Validation of biomedical coatings



Similar documents
Packaging Validation according to ISO 11607

Gamma Sterilisation Validation according to ISO Sterilising dose -

Metal Injection Molding (MIM) of components made of Titanium and its alloys

Outline of a quality system and standard for the certification of conformity

Sinterstation. Pro Direct Metal SLM System

Tableting Punch Performance Can Be Improved With Precision Coatings

BIOACTIVE COATINGS ON 316L STAINLESS STEEL IMPLANTS

Praxis Technology: Enhancements to Ti-MIM processing bring medical implants a step closer

Material data sheet. EOS CobaltChrome MP1. Description

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

EBM Inside. Additive Manufacturing of orthopedic implants

Duplex Stainless Steel Fabrication. Gary M. Carinci TMR Stainless Consultant for International Molybdenum Association

Brush Plating of Nickel-Tungsten Alloy for Engineering Application

Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice

Biomaterials in tissue engineering

North American Stainless

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

Powder Injection Moulding (PIM) of Dissimilar Materials and Complex Internal Features

North American Stainless

3D FUSION NANO POWDER DIRECT METAL SINTERING SYSTEMS SPECIFICATION

EUROLAB 25 years. The role of metrology and testing to characterize materials and products. EUROLAB 25th Anniversary Seminar

CVD SILICON CARBIDE. CVD SILICON CARBIDE s attributes include:

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

Espotel Test Laboratory Services. November 20, 2014

STI Surface Center Germany

Erich Lacher Präzisionsteile

Technical Data Sheet February 2014

North American Stainless

X15TN TM. A high hardness, corrosion and fatigue resistance martensitic grade CONTINUOUS INNOVATION RESEARCH SERVICE.

ReCap Product Rationale

R&D Services Knowledge transfer

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

COATED CARBIDE. TiN. Al 2 O 3

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

SECTION GUARDA SECURITY WINDOW SCREENS

VeMet, Utrecht, NL «Solution in Wear Protection» Dipl.-Ing. Wolfgang Leichnitz. Quit

SURFACE MODIFICATION OF METAL IMPLANTS WITH PLASMA SPRAYED LAYERS

Material data sheet. EOS Aluminium AlSi10Mg. Description

FATIGUE PROPERTIES OF P/M MATERIALS. Robert C. O'Brien. Hoeganaes Corporation River Road Riverton, New Jersey 08077

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

Additional requirements and conditions for abrasive products to be marked with the osa symbol

Dental Morelli Ltda.

ROLLED STAINLESS STEEL PLATES, SECTIONS AND BARS

How implant manufacturers use Additive Manufacturing to reduce production costs and increase profits

SALT SPRAY AND IMMERSION CORROSION TESTING OF PM STAINLESS STEEL MATERIALS. W. Brian James Hoeganaes Corporation. Cinnaminson, NJ 08077

Additive Manufacturing applications in Aerospace, Automotive, Robotics and beyond

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

M 2 a-magnum. Design Rationale. Large Metal Articulation. Knees Hips Extremities Cement and Accessories PMI. Technology

Brochure & Price List. May 2012

AISI O1 Cold work tool steel

Premium Tubular Solutions Super Duplex Welded Tubes for Umbilical Applications

Drainage specialist swimming pool and wellness area

Medical Device Packaging and Sterilization: What you need to know to protect your product

ADHESIVE BONDING PERFORMANCE OF GA COATED 590 MPa TENSILE STRENGTH STEELS

Material data sheet. EOS Aluminium AlSi10Mg_200C. Description

Cutting Tool Materials

EasyTrack 2 Accessories List

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

Wear-contact analysis of hip implant coated with functionally graded material

The information contained in this document is intended for healthcare professionals only.

