INSTRUCTIONS ELECTROSURGICAL UNIT WARNING



Similar documents
INSTRUCTIONS ELECTROSURGICAL UNIT PSD-30

INFRARED QUARTZ WALL HEATER

Portable Air Conditioner

How To Use A Power Supply Unit (Upu)

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Safety, Operation and Maintenance Manual with Parts List

3000W Power Inverter

User s Manual AURORA 1.2K/2.2K

EKOS Cart. Instructions for Use

MAINTENANCE & TROUBLESHOOTING

Meaco 30L and Meaco 40L dehumidifier instruction manual

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

National- Spencer Inc.

TIG INVERTER INSTRUCTION MANUAL

Instruction manual for Firstline FCS12000CH

SMD Rework Station TABLE OF CONTENTS

Operating Instructions Split System Air Conditioner

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

BeoLab 7-1 BeoLab 7-2. Guide

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

PowlVac Vacuum Integrity Tester

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

San josé OWNER S MANUAL

Tone Hammer 500. Owners Manual. Manual Version 1.0

15GAL STEEL OIL DRAIN WITH 110V PUMP

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

- 2 - IMPORTANT SAFETY REMINDERS

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Battery Power Inverters

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

AutoRanging Digital MultiMeter

2-SLICE COOL TOUCH TOASTER

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Operating instructions in the back. PD1020L

Installation and safety instructions for AC/DC built-in devices

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Split Type Room Air Conditioner. KSWM units

Dehumidifier Users manual. For Models: DH45S DH65S

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

24 Wide Screen LED Monitor with HDMI

Online UPS. PowerWalker VFI 1000R/1U

POWER TO GET THE JOB DONE

Achat 115MA full-range speaker. user manual

100 Series Maxi Internal Filters. Instruction Manual

Ground Resistance Clamp On Tester

Doorbell Intercom Security System

CARING FOR YOUR WATER HEATER

Mini multi-purpose sewing machine

4.3-inch Back-Up Camera

3M Wrist Strap and Footwear Tester 740. User s Guide

STEREO PREAMPLIFIER INSTRUCTIONS FOR USE

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

Manual Ranging MultiMeter

Auto Feed Screwdriver

400 Amp Rechargeable Jump Start System RAC-HP082

12. Inspection and Maintenance

Congratulations! Thank you!

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Model 1756 Test Lead Kit

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

TOA 900 SERIES II MIXER POWER AMPLIFIER

How To Use A Cdm250 Digital Multimeter

Operating Instructions Air Conditioner

Getting started with

CHARGING SYSTEMS INTERNATIONAL

Reverse Cycle Inverter Split System Air Conditioner

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Contact Details. Please note that some of the contact details on this PDF document may not be current.

64-CHANNEL INTEGRATED AMPLIFIER

WSD130 SOLDERING STATION

Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS

120Volt 60-70A ARC WELDER Rev

Installation and Operating Instructions (for chargers shown below)

FC6 FOOT CONTROLLER OWNER S MANUAL

esata External Storage

User manual. Videomatic VERDE MF

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Power supply unit Model: PAC-SC50KUA

User s Manual Before using the inverter, you need to read and save the safety instructions.

Gemini II. Subwoofer System OWNERS MANUAL

HOME THEATER SYSTEM. Instruction Manual. Model ASR150. Please read the instruction manual carefully before using your unit.

350, 500, 650 and 1000 MODELS

V94 BULK TAPE DEGAUSSER

VACUUM CLEANER INSTRUCTION MANUAL

USER S GUIDE. User s Guide Aaron 2250

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

High-output, temperature controlled soldering station. Instruction Manual

Transcription:

INSTRUCTIONS ELECTROSURGICAL UNIT WARNING The user of this equipment should be thoroughly trained in the applicable procedure. Furthermore, failure to read and thoroughly understand the contents of this instruction manual may result in serious injury to the patient and/or user. It is essential to follow the instructions contained in this and other manuals which pertain to any equipment and accessories used in conjunction with this equipment. Possible injuries related to endoscopic procedures may include electric shock, explosion, burns, perforation, hemorrhage, etc. Failure to follow these instructions may also result in damage to and/or malfunction of this equipment. CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician.

