Plumbing for retail food businesses



Similar documents
31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Additional Services Agreement. Part 3: Schedule of our requirements

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

Grease Traps and Interceptors

WHY A FATS, OILS AND GREASE PROGRAM. Employee Food Service Establishment Information Sheet INTRODUCTION

Editorial Note: bold and underline denotes added text, strikethrough denotes deleted text

Fats, Oils, and Grease Best Management Practices Manual

Grease Trap Maintenance, Procedures and Cleaning Logs

How To Keep Grease Out Of The Sewer

Food Service Facilities

Standard terms and conditions

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

National Precast Concrete Association

How To Prevent Grease From Getting Into The Water System

The Town of Lakeshore Basement Flooding Information to Residents

Disposal of Fats, Oils, Grease and Food Waste Best Management Practice for Catering Outlets

Louisville and Jefferson County. Metropolitan Sewer District Fats, Oils & Grease (FOG) Management Guidelines. Policy Adopted: May 27, 2008

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

40 ltr Domestic Grease Trap GTO ltr Commercial Grease Trap GTO2. Rotational Moulders providing State of the Art Product Design and Developement.

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

SEPTIC TANK SYSTEMS. Single purpose septic tank receives toilet wastes (blackwater) or sullage (greywater) only.

PREVENTING WET OR FLO ODED BASEMENTS

Manual contents includes:

FOOD SERVICE WASTEWATER DISCHARGE PERMIT APPLICATION

BASEMENT FLOODING. Prevention Guide for. Homeowners

Drainage and Grease Management for the Commercial Kitchen

Fats, Oil, and Grease (FOG) Best Management Practices (BMP) For Food Service Facilities. Guidance Manual

Prevent Blockages in the Sanitary Sewer System

Grease and Oil Wastes Problems andsolutions A grease trap is a device used for removing oil and grease from wastewaters. Grease traps perform this

FOG PRETREATMENT INFORMATION. New London Public Utilities F.O.G. Program 120 Broad Street New London, CT 06320

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

GUIDANCE DOCUMENT FOR SIZING AND INSTALLATION OF GREASE TRAPS AND INTERCEPTORS

6. Principles of effective plumbing systems

12. Design of plumbing systems for single dwellings

1.2 How Does FOG Affect You? The City of Huntington Beach FOG Control Program.. 2

MODEL WEB CONTENT FOR CITY SANITARY SEWER DEPARTMENTS

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

STEPS NECESSARY FOR APPROVAL TO OPERATE A FOOD SERVICE ESTABLISHMENT

Fats, Oil and Grease Program Kit

Plumbers Guide Pitt Town Water Plumbers Guide, December 21, 2012

Plumbing Code Sections For Commercial Food Facilities

FOG Program Fats, Oils & Grease

POLICY. (EFFECTIVE January 1, 2000)

SEPTIC SYSTEM. Taking care of your. ... what you need to know

Environmental Management System Procedures

St. Joseph, Missouri Water Protection Homeowners Guide to Your Sewer

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

Your Pressure Sewerage System Guide

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010

Grease 101. Why is Grease a Problem?

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

Compliance Department

Septic Tank Use & Maintenance Tips

ALL YOU NEED TO KNOW...

your water pressure explained

Plumbing Handbook. A guide to working with Water Corporation. As endorsed by

Protect your home from basement flooding

CERTIFYING DRAINLAYER

Please also see 10 golden rules for correct Saniflo installation on

Guidelines for Precast Concrete Grease Interceptors

TOWNSVILLE WATER Customer Service Standards

Best Management Practices Fats, Oils, & Grease

16. Storm water drainage

City of Clare Grease and Sand Interceptor Policy

SF15K SF05KSS, SF10KSS

PLUMBING & CROSS-CONNECTION CONTROL

Understanding Septic Tank Systems

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Septic System Owner s Manual

PLUMBING ROUGH IN INSPECTION

At the end of today s seminar you should be better. Recognize the causes of Sewer Lateral backup. Identify techniques to protect your home from

Help protect our special places by maintaining your septic tank

Heating and Domestic Hot Water Systems for dwellings Achieving compliance with Part L 2008

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Essential Water. Customer Charter

A Guide to Sewer Backups

Frequently Asked Questions about Septic Systems

How do I clean my grease trap? Refer to Grease Trap and Interceptor Maintenance.

