THE PFC >for fast cycle water vapor cryopumping.



Similar documents
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Recharge Procedure for Telemark TVP-2000 and TVP-3500

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

VDL 53 - Vacuum drying oven for flammable solvents

Research RF Sputtering Packages

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Failure code manual. content

WHOLESALE DIRECT INC WEST 65TH STREET

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Light Duty Commercial Electric Water Heater

Commercial Gas Water Heater

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

BB-18 Black Body High Vacuum System Technical Description

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

Commercial Refrigeration Temperature and Defrost Controls

Split units TH with hermetic compressors

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Why and How we Use Capacity Control

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Commercial Semi-Instantaneous Water Heaters

A/C refrigerant system, overview

T7079A,B Solid State Remote Temperature Controllers

In-Line Electronic Flow Switches

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Phone: Fax: Web: info@clrwtr.com

MCR1900 Media Converter 19-Slot Chassis

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

PANASONIC TROUBLE SHOOTING GUIDE

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

HP switch LP switch Discharge thermo Comp. Surface thermo

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

ECOCIAT. Domestic hot water heat recovery unit

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Element D Services Heating, Ventilating, and Air Conditioning

Refrigeration Compressed Air Dryer Buran Ultrapulse

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Commercial Gas Water Heaters

Conlift1, Conlift2, Conlift2 ph+

Defining Quality. Building Comfort. Heating and Cooling Coils

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS


KNC Model 3666 Automatic Pressure Calibration System

HL Series - Commercial Heaters Tankless Water Heating Solutions

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

INSTALLATION & SERVICE MANUAL. Display Panel

Model 1210C Battery Powered Pump Shown. Description

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Oil and Coolant Circulating Heating System. Model - OCSM

FIREDEX Conventional Fire Panels

In-Line Electronic Flow Switches

APC APPLICATION NOTE #112

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

SELECTION, APPLICATION AND MAINTENANCE

ASME Packaged Indirect Fired Water Heater

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

OZW30. Central Unit SYNERGYR

Heating, air-conditioning, cooling

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Hydraulic Control Solutions

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

DESIGN STANDARDS SECTION

AIR-COOLED CONDENSERS Technical Guide

Nirvana. Cycling Refrigerated Dryers

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

, User s Manual

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Designed for multi-injector endurance testing, the

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Vacuum drying oven for non-flammable solvents

Advantium 2 Plus Alarm

Analytical Instruments Smart Analyzer 90 Type SMA

Air conditioning, electrical testing

Heating oven with mechanical convection

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Basic Technology Series

Streaming Potential System (SPT1000, SPD1000)

Freezers - Ultrafreezers. Platilab & Irilab Series

ice 3 FLUID TO FLUID HEAT PUMP

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SYSTEM 45. C R H Electronics Design

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Fire Pump Plan Review March 2010

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Transcription:

P O L Y C O L D F A S T C Y C L E W A T E R V A P O R C R Y O P U M P S P E C I F I C A T I O N S CAPTURE WATER VAPOR AND CUT PUMPDOWN TIME BY AS MUCH AS 75% IN HIGH-VACUUM SYSTEMS THE PFC >for fast cycle water vapor cryopumping. pumps primarily water vapor and is used in conjunction with a conventional high vacuum pump. Increased product throughput of 20% to 100% Typical payback times of less than one year Lower water vapor partial pressure during processing for higher film quality, better adhesion and more reproducible deposition Superior in cost/performance to liquid nitrogen cooled Meissners THE PFC1100-100 to -150 C (-148 to -238 F, 173 to 123 K) Fast Start, Fast Defrost Tube-Type Cold Element (e.g., Cryocoil) Heat Removal to 3600 Watts Cryocondenses Water Vapor in Vacuum Systems with Speeds to 200,000 l/sec. Vacuum Levels to 1.5X10 -II torr Provides very fast pumping speeds for water vapor, which is typically 65% to 95% of the gas load in high vacuum systems. Increase product throughput in your existing system 20% to 100% and improve quality of deposition. The Polycold Fast Cycle Water Vapor Cryopump (PFC) effectively captures water vapor, which comprises 65% to 95% of the residual gas in highvacuum systems. Water vapor is typically the most reactive contaminant present. The PFC advantages include: High-vacuum pumpdown time cut by 25% to 75% When added to your vacuum system, the PFC Cryopump can dramatically reduce pumpdown times and increase product throughput. The PFC will pump water vapor within minutes from start and can defrost in less than seven minutes, giving true fast-cycle capability. For your system, this means more production cycles per shift. Pumpdown times are typically reduced by 25% to 75%, and increases in product throughput are 20% to 100%. Using Polycold s patented cryogenic refrigeration process, the PFC works on the principle of Meissner trapping. Water vapor is captured by condensation on a cryogenically cooled surface, called a Meissner coil. The Meissner (cryocoil) is mounted directly in the vacuum chamber so conductance is not limited by ports, manifolds, valves and baffles. The cryocoil is easy to install and can be adapted to fit any system. It does not need a high-vacuum valve. PFC Cryopumps are the most cost-effective pumping upgrade you can add to any diffusion-pumped, turbopumped or helium-cryopumped system. A control module allows you to have either local or remote operation, enabling you to operate the PFC from your existing controller or processor. The PFC is available in a variety of capabilities and cryocoil configurations. Models are available that control two cryocoils or the combination of a cryocoil and a baffle. For your diffusion-pumped chambers, the addition of one Model PFC/P provides cooling to the baffle to control backstreaming plus increased water vapor pumping speed in the chamber. The model PFC/PFC individually cools and defrosts two separate cryocoils. Please refer to Product Specifications and to our PFC Price List for price and option details. A lease/ purchase is available within the U.S.A. High-speed pumping of water vapor: 10,000 to 200,000 l/sec in the workspace 1

