Compressor Service & Maintenance Manual



Similar documents
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

PC1130 Electric Air Compressor

PC1131 Electric Air Compressor

accidents which arise due to nonobservance and the safety information herein.

COMPRESSED AIR DRYER

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Medical Air Systems: Scroll

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Dryaire Desiccant System

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

CARING FOR YOUR WATER HEATER

Owners Manual 2009 PRICE LIST DRYMAXTM. Compressed Air Treatment Products. Refrigerated Air Dryers

Oil and Coolant Circulating Heating System. Model - OCSM

OPERATING & MAINTENANCE AIR COMPRESSOR RANGER 35 INSTRUCTIONS. Part No:

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Trouble Shooting. Pump

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

IMPORTANT SAFETY RULES TO FOLLOW

2 HP / 4 GALLON AIR COMPRESSOR OWNER'S MANUAL

14. Troubleshooting Guide

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

Chapter 7 Hydraulic System Troubleshooting

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Unit 24: Applications of Pneumatics and Hydraulics

Dehumidifier Users manual. For Models: DH45S DH65S

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

SERVICE PARTS INSTRUCTIONS

MP-4V Heavy Duty Riveter / 39048

Heat Pump Water Heater IOM Manual

FOXAIR 60/50 ALL MODELS

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

User Manual: C Long Point Houston, TX Facebook.com/CoolAZone Twitter.com/CoolAZone

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Portable Air Conditioner

Single Phase Soft Starter

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

TROUBLESHOOTING GUIDE

SunMaxx Solar Filling Station Operating Instructions

Panel Mounted Air Conditioners by Dantherm, Inc.

WHOLESALE DIRECT INC WEST 65TH STREET

TROUBLESHOOTING GUIDE

The MKII Controller Operator s Guide 1

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Troubleshooting Guide for Jacks Down LED Lights

Class 5 to 7 Truck and Bus Hydraulic Brake System

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

MODEL INSTALLATION INSTRUCTIONS

NAYADIC TROUBLE-SHOOTING CHECKLIST

Nitrogen Generator System Manual

Rexroth Hydraulic Pump A10VO Series User Manual

INSTANT HOT WATER RECIRCULATING SYSTEM

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N

Safety, Operation and Maintenance Manual with Parts List

12 Volt 30 Amp Digital Solar Charge Controller

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Adsorption air dryers ADS 1 215

Basic Hydraulics and Pneumatics

VOYAGER 570G. 744A Sprayer Control

Please keep these operating instructions in a safe place.

Isotemp Basic, Slim/B & Slim Square

ON-VEHICLE INSPECTION

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Nexus FS Point of Use Installation Guide

BERMAD Fire Protection

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

BERMAD Fire Protection

ACCUMULATOR INSTALLATION

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

ATLAS AIR COMPRESSOR OPERATING INSTRUCTIONS COMPRESSOR IDENTIFICATION

Geyser-R Heat pump water heater Installation manual

PAINT SPRAY GUN WASHER

Belt Driven Compressors

SELECTION, APPLICATION AND MAINTENANCE

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Thermo Top - Troubleshooting Tree

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

SILENT AIR COMPRESSOR

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

PANTHER OPERATING & MAINTENANCE INSTRUCTIONS

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

AIR COMPRESSOR. Model SET UP AND OPERATING INSTRUCTIONS. Visit our website at:

Installation & Operation

POWER TO GET THE JOB DONE

Transcription:

Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13

1

C1000 Series Service & Maintenance Manual Introduction SECTION I Compressor Service, Maintenance, and Parts Manual Section I: INTRODUCTION A. General Specifications Section II: THEORY OF OPERATION A. While Running B. Theory of Operation While Not Running Section III: MAINTENANCE A. Compressor Head Intake Filter B. Coalescing Filter C. Time Operated Purge Valve D. Tank Drain Section IV SERVICE REPAIR INSTRUCTIONS A. Troubleshooting Chart B. Electrical 1. Replacing Pressure Switch 2. Replacing Power Switch 3. Replacing Compressor Head 4. Replacing Time Operated Purge Valve C. Pneumatic 1. Replacing Check Valve 2. Replacing Differential Filter Indicator 3. Replacing Automatic Filter Float Drain 4. Replacing Desiccant Chamber Section V ILLUSTRATED PARTS BREAKDOWN A. Parts Listing B. Electrical Schematic C. Plumbing Schematic 1.800.624.2793 1

