Regolatori per Refrigerazione Digitali FR... 1-2 canali



Similar documents
Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

4-Channel Thermometer / Datalogger

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

CONTENTS General features Front panel and buttons Installation List of the working parameters to be checked before starting the unit

ECP 208. Cold Rooms Controllers USER S MANUAL

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

RAINCONTROL LCD Special

Hand-held thermometer Model CTH7000

Application Unit, MDRC AB/S 1.1, GH Q R0111

Features, Benefits, and Operation

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Multi-Range Programmable DC Power Supplies 9115 Series

Drayton Digistat +2RF/+3RF

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Controller for temperature control - EKC 102 REFRIGERATION AND AIR CONDITIONING. Manual

MP-4000 Alarm List (Software version or later)

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

User's Guide. Integrating Sound Level Datalogger. Model Introduction

ITC-308 Plug and Play Temperature Controller

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

TC-9102 Series Surface Mount Temperature Controllers

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

EBDSPIR-PRM, EBDSPIR-PRM-IP

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Dixell. Electronic Controls Handbook September Programming Flow Charts & Parameter Lists for:

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Installation and User Guide

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

INSTALLATION OPERATING & MAINTENANCE MANUAL

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

Thermostat with display

B/S/H/ Error codes and service programmes PH

Duct Humidity Transmitter

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Gastronorm Supra Cabinet & Counter

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

Air conditioning, electrical testing

Product Information Sheet UH36 Hi Pot Tester

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Digital controller with alarm management XR40CX

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

PID Microprocessor temperature controllers CTD43 - CTD46 - CTH46

Permissible ambient temperature Operation Storage, transport

*.ppt 11/2/ :48 PM 1

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

OZW30. Central Unit SYNERGYR

UM-X Field display for continous level sensors

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Preset Counter signo 721

Features and Benefits

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

HERZ-Thermal Actuators

Nokeval. User's Manual Models 301 / 302 / 305

EC3-D72 Superheat & Digital Scroll Controller Technical Data

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

IO-DIM6 6-Channel, Digital to Analogue Converters

T0118 T2118 T3118. Instruction Manual

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

PD 100A. Printing data system

RRV934. Multi-controller. Synco living

Installation and Operation Back-UPS 1250, 1300, 1500

max 6f / computer max

EK908FHL - Thermostat for floor heating

Back-UPS Pro 1300/1500 Installation and Operation

Instruction Manual. T3111 T3111L T3111P T3111Ex

Single Channel Loop Detector

Electronic Pressure Switch EDS 3000

ABB i-bus EIB Logic Module LM/S 1.1

Transmitter Interface Program

Application Engineering

PIEZOMETER AIRFLOW MEASURING RING

INSTALLATION & SERVICE MANUAL. Display Panel

Product Information Sheet UH28CS-12kV Hi Pot Tester

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

Applied Electronics. Commercial Dimming System UPDATE NOTICE

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Modular I/O System Analog and Digital Interface Modules

SYL-2372 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.4 (May 2016)

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

GREISINGER electronic GmbH

MOUNTING AND OPERATING INSTRUCTIONS

HYDRUS ULTRASONIC METER

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Safety Relays ESM/ESM-F

KD-204. Telephone Remote Switch. Operating Instructions

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

IN-OUT Thermometer with Cable Free Sensor and Clock

Transcription:

Regolatori per Refrigerazione Digitali FR... 1-2 canali Manuale d Uso 1-2 Channel Regulators for Digital Refrigeration System Manuel

Contents Safety warnings Page 20 Technical specifications Page 20 Description of instrument Page 22 Electrical connections Page 23 Glossary Page 23 Operation Page 25 Setting the regulation parameters Page 25 Parameter menu Page 27 Error messages Page 33 Reference standards Page 33 Dimensions and connection diagrams, 33x75 mm Page 34-35 Dimensions and connection diagrams, 4-DIN Page 36-19 -