1 CRYOCOIL KEY SYSTEM COMPONENTS The cryocoil will be designed to fit the specific vacuum chamber, based on information you supply, or you may choose to design and build your own cryocoil. Typical cryocoils have helical, spiral, serpentine or other simple shapes. We do not recommend cryopanels; they slow the cool/defrost times due to increased mass and cryopump ineffectively on the rear side if positioned near the chamber wall. A stainless steel cryocoil, a complex cryocoil design or an adapter flange, may require additional costs. 2 FEEDTHROUGH To refrigerant line Max. wall thickness 47mm, 1.88" Return Feed 76mm 3.00" 152mm, 6.00" Hole diameter 52mm, 2.03" 283mm, 11.13" Air side To cryosurface Vacuum side The standard cryogenic feedthrough provides thermal isolation between the feed/return tubes and the O-ring seal. The dual pass feedthrough requires a two-inch diameter hole in the vacuum chamber. Couplings on the feed-through mate with the refrigerant line. Optional feedthroughs fit oneinch diameter holes, but two are required (one for each tube). Custom feedthroughs are available. 3 REFRIGERANT LINE Direction of refrigerant flow Return To PFC unit Feed Thermocouple wires (2) 2,440mm, 96.0" STANDARD INSULATED LINE To feedthrough 76mm, 3" A refrigerant line set consists of a copper feed and return line, each with stainless steel couplings on both ends for connection to the PFC unit and to the feedthrough. Longer lengths of refrigerant line (more than the standard 8 feet) can be ordered from the factory. However, if the line length is longer than 15 feet, it may be necessary to select the next larger PFC unit because of the additional heat load imposed by the longer line. Contact the factory for the cost of longer lines. 4 VACUUM INSULATED LINE Copper tubes wrapped with layers of super-insulation (Density 60 layers/inch). Vacuum space pumped to 10-torr-5 for 5 days & includes molecular getter material for long life. Return Feed _ Vacuum evacuation port & relief valve Optional length Corrugated stainless steel wall with protective polyolefin outer covering _ 76mm 3" HOW DO I SELECT THE RIGHT SIZE PFC UNIT TO TRAP WATER VAPOR IN MY VACUUM CHAMBER? PFC unit sizes are based on the desired water vapor pumping speed and the ability of the chamber to accommodate the required amount of cold element (cryocoil) surface area. The larger the cryocoil, the greater the pumping speed. Typically, we recommend an increase in chamber net speed of four times the existing (net in-chamber) water vapor pumping speed. This typically results in a pumpdown time reduction of from 25% to 75%. Once the approximate unit size and cryocoil surface area have been established, the required temperature and cooling capacity of the system are reviewed against the presence of any additional heat load (long refrigerant lines, process heat, etc.). WHAT IS THE BEST TO TRAP WATER VAPOR EFFECTIVELY? To find the cryosurface temperature that is best for your vacuum system, find the ultimate base pressure of your system listed below. Then follow across to the right column which shows the required cryosurface temperature. This temperature provides 90% water vapor trapping efficiency. DESIRED WATER VAPOR PARTIAL PRESSURE AVERAGE CRYOSURFACE NEEDED torr mbar C 5 X 10 0 6.7 X 10 0 25.4 2 X 10 0 2.7 X 10 0 34.4 1 X 10 0 1.3 X 10 0 40.8 5 X 10-1 6.7 X 10-1 46.8 2 X 10-1 2.7 X 10-1 54.3 1 X 10-1 1.3 X 10-1 59.7 5 X 10-2 6.7 X 10-2 64.8 2 X 10-2 2.7 X 10-2 71.2 1 X 10-2 1.3 X 10-2 75.8 5 X 10-3 6.7 X 10-3 80.1 2 X 10-3 2.7 X 10-3 85.6 1 X 10-3 1.3 X 10-3 89.6 5 X 10-4 6.7 X 10-4 93.4 2 X 10-4 2.7 X 10-4 98.2 1 X 10-4 1.3 X 10-4 101.6 DESIRED WATER VAPOR PARTIAL PRESSURE AVERAGE CRYOSURFACE NEEDED torr mbar C 5 X 10-5 6.7 X 10-5 104.9 2 X 10-5 2.7 X 10-5 109.1 1 X 10-5 1.3 X 10-5 112.2 5 X 10-6 6.7 X 10-6 115.1 2 X 10-6 2.7 X 10-6 118.1 1 X 10-6 1.3 X 10-6 121.5 5 X 10-7 6.7 X 10-7 124.1 2 X 10-7 2.7 X 10-7 127.5 1 X 10-7 1.3 X 10-7 129.9 5 X 10-8 6.7 X 10-8 132.2 2 X 10-8 2.7 X 10-8 135.2 1 X 10-8 1.3 X 10-8 137.3 5 X 10-9 6.7 X 10-9 139.5 2 X 10-9 2.7 X 10-9 142.1 1 X 10-9 1.3 X 10-9 144.1 HELPFUL INFORMATION FOR SIZING SYSTEMS RADIATION HEAT LOAD ON CRYOCOIL (At 25ºC Ambient Conditions) -376.6 Watts/m 2 (35 Watts/ft 2 ) Refrigerant Line Heat Load -26.3 Watts/m (8 Watts/ft) Vacuum Jacketed Line Heat Load -1.0 Watts/m (0.3 Watts/ft) Water Vapor Pumping Speed (Theoretical) -149,000 l/s/m 2 (13,842 l/s/ft 2 ) Liquid Nitrogen Cooling Approximately (45 Watts/ liter/ hour) SIMPLE WORK SHEET Ultimate Base Pressure Required Temperature: C Heat Load Cryocoil Heat Load Refrigerant Line: Additional Heat Load (Process Heat, etc.) Total Heat Load VACUUM INSULATED REFRIGERANT LINE POLYFLEX ADDS FLEXIBILITY OF CRYOPUMP PLACEMENT TO OPTIMIZE PRECIOUS FLOOR SPACE. 2

