SR2000 FREQUENCY MONITOR



Similar documents
K2 CW Filter Alignment Procedures Using Spectrogram 1 ver. 5 01/17/2002

MATRIX TECHNICAL NOTES

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Modification Details.

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

Using. SDR-Console by Simon Brown

Tuning Subwoofers - Calibrating Subwoofers

Hideo Okawara s Mixed Signal Lecture Series. DSP-Based Testing Fundamentals 46 Per-pin Signal Generator

RF Measurements Using a Modular Digitizer

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

Spectrum Level and Band Level

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

RECOMMENDATION ITU-R SM Measuring sideband emissions of T-DAB and DVB-T transmitters for monitoring purposes

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Application Note Receiving HF Signals with a USRP Device Ettus Research

Voxengo SPAN User Guide

Sampling Theorem Notes. Recall: That a time sampled signal is like taking a snap shot or picture of signal periodically.

PCM Encoding and Decoding:

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

The Calculation of G rms

Network Analyzer Operation

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

Prepared by: Paul Lee ON Semiconductor

Spectrum Analyzer. Software Instruction Manual

Manual for the sound card oscilloscope V1.24 C. Zeitnitz english translation by P. van Gemmeren and K. Grady

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

How To Use A High Definition Oscilloscope

Lab 1: The Digital Oscilloscope

User s Manual. version Edition PCR AnyWhere. PCR AnyWhere User s Manual 1

FFT Spectrum Analyzers

AR-IQ. Receiver Control, I/Q Record & Playback for AR-ALPHA. AOR Ltd. Authority On Radio Communications

One Port Network Analyzer

Realtime FFT processing in Rohde & Schwarz receivers

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Impedance 50 (75 connectors via adapters)

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Direct and Reflected: Understanding the Truth with Y-S 3

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

MICROPHONE SPECIFICATIONS EXPLAINED


KBA Oktatási Kft OKÉV nyilvántartási szám:

Lock - in Amplifier and Applications

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

How To Use A Sound Card With A Subsonic Sound Card

Basics of Digital Recording

ELAD FDM-SW1 USER MANUAL. Ver. 1.0

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Dithering in Analog-to-digital Conversion

Lab 1. The Fourier Transform

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

GOOD WILL Instrument Co., Ltd. All rights reserved.

Impedance Matching of Filters with the MSA Sam Wetterlin 2/11/11

Transmitter Interface Program

Timing Errors and Jitter

DAS202Tools v1.0.0 for DAS202 Operating Manual

Dream DRM Receiver Documentation

Dynamic Frequency Selection (DFS) and the 5GHz Unlicensed Band

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

The front end of the receiver performs the frequency translation, channel selection and amplification of the signal.

Analog and Digital Signals, Time and Frequency Representation of Signals

Universal Form-factor. Wi Fi Troubleshooting Made Easy

RightMark Audio Analyzer 6.0. User s Guide

Some Measurements on DVB-T Dongles with E4000 and R820T Tuners:

Matlab GUI for WFB spectral analysis

The Fundamentals of Signal Analysis. Application Note 243

RF Network Analyzer Basics

Auto-Tuning Using Fourier Coefficients

A pulse is a collection of cycles that travel together. the cycles ( on or transmit time), and. the dead time ( off or receive time)

Spectrum analyzer with USRP, GNU Radio and MATLAB

AM TRANSMITTERS & RECEIVERS

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

The Phase Modulator In NBFM Voice Communication Systems

Title: Low EMI Spread Spectrum Clock Oscillators

The Sonometer The Resonant String and Timbre Change after plucking

A PIC16F628 controlled FLL (Frequency Locked Loop) VFO for HF

Inductors in AC Circuits

DVB-T 730. User s Manual

(1) Function mode: Displays the currently selected display (Spectrum, Bar graph, and Counter) (see page 23) (2) Scan mode: Displays the selected scan

Voltage. Oscillator. Voltage. Oscillator

Web Streamed SDR s in Service at GB2RHQ Hack Green Bunker

9,'(2 #6(3$5$725 8VHU V#0DQXDO

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz

SIGNAL PROCESSING FOR EFFECTIVE VIBRATION ANALYSIS

Optimizing VCO PLL Evaluations & PLL Synthesizer Designs

Automatic compression measurement using network analyzers

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Voice Communication Package v7.0 of front-end voice processing software technologies General description and technical specification

