Measurement and Calibration



Similar documents
Calibration of Glassware

Experiment 1: Measurement and Density

Assessment of Accuracy and Precision

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Glassware Calibration Guidelines Laura B. Secor and Dwight R. Stoll, 02/01/2012 Adapted from National Bureau of Standards Document

EXPERIMENT 9 Evaluation of the Universal Gas Constant, R

Density Determinations

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Determination of Citric Acid in Powdered Drink Mixes

The introduction of your report should be written on the on the topic of the role of indicators on acid base titrations.

COMMON LABORATORY APPARATUS

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Calibration of Volumetric Glassware

Determining the Identity of an Unknown Weak Acid

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

The volume of a penny will be calculated from its mass and density.

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Calibration of Volumetric Glassware

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Density Determinations and Various Methods to Measure

DETERMINING THE DENSITY OF LIQUIDS & SOLIDS

SEPARATION OF A MIXTURE OF SUBSTANCES LAB

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

Vitamin C Content of Fruit Juice

Experiment 4 The Relationship of Density and Molarity of an Aqueous Salt Solution

PERCENT ACETIC ACID IN VINEGAR EXPERIMENT 15

Experiment 7: Titration of an Antacid

Determining Equivalent Weight by Copper Electrolysis

HEAT OF FORMATION OF AMMONIUM NITRATE

Analyzing the Acid in Vinegar

Molar Mass of Butane

Ascorbic Acid Titration of Vitamin C Tablets This lab will be completed individually! Make sure you come prepared!

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Acid Base Titrations

Juice Titration. Background. Acid/Base Titration

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Hands-On Labs SM-1 Lab Manual

EXPERIMENT 10: TITRATION AND STANDARDIZATION

Laboratory Exercise: The Precision of Volume Measurements

Experiment 6 Coffee-cup Calorimetry

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

Concentrations and Dilutions of Food Dyes

LAB #3: MEASURING SPECIFIC GRAVITY AND DENSITY. Set-up and Materials for Experiment

THE LABORATORY NOTEBOOK

Acid Dissociation Constants and the Titration of a Weak Acid

Three Methods for Calculating the Buoyant Force Gleue: Physics

Acid Base Titration: ph Titration Curve

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

The Analytical Balance

Pre-Lab Notebook Content: Your notebook should include the title, date, purpose, procedure; data tables.

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

18 Conductometric Titration

Carolina s Solution Preparation Manual

Apr 17, 2000 LAB MANUAL PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)

Significant Figures, Propagation of Error, Graphs and Graphing

Determination of a Chemical Formula

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

Determination of the Mass Percentage of Copper in a Penny. Introduction

Density. mass m volume V

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

CSUS Department of Chemistry Experiment 8 Chem.1A

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Figure 1. A typical Laboratory Thermometer graduated in C.

Experiment #2: Determining Sugar Content of a Drink. Objective. Introduction

SOLUBILITY OF A SALT IN WATER AT VARIOUS TEMPERATURES LAB

Apparatus error for each piece of equipment = 100 x margin of error quantity measured

EXERCISE # 1.Metric Measurement & Scientific Notation

Chemistry 101 Generating Hydrogen Gas

The Determination of an Equilibrium Constant

The Molar Mass of a Gas

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Solutions and Dilutions

Physical Properties of a Pure Substance, Water

Lab #10 How much Acetic Acid (%) is in Vinegar?

PREPARATION FOR CHEMISTRY LAB: COMBUSTION

Coordination Compounds with Copper (II) Prelab (Week 2)

Osmosis Demonstration Lab

Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS

The Empirical Formula of a Compound

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Determination of the Amount of Acid Neutralized by an Antacid Tablet Using Back Titration

SOLUBILITY, IONIC STRENGTH AND ACTIVITY COEFFICIENTS

Determination of the Percentage Oxygen in Air

Colorimetric Determination of Iron in Vitamin Tablets

TITRATION OF VITAMIN C

Solubility Product Constants

Transfer of heat energy often occurs during chemical reactions. A reaction

Sugar Identification using Polarimetry

PREPARATION AND PROPERTIES OF A SOAP

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS. Final text for addition to The International Pharmacopoeia

ES 106 Laboratory # 3 INTRODUCTION TO OCEANOGRAPHY. Introduction The global ocean covers nearly 75% of Earth s surface and plays a vital role in

The Determination of Acid Content in Vinegar

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

Chapter 3 Student Reading

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

PHYSICAL SEPARATION TECHNIQUES. Introduction

EDTA Titrations 1: Standardization of EDTA and Analysis of Zinc in a Supplement Tablet. by Professor David Cash. September, 2008

Transcription:

Adapted from: H. A. Neidig and J. N. Spencer Modular Laboratory Program in Chemistry Thompson Learning;, University of Pittsburgh Chemistry 0110 Laboratory Manual, 1998. Purpose To gain an understanding of the relationships that exist between density, mass, and volume while calibrating laboratory glassware. Introduction Measurement is a regular part of life. For example, weight, height, and blood pressure are routinely measured in a doctor s office. In the kitchen, ingredients for a recipe must be measured. Devices, such as scales and measuring cups, were developed to make these measurements. In chemistry, solutions are often used and transferred from one container to another. In some cases, it is important to know the amount of liquid transferred with certainty, especially when performing a quantitative analysis. Quantitative analysis is the determination of the concentration or amount of substance in a particular sample. The certainty of a measurement is determined by looking at both the accuracy and precision of a set of measurements. While ideal measurements should be both accurate and precise, measurements made in the lab are more often either accurate but not precise or precise but not accurate. Accuracy is a measure of how close a data point is to an accepted (true) value. If multiple measurements are made of a value, then the accuracy is determined by taking the average value and comparing it to the accepted value. The absolute error is the difference between the accepted value and an individual measurement % error measured accepted x 100 accepted or average. The relative error is the absolute error divided by the accepted value. Thus percentage error is relative error multiplied by 100. Absolute error, relative error and percentage error are all measures of accuracy. The percentage error is often expressed as a positive number, regardless of whether the measured value is larger or smaller than the accepted value. The term precision is used either as it refers to one measurement or a group of measurements. The uncertainty of reading an individual measurement is called the precision of that measurement. Our top-loader balances are precise to 0.001g. Precision can also refer to how close a number of data points are to each other. In this case the precision of a group of points can be evaluated by calculating the standard deviation, which uses the average of the set of data points and the difference between the average and each point. To express accuracy and precision quantitatively, the proper number of significant figures must be used. When using balances, write down the mass with the same number of significant figures as the balance allows (in our case this is about 4 or 5). If a mass is displayed as 24.5674 grams, this means that all but the last digit are known with certainty; last digit has some degree of uncertainty. However, if the balance is fluctuating in the last two digits, then both of those numbers have error associated with them. When reading a buret or other calibrated scale, the volume should be estimated to one digit beyond what the marking allows. Therefore, if a buret is calibrated to the nearest 0.1 ml, then the volume measurement should be made to the nearest 0.01 ml. This method is consistent with the recommended use of significant figures. For example in a volume reading of 11.74 ml, the 11.7 ml is known with certainty while the 0.04 ml was estimated by the person reading the buret. Revision F15 Page 1 of 9

Precision is often related to the person making the measurement; very seldom do two different people make the exact same measurement every time. However, as long as the measurement is made in a consistent manner, the precision should not be significantly affected. In this experiment, water will be measured and delivered using a buret, a graduated cylinder, a beaker and a volumetric pipette. Based on the results, the most accurate measuring device will be determined. Reference Data Density of Water as a Function of Temperature T ( o C) Density (g/ml) 20 0.9982071 21 0.9979955 22 0.9977735 23 0.9975415 24 0.9972995 25 0.9970479 26 0.9967867 27 0.9965162 28 0.9969748 29 0.9962365 30 0.9956502 Revision F15 Page 2 of 9

Procedure Remember to record all measurements and unknown numbers (if given) on your data sheets. Remember to use the proper number of significant figures for all measurements. Part A: Determining the Accuracy of a Buret A1. Obtain a buret, and fill with de-ionized water using a beaker and funnel. Let the water drain through the buret until the tip is full. Observe and sketch the form of the meniscus on the calculations page (page 7). Remember that measurements must always be made at the bottom of the meniscus for aqueous solutions in glass and estimated to the 0.01 ml for a buret. A2. Obtain a 50 ml beaker. Measure and record its mass as the initial mass of the beaker. A3. Read and record the initial water level in the buret. Deliver approximately 15 ml of water from the buret to the empty, pre-weighed beaker. Read and record the water level in the buret again. A4. Measure the mass of the beaker and water and record as the final mass of the beaker. Empty the contents of the beaker into the drain. A5. Repeat steps A3 and A4 two more times. A6. Measure the temperature of your water, and use this measurement and the attached density table to determine the density of the water. A7. Use the mass of water delivered and the known density of water to calculate the actual (accepted) volume of water delivered from the buret. Part B: Determining the Accuracy of a Graduated Cylinder B1. Obtain a dry 100 ml graduated cylinder. B2. Add de-ionized water to the 22 ml mark, using a dropper pipette to get as close to this mark as possible. B3. Dry your 50 ml beaker from part A and weigh it. Transfer the water from the graduated cylinder to the beaker and weigh the beaker. B4. Repeat steps B2 and B3 two more times. B5. Using the density of water at the lab temperature, calculate the actual (accepted) volume of water delivered from the graduated cylinder. Part C: Determining the Accuracy of a 50 ml beaker C1. Weigh a clean, dry 50 ml beaker that has graduation marks on it. Record its initial mass on your data sheets. C2. Add de-ionized water to the 20 ml mark, using a dropper pipette to get as close to this mark as possible. C3. Weigh the filled beaker. Record this value on your data sheets as the final mass of the beaker. C4. Empty and dry the beaker, and then repeat this measurement two more times. C5. Using the density of water at the lab temperature, calculate the actual (accepted) volume of water delivered from the 50 ml beaker. Revision F15 Page 3 of 9