MODEL PFC CONFIGURATIONS (NOT TO SCALE; STANDARD REFRIGERANT LINE 8 FEET) BASE UNIT SYSTEM Standard 8 foot refrigerated line Couplings with stubs Customer s Vacuum Chamber Cryocoil PFC UNIT Cryogenic Vacuum Feedthrough PFC -STANDARD PFC FEATURES Factory-charged with CFC FREE refrigerant Temperature indicator with differential analog output Electronic controller to terminate defrost Control module for local manual control Remote connector to permit operation with your controller or your manual controls (remote operation requires relays, switches, and wiring by end-users). BASE UNIT SYSTEM OPTIONAL BAFFLE PFC/P -COMBINATION PFC AND P Includes all standard PFC features. Model PFC/P is typically used to temperature-cycle a crocoil and continuously cool a tubing trace-style chevron baffle as well. The cryocoil may be cooled or defrosted while the baffle remains cold. Total cooling capacity may be divided 1 2-1 2, or 2 3-1 3 between the two circuits. Note: (1) when one cryocoil is temperature-cycled, the baffle or other cryocoil temperature may vary about 1 to 10 degrees. (2) Baffles not included in system price. BASE UNIT SYSTEM OR OR PFC/PFC -MULTI-PURPOSE PFC AND PFC Includes all standard PFC features. The two cryosurfaces (consisting of: two cryocoils, coil and baffle or two baffles) can be cooled or defrosted separately. Total cooling capacity may be divided 1 2-1 2 or 2 3-1 3 between the two circuits. NOTE: (1) When one cryocoil is temperature-cycled, the baffle or other cryocoil temperature may vary about 5 to 10 degrees. (2) Baffles are not included in system price. PFC/PFC APPLICATION NOTE The intended application for a PFC/PFC configuration is for the operation of two cryocoils in different locations within a single in-line system. This configuration is also successful in the operation of cryocoils in two different load-locked systems. For batch systems we recommend a dedicated Polycold PFC per vacuum system. 3

D I A G N O S T I C S A N D C O N T R O L S F O R P F C, P F C / P, P F C / P F C 3 3 0, 4 0 0, 5 5 0, 6 7 0, 1 1 0 0 The operator interface (Control Panel) pictured at the right is used on the PFC model PFC 550 and larger PFC systems. This picture illustrates most of the options available. Included as standard in this module is a digital temperature meter (C) with a ten position thermocouple select switch (D). The switch allows monitoring of various temperatures within the system and at remote locations. Standard temperature monitoring points include: A B C D H Refrigerant Temperature High Discharge Temperature Light indicates that the temperature of the refrigerant was too hot at the compressor discharge. I Cooling Water Supply High Liquid Temperature Light Indicates loss of water, too little water, reversed flow or scale builtup inside the condenser. J Operating Indicator Light Indicates the compressor contactor has activated and no faults are included. Compressor Power On/Off 1 Compressor Discharge K On/Off Rocker Switch 2 Refrigerant Liquid Line 3 Cryocoil Feed (circuit 1)* 4 Cryocoil Return (circuit 1)* 5 Cryocoil Feed (circuit 2)* E F H I G AC Power Indicator Light (Located on High Voltage Box not shown). Indicates the Disconnect Switch is activated and AC power is on. PFC CIRCUIT 1 6 Cryocoil Return (circuit 2)* 7 Refrigerant Feed (circuit 1) 8 Refrigerant Return (circuit 1) 9 Coldest Liquid 10 Refrigerant Return (circuit 2)* *Customer re-assignable. Illustrated is an optional second temperature meter, set point relay and indicating lamp (A). The customer specifies the locations to be monitored with the set point relay and the meter. Not illustrated is an optional temperature set point relay with indicator lamp (B). The customer specifies the location to be monitored. SYSTEM CONTROL MODULE Fault Lights/Controls: Flow Diagram J L M N K (PFC Circuit 2 includes the same features as Circuit 1 and is available on PFC/ PFC Models.) L Remote/Local Control Switch The Remote feature allows the customer to control the PFC unit from a remote location via the customer s own equipment controller/computer. The local mode enables the Control Panel switches to be used to operate the unit. M Defrost/Standby/Cool Switch When the previous Remote/Local Control Switch (l) is in the Local position, the three (3) position rocker switch initiates all primary functions: Defrost - Standby - Cool. N Status Lights Indicates the operation mode: defrost complete, defrost active, standby, cool. COMPRESSOR PROTECTION DUAL PRESSURE SWITCH E Low Pressure Light Indicates that the compressor suction pressure dropped too low (refer to operating manual). F High Pressure Light Indicates that the compressor discharge pressure was too high (refer to Operating Manual). MODEL PFC CONTROL PANEL A THREE POSITION ROCKER SWITCH HANDLES ALL PRIMARY FUNCTIONS: DEFROST, STANDBY, AND COOL G Reset Button Resets any fault indicated on system control once the problem has been corrected. MODEL 330 DIGITAL PRESSURE AND INDICATORS 4

