TROUBLESHOOTING TRACHEOESOPHAGEAL VOICE PROSTHESIS ISSUES



Similar documents
Prosthetic Surgical Voice Restoration (SVR): The role of the speech and language therapist. Royal College of Speech and Language Therapists

TRACHEOSTOMY TUBE PARTS

Rehabilitation after Total Laryngectomy

Shiley Product Guide. Shiley TM XLT Extended-Length Tracheostomy Tubes. Shiley TM Disposable Inner Cannula

Use of stents in esophageal cancer" Hans Gerdes, M.D. Director, GI Endoscopy Unit Memorial Sloan-Kettering Cancer Center

Contraindications: Malign or benign strictures in the upper part of esophagus close to the cricopharyngeal muscle.

Peripherally Inserted Central Catheter (PICC) for Outpatient

III-701 Urinary Catheterization/Bladder Irrigation Original Date: 3/1/1977 Last Review Date: 10/28/2004

Caring for a Tenckhoff Catheter

PICC & Midline Catheters Patient Information Guide

My patient has a feeding tube

Thyroid Eye Disease. Anatomy: There are 6 muscles that move your eye.

PATIENT CONSENT TO PROCEDURE - ROUX-EN-Y GASTRIC BYPASS

CHEST TUBES AND CHEST DRAINAGE SYSTEMS

X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary

PREPARING FOR YOUR STOMA REVERSAL

X-Plain Foley Catheter Male Reference Summary

PATIENT GUIDE. Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL

Dental Care and Chronic Conditions. Respiratory Disease Cardiovascular Disease Diabetes

General Thoracic Surgery ICD9 to ICD10 Crosswalks. C34.11 Malignant neoplasm of upper lobe, right bronchus or lung

LAP-BAND System Adjustment Kit DIRECTIONS FOR USE (DFU)

BOUGIES/DILATORS. Dilators

Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION

Aspira* Pleural Drainage Catheter

CERVICAL MEDIASTINOSCOPY WITH BIOPSY

Understanding your Peripherally Inserted Central Catheter (PICC) Patient Information

Information for people being discharged with a naso-gastric (NG) feeding tube

Weight Loss before Hernia Repair Surgery

Sientra Silicone Gel Breast Implants Quick Facts About Breast Augmentation And Reconstruction

Consent for Treatment/Procedure Laparoscopic Sleeve Gastrectomy

BARD MEDICAL DIVISION UROLOGICAL DRAINAGE. Foley Catheter Care & Maintenance. Patient Education Guide

Endoscopic Management of Strictures and Leaks. Prepared by Aurora D. Pryor, MD Presented by Dana Portenier, MD Duke University Medical Center

Adult Speech-Language Pathology Services in Health Care

Going home with your Tunneled Catheter

Care of Gastrostomy Tubes for Adults with IDD in Community Settings: The Nurse s Role. Lillian Khalil, BSN, RN Volunteers of America, Chesapeake

Biliary Drain. What is a biliary drain?

Care for your child s Central Venous Catheter (CVC)

Interscalene Block. Nancy A. Brown, MD

Urinary Diversion: Ileovesicostomy/Ileal Loop/Colon Loop

Epidural Continuous Infusion. Patient information Leaflet

Nursing college, Second stage Microbiology Dr.Nada Khazal K. Hendi L14: Hospital acquired infection, nosocomial infection

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

Department of Surgery

Quick Facts about Breast Augmentation with IDEAL IMPLANT Saline-filled Breast Implants

Achieving Independence

Application of the Passy-Muir Swallowing and Speaking Valves Julie A. Kobak Director of Clinical Education-Speech

One Lung Ventilation Module (OLV)

Having a Gastric Band

Colocutaneous Fistula. Disclosures

Resection, Reduction, and Revision of Aneurysmal AV Fistulas

Varicose Vein Treatment (Endovenous Ablation of Varicose Veins)

Placement of an indwelling urinary catheter in female dogs

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Understanding Your Hemodialysis Access Options UNDERSTANDING YOUR HEMODIALYSIS ACCESS OPTIONS

Section 4: Your Vascular Access. What is vascular access?