Series of digital thermoregulator for regulating the temperature that execute 1B type actions (EN 60730-1). SAFETY WARNINGS During the installation and operation of the instrument, the following safety instructions should be followed: 1) The instrument should be installed by qualified personnel 2) Read the instructions in this manual carefully 3) Carefully follow the instruction diagrams to install the device 4) Before gaining access to the connector terminals, make sure the conductors to be connected to the instrument or already connected are not powered 5) Make sure the electric panel in which the device is inserted will prevent access to the terminals after installation 6) Do not supply power to the device if any part of it is damaged 7) The instrument must be installed and activated in compliance with current electric systems standards. 8) The connection cables should be able to resist the maximum operating temperature in the form of the maximum ambient temperature + 20 C 9) The instruments guarantee main insulation between the low voltage parts (250 V) and the extremely low voltage parts 10) Any outside switches connected to the control panel should guarantee a minimum insulation of 250 V AC at operating temperature, or should be protected by equivalent insulation IMPORTANT: In order to avoid malfunctions, the differential of intervention (DF1 or DF2 parameter) should not be set above 30 C. TECHNICAL SPECIFICATIONS Series of digital temperature regulators that satisfy the simplest requirements in the field of refrigeration. They may be used as regulators for the handling of: - Static refrigeration units (with no fan on the evaporator) operating at normal temperatures (over 0 C) The temperature probe to be used is the NTC type. It is also possible to connect a second probe to display the product conservation temperature The instruments are available in the following versions: - FR NTC- with 1 or 2 relay outputs in exchange for the handling of static refrigeration units. In the two relay model, the second relay is dedicated to the handling of the maximum and minimum alarms. Indicated for the handling of STATIC refrigeration units (with no fans on the evaporator) operating at temperatures greater than 0 C. The regulator performs all the functions of a thermometer, with the display of the temperature, and an electronic thermostat, with the activation of a compressor or - 20 -

solenoid valve to maintain the temperature required. It also carries out an automatic defrost function by means of the forced switching off of the compressor. The defrosting frequency and duration can be set. The predefined control action is of the ON/OFF DIRECT type (cannot be modified) Regulators with 3-digit, seven segment and decimal point led display Compressor in operation warning lamp Defrost warning lamp Continuous cycle active warning lamp Alarm intervention warning lamps (FR NTC-1P3.., FR NTC-..DA models only) Display range: -99 +999 C Display resolution: 0.1 C (-9.9 +99.9 C) and 1 C (< -9.9 C and > +99.9 C) Precision: ±0.5 % of measurement ±1 digit Digital mode parameter setting: - Set point - Differential - Output drive times - Digital input delay function - Alarm / buzzer enable delay time - Probe calibration offset - Resolution displayed - Temperature measurement unit - Measurement display filter (update speed) - Probe input type - Password - Interval between defrost operations - Duration of defrost operation - Continuous cycle duration - Duty setting - Defrost parameters SET POINT Operating modes: defrost, duty cycle, continuous cycle and digital input temperature measurement probe inputs: the first probe may be used for regulation and the second to display the product conservation temperature (1 or 2 relay models). Relay outputs with 8 A /250 V AC1 relay exchange contact In the 2 relay models, the second output is dedicated to the handling of the minimum and maximum alarms Rated power output: 4.5VA Max absorption: 100 ma at 12V, 50 ma at 24V Digital input: 1 for outside consent for configurable function outside alarm, probe selection, regulation ON/OFF, defrost handling, night operation (when the contact is close, the set is modified to an offset in degrees) Acoustic and visual alarm signalling for: outside alarm (from digital input), probe alarm (malfunction), minimum or maximum alarm - 21 -

Rear panel 33x75 mm Code Model Power supply (*) Power supply n of tollerance relays VM650900 FR NTC-1P3D from 12 to 24 V AC/DC ± 10 1 VM651700 FR NTC-1P3A 230 V AC 15/+10 1 Modular 4 DIN Code Model Power supply (*) Power supply n of tollerance relays VM659000 FR NTC-1DA 24/230 VAC ± 10 1 VM660800 FR NTC-2DA 24/230 VAC ± 10 2 (*) Power supply in AC - Frequency 50/60 Hz Display 3-digit led display with decimal point. For all the models, the display range is: - minimum display: -99 C or -9.9 C - maximum display: 999 C or 999 C Relay intervention warning lamp: DESCRIPTION OF INSTRUMENT / COMP: LED off if the compressor is off and on if the compressor is on, flashing if the compressor is off and waiting to become on due to active timing / DEF: LED off if defrost is off, on if defrost is taking place, flashing if awaiting defrost execution LED off if continuous cycle inactive, on if continuous cycle is taking place, flashing if awaiting execution of the continuous cycle LED off if alarm inactive, on if alarm active, flashing if alarm timing taking place - 22 -

