Rapid and safe. DAC UNIVERSAL CLEANS, LUBRICATES AND STERILIZES INTERNALLY ROTATING INSTRUMENTS



Similar documents
We make a point of ensuring safety.

MELA quick 12+ Compact. Fast. Strong.

A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series

Just one click gives you more class.

ETD3 the new standard in endoscope reprocessing.

Systematic X-ray diagnostics as flexible and individual as your dental practice.

Totally lightweight, totally flexible, totally titanium.

STATIM G4 Cassette Autoclaves From start to dry in the blink of an eye.

AUTOCLAVE STEAM STERILIZERS

LABOKLAV. Autoclaves Made in Germany.

one claim: only the best into your hands.

Clinic Washer-Disinfectors. Washer-Disinfector Line

Totally lightweight, totally flexible, totally titanium.

clean and quiet dental

Material test chamber with mechanical convection

SunMaxx Solar Filling Station Operating Instructions

OT 40L / 90L. Laboratory Steam Sterilizers

The professional for your diagnostics.

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min.

Sterilizers with extra class

93052/1115-V05. C260 User Manual

C4 + Compact design newly defined.

We make a point of ensuring safety.

Tabletop Line. Automatic and Semi-Automatic Autoclave Series

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Cliniklav 25. For highest quality in surgical applications MELAG. Evidence Based Sterilization

THREE CLASSES, ONE CLAIM: ONLY THE BEST INTO YOUR HANDS.

Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/ Ø90x160mm W200xH385xD (Net:28)

Hydraulic Control Solutions

T1 LINE. Handpieces. T1 LINE supreme ergonomics in titanium.

The Premium-Plus-Class Now even better

Systematic X-ray diagnostics as flexible and individual as your dental practice. XIOS PLUS the intraoral sensor system

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

FVA/A1 saturated-steam sterilizer

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

FTDI VCP DRIVER (free) (WIN/MAC/LINUX)

Integra Padgett. Dermatomes. Limit uncertainty with quality and power from the brand you trust

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

INTEGO. PERFORMANCE YOU CAN RELY ON.

Heating oven with mechanical convection

Laboratory Autoclave SN210/310/510,SQ510/810

Heating oven with mechanical control

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Laserlyte-Flex Alignment System

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Vacuum drying oven for non-flammable solvents

Infection Control in the Dental Practice through Proper Sterilization

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Infrarot-Bewegungsmelder IP44

Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.

Featuring fast rotor exchanges with AUTO-LOCK

Installation, operation and maintenance manual TX 35A

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Design ideas for dental practices. With Sirona.

book Seite 1 Freitag, 22. Juni : qn=ifkb=l=qo=ifkb. Operating Instructions. båöäáëü. lééê~íáåö=áåëíêìåíáçåë

FilterFlow Automatic Water Boilers. Pure Quality

Description of functions

804 Ti Stand. Manual EN

Desiccant Air Dryers Heatless, Heated and Heated Blower

qn=ifkb=l=qo=ifkb=l=qp=ifkb

Digital panoramic X-ray for practical diagnostics

TUTTNAUER OLD AUTOCLAVE OPERATING PROCEDURE

CAR SEAT/ STROLLER INSTRUCTION MANUAL

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION

Vacuum Hair Clipper. 10,000 prize draw. Register online for HC6550. EXTRA year guarantee FREE rewards gallery

Assembly Instructions

Installation Instructions

Incubator with mechanical convection

Select Radiators Installation Guide

Automatic Back-Flushing Filter AutoFilt RF9.

Manual for GlobePharma Mini-Press II Rotary Tablet Press

The power of innovation. For better media preparation. Media preparators Systec MediaPrep.

