CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)



Similar documents
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Ordering Part Numbers:

4 Posiflow Proportional Solenoid Valves

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Duct Humidity Transmitter

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Givare NC-SRS 280 och 880

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

mpm DIN CONNECTORS

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Contents. Document information

Cable Plug acc. to DIN EN , Form A

Navigate the Catalog HYDRA FORCE. Solenoid Valves. About HydraForce. System Manifolds. How to Contact Us. Electro-Proportional Valves

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

Mounting Instructions. Torque Transducer. A en

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Analog Servo Drive 25A8

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Model 201 Wiegand Touchpad Reader Installation Guide

Digital input modules

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Redundancy Module QUINT-DIODE/40

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

PTU Series Ultrahigh-Purity Pressure Transducers

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Power Supplies 3. SDN-P DIN Rail Series

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Cross-beam scanning system to detect slim objects. 100 mm in

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Operating Manual UWAPS-TINY Series

SX460. Generator Automatic Voltage Regulator Operation Manual

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Digital inductive conductivity transmitter

VSO MAX HP High Flow Proportional Valve

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

MCR1900 Media Converter 19-Slot Chassis

Automatic Voltage Regulator User s Manual

MINI MCR-SL-R-UI(-SP)

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Centro-Matic Automatic Lubrication Systems System Controls

Model EC5111 Speed Controller Isochronous / Droop

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet


Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

HERZ-Thermal Actuators

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

289 SERIES FLOW METER TRANSMITTERS

Pressure transmitter For general industrial applications Model A-10

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

ELECTRONIC CONTROL UNITS. Machine Management Systems. Description. EC-MMS-1012-H 10 inputs, 12 outputs meter-in systems controller 20

Adjustment functions for both span and shift have been incorporated

Type: DILM32 10(24V50HZ) Article No.:

400 Series - Mini USB Buccaneer

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Single Phase Soft Starter

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Description. Dimensions. Features. precision works better

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Addendum to the Operating Instructions

ADM1TE 5/30A DIN rail single phase two wire energy meter

AutoRanging Digital MultiMeter

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

OPERATION MANUAL VALVE CHECKER G

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

LIEBERT VNSA Installation Sheet

ST Series POWER SUPPLIES USER INSTRUCTIONS

User Manual. CFG253 3 MHz Function Generator

Three-phase monitoring relay CM-PFE

RM4TG20 three-phase network control relay RM4-T - range V

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Transcription:

TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output (2A, 1.2A or 600MA) y = cable length (2 meters is the standard length) Function: The connector amplifier supplies a solenoid valve with current proportional to a 4-20 ma input control signal from a programmable logic controller (PLC) or other control system. Features: Maximum current adjustment does not affect minimum current setting Adjustments accessible with a removable cover Broad range of supply voltages (9 to 28 VDC) with no degradation in performance Current sensing circuit maintains output regardless of changes in input voltage and coil resistance Modern technology utilizing high frequency switching output (PWM) Energy efficient design (no heat sink is required) Simple control with a 4-20 ma signal input Options for current output include 2 A, 1.2 A or 600 ma Mates to a DIN 43650 plug on a cartridge or block style solenoid valve Reverse polarity protection Electronic limiting circuit means no internal fuses Short circuit proof (in case of solenoid failure or miswiring) 2 m cable, unterminated Can disconnect load while connector amplifier is powered ( Hot Swap ) Application: Accurate control of hydraulic and pneumatic proportional solenoid valves used in mobile construction equipment and industrial processes. 1.0 Introduction: The User Guide for the connector amplifier describes the installation, set up adjustments and use of the unit with proportional solenoids.

1.1 Description: The 4-20 ma Connector Amplifier simplifies control of proportional solenoids by supplying a current proportional to an input control (4-20 ma). It accepts power supply voltages from 9 to 32 VDC. This linear solenoid driver utilizes high frequency switching output (PWM) to provide a DC current output. The options for maximum current output include 2 A, 1.2 A or 600 ma. A current sensing circuit maintains output current regardless of changes in input voltage and coil resistance. The user can adjust maximum and minimum current. Ramp time, dither frequency and amplitude can also be adjusted to match the application. The unit is available with a DIN 43650 connection to mount directly on the coil. Other versions are available with 0-10 V or 0-5 V (including 0-20 ma and 10K potentiometer) inputs. A remote mount version is housed in a rugged metal box. TD1102AX 2