SECTION I C1000 Series Service & Maintenance Manual Introduction Introduction This manual contains the necessary information to perform all fi eld serviceable aspects of the DCI Oil-less Air Compressor line. Please take the time to read this manual and understand the proper operation and service procedures before attempting to service this machine. Our unique dryer purge system operates much differently than conventional air compressors. Understanding the proper operation and design will ensure years of dependable operation. Below is a listing of the basic tools required to properly service this equipment. Voltmeter Screwdrivers: Blade Phillips Combination Wrenches If you have any questions or need assistance in regards to any aspect ot the service and / or repair of this machine, please contact the DCI Technical Support Department at: Technical Support 1-800-624-2793 2

C1000 Series Service & Maintenance Manual Introduction SECTION I Introduction INTRODUCTION This manual contains the necessary instructions for the maintenance and/or service of the DCI air compressors. There are 3 basic confi gurations available; single and dual head available in 115V and 230V, and the triple head available in 230V. NOTE: ALL VOLTAGES +/- 5% Confi gurations 1. Single 1 horsepower compressor head on 20 gal. Horizontal tank. (See Fig. A) 2. Dual 1 horsepower compressor heads on 20 gal. Horizontal tank. (See Fig. B) 3. Dual 1 horsepower heads on 30 gal. horizontal tank. (Not Shown) Fig. A Fig. B Picture of Single Horizontal Compressor Model #C1103 & #C1203 Picture of Dual Horizontal Compressor Model # C2106 & #C2206 Picture of Triple Horizontal Compressor Model # C3210 1.800.624.2793 3

SECTION I C1000 Series Service & Maintenance Manual Introduction Model Unpacking Specifi cations MODEL SPECIFICATIONS Model CFM @ 80PSI Total HP Tank Capacity Dimensions (inches) Voltage Amps Circuit Breaker L D H C1103 3.95 1 20 34 24 29.5 115 13.4 15 C1203 3.95 1 20 34 24 29.5 230 6.7 10 C2106 7.95 2 20 34 24 29.5 115 26.8 30 C2206 7.95 2 20 34 24 29.5 230 13.4 15 C3210 11.85 3 30 46 26 36 230 21.1 30 NOTE: ALL VOLTAGES ARE +/- 5% MODEL NUMBER MAXIMUM SIMULTANEOUS USERS C1103 3 C1203 3 C2106 6 C2206 6 C3210 10 NOTE: Number of users based on 1.5cfm @ 80psi per user. Additional equipment such as air abrasion units, blow-guns, and lab equipment should be factored into the system requirements. Site Requirement Templates and additional technical information available through our Technical Service Department. 1 4

C1000 Series Service & Maintenance Manual Theory of Operation SECTION II Theory of Operation THEORY OF OPERATION While Running To start the compressor, the user shall activate the compressor head or heads with the power switches located on the front center of the machine. The selected motors will then begin to run and build pressure in the tank and piping system. A. The air is taken in through the intake fi lters, located on the rear of each compressor cylinder. The dirt and dust is fi ltered out of the intake fi lter to 5 microns in this process. B. The air is then compressed with the pistons in each cylinder, and then travels through the after-cooler (copper) tubing, which cools the air to help condense any moisture humidity taken in during the process of compression. C. The wet / dirty compressed air and condensed moisture then travel through a coalescing fi lter assembly. This fi lter allows the condensed moisture to fall to the bottom of the fi lter bowl via gravity, where it will be automatically expelled via the fl oat drain contained in the bottom of the fi lter bowl. The compressed air also travels through the coalescing fi lter element, which removes 99.998% of all particles down to 0.01 microns. A fi lter change indicator located on the top of the fi lter housing shows the condition of the element, and alerts the operator as to when the element is in need of replacement. GREEN indicates the element has more useful life, while RED indicates the element is in need of replacement. NOTE: The indicator only functions while compressed air is traveling through the fi lter with compressor running. The indicator will ALWAYS read GREEN with compressors not running. D. The compressed air then travels through the bottom of the desiccant drying chamber, where the remaining contained moisture is reduced to a pressure dewpoint of -100 F, and then travels into the main storage tank for use in the dental operatory. E. When reaching its cut-off pressure of 100psi, the pressure switch will open and the compressor motors will stop. NOTE: The time operated dryer purge valve DOES NOT open and purge when compressor stops, as it does on most competitive brands. See Theory of Operation While Not Running for more information as to the proper operation of our purge valve. 1.800.624.2793 5

