MODEL FAI4 FRESH AIR INTAKE KIT



Similar documents
MODEL MAC-3 MULTIPLE APPLIANCE CONTROL

MODELS WATER HEATER VENT PACKAGE. For Natural Gas or LP

DBF 4XL Dryer Booster Fans

AUTO-DRAFT INDUCER INSTALLATION INSTRUCTIONS MODELS D-3 XL

Installation Instructions

Cooktop Low-Profile Ventilation Hoods

ASX7-4-IOM-7 J

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

READ AND SAVE THESE INSTRUCTIONS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Ceiling Mount Air Handler Manual

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Exhaust Calculation Booklet

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

HV AC CODE CHECKLISTS

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

CHAPTER 4 VENTILATION

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Installation Instructions

Arapahoe County Residential Water Heater Installation and Inspection Guide

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Destiny Shower Enclosure Installation Instructions

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Vehicle Restraint Installation Manual

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Installation Instructions ERV/PRV Downdraft Vent

UV100A Ultraviolet Air Treatment System

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Single Family Residential Basement Finish

Ceiling Fan Installation Instructions

Advantium 2 Plus Alarm

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

HVAC Code Requirements

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Basement Development Construction requirements for the development of basements in residential dwellings.

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Accessory Manual Ventilation Section Model Comfort Circle

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

INSTALLER S & OWNER S MANUAL

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

INSTANT HOT WATER RECIRCULATING SYSTEM

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Your safety and the safety of others are very important.

4 Installation Requirements

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Copyright Puradigm, LLC HVAC Owner s Manual

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Packaged Terminal Air Conditioner Wall Sleeve Installation

AZEK Rail Install Guide

GAS SAFETY PRECAUTIONS

Guidelines for Earthquake Bracing of Residential Water Heaters

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Contract for Weatherization Management Address City & State

Elavo White Ceramic Round Vessel Bathroom Sink

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

RadianceRail Installation Guide

Gas-Fired, Residential Storage Type Water Heaters

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

AerAtron. Ceiling fans

Wireless Indoor/ Outdoor Thermometer

Installation, operation and maintenance manual TX 35A

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

3 IN 1 BATHROOM HEATER

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

Geyser-R Heat pump water heater Installation manual

Installation Guide. Bath and Wall Surrounds SERIES B

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

Ducoterra Radiant Heating Panel Installation Manual

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

2010 Residential Water Heater Replacement Check List

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

Transcription:

TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com MODEL FAI4 FRESH AIR INTAKE KIT INCLUDES DBM4 BOOSTER FAN AND 4 INTAKE HOOD INSTALLATION INSTRUCTIONS OWNER'S INSTRUCTIONS, DO NOT DESTROY THIS DEVICE MUST BE INSTALLED BY A QUALIFIED PERSON. READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND OPERATION OF THE FAI4. Copyright 2011, Tjernlund Products, Inc. All rights reserved. P/N 8504187