UDDEHOLM VANADIS 30 SUPERCLEAN

BUMAX. REYHER your partner for the BUMAX range

Laser beam sintering of coatings and structures

Microwave absorbing tiles:

Materials Sciences. Dr.-Ing. Norbert Hort International Masters Programme in Biomedical Engineering

Material data sheet. EOS MaragingSteel MS1. Description

INTERTECH EDM Technology To cut PCD Materials. Presented by. Eric Ostini Product Manager +GF+ Agie Charmilles Group

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

CLICKBOND FASTENER OVERVIEW:

BRIEF PROJECT PROFILE ON WELDING ELECTRODE MANUFACTURING. Turn key project suppliers EUREKA SYSTEMS AND ELECTRODES PVT.LTD.

Grade Selection... Coated Grades / CVD... Coated Grades / PVD... Cermet... PCBN (T-CBN)... PCD (T-DIA)... Ceramics...

Process Control For Phosphate Coating A new military specification for phosphate coatings...

PRODUCT DEVELOPMENT GUIDE

Objective To conduct Charpy V-notch impact test and determine the ductile-brittle transition temperature of steels.

Information on the product

Why an Exactech Hip is Right for You

Temperature C Cure time to reach hours LSS > 1MPa minutes

Valve Steel. Valve Steel

Coating Technology: Evaporation Vs Sputtering

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

still different technique of assessment.

Application of Welding Standards in Hong Kong. S. K. Babu Laboratory Manager - Foundation Techniques Ltd

DX2202 Duplex stainless steel

Group. The precision company SURFACE TECHNOLOGIES INTERNATIONAL. Aeronautics. Surface solutions by STI Group. English

Standard Internal Hex

TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION

Alodine EC 2 The Principle of Protection

Transcription:

Synergy makes sence Validation of biomedical coatings MG-FSI72-108 Last revision: March 2011 5, Chemin du Catupolan - 69120 Vaulx en Velin - France - Tel. 33 (0)4 72 81 22 62 - Fax : 33 (0)4 72 81 22 72

MEDICAL LAB Established in 1989, MedicalGroup presently has five subsidiary companies specialising in the biomedical field: MedicalCoating, MedicalPackaging, MedicalBiomat, MedicalManufacturing and MedicalLab. All of these organisations are EN ISO 13485 certified. Medical Lab offers a comprehensive Performance Qualification service for medical devices: coating, cleaning, packaging and sterilisation validations. The purpose of these qualifications is to assure clients that their medical devices comply with European (EC) and US (FDA) regulations. THE COATINGS There are various process methods for applying coatings to implants: - Porous coating by bead sintering - Creation of a surface 3D structure composed of wire - Plasma spraying - Surface macro-roughness by spark-erosion or machining The various types of coatings resulting from these processes are: - metallic (titanium chrome cobalt) - ceramic (hydroxyapatite aluminium). The choice of couple process / coating to apply to an implant depends on the final characteristics of the desired coating.

STANDARDS AND REGULATIONS MEDICAL LAB, within the framework of its coating validation services, follows the guidelines below: Guideline FDA metallic coating: Guidance for Industry on the Testing of Metallic Plasma Sprayed Coatings on Orthopedic Implants to Support Reconsideration of Postmarket Surveillance Requirements (February 2, 2000) Guideline HAP: 510(k) Information needed for Hydroxyapatite coated orthopedic implants (February 20, 1997) Guideline FDA HA Solubility products Ksp: 510(k) Information needed for Hydroxyapatite coated orthopaedic implants ASTM A 967: Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts ASTM F1044: Standard Test Method for Shear Testing of Calcium Phosphate Coatings and Metallic Coatings. ASTM F1147: Standard Test Method for Tension Testing of Calcium Phospate and Metallic Coatings. ASTM F1160: Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate. ASTM F 1609: Standard Specification for Calcium Phosphate Coatings for Implantable Materials ASTM F1854: Standard Test Method for Stereological Evaluation of Porous Coatings on Medical Implants. ASTM F1926: Standard Test Method for Evaluation of the Environmental Stability of Calcium Phosphate Granules, Fabricated Forms, and Coatings. ASTM F 1978: Standard Test Method for Measuring Abrasion Resistance of Metallic Thermal Spray Coatings by Using the Taber Abraser. ISO 7206-4: Implants for surgery - Partial and total hip joint prostheses Part 4: Determination of endurance properties of stemmed femoral components ISO 7206-6: Implants for surgery - Partial and total hip joint prostheses Part 6: Determination of endurance properties of head and neck region of stemmed femoral components ISO 13779-2: surgical implants - Hydroxyapatite part 2 : hydroxyapatite-based coatings ISO 13779-3: Implants for surgery - Hydroxyapatite - Part 3: Chemical analysis and characterization of crystallinity and phase purity ISO 13779-4: Implants for surgery - Hydroxyapatite - Part 4: Determination of coating adhesion strength