Working together to prevent leaks. dripping

Looking after your Septic Tank System

Proposed plumbing system within units at the Bluewater Hotel, 10 West Quay, Ahuriri, Napier

Plumbing Code in Commercial Kitchens

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

Compliance Document for New Zealand Building Code Clause G13 Foul Water Second Edition

Safe Method: Gas Safety in Catering Establishments

Top 10+ Mistakes of DWV plumbing design

COMPREHENSIVE PROPERTY INSPECTIONS

Village of St. Louis Sewer Back-up Policy

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Residential Plumbing BCN 1058

Bio-Clean. for Septic Systems. Tips for Using Bio-Clean. Page Index METRIC CONVERSIONS

DRAFT Guidelines for Manually Diverting Outdoor Wastewater to the Sanitary Sewer

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

Fats, Oils and Grease

Transcription:

Plumbing for retail food businesses Every day, thousands of food outlets in Sydney produce waste, such as cooking oil, grease and food solids. If that waste is discharged directly into our sewers, it can cause blockages and overflows, overload wastewater treatment plants and cause major pollution problems in our rivers and on our beaches. Plumbers can help retail food businesses effectively manage and dispose of greasy wastewater by correctly installing grease traps and other devices. Grease traps If you cook or serve hot food, you must install a grease trap and have a trade waste agreement with Sydney Water. Wastewater from food preparation areas, floor wastes, kitchen sinks, dishwashers and garbage areas should all flow to your grease trap. Install grease traps as close to the source of grease as possible, so that pipes between the kitchen and the grease trap don t clog with grease. If you can t avoid long pipe runs, such as in shopping centres, you can use a heat trace or increase the grade. Grease traps must be at least 1,000 litres, because this is the minimum size to capture grease efficiently. The maximum size is 5,000 litres to ensure ease of pump outs and clean outs. Kitchen wastewater should preferably drain by gravity to the grease trap and then by gravity to the sewer. If this is not possible, kitchen wastewater can drain to an under sink pump unit or to a pump well outside the kitchen. You can also configure a grease trap to drain to a pump well, and pump wastewater to the sewer from there. Any pump well or pump unit must be accessible for maintenance. Connect a pumped line into the inlet to the grease trap, above the double junction inlet, laying at least the last meter horizontally. Do not install a pumped system for convenience, as it is more difficult and expensive to manage and maintain in operation. When you apply to us for approval, Sydney Water will ask you to explain why the wastewater cannot drain to the grease trap by gravity. Do not direct wastewater from potato peeling machines to a grease trap, as it contains starch rather than grease. Neat fat and oil generated by cooking processes (refer to minimum pre-treatment table page 6 of this document) must be collected for recycling. It must not drain directly to a grease trap or the sewer. We only permit authorised grease traps to be installed. Please refer to authorised pre-treatment listings on sydneywater.com.au

Plumber s Certificate of Compliance When a grease trap is installed, Sydney Water requires a Certificate of Compliance. Make sure you engage a licensed plumber to install your grease traps and that you obtain a Certificate of Compliance for this work. Venting grease traps Venting the grease trap is an important requirement of the pre-treatment installation. The venting pipework must be 100 mm diameter minimum. All grease trap installations must have: two 100 mm vents open to the atmosphere for cross ventilation an induct vent, either high or low level directly off the grease arrestor a high level educt vent off the incoming drainage. Use of air admittance valves to vent grease traps is not permitted, but air admittance valves on branch lines and over distance branch lines draining to grease traps are permitted, but must be installed following the Plumbing Code of Australia. Inlet and outlet pipework Inlet and outlet pipework for grease traps is not part of pre-treatment and does not come under the jurisdiction of Sydney Water. Instead it is covered in the applicable plumbing and drainage codes and standards and this work is inspected by the NSW Department of Fair Trading. Maintaining grease traps The space above the grease trap must be at least equal to the depth of the grease trap. This allows enough access space to monitor the grease trap, remove the grease trap lid, maintain it and get it pumped out. Do not install other services, such as air conditioning ducts, where they will block access to the grease trap lid. Preferable drainage layout for a grease trap installation

Safe access for grease trap waste inspection and maintenance All above ground grease trap installations require a platform and steps manufactured to Australian Standard 1657-1992 for safe access for inspection and maintenance. Grease trap contractors must be able to park as near as possible to a grease trap to service it. They have fairly long suction hoses to access the traps, but the closer they can get the better. If you are in any doubt, ask one of the contractors and obtain a written agreement that they can service the trap. Floor and sink waste bucket traps In addition to grease traps, you must install authorised in-sink and in-floor waste bucket traps in all sinks and floor wastes in all commercial kitchens and food preparation areas. In-floor bucket trap In-sink bucket trap Fixed pump-out lines It is possible to install a fixed pump-out line to enable future servicing s (these are not part of the pre-treatment and are not specified by Sydney Water). Installing a fixed pump-out line may require council approval. You must consult a grease trap waste contractor, if you intend to install a fixed pump-out line. Experience has shown that a fixed pump-out line must be as straight as possible. Use long radius bends, if bends are required. Lines should be a minimum diameter of 75 mm in a robust material, such as galvanised iron. Fixed pump-out lines should terminate near the grease trap but not in it, as a flexible line needs to be attached to ensure all of the waste is collected from inside the trap. Lines require cam-lock fittings at both ends to the pump-out contractor s specifications and caps for the cam-lock fittings to prevent odours when lines are not in use. Cleaning grease traps Grease traps must be pumped out regularly to avoid overflows, odours and polluted wastewater. When your plumbing contractor pumps out your grease trap they will also need to clean the grease trap s internal surfaces, and may need to scrape the inside of the trap. You don t need to completely refill the trap. Sydney Water will specify how often your grease trap must be pumped out. This depends on the size of your grease trap and the amount and quality of greasy wastewater you generate. If you are a Sydney Water customer with a grease trap, you will be part of our Wastesafe program. Wastesafe manages scheduling, collecting, transporting, and disposing waste.