TABLE OF CONTENTS Descriptions and Specifications...1 Installation Restrictions...1 Cautions...1 Optional Controls & Recommended Methods of Operation...1-2 Intake Hood Location and FAI4 Installation...3 Installation...3-4 Maintenance...4 How to Obtain Service & Warranty...5 Replacement Parts & Accessories...5 FAI4 Intake Hood Template...6 IN-FORCER TM is a trademark of Tjernlund Products, Inc. Tjernlund Products welcomes your comments and questions. Call us at (651) 426-2993, (800) 255-4208, Fax (651) 426-9547, email us at fanmail@tjfans.com or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN 55110-6794. DESCRIPTION The IN-FORCER TM FAI4 Powered Air Intake kit includes a DBM4 Booster Fan and 4 Intake Hood. It provides a simple and economical way to provide fresh, outside air to dilute trapped pollutants and replace air vented by exhaust fans and fuel burning equipment. Plug into a switched outlet, use a remote on/off switch or a plug-in timer to operate on a desired schedule. Standard 4 flex or metal duct may be used for ducting. The efficient 75 CFM fan consumes only 18 watts. FAI4 INTAKE KIT SPECIFICATIONS Intake Hood Diameter 4 DBM4 Inlet/Outlet Diameter 4 MODEL MOTOR SPECIFICATIONS O FEET CFM DUCT LENGTH IN FEET 10 FEET CFM 20 FEET CFM FAI4* 120 VOLT 18 WATTS.20 AMPS 75 62 50 *The FAI4 is a model DBM4 Booster Fan with a 4 Intake Hood. Performance is based on using the DBM4 Booster Fan with the FAI4 Intake Hood. GENERAL INFORMATION Each FAI4 is electrically factory line tested before shipment. After opening carton, Inspect thoroughly for hidden damage. INSTALLATION RESTRICTIONS WARNING: Improper installation, adjustment, alterations, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the equipment supplier. Observe proper location of hood as described on page 3. The FAI4 must only be installed with the hood on an exterior wall. CAUTIONS WARNING: Failure to install, maintain and/or operate the FAI4 in accordance with manufacturer s instructions may result in conditions that can produce bodily injury and property damage. Disconnect power supply to fan and/or controls when servicing the FAI4. Failure to do so may result in personal injury and/or equipment damage. Make certain the power source is adequate for the FAI4 requirements. Do not add the FAI4 to a circuit where the total electrical load is unknown. A minimum 2 foot section of pipe is necessary on discharge side to prevent injury from fingers or objects placed in operating fan. OPTIONAL CONTROL METHODS STANDARD PLUG-IN TIMER OPERATION A standard plug-in timer can be utilized for to cycle the FAI4 at desired times or periods. TJERNLUND OPTIONAL DH2P DEHUMIDISTAT CONTROL OPERATION Tjernlund s optional DH2P dehumidistat control can be used to operate the FAI4 based on humidity levels. The DH2P features on/off settings or 20% - 80% Relative Humidity operating range TJERNLUND OPTIONAL SCP SPEED CONTROL OPERATION Tjernlund s optional SCP speed control can be used to vary the speed the FAI4. Plug SCP speed control into standard outlet and plug FAI4 into SCP speed control. 1

RECOMMENDED PATTERNS OF OPERATION A standard plug-in timer can be programmed based on the lifestyle or needs of the occupants. For example, a family with smokers may want to cycle the FAI4 more frequently than a family of non-smokers. Another timed method may be to cycle the FAI4 during peak usage of exhaust fans, such as bathroom, kitchen, laundry or utility. Outdoor air should be brought in at these peak times to help balance out pressure inside the house. The FAI4 can be cycled on and off at regular intervals to periodically provide fresh air to the home. It can also be ran like an economizer to bring outside air in during evening time when it is cooler outside. If using the optional DH2P dehumidistat control, the FAI4 can automatically cycle based on the relative humidity level of the house or it can be operated based on recommendations below. It is generally recommended to maintain a Relative Humidity (RH) below 60% to inhibit mold growth. HYPOTHETICAL OPERATION BASED ON LIFESTYLE The example below shows a possible way in which cycling times of the FAI4 may be determined based on household occupant lifestyles. 6:00 A.M. to 9:00 A.M. = Outside fresh air should be brought into the house to compensate for morning routines. Bathing, cooking, laundry and other activities such as smoking necessitate that outside fresh air to be brought in. Depressurization of the house at these times is common with many exhaust fans running at one time. 9:00 A.M. to 4:00 P.M. = House is normally vacant with occupants at work or school. Cycle FAI4 on and off for 15 minute intervals per hour to assure fresh air is supplied to the house. 4:00 P.M. to 8:00 P.M. = Outside fresh air should be brought into the house to compensate for evening routines. Bathing, cooking, laundry and other activities such as smoking necessitate that outside fresh air to be brought in. Depressurization of the house at these times is common with many exhaust fans running at one time. 8:00 P.M. to 6:00 A.M. = All members of the household are usually present. Outside fresh air is needed to dilute occupant generated carbon dioxide during sleeping. Cycle FAI4 on and off for 15 minute intervals, with occasional 30 minute intervals to assure fresh air is supplied to house. FAI4 OPERATION BASED ON AIR CHANGES PER HOUR This method of operation can be used to supplement or provide for guaranteed air change rates. Table 1 shows the constant Cubic Feet Per Minute (CFM) of air necessary to produce the desired Air Change Per Hour rate (ACH), assuming natural infiltration of outside air at a rate of.10 ACH. Square footage is determined by calculating the finished living space of the house. Garages and crawl space should not be included. The constant CFM figures shown assume that the living space has standard 8 foot ceilings. 1. Determine square footage of house living space on left hand column. 2. Pick desired air change rate from top row. 3. Locate intersection of these points to determine constant CFM that should be obtained to meet desired ACH. The FAI4 will provide up to 75 CFM. Where the CFM delivery of the FAI4 exceeds that listed in Table 1, a standard plug-in timer can be set so the FAI4 is cycled to obtain the desired ACH or Tjernlund s optional SCP speed control may be used. EXAMPLE 2500 square feet of living space.2 ACH desired ventilation rate equals 33 CFM FAI4 capacity of 75 CFM In this example a plug-in timer may be set so that the FAI4 operates for one half hour straight each hour or two fifteen minute periods. TABLE 1 2