O P T I O N S F O R P F C, P F C / P, P F C / P F C 3 3 0, 4 0 0, 5 5 0, 6 7 0, 1 1 0 0 Indicates that the selected temperature is colder LAMP FOR SETPOINT A* OPTIONAL SECOND METER LAMP FOR SETPOINT B* STANDARD METER RELAY FOR SETPOINT A* LOCATION FOR RELAY FOR SETPOINT B* THERMOCOUPLE LIMIT SWITCH KNOB FOR SETPOINT A* EXTERNAL THERMOCOUPLE ENTRANCE THERMOCOUPLE SWITCH CONNECTIONS LIQUID LINE PROTECTION than the predetermined setpoint. Inside the module, the setpoint can be adjusted between -80C and -160C. When the temperature from the input thermocouple drops below the defined setpoint, a thermocouple limit switch lights a lamp on the panel and closes a relay contact that completes a circuit to the remote connector. Customer decides at time of purchase which location is to be dedicated to the setpoint. Part No. 600212-02. SECOND METER WITH SETPOINT RELAY Provides continuous readout of temperature and setpoint status for a second thermocouple position in a location of customer s choice. Part No. 600212-03 SETPOINT RELAY AND SECOND METER WITH SETPOINT RELAY If you would like to order both of the previous two items, please specify Part No. 600212-04. ISOLATED INTERFACE* ISOLATED ELECTRICAL INTERFACE FOR USER S CONTROLLER* If you want to control the PFC unit remotely with other than switch closures, your control voltage and the PFC unit must be electrically isolated. To meet this requirement, the optional isolated relay interface is available in 6, 12, or 24 volts, 50/60 HZ AC or DC. (Specify desired voltage at time of order.) 24V Part No. 600248-01 (for Model PFC) 24V Part No. 600248-02 (for Model PFC/PFC) 24V Part No. 600248-03 (for Model PFC/Ps) REMOTE INDICATOR METER This is a separate digital meter that is not installed in the PFC unit. It allows the user to read the analog output signal from the installed *OPTIONS temperature meter at a remote control panel up to 50 feet away. Part No. 353010-01 (For voltage 115 1 60) ISOLATED INTERFACE Part No. 353010-02 (For voltage 230 1 60) Part No. 353010-03 (For voltage 24 volts) Remote Meter with 50 foot electrical cable Part No. 840109-01 (For voltage 115 1 50-60) Part No. 840109-02 (For voltage 230 1 50-60) Part No. 840109-03 (For voltage 24 1 50 60) Options are only available at time of PFC unit order. For additional information and suggestions on how to use these options in your application, please request the Polycold Control Options Application Note. * Not available on the PFC 400. 5

COMPARISON OF CRYOPUMPING SPEED AND PRESSURE PFC330ST, PFC400LT, PFC550HC, PFC550LT, PFC670HC, PFC1100HC, PFC1100LT 220,000 200,000 PFC1100HC 180,000 WATER VAPOR PUMPING SPEED, L/S 160,000 140,000 120,000 100,000 80,000 60,000 (PFC1100ST) PFC670HC 40,000 PFC1100LT PFC550HC PFC550LT 20,000 PFC330ST PFC400LT 0 10-13 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 WATER VAPOR PARTIAL PRESSURE, TORR NOTE: For some operating conditions the cryocoils may be enlarged to provide greater pumping speeds 6