THE VARIOUS TYPES OF TESTS 1. Mechanical tests : Static tensile strength testing Reference standard: ASTM F1147: Standard Test Method for Tension Testing of Calcium Phospate and Metallic Coatings or ISO 13779-4:2002: Surgical implants - Hydroxyapatite - Part 4: Determining the bond strength of the coating The aim of this test is to assess the tensile adhesive strength of coating layer to the substrate. Coated tests specimens 25 mm in diameter are linked to uncoated coupons with a FM1000 or 3M-2214 structural adhesive. A tensile stress is applied to separate the coating and the substrate. The maximum tensile adhesive stress is recorded. Usually, this test is performed on at least five coated coupons. 2. Mechanical tests : Static shear strength testing Reference standard: ASTM F1044: Standard Test Method for Shear Testing of Calcium Phosphate Coatings and Metallic Coatings The aim of this test is to assess the shear adhesive strength of coating layer to the substrate. Coated tests specimens 19 mm in diameter are linked to uncoated coupons with a FM1000 or 3M-2214 structural adhesive. A shear stress is applied to separate the coating and the substrate. The maximum shear adhesive stress is recorded. Usually, this test is performed on at least five coated coupons. 3. Mechanical tests : Shear Fatigue Testing Reference standard: ASTM F1160: Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate. The aim of this test is to assess the fatigue shear adhesive strength of coating layer to the substrate. Coated tests specimens 19 mm in diameter are linked to uncoated coupons with a FM1000 or 3M-2214 structural adhesive. A fatigue shear stress is applied to separate the coating and the substrate. Test is stopped at 10 million cycles or after the testing specimen failure. Usually, this test is performed on at least five coated coupons. 4. Mechanical tests : Bending Fatigue Testing Reference standard: ASTM F1160: Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate. Realization of a coating on a substrate can impair the strength of the substrate. The aim of this test is to assess the bending fatigue strength of the substrate covered with the coating in comparison to the uncoated substrate. Test on specimen is stopped at 10 million cycles or after the testing specimen failure with a bending testing machine. Usually, this test is performed on at least five coated coupons. 5. Mechanical tests : abrasion Reference standard: ASTM F 1978: Standard Test Method for Measuring Abrasion Resistance of Metallic Thermal Spray Coatings by Using the Taber Abraser. The aim of this test is to assess the abrasion resistance of the coating layer. A coating disc, 100 mm in diameter is abraded in a 5151 TABER abraser tester with an H-22 wheel during 100 cycles. The weight loss of the specimen is recorded after 2, 5, 10 and 100 cycles. This test is performed on at least 6 coated coupons plus 1 coated reference coupon.