SECTION II C1000 Series Service & Maintenance Manual Theory of Oporation Theory of Operation THEORY OF OPERATION While Not Running A. When the motors stop after reaching the cut-out pressure of 100psi, the user will have clean / dry air ready for use in the dental operatory. The compressor will remain in this idle state until the tank pressure drops to 80 psi, at which time the compressor motors will turn on and return the running mode of operation. B. The Time Operated dryer purge valve operates on a time basis instead of a single cycle basis used on most other types of dental air compressors. Two timers, located on the front of the valve assembly, control how often and the duration of each purge cycle. NOTE: The compressor does not purge when the compressor cycles off! C. The Left timer knob on the purge valve, controls the duration of the purge cycles. This timer is factory preset and should not be adjusted. The factory setting is at the maximum of 10 seconds. D. The Right timer knob on the purge valve controls how often the compressor purges moisture from the drying chamber. The factory setting is 7 minutes, and should NOT be adjusted. E. A TEST button is located between the two timer knobs to allow a technician to verify that the valve is operating correctly. By purging the drying chamber on a time basis, the DCI air compressors ensure the drying chamber desiccant remains dry, even during heavy usages, for consistent air quality. Aftercooling Tubing Coalescing Filter Condensate Drain Left Motor Check Valve Drying Chamber Right Motor Check Valve Flow/Check Strainer Shutoff Valve Dryer Bypass Ball Valve Drying System Pressure Gauge To Storage Tank Time Purge Valve Plumbing Schematic 1 6

C1000 Series Service & Maintenance Manual Theory of Oporation SECTION II Theory of Operation THEORY OF OPERATION While Not Running Electrical Schematic 1.800.624.2793 7

SECTION III C1000 Series Service & Maintenance Manual Maintenance Maintenance Unpacking COMPRESSOR MAINTENANCE SCHEDULE MAINTENANCE Maintenance Item Intake Filter Elements Coalescing Filter Element Time Operated Purge Valve Tank Drain A. Compressor Head Intake Filter Elements Frequency Every Six Months (semi-annually) Every 90 Days Every 60 Days Every 90 Days Dirty intake fi lter elements reduce the amount of air the compressor can take in. This reduces air output and increases the load of the motors. Every six months, remove the intake fi lter cover as shown in (Fig. D), to check for excessive dirt or discoloration. Replace with DCI Part Number 2012 if needed. The fi lters are located on the rear of each compressor cylinder. Fig. D B. Coalescing Filter Element The coalescing fi lter element should be checked with the compressor motors running. If the indicator located on the top of the fi lter housing remains GREEN, the fi lter element has additional useful life. However, if the indicator turns RED, the element should be changed. To change the element, fi rst turn off the compressor motor switches. Then turn off the Dryer bypass valve as shown in (Fig. E). With dryer bypass valve in OFF position, press the TEST button on the time operated purge valve to bleed pressure off of the drying system. Depressurization of the drying system can be confi rmed by reading the drying system pressure gauge located on top of the drying chamber. WARNING: DO NOT ATTEMPT TO SERVICE WITH SYSTEM PRESSURIZED. Unscrew the fi lter bowl by turning counter-clockwise. Lower the fi lter bowl to access the fi lter element contained inside. The fi lter element is held in place with an O-ring and internal ridges located in the bowl. Replace with DCI Part Number 2006, and reassemble the fi lter bowl. Turn the dryer bypass valve to the ON position and check compressor for proper operation by turning the power switches on. NOTE: A popping relief valve indicates a clogged coalesing element OR the Dryer Bypass valve is closed. OFF ON Fig. E 18

C1000 Series Service & Maintenance Manual Maintenance SECTION III Unpacking Maintenance MAINTENANCE C. Time Operated Purge Valve The time operated purge valve should be checked for proper operation every 60 days. To test, press the TEST button located between the two timer adjustment knobs (see Fig. F). If air escapes from the valve, it is working properly. If no air is expelled, verify that the fi lter / strainer valve is in the ON position parallel with fl oor. Check the fi lter screen inside the fi lter / strainer valve as shown in Fig. G. If the strainer / shutoff valve is on and the screen is not clogged, replace the Time Operated Purge Valve with DCI part Number 2011 for 230 volt models, or DCI Part number 2848 for 115 volt models. Fig. F Fig. G D. Tank Drain The tank drain petcock should be opened to check for moisture in the storage tank every 90 days. The tank drain is located at the bottom right hand side of the storage tank. (See Fig. H) If no moisture is present, the drying system is working properly. If moisture is present, refer to the Time Operated Purge Valve section above. Fig. H 1.800.624.2793 9