Spinal Cord and Bladder Management Male: Intermittent Catheter

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

Endoluminal Bariatric Revision. Todd David Wilson, MD

Aestheticare Cosmetic Surgery Institute Dr. Ronald E. Moser Rancho Viejo Rd. San Juan Capistrano, CA (800)

PICCs and Midline Catheters

Catheter Care. What you need to know. Jacinta Stewart Continence Nurse

STAY-PUT Nasojejunal Feeding Tubes. Nursing Manual/ Patient Information

Aspira* Peritoneal Drainage Catheter

PICC Catheter for IV Therapy

Breast Augmentation. If you are dissatisfied with your breast size, augmentation surgery is a choice to consider. Breast augmentation can:

Instructions for Use

Procedure -8. Intraosseous Infusion Adult and Pediatric EZIO. Page 1 of 7 APPROVED:

Urinary Indwelling Catheter. The Urinary System

Tunneled Central Venous Catheter (CVC) Placement

METHODS OF BOLUSING THE TRACHEOSTOMY STOMA

Tooth Replacement Options

What is Barrett s esophagus? How does Barrett s esophagus develop?

Hysteroscopy. What is a hysteroscopy? When is this surgery used? How do I prepare for surgery?

Tracheostomy Care at Home

Vaxcel PICCs Valved and Non-Valved. A Patient s Guide

Patient Information. PORT-A-CATH Implantable Venous Access Systems

TREATMENT 1. Control bleeding by applying pressure over wound with Gauze Pads (Surgical Supply-4). 2. Contact Surgeon for laceration repair options.

Breast Reconstruction Frequently Asked Questions

Dept. of Medical Imaging University of Ottawa

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

How do I evaluate my skin condition? What causes sore skin?

N26 Chest Tubes 5/9/2012

PICC/Midclavicular/Midline Catheter

Ventilator Application of the Passy-Muir Valve David A. Muir Course Outline Benefits Review of the Biased Closed Position No Leak Passy-Muir Valves

Breast Implants: Local Complications and Adverse Outcomes

TECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work

Informed Patient Tutorial Copyright 2012 by the American Academy of Orthopaedic Surgeons

NHS FORTH VALLEY Chest Drain Insertion by Seldinger Method (Pigtail drains)

A Patient s Guide to the Calypso System for Breast Cancer Treatment

Chapter 11. Everting skin edges

CUESTA COLLEGE REGISTERED NURSING PROGRAM CRITICAL ELEMENTS

Trouble Shooting. Pump

CATHETER for Hemodialysis

Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters

All About Your Peripherally Inserted Central Catheter (PICC)

Guy s, King s and St Thomas Cancer Centre The Cancer Outpatient Clinic Central venous catheter: Peripherally inserted central catheter

Information for patients who require Foam Sclerotherapy for Varicose Veins.

Inflammation and Healing. Review of Normal Defenses. Review of Normal Capillary Exchange. BIO 375 Pathophysiology

Transcription:

TROUBLESHOOTING TRACHEOESOPHAGEAL VOICE PROSTHESIS ISSUES Teresa H. Lyden And Marc J. Haxer Departments of Speech-Language Pathology and Otolaryngology/Head and Neck Surgery University of Michigan Health System

Tracheoesophageal Speech Air expelled from the lungs into trachea and diverted via silastic prosthesis into esophagus when the stoma is occluded. Results in vibration of the PE segment TEP can occur at time of surgery or as a secondary procedure Prosthesis can be placed at the time of the puncture or at a later time

TE Speech: Patient Selection Patient motivation vs being pressured by family, SLP, surgeon Stable mental and cognitive status Good manual dexterity Good visual acuity Adequate pulmonary support Patent stoma Functional PE segment?