RECOMMENDED INSTALLATION LOCATION The FAI4 may be mounted anywhere in the house. The most common place to mount the Intake Hood is in the basement through the rim joist on top of the foundation wall. It is required that the FAI4 be installed in a location where it will not be directed at the occupants. Do not discharge intake air onto water pipes or other equipment which may be affected by temperature extremes. Do not terminate adjacent to thermostat. Outside temperatures can disrupt normal thermostat operation. Do not terminate within three feet from a barometric draft control or intake grille of a heating appliance. WARNING: Do not exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed combustion. Carbon monoxide poisoning may result. INTAKE HOOD TERMINATION CLEARANCES Install Intake Hood in accordance with BOCA national Mechanical Codes M-306.1 and M-306.1.1 as follows, (See Diagram A). M-306.1 LOCATION: Outside air exhaust and intake openings shall be located a minimum of 10 feet (3048mm) from lot lines or buildings on the same lot. When openings front on a street or public way, the distance shall be measured to the centerline of the street or public way. M-306.1.1 INTAKE OPENINGS: Outside air intake openings shall be located a minimum of 10 feet (3048mm) from any hazard or noxious contaminant such as vents, chimneys, plumbing vents, streets, alleys, parking lots and loading docks. When a source contaminant is located within 10 feet (3048mm) of an intake opening, such opening shall be located a minimum of 2 feet (610mm) below the contaminant source. IN ADDITION TO THESE CODES THE MANUFACTURER RECOMMENDS THAT: The Intake Hood should be a minimum of 1 foot above grade or anticipated snow line. DIAGRAM A INSTALLATION (TOOLS REQUIRED) Reciprocating saw Drill and 1/2, 3/16 bits, 1/4 nut driver Siding tools (dependent on exterior finish) Level INSTALLATION OF INTAKE HOOD IMPORTANT: Before cutting opening through wall, confirm FAI4 hood termination clearances are met as noted above. If installing the Intake Hood through a wall thicker than 8, it will be necessary to add a piece of rigid pipe to extend through wall. CAUTION: When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities. 1. Remove Intake Hood Hole Template from page 6 and attach template to interior rim joist or wall intake hood will penetrate. 2. Using 1/2 bit, drill pilot holes noted on template from inside through rim joist, wall board, siding, etc., keeping drill bit perpendicular to the wall. 1/2 bit must be long enough to penetrate through exterior. 3