SECTION IV C1000 Series Service & Maintenance Manual Service and Repair Troubleshooting Unpacking Chart TROUBLESHOOTING CHART SYMPTOMS CAUSES POSSIBLE REMEDY Compressor Will Not Run No Power Improper Line Voltage Tripped Overload Pressure Switch System Already at Pressure Check circuit breaker. Ensure that supply voltage matches equipment ratings. Check for loose wiring. Check contact points and adjust or replace. Bleed pressure from system to ensure proper starting. Compressor Will Not Start, hums Improper Line Voltage Open Start Capacitor Open Start Winding Ensure supply voltage matches equipment ratings. Replace Start Capacitor. Replace Compressor Head. Motor Overheats Improper Voltage Ambient Temperature Too High Too Many Starts Per Hour Cycle Time Too Long Clogged Intake Filter Ensure supply voltage matches equipment ratings. Improve ventilation; add a fan. Check for air leaks and repair; add additional compressor. Check for air leaks and repair; add additional compressor. Replace intake Filter. High System Pressure Pressure Switch Improperly set or defective pressure switch. Low System Pressure Pressure Switch System Undersized Improperly set or defective pressure switch. Additional or larger compressor required. Relief Valve popping Clogged Coalescing Filter Element Dryer Bypass Valve Is Closed Faulty Relief Valve Replace coalescing fi lter element. Replace relief valve. Open Valve. 110

C1000 Series Service & Maintenance Manual Service and Repair SECTION IV Unpacking Troubleshooting Chart TROUBLESHOOTING CHART SYMPTOMS CAUSES POSSIBLE REMEDY Compressor Overheats Clogged Air Intake Filter Exhaust Valve Too Much Run Time Ambient Temperature Too High Clean or replace intake fi lter element. Clean & Replace valve-plate. Air leaks; compressor too small to meet demand. Add ventilation and \ or cooling to equipment room. Moisture In Air Lines Time Operated Purge Valve Timers Incorrectly Set Strainer Valve Off or Clogged Coalescing Filter Auto-Drain Desiccant Failure Compressor Undersized Faulty Dental Unit Diaphragm Clean or replace solenoid valve assembly. Left Timer knob duration of purge set at 10 seconds. Right Timer knob purge interval set at 7 minutes. Clean strainer and ensure valve is on. Clean or replace as needed. Replace drying chamber assembly. Additional or larger compressor to met demand requirements. Check Master shut-off and water relay diaphragms. 1.800.624.2793 11

SECTION IV C1000 Series Service & Maintenance Manual Service and Repair Unpacking Electrical ELECTRICAL A. Electrical Components 1. Pressure Switch: Turns on or off the power supplied to the individual compressor motor switches. The pressure switch is preset to run the compressors to 100psi and then open, therefore stopping the motor(s). When the system pressure drops to 80psi, the switch closes, running the compressor motors to 100psi again. To test the switch, bleed all pressure from the tank. Remove the pressure switch top cover with a 3/8 wrench. With an AC voltmeter, place the test leads on the outer terminals as shown in Fig. I. The voltage indicated should agree with the machine data plate, either 115 or 230 volt AC. If no voltage is present, check the circuit breaker. Fig. I If the proper voltage is present on the outer terminals, move the voltmeter test leads to the inner terminals of the pressure switch as shown in Fig. J. If NO voltage is present, the pressure switch is defective. If voltage is present, proceed to the next step. Turn the machine power on, and wait for compressor to reach 100psi and stop running. The 3/8 adjusting screw may be turned clockwise to increase the cutoff pressure or counter-clockwise to decrease the cutoff pressure. The maximum pressure cutoff should not exceed 100psi. If the compressor will not cut off at the desired preset pressure, or will not stop under any condition, the pressure switch is defective. Fig. J 112

C1000 Series Service & Maintenance Manual Service and Repair SECTION IV Unpacking Electrical 2. Power Switches: The toggle switches located on the front center of the compressor control the individual compressor motors. If the pressure switch is operating correctly, remove the motor terminal cover on the back of the desired compressor motor. With the power switch in the on up position, check for voltage to the compressor motor as shown in Fig. K. If the proper voltage is present, the power switch is good. If no voltage is present at the motor, replace the corresponding power switch. Fig.K 3. Compressor Motor (head): The compressor motor turns the compressor crankshaft to generate airfl ow to the system. If the correct voltage is present on the L1 and L2 terminals as described in the testing procedure listed above, but the compressor hums and does not start, the start capacitor is defective. If the correct voltage is present but nothing happens, the head is defective. To replace the motor, it is not required to cut the spade terminals from the wiring (see Figures L and M) for proper disassembly without cutting factory wiring. Fig. L Fig. M After removing the wiring from the compressor motor, the motor may be removed by unscrewing the air discharge hose on the front left cylinder, and removing the four ½ nuts securing the head to the vibration isolation mounts. 1.800.624.2793 13