6. Physicals tests : thickness / porosity / roughness / pores sizes Reference standard: ASTM F1854: Standard Test Method for Stereological Evaluation of Porous Coatings on Medical Implants. The aim of this test is to assess the thickness, porosity, roughness and pore size of the coatings. A metallographic cut is done on a coated sample. After cutting and polishing, the cut is analysed by a numerical camera coupled with an optical microscope. This test is to be done on real implants for coating process performance qualification (PQ) on product. 7. Chemicals tests : chemical composition (ICP) Reference standard for HA coatings: ISO 13779-3: Surgical implants Hydroxyapatite chemical analysis and characterisation of the crystallinity and purity phase. The aim of this test is to assess the chemical elements content in the HA powder and coating. The analysis is performed by ICP/SEA emission spectrometry machine. If required, other methods can be used according to the nature of the material analysed and chemical elements to be assessed. 8. Chemicals tests : XRD Reference standard: ISO 13779-3: Surgical implants - Hydroxyapatite chemical analysis and characterisation of the crystallinity and purity phase The aim of this test is to assess the XRD composition of the HA powder and coating. This method gives access to crystalline phases content, cristallinity, Ca/P ratio and estimation of crystallite size by Scherrer method) 9. Chemicals tests : IR Reference standard: FDA Guidelines and ISO 13779-3: Surgical implants - Hydroxyapatite chemical analysis and characterisation of the crystallinity and purity phase The aim of this test is to assess the FTIR composition of the HA powder and coating. According to the wavelength, the functional groups of Hydroxyaptite and possible impurities can be detected and interpreted. 10. Chemicals tests : Helium density Reference standard: Guidelines FDA The aim of this test is to assess the density of the fully dense HA powder and coating. The results are done with a Helium pycnometer. 11. Chemicals tests : dissolution Reference standard: ASTM F1926: Standard Test Method for Evaluation of the Environmental Stability of Calcium Phosphate Granules, Fabricated Forms, and Coatings. The aim of this test is to assess the dissolution rate of the HA powder and coating. At the different sampling intervals, the ph and the quantity of Ca element are measured. Initial and final dissolution rates are analysed. The standard describes the possibility to do the test on coated coupons. For FDA, the test shall be done on particles scraped from the coating. 12. Chemicals tests : corrosion Reference standard: ASTM A 967: Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts Even if medical grade metals resist to corrosion, different parameters can impair their inertness: local heating during the manufacturing of the implant or coating, association of dissimilar materials for the substrate and the coating, lack of homogeneity of the raw material batch, etc The aim of this test is to assess the corrosion of the implant. Different methods are described by the standard: immersion test, ferritic test he most appropriate method has to be chosen according to the nature of the metal to assess.

IQ, OQ and PQ VALIDATION In order to guarantee reproducibility of the coatings on implants, the coating production processes shall be IQ, OQ and PQ validated. Two sets of standards can be taken in reference: The document GHTF/SG3/N99-10 (Quality Management Systems - Process Validation Guidance, Edition 2, 2004) The WHO guide relating to standards of good manufacturing practices (GMP) (WHO/VSQ/97.02, Part 2: Validation, 1997) Installation Qualification (IQ) Tests and checks are performed on the processes installed to verify that they comply with previously established specifications. When the process is subcontracted, this part of the process is the responsibility of the coating service provider. Operational Qualification (OQ) After setting the standard adjustment parameters for obtaining a sample result meeting the specifications, the OQ enables validation of these standard parameters, even when the process is carried out under degraded conditions (validation of adjustment parameters and critical cases). When the process is subcontracted, this part of the process is the responsibility of the coating service provider. Performance Qualification (PQ) This serves to demonstrate that the system yields a reproducible, correct result on the product. The PQ is therefore conducted in two phases: Process PQ: when the process is subcontracted, this test is carried out by the coating service provider. This establishes the long-term reproducibility of the process. It is conducted on coupons. Product PQ: even if the process is subcontracted, this part of the validation is carried out under the supervision of the product manufacturer. This establishes compliance of the process result on the product (usually by performing sections of the coating on the product). PQ VALIDATION OF COATINGS ON PRODUCTS In order to compile one s coating validation dossier, it is first necessary to consider the guidelines used in countries where implants are sold, as the tests asked for in the validation dossiers are not necessarily the same. Once the guidelines or the target market has been identified, the tests to be conducted in order to compile one s coating validation dossier are identified. Next, it is necessary to find out from one s coating service provider which tests he has conducted or routinely conducts, and under what conditions (of thickness and of substrate). By using the information collected above, one can begin compiling the coating validation dossier. All that remain to complete this coating validation dossier are the missing tests which must be conducted in a laboratory on the implant.