Part D: Determining the Accuracy of a 10 ml volumetric pipette D1. Obtain a 50 ml beaker. Measure and record its mass. D2. Use a pipette bulb to fill the volumetric pipette to its calibration mark with di water from a different beaker. Empty this volume of water into the pre-weighed 50 ml beaker. D3. Measure the mass of the beaker and water and record this as the final mass of the beaker. D4. Repeat steps D2 and D3 two more times. D5. Measure the temperature of your water, and use this measurement and the attached density table to determine the density of the water. D6. Use the mass of water delivered and the known density of water to calculate the actual (accepted) volume of water delivered. Calculations A1. Determine the volume of water delivered by the buret in each trial by subtracting the buret readings. This is your measured value. A2. Determine the calculated volume of water using the mass of water delivered and the density value from the table on page 2. This is your accepted value. A3. Compare these values and calculate the percent error for each trial. B1. Assume the volume of water delivered (measured) from the graduated cylinder for each trial is 22.0 ml. Compare these values to the calculated (accepted) volumes obtained by using the density of water and the delivered mass of water. Then calculate the percent error for each trial. C1. Assume the volume of water (measured) in the beaker for each trial is 20. ml. Compare this value to the calculated (accepted) volumes obtained by using the density of water and the delivered mass of water. Then calculate the percent error for each trial. D1. Assume the volume of water delivered (measured) from the volumetric pipette for each trial is 10.00 ml. Compare this value to the calculated (accepted) volumes obtained by using the density of water and the delivered mass of water. Then calculate the percent error for each trial. Enter data and calculated values into data tables. Be sure to label all values with units! Attach sheet of calculations to data table sheet. Revision F15 Page 4 of 9

Data Sheet Name: Lab Partner: Part A: Determining the Accuracy of a Buret Trial 1 Trial 2 Trial 3 Final water level in buret Initial water level in buret Volume of water delivered (measured) Final mass of beaker Initial mass of beaker Mass of water delivered Temperature of water Density of water from table Calculated volume of water (accepted) % Error Part B: Determining the Accuracy of a Graduated Cylinder Measured volume of water (measured) Final mass of beaker Trial 1 Trial 2 Trial 3 Initial mass of beaker Mass of water Temperature of water Density of water from table Calculated volume of water (accepted) % Error Revision F15 Page 5 of 9

Part C: Determining the Accuracy of a 50 ml Beaker Measured volume of water (measured) Final mass of beaker Trial 1 Trial 2 Trial 3 Initial mass of beaker Mass of water Temperature of water Density of water from table Calculated volume of water (accepted) % Error Part D: Determining the Accuracy of a Volumetric Pipette Measured volume of water (measured) Final mass of beaker Trial 1 Trial 2 Trial 3 Initial mass of beaker Mass of water Temperature of water Density of water from table Calculated volume of water (accepted) % Error Revision F15 Page 6 of 9

Calculations: Revision F15 Page 7 of 9

Post-lab Assignment Name: Lab Partner: 1. Based on your results, which piece of glassware is more accurate in delivering liquids the buret or the graduated cylinder? Explain your choice. 2. Based on the smallest scale division, which measuring device in question one should provide the more precise measurement of volume? Explain your choice. 3. Is either piece of glassware completely accurate and precise in delivering a given volume of liquid? What additional factors must be acknowledged? 4. Consider the definition of precision. Do you feel any of the glassware used in lab today were precise? What criteria are you using to make your decision? Revision F15 Page 8 of 9

Pre-lab Assignment Name: 1. Define the following terms in your own words: a) Accuracy b) Precision 2. A student calibrated a 10-mL graduated cylinder using water. The empty graduated cylinder weighed 23.873 grams. When it was filled with 10.00 ml of deionized water, it weighed 33.1062 grams. The temperature of the water was 23.5 o C. a) Use the density of water obtained from the table on page 2 and the mass of water to determine the accepted volume of water in the graduated cylinder. b) Calculate the % error of the graduated cylinder. Revision F15 Page 9 of 9