COMPARISON OF AVERAGE (A) CRYOSURFACE VS. HEAT LOAD(B) PFC330ST, PFC400LT, PFC550HC, PFC550LT, PFC670HC, PFC1100HC, PFC1100LT 100 110 PFC1100HC CRYOSURFACE, C 120 130 140 150 PFC400LT PFC330ST PFC550LT PFC1100LT PFC550HC PFC670HC 160 170 0 500 1000 1500 2000 2500 3000 3500 4000 HEAT LOAD, WATTS (a) Temperatures shown are the average of the inlet and outlet using recommended cryocoil size. (b) The temperature differences between inlet and outlet are typically 20 C at maximum load. The end point of each curve is the maximum load for that model. 7

PFC SPECIFICATIONS PFC330ST PFC400LT PFC550LT PFC550HC PFC670HC PFC1100LT PFC1100HC Typical Performance(a) Maximum load (Watts at warmest temperature) 400 200 400 1000 1500 800 3600 Theoretical max pumping speed l/sec(b) 29,800 29,800 37,250 74,500 104,300 74,500 298,000 Conservative pumping speed (in chamber) l/sec(b) 20,000 20,000 25,000 50,000 70,000 50,000 200,000 Ultimate operating pressure, torr(c) 2 X 10-7 2 X 10-10 4 X 10-10 6 X 10-9 6 X 10-9 1.5 X 10-1 2 1.5 X 10-8 Maximum pump start pressure, atm(d) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Time to defrost, minutes 3.0 4.0 3.0 4.0 4.0 3.0 7.0 Cryocoils and refrigerant lines Total cryocoil surface area m 2 (ft. 2 ).2 ( 2.2 ) 0.2 ( 2.2 ) 0.25 ( 2.7 ) 0.5 ( 5.4 ) 0.7 ( 7.5 ) 0.5 ( 5.4 ) 2.0 ( 21.6 ) Single circuit (PFC) Tube O.D., mm (in.) 10 ( 3 8) 8 ( 5 16) 10 ( 3 8) 12 ( 1 2 ) 16 ( 5 8) 12 ( 1 2 ) 16 ( 5 8) Tube length m (ft.) 6.37 ( 21.9 ) 8 ( 26.3 ) 7.95 ( 27.4 ) 13.3 ( 41.1 ) 14 ( 46 ) 13.3 ( 41.1 ) 40 ( 132 ) Dual circuit (PFC/PFC) Tube O.D., mm (in.) NA NA NA 10 ( 3 8) 12 ( 1 2 ) NA 16 ( 5 8) Tube length per coil, m (ft.) NA NA NA 7.96 ( 27.4 ) 9.28 ( 29 ) NA 20 ( 66 ) Standard refrigerant line lengths m (ft.) 2.44 ( 8 ) 2.44 ( 8 ) 2.44 ( 8 ) 2.44 ( 8 ) 2.44 ( 8 ) 2.44 ( 8 ) 2.44 ( 8 ) Utilities Cooling water, flow rate l/min. (gal./min.) at 13C ( 55F ) NA 2.7 ( 0.71 ) 4.9 ( 1.3 ) 4.9 ( 1.3 ) 6.8 ( 1.8 ) 13.6 ( 3.6 ) 13.6 ( 3.6 ) at 26C ( 79F ) 8.9 ( 2.3 ) 8.6 ( 2.3 ) 12.3 ( 3.2 ) 12.3 ( 3.2 ) 17.3 ( 4.6 ) 33.8 ( 8.9 ) 33.8 ( 8.9 ) at 29C ( 85F ) 19.5 ( 5.15 ) 19.0 ( 5.02 ) 19.7 ( 5.2 ) 19.7 ( 5.2 ) 27.6 ( 7.3 ) 54.1 ( 14.3 ) 54.1 ( 14.3 ) Power input, at maximum load, KW 3.6 3.6 6.0 6.0 8.3 11.8 19.2 Nominal power requirements(e) 200 3 50-60 200 3 50-60 200 3 50-60 200 3 50-60 200 3 50-60 200 3 50-60 200 3 50-60 (Volts/Phases/Hertz) 230 3 60 230 3 60 230 3 60 230 3 60 230 3 60 230 3 60 230 3 60 380 3 50 380 3 50 380 3 50 380 3 50 380 3 50 380 3 50 380 3 50 400 3 50 400 3 50 400 3 50 400 3 50 400 3 50 400 3 50 400 3 50 460 3 60 460 3 60 460 3 60 460 3 60 460 3 60 460 3 60 460 3 60 480 3 60 480 3 60 480 3 60 480 3 60 480 3 60 480 3 60 480 3 60 575 3 60 575 3 60 575 3 60 575 3 60 575 3 60 Max operating sound level, db(a)(f) 73 73 71 72 72 81 81 FOOTNOTES (a) Standard conditions for performance testing. 1 Cryocoil environment at 20 C 2 Recommend cryocoils and line lengths. 3 Cooling water temperature between 25 C and 28 C. (b) Larger cryocoils may give greater pumping speeds, and can be used in some applications. Contact your sales representative or the factory for application details. (c) Standard cryocoil at twenty-five percent (25%) of maximum pumping speed. (d) Recommended cryopump start pressure is near normal crossover. Mechanical roughing pumps and blowers are generally more effective for moisture removal above 1 torr. (e) For nominal power requirements not on the table, please contact the factory. Please refer to the manual for operational voltage ranges. For 480 volt operation the maximum voltage is 506. (f) Units were tested in a manufacturing environment under maximum load in the COOL mode. (g) To comply with the Safety Code for Mechanical Refrigeration, ANSI/ ASHRAE-15-1994, the following units should be located in a room no smaller than listed. NOTES All units have cryocoils that may be decoupled from the refrigerant lines and remote control capability with built-in remote connector. All models are water cooled. Maximum angle of inclination for shipping or handling all units is (45 ). Minimum room volume meters 3 (ft. 3 )(g) 141.6 ( 5,000 ) 141.6 ( 5,000 ) 130.2 ( 4,600 ) 155.7 ( 5,500 ) 212 ( 7,500 ) 340 ( 12,000 ) 354 ( 12,500 ) 8 9