3. Remove template from interior wall and attach to building exterior, aligning pilot holes made in step 2. 4. Using a reciprocating saw and appropriate blade, cut opening following the template outline for Intake Hood, (See Diagram B). 5. Knock out material exposing hole through the wall. 6. Drill (4) 3/16 holes through Intake Hood 1 in from sides on top and bottom lip. If mounting on masonry wall, insert Intake Hood through wall to mark & drill (4) 3/16 wall anchor holes. Apply exterior rated caulk to back of Intake Hood and fasten to wall as shown. Apply a bead of exterior rated caulk around Intake Hood flange and exterior of building, (See Diagram C). DIAGRAM B DIAGRAM C SAWCUT 1/2" ALIGNMENT HOLES RECIPROCATING SAW TRACE PATTERN OR TAPE TO WALL INSTALLATION OF FAI4 FAN Properly support FAI4 fan with plumber s strap and attach rigid or flex duct as shown in diagrams below. Mounting with Perforated Strap Connection with Rigid Duct Connection with Flex Duct T Encircle with Perforated Plumber s Strap and Secure Tightly Use Sheet Metal Screws (1 Max) and Over-Wrap with Duct Tape INSTALLATION OF FLEX OR RIGID DUCT Use Nylon Ties or Sheet Metal Screws and Over-Wrap with Duct Tape CAUTION: A minimum 2 foot section of pipe is necessary on discharge side to prevent injury from fingers or objects placed in operating fan. Plan duct runs with desired CFM requirements in mind, see performance chart on page 1. Standard 4 metal or flex duct is acceptable for intake and supply runs. If using flex duct, make sure adherence to manufacturer s restrictions is followed. All flex duct runs should be tapered gradually to prevent severe bends and kinks that may add resistance and reduce CFM. Make bends with as large a radius as possible and keep flex duct as straight as possible for extended runs. In cold climates, insulated flex or insulating metal duct is recommended. Each 90 degree elbow of 4 metal duct is equal to 6 feet of straight pipe, each 45 degree elbow is equal to 3 feet of straight pipe. The discharge should terminate three feet from a barometric draft control or intake grille of an appliance. If this is not possible terminate on sides or opposite side of intake on appliance. Never terminate within 3 feet from the front or intake side of appliance. Supply duct should also terminate a minimum of 18 inches above floor or other obstructions if perpendicular to them. MAINTENANCE The FAI4 Intake Hood screen must be inspected every 3 to 6 months. Remove any foreign material such as leaves, lint, cottonwood or other items. 4

HOW HOW TO OBTAIN SERVICE ASSISTANCE 1. If you have any questions about the FAI4 or if it requires adjustment, repair or routine maintenance, we suggest that you contact your installer, contractor or service agency. 2. If you require technical information contact Tjernlund Products, Inc. at 1-800-255-4208 or email us at fanmail@tjfans.com. When contacting Tjernlund Products, Inc., please have the following information available: 1. Model number and date code 2. Name and address of installer and service agency 3. Date of original installation and dates any service work was performed 4. Details of the problem LIMITED PARTS WARRANTY AND CLAIM PROCEDURE Tjernlund Products, Inc. warrants the components of the FAI4 for one year from date of installation. This warranty covers defects in material and workmanship. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. This warranty DOES NOT cover the complete FAI4 if it is operative, except for the defective part. Tjernlund Products, Inc. will issue credit or provide a free part to replace one that becomes defective during the one year warranty period. All receipts should include the date code of the FAI4 to ensure that the defective component corresponds with the complete unit. This will help prevent possible credit refusal. 1.) If unable to determine faulty component, contact your Tjernlund distributor, Tjernlund Products Technical Customer Service Department at 1-800-255-4208 for troubleshooting assistance or email us at fanmail@tjfans.com. 2.) After the faulty component is determined, return it to your Tjernlund distributor for replacement. Please include FAI4 date code component was taken from. Credit or replacement will only be issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund. WHAT IS NOT COVERED Product installed contrary to our installation instructions Product that has been altered, neglected or misused Any freight charges related to the return of the defective part Any labor charges related to evaluating and replacing the defective part FAI4 PARTS AND ACCESSORIES REPLACEMENT PARTS FAI4 Fan Assembly ACCESSORIES Plug-In Speed Control DH2P Dehumidistat Control MODEL DBM4 MODEL SCP DH2P TJERNLUND LIMITED 1 YEAR WARRANTY Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WAR- RANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED WAR- RANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. Send all inquiries regarding warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 (800) 255-4208 Fax (651) 426-9547 Email fanmail@tjfans.com. 5

INTAKE HOOD HOLE TEMPLATE (For proper use of this template, see FAI4 installation instructions.) 4 1/2" DIA. (Cut on dotted line to remove template.) 1/2" PILOT HOLES: DRILL FROM INSIDE OF STRUCTURE. USE TEMPLATE FOR EXTERIOR ALIGNMENT. POSITION TEMPLATE ON RIM JOIST OR THE WALL INTAKE HOOD WILL PENETRATE, TAKING INTO CONSIDERATION THE SPACE NEEDED TO DRILL PILOT HOLES. 6