Please read and keep these instructions. Run water through your machine before first use

Instructions Manual AmazonBasics 12-Sheet Cross-Cut Paper / CD / Credit Card Shredder with Basket ASIN# B005QAQFFS. Customer Service

Handpieces. Ready for takeoff! The high-speed handpiece family T1, T2, T3

Wireless 7 Day Programmable Room Thermostat

MH 3M & 4M. High pressure washers with hot benefits

UNITOR VACUUM cleaners

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ACCESSORIES OXYGEN-THERAPY

INSTALLATION INSTRUCTIONS

Seeing CAD/CAM in a new light.

GETINGE CLEAN MANAGEMENT SYSTEM

AUTOCLAVES. Table Top. STE-TEN, 1 Liter Autoclave

TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150

Laddomat Charging unit

Instruction manual for Firstline FCS12000CH

HEAVY DUTY SEVERING AND BEVELLING MACHINE TNO FAB-SERIES

Installation Guide 2010 BMW S1000RR Full Exhaust System

Transcription:

CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS DAC UNIVERSAL CLEANS, LUBRICATES AND STERILIZES INTERNALLY ROTATING INSTRUMENTS Rapid and safe. T h e D e n t a l C o m p a n y

SIRONA DAC UNIVERSAL Cleaner handpieces and turbines. Get cleaner handpieces and turbines with the DAC UNIVERSAL combination autoclave and save time in the clinic. Cleaning instruments before sterilizing them is essential for successful sterilization. The DAC UNIVERSAL is able to clean the internal channels of the handpieces, contra angles and turbines. During the external wash the instruments are washed twice with cold water (pulse wash) and once with hot water. This process removes biofilm and dirt faster and more effectively. It is normally very diffi cult to clean the channels manually. The DAC UNIVERSAL is able to thoroughly clean the instruments both internally and externally, thereby ensuring that they are optimally prepared for sterilization. Tests have shown that the number of repairs to handpieces, contra angles and turbines is reduced as a result of the fact that dirt is removed from the internal channels in the instruments and thanks to the extremely thorough and consistent maintenance of the instruments. This extends the lifetime of the handpieces, contra angles and turbines. The absence of dirt in the internal channels reduces the amount of repair work resulting from damage caused by dirt inside the instruments. Enjoy every day. With Sirona. 02 03

BACK IN ACTION QUICKLY Cleans, lubricates and sterilizes in approx. 12 minutes. HYGIENIC AND EFFICIENT A minimum of effort giving maximum timesaving. Save time in the clinic Using the DAC UNIVERSAL reduces the time spent cleaning and lubricating the handpieces, contra angles and turbines manually. Moreover, as the DAC UNIVERSAL is a highly efficient autoclave that ensures a fast process, thereby reducing the time spent on cleaning, maintenance and sterilization procedures in the clinic. Lubrication Lubrication is fully automatic using the amount of oil recommended by the manufacturer. When the accessory basket for small dental instruments is used, the oiling process can be manually deactivated. Sterilization The DAC UNIVERSAL has four sterilization processes which the user can choose between. The four programmes are: 134 C, 3-minute sterilization 134 C, 18-minute sterilization 121 C, 15-minute sterilization 134 ºC, wrapped sterilization The basic principle behind each sterilization process in the DAC UNIVERSAL autoclave is the use of a back-flush mechanism. The backflush ensures that the saturated steam is forced through the instruments, thereby sterilizing the internal channels as well as the external parts of the handpieces and turbines. Instead of countless single manual cleaning, expensive lubrication and time-consuming sterilization, simply load your instruments into the combination-autoclave and take them out cleaned, lubricated and sterilized. In comparison to the conventional handling of the instruments, the DAC Universal is clearly more effective and extremely DAC UNIVERSAL time-saving. But not only the total time consumption for hygiene care and maintenance of your instruments is lowered. As cleaning, lubrication and sterilizing is fully automated, the team at the clinic will also be able to concentrate on other tasks. Mounting: 30 sec. Cleaning/Lubricating/Sterilizing: 12 min. Ready: 12:30 min. We recommend that instruments intended for storage or surgery are wrapped and resterilized. Manual Handling 1 2 3 4 6 Instruments are cleaned, lubricated and sterilized 1 0:00 0:30 Lid closes. 4 0:30 1:20 Leak test. 1:20 2:15 Internal cold cleaning. 2 3 2:15 2:30 Lubrication. 2:30 5:00 External cold cleaning. 5:00 5:30 External hot cleaning. 5:30 6:25 Heating procedure to 134 C. 6:25 7:35 Back-Flush. The steam is forced through the open instruments via the valves. 7:35 10:35 Sterilization. 10:35 11:10 Back-Flush. The steam is forced through the open instruments via the valves. 11:10 11:35 Drying. 11:35 11:50 Lid opens a little bit. 11:50 12:00 Lid opens after pressing C. Cleaning: 3 min. Lubricating: 3 min. Sterilizing: 18 50 min. Ready: 24 56 min. 04 05