Here are examples of several possible cases to illustrate the above comments: 1. The coating service provider has a coating validation dossier, a process performance qualification and the characteristics of thickness and of substrate tested are consistent with those of the coated implants; In this case, only the test for thickness on the coated implants is to be conducted. This verification of thickness on the implant is necessary since, depending on the geometry of the implants (stems, cups, condyles, etc.), shadowing or discrepancies in the coating might occur during the coating application procedure. 2. The coating service provider has a coating validation dossier, a process performance qualification and the characteristics of thickness and of substrate tested are not consistent with those of the coated implants; In this case, all of the tests involving thicknesses / substrate (for e.g. mechanical strength of the coating: tensile, shear, fatigue ) are to be conducted or a rational shall be constructed to explain why the substrate and coating thickness will not have influence on the results (according to the regulatory institutions and countries, this rational is not always accepted). 3. The coating service provider does not have a coating validation dossier but conducts a process performance qualification and the characteristics of thickness and of substrate tested are consistent with those of the coated implants; In this case, the routine tests conducted by the coating service provider must be retrieved and completed along with the other tests required by the validation dossier.

? DESIGN: QUESTIONS TO ASK Is a coating validation dossier required in the country where my products are sold? What are the guidelines for the countries where my products are sold? What is the list of required tests for my coating validation dossier? Can I forego the tests to be conducted and rely on the experience of my coating service provider? Does my coating service provider have a coating validation dossier which I can draw on to compile my coating validation dossier? Does my coating service provider have a process performance qualification on which I can draw? After I have got back the tests from my coating service provider, what list of tests should I conduct? What are my implant categories (groupings based on substrates, thickness, type of coating, geometry of the pieces)? What sample size should I choose for my coating validation (all sizes / minimum or maximum size / critical sizes)?

REASONS FOR CHOOSING MEDICAL GROUP We offer customised solutions to meet your requirements. We work with majors as well as star-up companies Coating used on over 1.5 million implants worldwide Over 20 years experience Operations in 30 countries spread over 5 continents Unrivalled responsiveness Quality of the highest standard A full service partner A multilingual sales team (English, German, Italian, Spanish, Arabic, Chinese ) Our experts can assist you with your regulatory processes ISO 13485:2003 certified Our collaborative interaction helps you limit your suppliers, save time in having your batches released and reduce your transport costs A highly qualified technical team that is very knowledgeable about French, European and US regulatory requirements. We work with medical device manufacturers in various fields such as orthopaedic, dental, spinal, biomaterials, single and multi-use instrumentation.

VARIOUS / ASSORTED / MISCELLANEOUS / SEVERAL CONTACTS Aurélien BIGNON MedicalLab General Manager a.bignon@medicalgroup.fr Stéphane PLET Manager of physico-chemical department s.plet@medicalgroup.fr Alice MARTINHO Manager of microbiological and packaging test department a.martinho@medicalgroup.fr Régine GRIES Quality Control Director r.gries@medicalgroup.fr OUR SALES TEAM Alain BRUNEL Sales Director a.brunel@medicalgroup.fr Rachid ZEROUALI Export Sales Manager r.zerouali@mediclgroup.fr Richard PUZENAT Sales Manager (France) r.puzenat@medicalgroup.fr

MedicalLab MedicalGroup World Wide

5, Chemin du Catupolan - 69120 Vaulx en Velin - France - Tel. 33 (0)4 72 81 22 62 - Fax : 33 (0)4 72 81 22 72