1.2 Technical Specifications: All specifications are typical at nominal input voltage and 25 C unless otherwise specified. General Specifications Operating conditions -40 to +85 C (-40 to 185 F) Weight 0.40 lbs. (0.18 kg) Electromagnetic compatibility (EMC) Emission EN 50081-2 Immunity EN 50082-2 Approvals CE Packaging, Cable and Housing: Electrical connections Hirschmann GDME 2011 black housing (PA material, 94 V1), central screw M3 x 40, transparent cover, washer and o-ring, nitrile rubber gasket DIN 43650-A contact arrangement with 18 mm spacing (plug-style to mount on valve) Contacts: Sn, PA, 94V1 Approvals: VDE, SEV, GL (A version for remote mounting is also available.) Cable: 2 metre cable, 4 conductor, unterminated, 18 AWG For pin out, refer to Section 2.3. Manufacturer: Phoenix EDT Inc. P/N: D0518004-8 Conductors: Stranded, tin-plated copper Jacket: PVC Insulation: SR-PVC Cable Markings: UL AWM, CM, CSA AWM II A/B, CMG FT4 Protection class IP65 when correctly installed with lid, o-ring/washer and base gasket Dimensions in mm/inches (excluding cable) Length L1 85.35mm 3.36 L2 61.75mm 2.43 L3 34.00mm 1.34 Width = L3 34.00mm 1.34 Height H1 38.00mm 1.49 Electrical Specifications Operating voltage (power supply requirement) Control input signal options Input resistance Range of maximum output current 9 to 28 VDC power supply range Accepts up to a maximum of 32 VDC 4-20 ma current signal (0-10 V and 0-5 VDC/0-20 ma/10k potentiometer control input versions are also available.) 50 Ohms 2 A (1.2 A and 600 ma versions available) Solenoid resistance selection (nominal) Nominal resistance of solenoid coil should comply with: Rcoil < (Vpower supply - 1.5 V)/I-max. Note 1: For proper operation of the amplifier, match power supply voltage with rating of solenoid coil. Operating the amplifier with a supply voltage lower than the solenoid rated voltage may result in reduced maximum current output. Note 2: The coil should have no polarity or protection diodes for proper operation of the device. Note 3: The maximum current output of the amplifier should not exceed the current rating of the solenoid coil. TD1102AX 3

Adjustments Minimum current setting Maximum current setting Current ramp time Dither amplitude Current dither frequency 0 to 0.5 A (for 2 A output model) 0 to 0.3 A (for 1.2 A output model) 0 to 150 ma (for 600 ma output model) 0.6 to 2.0 A (for 2 A output model) 0.36 to 1.2 A (for 1.2 A output model) 180 to 600 ma (for 600 ma output model) 0.01-5 sec. independent 0 to 10% of rated maximum current 70 to 350 Hz (±10% of full scale) 2.0 Installation Procedures: 2.1 Precautions Against Leaks From The Environment Ensure the transparent lid is firmly in place. Ensure the brown rubber base gasket is in place, providing a seal between the proportional valve controller/amplifier and the plug on the valve. The mounting screw, compression washer and o-ring assembly should be flush with the top of the lid and fastened in place. Tighten the screw to make a firm connection to the valve with a Phillips #2 screwdriver. TD1102AX 4

2.2 Necessary Equipment Connector amplifier Cartridge or Block Proportional Solenoid Valve ready to accept a DIN 43650 plug Hydraulic power source and load circuit Power Supply (9 to 32 VDC) DC voltmeter (optional) Input: 4-20mA current signal External fusing recommended (3A) 2.3 Connection Supply voltage should be between 9 and 32 VDC. Excess voltage will damage the unit. Match the power supply voltage with the voltage rating of the solenoid coil. Operating the amplifier with a supply voltage lower than the solenoid rated voltage may result in reduced maximum current output. The maximum current output of the amplifier should not exceed the current rating of the solenoid coil. The coil should have no polarity or protection diodes for proper operation of the device. Do not install the amplifier near high voltage relays or other sources of electrical interference. Connect the power supply, input signal and valve solenoid as shown below. Set the input signal to the maximum level and confirm it is operating properly. TD1102AX 5

2.4 Wiring Connections Connect the cable conductors to the power supply and input signal as follows. For 4-20 ma Control: Turn ramp screws fully counterclockwise to eliminate ramping. Use I-Min. screw to set up minimum speed with minimum control input. Use I-Max. screw to set maximum speed with 100% of control input. Refer to page 2 (block diagram) for an alternative method of connecting a current loop transmitter to provide a current control signal input. In this method, the current loop transmitter receives power from the power supply powering the amplifier. The transmitter is connected to the amplifier s +power supply input wire and the +4 to 20mA input wire. This method does not use the 4 to 20mA input signal wire connection. 3.0 Set Up Adjustment Procedures: The location of the trim pots for the set up adjustments is shown in section 2.3. 3.1 Preparation Ensure that the connector amplifier is connected to an operating proportional valve. Use a small screwdriver to loosen the mounting screw and remove the transparent lid. The trim pots are adjusted with a slotted 1.5 screwdriver. 3.2 Interaction Between Maximum and Minimum Current Adjustments Adjusting the maximum current (I-max.) does not affect the minimum current (I-min.) setting. Adjusting the minimum current will shift the maximum current setting, as shown. TD1102AX 6