PROPER HYGIENE FOR ALL TYPES OF INSTRUMENTS The extraordinary is our standard. STERILIZE SAFELY Unique design, quality and versatility. The versatility of the DAC UNIVERSAL ensures that you will have both wrapped, unwrapped and solid instruments back in action quickly. Unwrapped instruments The three standard programs of the DAC UNIVERSAL provide you with up to six thoroughly cleaned, lubricated and sterilized hand pieces or turbines in a record time. These instruments are then ready for immediate use. Wrapped instruments With the DAC UNIVERSAL you can also sterilize wrapped instruments. Up to three wrapped instruments will be sterilized in a quick cycle which should be run after and in addition to one of the DAC UNIVERSAL standard programs. This wrapped cycle will enable you to have your wrapped instruments sterilized and back in action very quickly. The wrapped instruments can also be used for surgery or stored for later use. Solid instruments With the additional basket for the DAC UNIVERSAL solid instruments are cleaned and sterilized quickly without any manual handling. This eliminates the risk of human errors and protects the clinic staff from possible injuries from cuts, etc. Unique design and quality are essential for the production which is certified according to the ISO 9001:2000 and ISO 13485:2003 standards by Lloyd s Register Quality Assurance. The HygCen Centrum GmbH has tested the performance of the DAC UNIVERSAL combin ation autoclave according to the European standard EN 13060 as a class S type certificated for sterilization of handpieces and contra angles. The DAC UNIVERSAL carries the CE mark. The DAC UNIVERSAL is a low-noise autoclave. Safety User safety is a primary concern for Sirona Dental Systems. The DAC UNIVERSAL combination autoclave features a safety ring that prevents the user s fingers from being caught between the chamber and the lid. In addition, it must be stressed that the lubrication process is carried out in a closed system. This prevents the release of oil fumes into the clinic during the lubrication process. A built-in water conductivity sensor measures the water quality and activates an alarm if the water quality in the tank deteriorates. Servicing the DAC UNIVERSAL combination autoclave is extremely straightforward, making it eas ier, faster and cheaper to service the machine. Reports It is possible to connect a printer or data logger (accessories) to the DAC UNIVERSAL. Connecting either of these to the DAC UNIVERSAL will produce a transcript of the latest sterilization cycle. The information from this transcript includes time, temperature, pressure and the serial number of the DAC UNIVERSAL, and a conclusion on the sterilization cycle whether it was successful or unsuccessful. Specifications Voltage Power consumption Water quality Water tank capacity Oil tank capacity Height open Height closed Width Depth Installation DAC UNIVERSAL The DAC UNIVERSAL is a multiple-voltage machine, which means that it can operate at any voltage level between 90 240 V, 50/60 Hz 1.1 kw Demineralised or distilled water (< 3 µs) 2.0 l 0.2 l 60 cm 35 cm 36 cm 37 cm The following installations are necessary: Pressurized air (there is a pressure regulator built into the machine) The instruments are lubricated in a closed system which prevents the release of oil fumes into the clinic during the lubrication process. 06 07