Contraindications to TE Voice: Who Not to Puncture Reduced patient motivation Altered mental status/ compromised cognition of patient Inadequate patient understanding of post-surgical changes in anatomy and mechanics of voice prosthesis. Insufficient manual dexterity and/or visual acuity to care for stoma and prosthesis Significant stenosis of the hypopharynx. Increased pressures within pharyngoesophageal segment Inability to produce TE voice following esophageal insufflation via properly positioned esophageal catheter (the Taub test)

Contraindications to TE Voice: Who Not to Puncture Inadequate pulmonary reserve Hx of COPD, emphysema, pulmonary fibrosis, interstitial lung disease, etc. Inadequate depth and diameter of stoma to accept prosthesis without airway compromise Recurrent Disease Unresolved fistula Bad Tissues Reduced Income Poor or No Insurance Transportation Issues

TE Speech: Primary vs Secondary TEP Primary TEP May allow for feeding through the TEP site (no need for DHT) Patient does not have to undergo secondary procedure/return to OR Migration of the TEP as healing progresses Dilation of the TEP due to movement of catheter May be able to place prosthesis at time of procedure (location specific) Secondary TEP Allows time for healing May promote more stability of TEP Can be done in the clinic (Surgeon specific) May be able to place voice prosthesis at the time of the procedure

TE Speech: Prosthesis Info Brands/Types/Sizes/Method of Insertion InHealth Technologies (Blom Singer) and Atos Medical (Provox) Indwelling and patient changeable/non-indwelling Diameters: 16, 17, 18, 20, 22.5Fr Lengths: 4-20mm, 22mm, 25mm, 28mm Gel Cap, forced entry, and use of a tubed loading system Styles Duckbill (increased resistance) Low pressure (less resistance) Options Large tracheal and/or esophageal flange, increased resistance, custom lengths, altered strap length, yeast resistant

Prosthesis Selection 16Fr. at 1 st fitting Tissue integrity Patient ability to manage Visual Acuity Manual Dexterity Gastric filling TEP location Transportation Stock Availability Cost/Insurance coverage

Prosthesis Insertion Placement generally coincides with clearance for oral intake for primary TEP, 5-7 days for secondary TEP **depending on integrity of tissue Prefer initial placement to be a 16Fr. Prosthesis (14Fr. catheter placement at time of surgery is our preference) Dilate to 16 or 18Fr. Depending on tissue integrity Measure TEP Assess for TE sound production Insert voice prosthesis

Prosthesis Replacement Leaking through Leaking around Poor fit (too long or too short) Reduced or no sound Routine replacement after 6 months

Care and Maintenance of the Voice Prosthesis Indwelling Clean In-Situ Patient changeable Can remove to clean if/as needed Can clean In-Situ (brand dependent) Brush and Flush 2 to 3 times daily as needed Remove mucous away from face of prosthesis

Trouble Shooting

Leaking Through the Voice Prosthesis CAUSE SOLUTION Valve contact with posterior esophageal wall Replace prosthesis to a different type or length Prosthesis length too short for puncture pinching valve Remeasure TEP and fit with appropriate length Valve deterioration Replace voice prosthesis Fungal (yeast) colonization of the valve **most common Nystatin/other antifungal agent and/or use of yeast resistant or dual-valve voice prosthesis Back Pressure Mucous or Food Lodgement Increased resistance prosthesis Cleaning prosthesis in-situ

Yeast Colonization

Care and Maintenance of the Voice Prosthesis: Leaking Through Brush and flush Plug shaft of prosthesis with Q-tip Consume 8 ounces of hot/carbonated beverage Produce loud aah Check for leak; if still leaking, repeat steps If still leaking, can place a plug (if Indwelling) during oral intake

Leaking Around the Voice Prosthesis CAUSE SOLUTION TEP location Allow TEP to close/repuncture Unnecessary dilation of the puncture during initial or routine placement Thin party wall (6mm or less) Incorrect prosthesis length (too long) Poor tissue integrity secondary to radiation, chemoradiation, diabetes, nutritional imbalance, thyroid issues, recurrence Defer dilation or dilate only to size of voice prosthesis Prosthesis selection/custom fit Remeasure TEP/place correct size Prosthesis selection/custom fit, check thyroid levels, manage medical issues, diet changes

Leaking Around: Management Myths/What not to do Electro-cautery to shrink TEP Never insert larger prosthesis or larger tube/catheter to plug the TEP Placement of smaller catheter to allow for TEP stenosis (Temporary Solution-NOT a long term Solution)

Poor or NO TE Sound CAUSE Prosthesis plugged Partial extrusion of prosthesis with closure of TEP PE spasm/hypertonicity Excessive digital pressure during phonation Prosthesis too long SOLUTION Clean prosthesis Remove prosthesis, establish TEP if able, replace prosthesis, secondary TEP if needed Botox injection Patient training on light touch Remeasure TEP-down size prosthesis