3.3 Connector Amplifier Settings The following settings represent a typical set up. I-min and I-max are multi-turn trim pots with a range of 10 turns. Ramp time, dither amplitude and frequency trim pots are single turn. Use a slotted 1.5 screwdriver. Trim Pot Adjustments Range of Adjustment Factory Setting Zero - Minimum Current Setting 0 to 0.5 A (for 2 A output model) 0% (CCW) (I-min.) 0 to 0.3 A (for 1.2 A output model) Span - Maximum Current Setting (I-max.) 0 to 150 ma (for 600 ma output model) 0.6 to 2.0 A* (for 2 A output model) 100% (CW) 0.36 to 1.2 A (for 1.2 A output model) 180 to 600 ma (for 600 ma output model) 0.01 to 5 seconds independent minimum (0.01 seconds) (CCW)** Ramp Time (Rising and Falling Edge) Dither Level (Amplitude) 0 to 10% of rated maximum current 0% (CCW) Dither Frequency 70 to 350 Hz (±10%) minimum (CCW) CW = clockwise, CCW = Counter clockwise NOTE 1: Range of maximum output current is 2A (maximum output current = min. current setting + max. current setting). **NOTE 2: To eliminate ramping, turn the trim pots fully counter clockwise. Setting the Minimum Current (I-min.) Set the minimum current before setting the maximum current. Apply minimum input (4 ma). The factory setting for the I-min. trim pot is 0 or fully counter clockwise (CCW). If the desired minimum current is greater than 0, adjust the trim pot clockwise (CW) until the desired current is achieved. The minimum current setting can be used to take into account the mechanical valve deadband and provide desired offsets from zero to allow full control within the functional range of the specific valve. Setting the Maximum Current (I-max.) Apply maximum control (20 ma). The factory setting for the I-max. trim pot is 100% or fully CW. Turn the trim pot CCW to adjust the current setting downwards to the desired maximum. The maximum current setting is adjusted to meet the customer s working pressure or flow range to the full scale signal input range. This provides maximum control for a specific application. Setting the Ramp Times The factory setting for ramp times is the minimum (0.01 seconds) or fully CCW. If the ramp time settings are not needed, leave the setting at the minimum value. To change the ramp times, adjust the trim pot CW to increase the time. Note that rising and falling ramp times are independent. TD1102AX 7

Ramp times are application dependent. They limit the rate of change or how fast the operation happens. Note that if the input signal is not applied long enough for the ramp time set, the desired solenoid current will not be reached. Setting the Dither Amplitude The factory setting for dither amplitude is 0% (CCW). To adjust dither amplitude, turn the trim pot CW until small changes in the input signal register similar changes in current output. Choose the smallest effective dither amplitude. Dither amplitude is adjustable from 0 to 10% of the rated maximum current. Dither amplitude and frequency are dependent on the specific valve. The effects of static friction on the operation of the solenoid are reduced by the application of a small AC current. The hysteresis and repeatability of the valve are improved by this practice. The optimum dither amplitude is attained when small input signal changes register similar changes in current output (pressure or flow through the valve). Setting the Dither Frequency The factory setting for dither frequency is the minimum or 0% (CCW). To adjust dither frequency, turn the trim pot CW until the desired frequency is set. Refer to the proportional valve manufacturer s catalogue for the dither frequency rating of a particular valve. 4.0 Start Up Procedures: A typical start up procedure is as follows: 1. Ensure the lid with o-ring, compression washer (next to the screw) and base gasket are correctly in place (necessary for IP65 protection). 2. Ensure that no damage or injury can occur on the machine when the valve is operated. 3. Attach the connector amplifier to the load. 4. Connect the power supply to the proportional valve controller/amplifier and apply a control signal. 5. Set I-min., I-max., ramps and dither to suit the application. Successful completion of these five steps means the connector amplifier and load are ready for normal use. TD1102AX 8

5.0 Operation: The connector amplifier ensures a hydraulic proportional valve will function in a manner directly proportional to the control input. Accurate and repeatable operation is attained. The unit performs within the mechanical limits of the proportional valve. No maintenance of the unit is required. 6.0 Ordering Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output (2A, 1.2A or 600MA) y = cable length (2 meters is the standard length) Specifications are indicative and subject to change. Actual performance will vary depending on the application and operating conditions. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process as described on www.axiomatic.com/service.html. Form: TD1102AX-06/17/11 TD1102AX 9