Keys Three keys are present for the parameter setting operations: OK Confirm and parameter programming/display key Parameter increase or go to next parameter Parameter decrease or exit menu ELECTRICAL CONNECTIONS Carefully follow the instructions in the safety warnings and the connection diagram section. GLOSSARY Set point (set or operating point) The set point is the value at which the device has to intervene to maintain the measurement controlled at the required level. Differential (or hysteresis) The differential is the maximum variation from the operating point of the measurement controlled permitted before the intervention of the device. This is normally set in such a way as to prevent rapid swings in the measurement around the operating point from causing frequent starts and stoppages of the device or the driver connected to it. Direct action regulator acts in direct mode when it carries out a containment action on a measurement that is increasing. typical example is a refrigeration system. the temperature increases, the refrigeration power produced increases correspondingly, with a view to reducing the temperature. ON OFF Direct Mode D Set Set + Diff Temperature - 23 -

Defrost This is a timed defrosting action that takes place by switching off the compressor. It may be timed (by setting the relevant parameter) or forced manually by holding down the up ( ) key for at least 3 seconds. The defrost procedure terminates if: - the defrost time expires; - the up ( ) is held down again for at least 3 seconds; - the unit goes into duty cycle operation due to a probe error. During the defrost operation, both the maximum and minimum alarms are bypassed. Duty Cycle This is the operating mode of the instrument in the event of probe failure. The duty cycle parameter may take on a whole number value from 0 to 100: - 0 compressor constantly off - 100 compressor constantly on - 1-99 the minutes of continuous operation of the compressor, with intermittent fixed stoppage time intervals of 15 minutes This type of operation takes place when sensor alarms are detected. If the instrument is defrosting or in a continuous cycle procedure, these are interrupted, but their timings remain active. If the probe alarm stops, the instrument resumes normal operation. If it was carrying out a continuous or duty cycle procedure and the cycle time has not terminated in the meantime, this will resume at the end of the operation. If the cycle time has terminated, the instrument will return to normal operation. Continuous cycle The continuous cycle runs the compressor constantly for a programmed period (if the temperature of a refrigeration cell has to be reduced rapidly following a loading operation, for example). To carry out the continuous cycle procedure, hold down the down ( ) key for at least 3 seconds. The procedure terminates it: - the continuous cycle time terminates; - the down ( ) key is held down again for at least 3 seconds; - duty cycle operation is started up due to a probe error; - the temperature reaches the minimum alarm threshold. During the continuous cycle, both the maximum and minimum alarms are bypassed. These alarms will remain bypassed for a set period of time after the cycle has terminated. - 24 -

OPERATION Normal operation This is the type of operation that takes place when the parameters are not in advanced programming. The instrument carries out the regulation on the basis of the value measured and the parameters set. The information displayed is as follows: - The temperature measured by the sensor - Compressor status indications - Defrost taking place indication - Continuous cycle taking place indication - Alarm relay status indication SETTING THE REGULATION PARAMETERS o set the regulation parameters, two types of programming are available: - Simplified programming - Advance programming Note: to restore the default values set in the factory, switch on the instrument while holding down the OK key. Simplified programming This is used to modify only the parameters of the regulation menu [REG]. In this regulator, the predefined control action is of the ON/OFF DIRECT type (cannot be modified), which means that the only parameters that can be modified are the set point and differential. Access to this type of programming is gained by pressing OK. Use the up ( ) key to scroll through the parameter labels in a circular movement. Press down ( ) at any time to leave the menu and return to normal operation (this also occurs if no key is pressed for at least 40 seconds). Press OK to switch between the display of the parameter label and its numerical value. To modify a parameter: - from the display of its label or value, hold down OK for at least three seconds - the display will start to flash and show the parameter value - use the p and q keys to increase or decrease the value respectively - press OK to confirm the parameter and leave the modification (the display will stop flashing) - 25 -