Prosthesis Extrusion: Partial or Complete CAUSE Poor Tissue Integrity Prosthesis fit (Tight A/P) Accidental SOLUTION Prosthesis with Large Esophageal and or Tracheal Flange R/O diabetes, malnutrition, low TSH, Disease Remeasure TEP and adjust prosthesis length Train Patient

Poor Visualization of Voice Prosthesis CAUSE SOLUTION Stenosis (small tracheostoma) Silicone laryngectomy tube Silicone stoma button such as a Barton Mayo Button or Lary Button Surgical revision of stoma Migration of TEP Allow TEP to close/repuncture Location of TEP Shelf of tissue Prosthesis selection Allow TEP to close/repuncture

Length of cotton tip = 15mm; width of stoma is approximately 8mm

Gastric Filling CAUSE SOLUTION Increased negative pressure in esophagus during inhalation resulting in inadvertent (prosthesis) valve opening Hypertonicity of PE segment Stricture Excessive respiratory force during phonation Prosthesis with increased resistance Botox injection Dilation Teach easy onset voicing

Granulation Tissue CAUSE SOLUTION Irritation associated with presence of foreign body (prosthesis) Surgical removal ( donutectomy ) Circumferential ( donut of tissue) Unilateral Bilateral Prosthesis fit too tight Reassess fit of prosthesis

Hypertonic Voice CAUSE PE spasm/hypertonicity Excessive digital pressure Partial closure of TEP (related to partial prosthesis dislodgement) Prosthesis failure (worn out) SOLUTION Botox injection Patient training on light touch Remove prosthesis, establish TEP, measure and fit with new prosthesis Replace prosthesis

Objective Insufflation Introduction of air into PE segment prior to or subsequent to formation of TE puncture Determines capability for TE voice Measures pressures within PE segment Aids in assessment of TE voice capability Can be completed transnasally or transtracheally Transnasal method catheter placed 23, 25, or 28 cm along floor of nasopharynx to level of PE segment Continuous airflow from wall source/patient s pulmonary air flow introduced through catheter into PE segment Pressures measured Transtracheal method Length of patient s current voice prosthesis marked on tip end of catheter Catheter inserted into TEP to current prosthesis length Air then introduced into PE segment as in transnasal procedure Pressures measured Above procedures advocated by Taub, Blom, and Lewin over last 40 years

Botox Injection Marking Injection

Botox Injection Voicing to Mark Injection

Botox Injection Marking Injection

Manometry Training aid for clinicians to teach patients how to self-regulate intra tracheal air pressure. Proper airflow control results in better voice quality, less fatigue, and longer duration of the tracheostoma adhesive housing seal Use to check pressure ranges pre and post Botox Pressure Ranges (cm of H2O) 10-25 cm of H2O Excellent/green 26-40 cm of H2O Good/blue 41-120 cm of H2O High

Hypotonic Voice CAUSE SOLUTION Hypotonic PE segment Extended myotomy during TL Repeated dilatations over prolonged period of time Botox Injection Digital pressure Pressure band Adjust diameter of prosthesis Allow time for Botox to wear off

TE Speech: ED Issues Prosthesis extrusion/intrusion If you know where prosthesis is Insert 14Fr. Red Robinson catheter into TEP If unable to insert 14, try insertion of next smallest size Continue until TEP stented with a catheter (#12, 10, or 8) Insert all but 1-3 inches of the catheter Tie a tight knot in the end Tape end of catheter to peristomal skin close to stoma If you do not know where prosthesis is Chest X-ray to locate prosthesis Follow items listed above Prosthesis aspirated Visualize or confirm via X-Ray Review options for removal with attending Insert 14Fr. Red Robinson rubber catheter (repeat steps listed to the left)

Voice Restoration After Free-Flap Reconstruction Voice/quality of voice dependent on type/extent of flap utilized May require increased vocal effort Intensity/quality of voice may be reduced

Final Thoughts NEVER use a larger diameter prosthesis to plug a TEP that is dilating/getting bigger Become familiar with the available products Get Training Both Atos and InHealth offer training courses for their products Seek advice from Local Experts Remember: There is skill required to place and mange a voice prosthesis. Know your limitations