IMPORTANT The Olympus Electrosurgical Unit PSD-10 has been designed for endoscopic electrosurgery (coagulation, polypectomy, sphincterotomy, etc.) in conjunction with Olympus fiberscopes that are applicable to electrosurgery, Olympus electrosurgical accessories and light sources. Do not use the equipment for any purpose other than its intended use. Please read this entire manual carefully before using the equipment in order to acquaint yourself with the proper care and handling of your new electrosurgical unit. Then prepare and inspect the equipment following these instructions. Safety precautions must be exercised when handling electrical equipment to prevent operator/ patient shock, fire hazard and equipment damage. If you have any questions concerning the material contained in this manual or concerning the operation or safety of the equipment, please contact your Olympus representative or the nearest Olympus Service Center.

CONTENTS 1 FEATURES AND MAIN SPEClFlCATlONS 1 1-1 Features 1-2 Main Specifications 1-3 Safety Precautions 1 2 5 2 3 4 DESCRIPTION OF CONTROLS 7 CONSTRUCTION 9 STANDARD SET 10 5 PREPARATION FOR USE 5-1 Installation of PSD-10 5-2 Connection to AC Power 5-3 Connection of Footswitch 5-4 Connection of S-P Cord 11 11 11 12 12 6 7 8 INSPECTION OF ELECTROSURGICAL SYSTEM 13 ENDOSCOPIC ELECTROSURGERY 17 7-1 Precautions against Patient/Operator Burns 17 7-2 Setup of Patient-plate 18 7-3 Electrosurgery 19 7-4 After Operation 21 CARE AND STORAGE 22 8-1 Care After Use 22 8-2 Storage 22 9 MAINTENANCE 23 9-1 Replacement of Fuse 23 9-2 Cleaning of Ventilation Grills 23 9-3 Periodic Inspection 23 10 ELECTROSURGICAL SYSTEM CHART 24

1 FEATURES AND MAIN SPECIFICATIONS 1-1 Features 1. Simplified pre-procedural test, using a Check Lead, of the power output of the PSD-10 alone as well as that of the entire electrosurgical system including the endoscope and endoscopic electrodes. Test results confirmed by TEST OK or FAULT indicator lights on the front panel. 2. Push-button selection of CUT, COAG or BLEND current. Output power is controlled by a single-pedal footswitch. 3. The connection monitor circuit detects loose or inadvertent misconnection of cords or broken wires in the S-P cord (Safety cord and Patient cord). If any irregularity is present, the monitor activates an alarm and inhibits output (current is not delivered when the footswitch is depressed) to ensure safety of the procedure. 4. The feedback ratio monitor scans the entire circuit when the footswitch is depressed. If excessive leakage current is present, the output is inhibited to ensure safety of the procedure. 5. Flat switches and display panel can be easily wiped clean. 6. Compact, lightweight and portable.

1-2 Main Specifications Applicability Applicable field Compatible endoscopes Endoscopic electrosurgery Olympus fiberscopes suitable for electrosurgery Waveform CUT BLEND COAG Radio-frequency Current Output Output (watts) Max. rated output (Load: 5OO CUT: 80 W BLEND: 60W COAG: 40 W Output setting Max. open-curcuit output voltage: less than 1800 Vp-p Type Flat switches Output Adjustment Range 0.5 5.0 Steps 10 steps with 0.5 increment from 0.5 to 5.0. Output Selection of output current Flat switches (CUT, BLEND or COAG) Current control Footswitch