Note: if no key is pressed for at least 40 seconds, the instrument will exit the parameter modification without memorising the changes made. During the display and modification of the parameters, the instrument will go on working with the parameters set previously. If password 1 is enabled (access password for the protection of the settings entered see system menu), and the OK key is pressed from normal status, the message - - - will appear. To proceed with the setting of the parameters, enter the password previously set (a numerical value from 0 to 255) with the up ( ) keys down ( ) and press OK to confirm. If the password has been entered correctly, the label of the first menu will appear. Otherwise the system will return to normal status. Advanced programming Access is gained to advanced programming from normal status by holding down the up ( ) and down ( ) keys together for at least 3 seconds. Note: to restore the default values set in the factory, switch on the instrument while holding down the OK key. The parameters are grouped into eight menus by type: 1) Regulation (marked [REG]): set point, differential 2) Output (marked [OUT]): output drive times 3) Digital input (marked [ING]): function, delay time 4) Allarme (marked [ALR]): output status in probe alarm, minimum/maximum shift, differential, delay time, buzzer enable 5) Display (marked [DSP]): set point limits, probe offset, resolution, measurement unit, measurement filter 6) Sensore (marked [SNS]): sensor type, sensor parameters 7) Sistema (marked [SYS]): password, modification enable, operating mode 8) Refrigrazione (marked [REF]): defrost interval, defrost time, defrost parameters All the parameters in the eight menus and their values are listed in the section that follows. - Use the key up ( ) to scroll through the eight menus in sequence - Press OK to enter the menu required - It is possible to scroll through the list of parameters inside each menu can be modified by pressing the up ( ). To display the parameter value, press OK (if OK is pressed a second time, the parameter label is displayed again) - To change the parameter value, hold down OK for at least 3 seconds - The parameter value will start to flash and it can be increased or decreased by pressing the up ( ) and down ( ) keys - Press OK to confirm the value set - 26 -

The parameter will stop flashing and the new value will be displayed - It is possible to return to normal operation at any time by pressing the down ( ) key (or if no key is pressed for at least 40 seconds) Note: if no key is pressed for at least 40 seconds during the modification process, the system will return to the display of the parameter without saving the changes made. Note: during the display and modification of the parameters, the instrument will continue to work with the previously set parameters. If password 2 is enabled (access password for the protection of the settings entered see system menu), if the up ( ) and down ( ) keys are held down for at least 3 seconds from normal status, the message - - - will appear. To set the parameters, enter the previously set password (a numerical value from 0 to 255) with the up ( ) and down ( ) keys and press OK to confirm. If the password has been entered correctly, the label of the first menu will appear. Otherwise, the system will return to normal status. o simplify the advanced programming of the instrument, the parameters have been grouped into various menus, in the following order: - [REG] regulation menu - [OUT] output menu - [ING] outside input menu - [ALR] alarm menu - [DSP] display menu - [SNS] sensor menu - [SYS] system menu - [REF] refrigeration menu PARAMETER MENU - 27 -

Description of parameters Inside the tables, the labels are presented in the same order as that in which they appear in the various menus of the instrument. [REG] regulation menu Labels of Parameter parameters that Description unit values default notes can be modified min max ST1 set point 1 degrees LO1 HI1 4.0 (1) DF1 differential for set point 1 degrees 0.1 100 2.0 Notes: (1) For the values LO1/LO2 and HI1/HI2, see the display menu [DSP] [OUT] output menu Relay functions: FR NTC-..P3, FR NTC-..D.. models - relay 1: compressor handling - relay 2: alarm handling Labels of parameters that Description unit Parameter values default notes can be modified min max ETR Time handling enable on relays - 0 3 3 (2) DON Min time between 2 start-ups of the same relay min 0 200 0 (3) TOF Min relay OFF time min 0 200 0 (4) TON Min relay ON time min 0 200 0 (5) INI Initial instrument start-up delay min 0 200 0 (6) Notes: (2) This parameter enables the handling of the times defined by DON, TOF and TON for each output channel corresponding to relays 1 and 2 in the following way: 0 timing not enabled for both channels 1 timing enabled for channel 1 only 2 timing enabled for channel 2 only 3 timing enabled for channels 1 and 2 (3) This parameter limits the number of start-ups per hour of the driver connected to the instrument (parameter frequently used for compressors, for example) (4) The minimum time for which the output has to remain in OFF status (5) The minimum time for which the output has to remain in ON status (6) The output drive delay time from the instant of instrument reset - 28 -