PERSONAL EXPERIENCES DAC UNIVERSAL recommended around the world. WATER TREATMENT SYSTEM NITRADEM DIRECT CONNECT Aabyhoej, Denmark Dentist Ole Steffensen The DAC is an extremely effective autoclave, which can handle the complete process for turbines and contra angles between each patient due to the short cycle time. Madrid, Spain Dentist Fernando Luengo Since we bought the DAC in April of 2004 we have experienced a much longer lifespan of our instruments, which has led to great money saving in repairs. Furthermore the DAC has saved us time with the all in one procedure and we find it one of the best acquisitions made. Direct Connection NitraDem Direct Connect provides high quality demineralised water directly to your DAC UNIVERSAL and any other autoclave. This highly efficient water treatment system is fully automated and furthermore conforms to the European Norm EN1717, which allows the direct connection between water system and autoclave. The capacity of the NitraDem Direct Connect is so large that it can supply up to three autoclaves at the same time. NitraDem Direct Connect also gives you the possibility to tap demineralised water if needed. Easy handling With the NitraDem Direct Connect you no longer have to worry about the handling of heavy water bottles. Moreover, the extremely easy handling of the water treatment system means that you can focus on other important tasks in the busy day-to-day activities in the clinic. The NitraDem Filter demineralises water using an ion exchange system and the filter itself is very easy and quick to change. Passau, Germany Dr. med. dent. Rolf Linseisen The DAC Universal plays a fundamental part in securing optimal hygiene procedures in our modern clinic and at the same time it ensures total process safety. Guernsey, Great Britain Dentist Gareth Wallis We bought a DAC Universal in August 2005 and instantly felt that it is very easy to use. We especially appreciate that the assistants now have more time left to help the dentists and for other tasks. Constant monitoring To ensure the best working conditions for your DAC UNIVERSAL and other autoclaves, NitraDem Direct Connect constantly monitors the quality of the demineralised water. This constant flow of demineralised water with a minimum microsiemens level prolongs the lifespan of your autoclaves and lowers their repair costs. Béziers, France Dentist Dr. Christian Bodart The saving of time enables us to release the assistant for other tasks helping at the chair or administrative tasks. My associate and I, we are sure that we have made the best choice for our dental office. Greenhills, Australia Pacific Smiles Dental Pacific Smiles Dental believes that the implementation of the DAC has been a positive addition to our existing high standards of infection control. The DAC is an exceptionally efficient and user-friendly device. The staff of Pacific Smiles Dental Greenhills now wonders how they ever survived without the DAC! Control Panel: REF 6259068 Hamburg, Germany Dr. med. dent. Axel Posorski Now we are not only saving time by having a machine, which can handle all three processes in one, we also get a better result and more time with the patients. Brescia, Italy Dottori Bazzoli, Mainetti e Treccani Not only have the employees benefited from the DAC Universal but also the patients, as the assistants have got more time for the patients at their disposal. Water pistol: REF 6259084 Installations kit: REF 6259076 NitraDem filter: REF 6198431 08 09