LEVERAGING FPGA AND CPLD DIGITAL LOGIC TO IMPLEMENT ANALOG TO DIGITAL CONVERTERS

F = S i /N i S o /N o

MAINTENANCE & ADJUSTMENT

SIGNAL PROCESSING & SIMULATION NEWSLETTER

Optimizing IP3 and ACPR Measurements

Transcription:

SR2000 FREQUENCY MONITOR THE FFT SEARCH FUNCTION IN DETAILS FFT Search is a signal search using FFT (Fast Fourier Transform) technology. The FFT search function first appeared with the SR2000 Frequency Monitor, therefore we will refer to the previous Search technology as NORMAL Search, as it is in use in our previous receivers like the AR8600. HOW NORMAL SEARCH OPERATES First we have to decide upon the frequency span and the step size to base our example on: 1 Lowest frequency limit Highest frequency limit Frequency Span Frequency step Search Direction 83.0MHz 93.0MHz 10MHz(=93.0 83.0) 100kHz Ascending After setting the above search parameters, the following actions occur: 1. The lowest frequency limit 83.0MHz is set. 2. The SR2000 checks the presence of a signal. The receiver will stop on a signal if it detects one as set in the parameters. 2 3. If the previous signal disappeared or the signal is not within fixed parameters, the search will continue at the previous frequency plus the frequency step. 4. The SR2000 checks the presence of a signal. 5. Step 3 & 4 are repeated until the checked frequency becomes the highest frequency limit set above. 6. Return to step 1 when the highest frequency limit has been reached.

Normal Search speed calculations 3 For instance the AR8600 searches 37 steps per second. On the other hand, the total number of channels to search is calculated as below: 93.0MHz 83.0MHz 0.1MHz + 1 = 101 channels (100kHz = 0.1MHz) Dividing the number of channels to scan by the search rate gives the time necessary for a total search between the lowest and highest limit frequencies, providing no signal was present. 101 37 = 2.72973 seconds The next example is based on a frequency step of 10kHz only, which is 10 times smaller than in the previous case. 93.0 83.0 + 1 = 1,001 channels 0.01 As there are roughly 10 times more channels to process, it will take 10 times more time to the AR8600 to cover the same range, therefore about 27 seconds. As the search time is directly depending on the frequency range and frequency step, it is easily imaginable about how long it would take to make a full 25-3000MHz search with a 5kHz step. How to speed-up the search? With the Normal Search method, there is a limit at speed improvements, since even if the search rate would be 100 channels per second, it would only represent an improvement of 100/37=2.7 times. Although it looks good at first, it is only minimal in regards to the large band portions to search. The search method is the real problem. This is where the SR2000 has a very different approach, with its: THE FFT SEARCH FUNCTION FFT is explained here in a simplified style, therefore please consult engineering and mathematics manuals for further details. FFT stands for FAST FOURIER TRANSFORM, a mathematical analysis of nonperiodic signals. It s an equation to calculate the frequency, amplitude and phase of each sine wave needed to make up any given signal.

FFT SEARCH vs. NORMAL SEARCH What is the difference between NORMAL SEARCH and Fast Fourier Transform SEARCH? What makes it really Fast? Let s take an example of +/- frequency span of 50kHz (total 100klHz) around 10.7MH.z. Signals are analyzed at a step size of 4kHz. In the case of NORMAL SEARCH: 1. The lowest frequency limit is set at 10.2MHz(10.7-0.5). 2. Signal presence is checked. 3. When a signal is detected, it s frequency and signal strength is then recorded. 4. The search will continue at the previous frequency plus the step frequency, repeating steps 2 to 4, until the frequency reaches 11.2MHz (10.7 + 0.5). In the case of FFT SEARCH: 1. 10.7MHz is set as the center frequency. 2. The signals are processed by FFT. 3. FFT processed data output That s all! The receive frequency remains unchanged. Processing speed comparison: For Normal Search, let s use the same example based on the AR8600, of which search rate is 37 channels per second. 11.2 10.2 + 1 = 26 0.004 Therefore the time necessary to complete the search is 26 / 37 = 0.7 seconds. For FFT Search, the SR2000 and its FFT have the power of sweeping a whole 10MHz span in only 0.85 seconds 4, therefore for only a small portion of 100kHz, it would take:

0.85 0.1 10 = 0.0085 sec. ( = 8.5 1000 sec.) In this case, FFT allows a search, which is 0.7 / 0.0085 = 82.35 times faster than Normal Search! Now let s compare both technologies in an example where the entire range between 25 and 3000MHz would have to be searched with a step size of 100kHz. Normal Search - Calculation of the number of channels to be scanned: 3000 25 + 1 = 29,750 channels 0.1 Therefore the time necessary is 29,750 / 37 = 804.05 sec. = 13.4 minutes. FFT Search 3000 25 0.85 = 252.88 sec = 4.2 min. 10 In this case the SR2000 and its FFT is 13.4 / 4.2 = 3.19 times faster than a Normal Search. It looks only as an OK result but this is because of the step frequency of 100kHz. In the case of a smaller 10kHz frequency step, the FFT shows its real power, as follows: 3000 25 0.01 + 1 = 297,500 channels Compared to a 100kHz step size, 10kHz implies 10 times more channels, thus 10 times more time to complete the search. It would take 8040.5 seconds, or approx. 134 minutes with Normal Search to be completed. But as FFT Search is not step size dependant 5, it would take only 4.2 minutes, which is 31.9 times faster than Normal Search and this demonstrates the incredible power and speed of FFT SEARCH! A full range (25MHz-3,000MHz) search which took more than 2 hours to complete is now possible in just 4.2 minutes thanks to FFT SEARCH!! You might wonder why the SR2000 still features the Normal Search. As a matter of fact the ways of using Normal Search and FFT Search are quite different and therefore Normal Search can still be more suitable for certain application, as explained below: NORMAL SEARCH allows the automatic audition of detected voice signals, as search progresses. But search is only linear.

FFT SEARCH is principally about signal detection. It s point is to detect signals, determine their frequency & signal strength 6, and this in real time on the entire set frequency range, not in a linear order like for Normal Search. In addition, the detected frequencies are listed on the screen and you can tune the receiver to the frequency of your choice for listening, by simply moving a cursor. There are also smaller technical particularities as follows: Very faint signal detection. Although the SR2000 RFU noise floor is at approx. 117db, FFT Search detects signals starting at 100dB. For this reason it is advised to use Normal Search for the detection of extremely week signals between these two values. Resolution bandwidth below 4kHz. The Resolution Bandwidth is fixed at 4kHz for FFT Search, therefore it is advisable to use Normal Search if you seek to detect more than one signal within the 4kHz bandwidth. 7 FFT Search operation details FFT Search on spectrum display The following screen shot (1) shows the detection of two signals, both at 53dB. Screen shot 1: VFO mode

FFT Search in numbers With help of the dial operated marker, you could visually tune to any signal over 60dB and check the exact frequencies. Screenshot 2: FFT SEARCH in action SR2000 at work The Frequency Monitor s job is for example to tell you all frequencies within a given bandwidth which represent a signal stronger than 60dB. The results of this FFT search are given either by a spectral visualization (see screen shot 1), or in a list of frequencies with color coded signal strength (see screen shot 2). In this case the data is also streamed through the serial port for PC analysis. What if the frequency span to search exceeds 10MHz? Although the maximum frequency span in VFO Mode is 10MHz in FFT Search mode this range is only limited by the RFU s reception range (25-3,000MHz). The RFU unit s IF output is at 10 MHz., which sets the limits for the VFO frequency span. In FFT Search mode the SR2000 can achieve a full range 2975MHz search by shifting the RFU as described below: First the RFU is set at 30MHz +/- 5MHz and this 10MHz section will be searched. Then the RFU is set at 40MHz +/- 5MHz and this new 10MHz section will be searched The same method is applied until the RFU reaches the upper frequency limit of 3,000MHz.

Footnotes: 1 Various other secondary but necessary settings like receive mode and squelch are omitted here, to simplify the explanation. 2 For the AR8600, as well as other AOR receivers, the time after which the search will resume, depends on the Search Free settings of the receiver. 3 Calculation here are based on typical specifications as per manual, nevertheless in real use situations, results might vary depending on external factors. 4 Although the spectrum display is indeed refreshed every 0.2 seconds, it takes more time for the RFU to switch frequencies. For those reasons it takes the SR2000 in reality 0.85 seconds for a 10MHz sweep. 5 As it takes time for the SR2000 to send the results to the screen and through the serial port, the actual search speed might decrease depending on the number of frequencies found during the sweep. 6 The signal strength value is output through the serial port to the PC. 7 Although it is possible to set a resolution bandwidth of 1 or 2kHZ in FFT Search, the results are calculated by interpolation.