[ING] outside input menu Labels of parameters that Description unit Parameter values default notes can be modified min max TID Digital input function - 0 7 7 (7) DID Digital input delay min 0 200 0 (8) SUI Output status with active input (open) - 0 3 0 (9) DEL Night-time temperature variation degrees -50.0 +50.0 5.0 (10) Notes: (7) The values that can be set are as follows: 0 inactive 1 Outside alarm (with contact open) with delay time DID and automatic reset at end of alarm. The output status becomes SUI 2 Outside alarm (with contact open) with manual reset. 3 The input operates as a switch: instrument on with contact closed and off with contact open. 4 The input operates as a switch for the display of probes S0 and S1. 5 Enables defrost with contact closed. If defrost is requested the input is open. The request remains pending until the contact is closed. If a defrost cycle is taking place and the contact is opened, the instrument suspends the cycle, but without stopping the timings (this means that it is possible to terminate the cycle for the remaining time by reclosing the contact). 6 The defrost cycle is started by closing the contact. 7 Night operation. With the contact closed, the Set is varied by a quantity in degrees equivalent to DEL. (8) This is the delay following which the instrument responds to a single received at the digital input. (9) When the digital input is active and a period of time DID has lapsed, the outputs may take on the following states: 0 Both channels OFF 1 Channel 1 ON and channel 2 OFF 2 Channel 1 OFF and channel 2 ON 3 Both channels ON (10) This is the variation of the "Set" in degrees when the instrument switches to night operation. - 29 -

[ALR] alarm menu Labels of parameters that can be modified SUA Description unit Parameter values default notes min max Output status in probe alarm condition - 0 3 0 (11) LOA Minimum alarm shift degrees 0.1 100 50 (12) HIA Maximum alarm shift degrees 0.1 100 50 (12) DFA Alarm differential degrees 0.1 100 2 TRA Alarm activation delay time min 0 200 0 SOU Buzzer enable - no yes no (13) EAC Alarm message enable in timing - no yes no (14) Notes: (11) The outputs take on this status in probe alarm condition (see note 9). (12) This value is added to or subtracted from the set point defined for the maximum or minimum alarms respectively. (13) If yes, the acoustic signal and buzzer are enabled in alarm condition. If no, both are disabled. (14) If yes, the type of alarm is also displayed during its timing. If no, the type of alarm is displayed only at the end of the timing. [DSP] display menu Labels of parameters that Description unit Parameter values default notes can be modified min max LO1 Lower limit of set point 1 degrees -99 HI1-99 HI1 Upper limit of set point 1 degrees LO1 999 999 SOF Probe calibration offset degrees -50 +50 0.0 (15) RIS Resolution displayed - HI LO HI (16) UNI Temperature measurement unit - C F C (17) FIL Measurement filter - no yes yes (18) Notes: (15) This value is added to the measurement to compensate for imprecision. (16) The resolution with which the measurement is displayed: 0.1 if HI or 1.0 if LO. (17) Important: when the unit of measurement is modified, the parameters set are not converted automatically but recalibrated. (18) If the parameter is set to yes, a mobile mean is taken from 8 measurement values (that is, over 4 seconds approx). If no, this mean is not calculated. - 30 -

[SNS] sensor menu Labels of parameters that Description unit Parameter values default notes can be modified min max TY0 Sensor type 0-0 3 nt2 (19) TY1 Sensor type 1-0 3 nt2 (19) S01 Display of sensor 0 or 1 flag S0 S1 S0 Notes: (19) The four parameter values are in fact indicated as in the table below: NTC thermal resistances Sensor type Display format (**) nt0 (**) nt1 type 4 nt2 (*) (**) CSt * The instrument is set to this parameter by default. It corresponds to the use of the NTC code VN870200 temperature sensor ** For the use of sensors other than the type 4 referred to above (see note *), it is possible to select one of the three items nt0, nt1, CSt, corresponding to probes with different temperature/resistance ratios. In such cases, we recommend contacting the Technical Assistance Service directly to identify the sensor to select. [SYS] system menu Labels of parameters that Description unit Parameter values default notes can be modified min max PS1 Password 1-0 255 0 (20) PS2 Password 2-0 255 0 (20) NEN Parameter modification enable - yes no yes (21) Notes: (20) The password is enabled if the parameter is different from 000. (21) If set to no, it is not possible to modify any of the other parameters, only to display them. - 31 -