Managing waste oil Grease traps are designed to treat greasy wastewater. They are not designed to accept waste oil tipped into them. Waste oil should never be poured down the drain or into your grease trap. Collect waste oil from deep frying and BBQ s, store it in sealed containers in a properly bunded area and have an oil recycler collect it. Multiple grease traps If you manage a shopping complex or small shopping centre, you may have multiple grease traps. Grease traps must be big enough to treat all the wastewater from all of the businesses that use them. If your grease traps aren t big enough to treat all the wastewater from all the businesses that use them, you must upgrade. Multiple grease traps at the one site can have a maximum capacity of 30,000 litres. For example, you may have six grease traps of 5,000 litre capacity each. Centralised pre-treatment for shopping centres If you need more than 30,000 litre grease trap capacity, you must install centralised wastewater treatment, such as dissolved air flotation (DAF). DAF separates grease and light suspended solids from wastewater by floating them to the surface on fine air bubbles. Boundary trap A boundary trap must be installed on all retail food properties with a gravity connection to the sewer. If the property does not have a boundary trap and the customer has applied for a connection to discharge trade waste, the customer must install a boundary trap at the boundary or the point of connection, if this is within the property boundary.

Disconnecting a grease trap If your business process changes and you no longer need to discharge trade wastewater to the sewer, you must contact Sydney Water to cancel your agreement and disconnect your grease trap(s) from the sewer. A licensed grease trap transporter should empty the trap, before it is disconnected. A licensed plumber then puts a pipe through or around the grease trap (from inlet to outlet) and fills it with sand or blue metal. Repairing or replacing a grease trap Although a grease trap has a long lifespan, they can wear out and become hard to clean and may develop holes and start to leak. It is sometimes very difficult to repair some that have contained grease for many years, and it may be better to replace them completely. Seek advice from a grease trap manufacturer or licenced plumber on options for repair or replacement, and apply to Sydney Water before proceeding. (approval to vary connection agreement). Backflow prevention Your plumber should ensure you have adequate backflow prevention. You must comply s Backflow Prevention Policy. This means you must engage a backflow accredited licenced plumber and arrange to install and test a backflow containment device(s) at the property boundary next to the water meter(s) servicing your property. You must also install a tap within five metres of any pre-treatment equipment (eg grease trap) and a backflow prevention device on the inlet side of the tap. To know more about backflow prevention, visit sydneywater.com.au

Minimum pre-treatment requirements for retail food processes Commercial process Seats/beds Minimum pretreatment in floor and in sink bucket traps Cafeteria, canteen (and school hot meals) 1000 L Take-away inc fish and chips, hot chicken 1000 L Charcoal chicken 1000 L Wastesafe only, including school domestic science 1000 L Snack bar coffee lounge hot foods 1000 L Restaurant, food court 1-69 1000 L Restaurant, food court 70-199 1500 L Restaurant, food court 200-399 2000 L Restaurant, food court 400-599 3000 L Restaurant, food court 600-799 4000 L Restaurant, food court 800-1000 5000 L Kitchen hospital, nursing home 1-69 1000 L Kitchen hospital, nursing home 70-199 1500 L Kitchen hospital, nursing home 200-399 2000 L Kitchen hospital, nursing home 400-599 3000 L Kitchen hospital, nursing home 600-799 4000 L Kitchen hospital, nursing home 800-1000 5000 L McDonalds 1500 L 3000 L Pizza Hut 1000 L Function centre 1-69 1000 L Function centre 70-199 1500 L Function centre 200-399 2000 L Function centre 400-599 3000 L Function centre 600-799 4000 L Function centre 800-1000 5000 L

Commercial process Seats/beds Minimum pretreatment in floor and in sink bucket traps Red Rooster 1500 L Delicatessen with hot food < 12 kl/day 1000 L Hungry Jacks 1500 L Supermarket with chicken cooker 1500 L plus grease BBQ wholesale (chicken) 1500 L plus grease BBQ wholesale (pork, duck) 2000 L plus grease BBQ restaurant 2000 L plus grease Wholesale food < 12 kl/day, caterer 1000 L Hotel/motel kitchen 1-69 1000 L Hotel/motel kitchen 70-199 1500 L Hotel/motel kitchen 200-399 2000 L Hotel/motel kitchen 400-599 3000 L Hotel/motel kitchen 600-799 4000 L Hotel/motel kitchen 800-1000 5000 L Ice cream parlour No grease trap Butchers - retail 1000 L Fish (fresh outlet) no cooking Large basket trap with fixed screen and removable basket Chicken (fresh retail) no cooking 1000 L Smallgoods < 12 kl/day maximum 1000 L Wholesale butcher < 12 kl/day maximum 1000 L Bakery retail hot bread - cakes No grease trap Bakery retail pies sausage rolls 1000 L