PFC 1100, PFC 670, PFC 550 B H I B PFC 400 LT PFC 330 B C J C C F D A G A A E Model A B C D E F G H I J Weight Standard mm/inches kg./lb. Refrigerant Line PFC330 610 559 1651 211 8 ft. 24 22 65 NA NA NA NA NA NA NA 465 PFC400 610 559 1397 204 8 ft. 24 22 55 NA NA NA NA NA NA NA 450 PFC550 953 660 1842 812 140 254 203 432 114 1727 408 8 ft. 37.5 26 72.5 32 5.5 10 8 17 4.5 68 900 PFC670 953 660 1842 812 140 254 203 432 114 1727 478 8 ft. 37.5 26 72.5 32 5.5 10 8 17 4.5 68 1055 PFC1100 1054 711 1689 914 140 102 203 457 114 1562 544 8 ft. 41.5 28 66.5 36 5.5 4 8 18 4.5 61.5 1200 For each PFC model number, dimensions are identical for LT and HC versions. Combination or Multi-Purpose PFC Models have the same dimensions as the Standard PFC Models in the equivalent size unit. (For example, a PFC/PFC1100 has the same dimensions as a PFC 1100.) For PFC 550, PFC 670, and PFC 1100 (and corresponding Combination or Multi-Purpose PFC Models) allow 45 cm (18 inches) clearance for utilities, refrigerant line connection and controls on the right hand panel as seen viewing the front of the unit. POLYCOLD HEADQUARTERS UNITED STATES IGC Polycold Systems Inc. 3800 Lakewood Highway Petaluma, CA 94954 Phone 707.769.7000 Fax 707.769.1380 E-mail sales@polycold.com WORLDWIDE Contact the Polycold office closest to you for the name of the Polycold representative in your regional area. WORLD WIDE WEB Visit our site on the internet at www.polycold.com Call toll free within the U.S.A. Sales 888.4.POLYCOLD IGC Polycold Systems Inc. is a wholly owned subsidiary of Intermagnetics General Corporation 450 Old Niskayuna Road P.O. Box 461 Latham, NY 12110-0461 Phone: 518.782.1122 Fax: 518.783.2601. IGC Polycold Systems Inc. 6 02. Printed in U.S.A. All dimensions shown are typical. All specifications are subject to change without notice. Polycold is a registered trademark of IGC Polycold Systems Inc. 10