[REF] refrigeration menu Labels of parameters that can be modified DDF Description unit Parameter values default notes min max Interval between defrost cycles h/min 0 200 8 h (22) TDF Defrost duration min/s 1 200 30 min (23) TCC Continuous cycle duration h 0 15 4 (24) TEC Alarm bypass time after cycle h 0 15 2 (25) TED Alarm bypass time after defrost h 0 15 1 (26) DUT Duty setting - 0 100 100 (27) BLD Display block during defrost - no yes no (28) PRT Defrost priority over compressor protection - no yes no (29) BTE Time base - h-min s-min h-min DAC Defrost on start-up - no yes no (30) Notes: (22) Defines how often the defrost cycle takes place. In hours (h) if the BTE parameter is set to h-min, and in minutes (min) if the BTE parameter is set to min-s. (23) Defines the defrost cycle duration; in minutes (min) if the BTE parameter is set to h-min, and in seconds (s) if the BTE parameter is set to min-s. (24) Defines the duration of the continuous cycle (to quickly reduce the temperature after the cell has been loaded). (25) Defines the time following the continuous cycle in which the maximum and minimum alarms are disabled. (26) Defines the time following defrost in which the maximum and minimum alarms are disabled. (27) Compressor ON time in the event of probe failure: 0 always off 100 always on 1-99 ON time (in minutes) followed by a fixed pause of 15 minutes. (28) If set to yes, the temperature displayed is not updated during the defrost cycle. (29) If set to yes, all the [OUT] menu (output menu) timings are bypassed during the defrost phase. (30) If set to yes, a defrost cycle takes place after each instrument reset, even when the DDF parameter is different from 0. If set to no, the first defrost takes place after a time DDF. - 32 -

ERROR MESSAGES Due to alarms or malfunctions, the measurement display may alternate with messages describing the type of alarm. The table below describes the alarm/error messages that may be displayed during operation. Message Type of error Output status ER0 Sensor 1 disconnected or in short circuit As parameter [SUA] ER1 Sensor 2 disconnected or in short circuit As parameter [SUA] ALL Minimum alarm Relay 2 activation (if present) ALH Maximum alarm Relay 2 activation (if present) ALE Alarm from outside input As parameter [SUA] OFF Regulation inhibited from outside input As parameter [SUA] Notes: the OFF message does not alternate with the measurement, but remains fixed on the display. REFERENCE STANDARDS Compliance to the Community Directives: 2006/95/EC (Low Voltage - LVD) 2004/108/EC (Electromagnetic compatibility- EMC) is declared with reference to the follow Harmonised Standard: EN 60730-2-9-33 -

33x75 mm REAR PANEL DIMENSIONS FR NTC-1P3D 75 OK 33 65,5 33 28 70 OK 33 33 FR NTC-1P3A 75 81 28 70-34 -

A l 33x75 mm REAR PANEL DIAGRAMS Model Connection diagram Alimentazione~ 14 11 12 13 15 10 16 17 18 FR NTC-1P3A 5 2 3 4 6 1 7 8 9 Uscita relé 8(1) A/250 V~ NTC1 NTC2 Ingresso sonda NTC Ingresso consenso esterno FR NTC-1P3D Uscita relé 8(1) A/250 V~ i m e n ~ t a z i o n e Ingresso sonda NTC NTC2 NTC1 Ingresso consenso esterno 1 2 3 4 5 6 7 8 9-35 -

4 DIN DIMENSION MODULARS 1 2 3 4 5 6 7 8 9 FR NTC-..DA 87 OK 45 10 11 12 13 14 15 16 17 18 70 60 65 4 DIN DIAGRAM MODULARS Model Connection diagram 230 V~ 5 1 ~ 24 V~ 0-6 0 H z 5 ~ z 0-6 0 H 2 3 4 5 6 Uscita relé 8(1) A/250 V~ 7 8 9 FR NTC-1DA 10 11 12 13 14 15 16 17 18 NTC1 Ingresso consenso esterno NTC2 Ingresso sonda NTC 230 V~ 5 1 ~ 24 V~ 0-6 0 H z 5 ~ z 0-60 H Uscita relé 2 8(1) A/250 V~ 2 3 4 5 6 Uscita relé 1 8(1) A/250 V~ 7 8 9 FR NTC-2DA 10 11 12 13 14 15 16 17 18 NTC1 Ingresso consenso esterno NTC2 Ingresso sonda NTC - 36 -

V3IS00564-010