described above. Rather, it is an indication of the measurement used for the sinusoidal components represented in the Fourier Transform. The Fourier Transform of a signal shows the frequency and amplitude of the sine waves that, when summed, would form the time domain signal. If the amplitude of these sine waves is measured as an rms value, then the resultant Y axis units for the Power Spectrum in the frequency domain is G 2 rms /Hz. Indeed, the definition of the Power Spectrum requires that the units be in this form. 2 While some spectrum analyzers will allow choices of Y axis units that include G 2 rms /Hz, g 2 peak /Hz, etc., the only units that result in a Power Spectrum (and hence that can be used to directly calculate G rms as described above) are G 2 rms /Hz.

Figure 4. Power Spectrum of an RS vibration system Variations that affect G rms calculations If you use the G rms metric to specify or compare the performance of RS machines it is very important that you understand how the measurement method, and specifically the cutoff frequency and input filtering, can affect the resultant calculation. Any use of the G rms metric should include a clear description of these parameters to allow it to be interpreted correctly. If you examine the Power Spectrum display and consider that G rms is proportional to the area under that curve, you can immediately see that the cutoff frequency used for the G rms calculation can greatly affect the value calculated. With a broad band signal such as is generated from a repetitive shock vibration system, the difference between a calculation based on a 2.5 khz cutoff frequency and a 5 khz cutoff frequency can be very dramatic (figure 5j). Comparing two systems based only on the G rms calculated to 2.5 khz can result in erroneous conclusions.

Figure 5. rms calculation using two different cutoff frequencies. Similarly, a specification of G rms in specific frequency bands can provide a method to more accurately specify a desired spectral content in a system. Some spectrum analyzers allow this calculation only over certain ranges. However, it is not difficult to calculate G rms over any desired range using stored data from the spectrum analyzer and a spreadsheet program. Another source of variation in G rms calculations can arise when rms converter circuitry is used. The analog input filter on the circuit affects the value in a way similar to the effects of cutoff frequency in the frequency domain measurement. By filtering the input you are limiting the frequency range of the signal that is used in the rms measurement. Just like in the frequency domain example above, a measurement done with rms converter circuitry with a 2 khz input filter will be very different from one done with a 5 khz input filter. Even more variables are introduced when you try to compare the G rms values from an analog rms converter circuit to those obtained from a spectrum analyzer. A typical rms converter circuit might have an input filter set at 5kHz. However, this filter may be a single or two pole filter with the cutoff being the 3dB point of the filter. This means that, while the energy beyond 5 khz has been attenuated as described by the roll-off of the filter, it has not been immediately reduced to zero past 5 khz, as is the case with the digital cutoff of the spectrum analyzer. Also, the analog filter in the rms circuitry attenuates the signal some before the 5kHz 3 db point as well. Consequently, the G rms value provided by the rms converter can be very different from the value provided by a spectrum analyzer even though they specify the same cutoff frequency.

These differences can vary based on the signal content. In the example being considered here, the presence or absence of a peak in the power spectrum at 5500 Hz would have no effect on the spectrum analyzer G rms value due to the sharp digital cutoff at 5000 Hz. However, if rms converter circuitry is used, some of the energy at 5500 Hz would still be included in the G rms measurement because it would not be completely attenuated by the filter. Conclusion It has been said that G rms is one of marketing s favorite specifications you can make it whatever you want, just by choosing the cutoff frequencies correctly! This isn t too far from the truth. The calculation can be made from both time domain and frequency domain data. Each method has it s own set of variables that can affect the calculation. There is no industry standard or preferred method for doing the calculation and different methods are used in different vibration systems. Before comparing G rms values from different machines it is important to know how the measurement was made. If you are using G rms as a test specification, be sure to specify the frequency range over which the measurement is taken, and filter specifications as necessary. This will help insure the accurate reproduction of your desired tests. References 1 Analog Devices, Application Note AN-256, RMS to DC converters ease measurement tasks 2 Steinberg, Dave S., Vibration Analysis for Electronic Equipment, John Wiley & Sons, 1988 3 Brighan, E. Orna, The Fast Fourier Transform, Prentice Hall, Inc., Englewood Cliffs, NJ, 1974