SECTION IV C1000 Series Service & Maintenance Manual Service and Repair Unpacking Electrical Time Operated Purge Valve To Replace the Time Operated Purge Valve 1. Remove the Philips head screw that holds the electrical connector in place, and pull the electrical connector off of the timer assembly. 2. Turn OFF the strainer / shutoff valve in Fig. N. 3. Remove the valve and replace with DCI Part Number 2011 for 230 volt machines OR DCI Part Number 2848 for 115 volt models. 4. Return the strainer / shutoff valve to the On position. NOTE: Make sure the coil voltage matches that of the machine data tag. Fig. N 114

C1000 Series Service & Maintenance Manual Service and Repair SECTION IV Unpacking Electrical PNEUMATIC WARNING: HIGH SYSTEM PRESSURES MAY CAUSE SERIOUS INJURY. ALWAYS DEPRESSURIZE THE ENTIRE SYSTEM BEFORE ATTEMPTING TO SERVICE PNEUMATIC COMPONENTS. 1. Replacing the check valves. If a check valve failure occurs, the symptom will be air escaping through one of the compressor heads with the compressor NOT running. To replace a defective check valve, unscrew counterclockwise the air discharge hose fi tting from the appropriate compressor head. Once the air discharge hose is disconnected from the compressor head, the check valve, along with the discharge hose, may be removed from the discharge manifold by unscrewing the check valve counterclockwise, and replaced with a new check valve. Reverse this process to reassemble the check valve / discharge hose assembly. 2. Replacing the Differential Filter Indicator. If the differential indicator becomes stuck in either the red OR green indicating position, the indicator needs replacement. Replace the differential fi lter indicator by unscrewing the entire assembly counterclockwise with a 15/16-6 point / box end wrench. Install the new indicator in the reverse order. 3. Automatic Filter Float Drain. Unscrew the coalescing fi lter bowl from the fi lter head. Using a 9/16 wrench, unscrew the retaining nut on the bottom of the fi lter bowl. With the retaining nut removed, the automatic fl oat drain will be removed from the fi lter bowl. Replace in the reverse order. 4. Replacing Desiccant Chamber. To replace the desiccant chamber, remove the rigid stainless steel tubing from the dryer bypass valve at the compression fi tting, located at the dryer bypass valve. Remove the top plumbing manifold assembly from the top of the desiccant chamber, by turning counterclockwise. Remove the electrical cord from the dryer purge valve by removing the Philips head retaining screw, and pulling the cable away from the valve timer block. Next, remove the fl exible discharge hose from the discharge side of the coalescing fi lter, and then unscrew the bottom manifold assembly from the bottom of the desiccant chamber. Replace the desiccant chamber and reassemble in the reverse order. 1.800.624.2793 15

SECTION V C1000 Series Service & Maintenance Manual Illustrated Parts Breakdown Unpacking Parts Call-Out 2856 Pressure Gauge 2005 Pressure Switch 2013 Relief Valve 2012 Intake Element 2135 Check Valve 2002 1 hp Head Data Tag 2014 Drying Chamber Assembly 2856 Pressure Gauge Bypass Valve 2008 Indicator 2859 Petcock Valve 2135 Check Valve Outlet Ball Valve 2003 Coalescing Filter 2006 Coalescing Element 2007 Float Drain 2009 Strainer Shut Off 2011 Automatic Purge Valve (230 Volt) OR 2848 Automatic Puge Valve (115 Volt) 16

C1000 Series Service & Maintenance Manual Illustrated Parts Breakdown SECTION V Unpacking Electrical Schematic 1.800.624.2793 17

SECTION V C1000 Series Service & Maintenance Manual Illustrated Parts Breakdown Unpacking Plumbing Schematic Left Motor Right Motor Aftercooling Tubing Check Valve Check Valve Coalescing Filter Dryer Bypass Ball Valve Condensate Drain Drying Chamber Flow/Check Strainer Shutoff Valve Drying System Pressure Gauge To Storage Tank Time Purge Valve 118

1.800.624.2793 19

305 N. Springbrook Road Newberg, Oregon 97132 USA 503.538.8343 800.624.2793