REF 6051739 Extra lid without adapters REF 6259109 Holder for Lid REF 6126200 Complete basket For cleaning and sterilization of solid products. REF 6196377 Replacement basket REF 6123827 Basket for small parts REF 6078583 Filter, 6 pcs. REF 6053842 Cleaning tabs, 100 pcs. REF 5892059 Chemical indicators, 100 pcs. REF 6051820 Spore tester To be used for validating the DAC UNIVERSAL combination autoclave. Place the biological or chemical indicator inside the tester. Close the spore-tester and place it on the E-type click adapter for handpieces (REF 6051648). REF 6051788 Holder for indicator To be used for validating the DAC UNIVERSAL autoclave. Place the biological indicator and/ or the chemical indicator in the clip and place the clip on the lid. REF 6051770 Printer Printer for the DAC UNIVERSAL. REF 6051705 Sirona TE adapter Handpiece adapter for TE & T1 classic instruments. To load: Gently click the handpiece onto the adapter without the use of force. To unload: Pull the handpiece off REF 6051648 Intramatic adapter E-type adapter for handpieces. To load: Click the handpiece onto To unload: Push the small button on the adapter and remove the instrument. REF 6051663 Adapter for Kavo handpiece heads To load: Place the Kavo head in the adapter hole and press down. To unload: Pull the Kavo head off REF 6259092 Lid & Steril-Filter for wrapped instruments For wrapped instruments from serial number 104000. REF 6051697 Sirona turbine adapter To load: Click the turbine onto REF 6051655 Kavo turbine adapter REF 6051671 W&H turbine adapter To load: Click the turbine onto REF 6051689 W&H turbine adapter For TA-98LW/96LW high-speed instruments only! REF 6051713 Bien Air turbine adapter To unload: Push the small button on the adapter and remove the instrument. REF 6051762 Castellini turbine adapter To load: Click the turbine onto REF 6051804 NSK Phateleus adapter To load: Click the instrument onto To unload: Pull off the instrument. REF 6051812 NSK Pana QD adapter To load: Click the turbine onto REF 6086628 NITRAM OIL 200 ml (white), 6 pcs. Lubrication for use in the DAC UNIVERSAL with serial No. <103 999 REF 6259118 NITRAM OIL #2 200 ml (blue), 6 pcs. Lubrication for use in the DAC UNI- VERSAL with serial No. 104 000 REF 6051846 Midwest adapter for quick connect (4, 5, 6 holes) To load: Align the instrument to fit the holes and press down. To unload: Press the ring and pull off the instrument. REF 6051853 Midwest adapter for fixed back-end (4, 5, 6 holes) To load: Align the Midwest instrument on the adapter to fit the holes, then turn and fasten the threaded part on To unload: Turn and loosen the threaded part of the adapter and remove the instrument. REF 6051879 Midwest XGT/Stylus turbine adapter To unload: Push the small button on the adapter and remove the instrument. REF 6051887 Star swivel adapter To load: Turn the basic plate of the adapter to the right and click the turbine onto To unload: Turn the basic plate of the adapter to the right and pull the turbine off REF 6051895 Adapter for Star attachment To load/unload: Place/remove the coupling the same way that the coupling is normally placed/ removed on the Star motor. REF 6051911 Adapter for Morita turbines (PAR-DI) To attach: snap the turbine into To detach: Press the small button on the adapter and detach the instrument. REF 6051929 Morita (PAR-O) turbine adapter To load: press the turbine onto To unload: Push the small button on the adapter and remove the instrument. REF 6051937 Adapter for Yoshida turbines To attach: Press the button and snap the turbine into To detach: Press the button on the adapter and detach the turbine. REF 6085745 OSADA OFJ-MZL To attach: Snap the turbine into To detach: Press the bottom plate on the adapter and detach the turbine. 10 11

CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS SIRONA UNIQUE WORLDWIDE SYSTEMS EXPERTISE IN DENTAL EQUIPMENT PRODUCTS Sirona develops and manufactures a comprehensive range of dental equipment, including CAD/CAM Systems for dental practices (CEREC) and laboratories (inlab), Instruments and Hygiene Systems, Treatment Centers and Imaging Systems. Sirona manufactures high technology products that guarantee ease of use and a high return on investment for the good of your practice and for the benefit of your patients. In this way, you can approach every challenge you face with confidence. Enjoy every day. With Sirona. Subject to technical changes and errors in the text, Order No. A91100-M45-A851-01-7600, Printed in Germany, Dispo No. 04603, 4023/14058 WS 03092.V2 Sirona Dental Systems E-mail: contact@sirona.com www.sirona.com T h e D e n t a l C o m p a n y