Monitors Connection Output check Connection monitor Feedback ratio monitor S-P cord A-cord Check lead Footswitch Type of protection against electric shock When the Check Lead is connected and the footswitch depressed, either the OK or FAULT light will come on. Checks the PSD-10 or the entire electrosurgical system. The entire electrosurgical system cannot be tested when using PSD-10 in combination with CD-3U/L or CD-40/L. Detects defective connections of cords and broken wires in the S-P cord, and activates: A warning light (P-cord or S-cord symbol), a warning buzzer, and inhibits output. Computes return current/delivered current ratio. If the ratio is less than a preset value, it inhibits output. Plug-in (PSD-10) and screw-on (P-plate and endoscope) Plug-in Plug-in Screw-on Class I equipment Classification Degree of protection Type BF (Body Floating) equipment (Electro- against electric shock medical equipment) Degree of protection The PSD-10 should never be used where there is a risk against explosion of flammable gases. Other Defibrillator-protected equipment

Operating Environment Power requirements Voltage: 110, 120, 220, 240 V (a.c.) Frequency: 50/60 Hz Input: 4 A (110, 120V), 2A (220, 240V) Voltage fluctuation: Within ±10 % Ambient temperature 10 40 C (50 104ºF) Relative humidity 30 75% Atmospheric pressure 700 1060hPa (700 1060 mbar) Dimensions & Weight 290 mm (W) x 162 mm (H) x 300 mm (D) max., 8 kg or 17.6 lb (PSD-10 main body)

1-3 Safety Precautions The PSD-10 should be used only in a medical facility under the supervision of a trained physician. The PSD-10 is designed (floating) to function integrally with insulated patient attachments (active electrode and patient plate) to prevent operator/patient shock. To prevent shocks which may be caused by leakage current from other apparatus applied to the patient, endoscopes and cameras used with the PSD-10 should not be grounded. The endoscopist and his assistant should wear rubber handgloves as an added precaution. When using a camera (except the SC16-10) an insulating hood should be attached to the camera s eyepiece. The enclosure of the PSD-10 must be grounded securely and effectively. Do not defeat the line cord ground connection. The PSD-10 should never be applied to the heart directly. Never install and operate the PSD-10 where there is a risk of flammable gases. Should any irregularity or abnormality be suspected during operation, immediately stop the use of instrument and turn OFF the power switch. Keep liquids away from all electrical equipment to prevent operator shock and instrument damage. Do not use the PSD-10 if spilled fluids have entered the unit. Please investigate the possibility of electronic interference for other electromedical equipment in conjunction with the PSD-10 prior to use. Do not install the patient plate adjacently to an artificial bone (metal), etc.

Keep adequately away from cords of electric scalpel (scalpel holder, scalpel cord and patient plate cord), scalpel main body and cords, main body of other electromedical equipment. Do not loop cords of electric scalpel (scalpel holder, scalpel cord and patient plate cord). Do not contact these cords with the patient or metallic portion of an operating table, etc. The PSD-10 should not be used in conjunction with electrical apparatus whose safety against leakage current is not guaranteed. Radio-frequency and spark discharge noise may adversely affect other electro-medical equipment being used in the proximity. Do not apply the electric scalpel to the patient who has a pacemaker in his body. The use of a radio-frequency noise filter in monitor electrode lines may reduce interference. Patient monitor electrodes must be placed as far away as possible from the operative field. Needle type electrodes should not be used as they increase the risk of burns. To prevent instrument damage, the active electrode and the patient plate should not be short-circuited. Do not activate the electrode for an extended time when it is not touching the target tissue. The PSD-10 should be used in accordance with the operating environment specified in 1 2 Main Specifications; otherwise improper performance, compromised safety or instrument damage may result. Repairs should be carried out only by an Olympus Service Center.

2 DESCRIPTION OF CONTROLS Selected Current Indicators Light when the switch under the indicator is pressed. Output Indicators Light to indicate the selected current (CUT, BLEND or COAG) is being delivered when the footswitch is depressed. Output Test Indicators Indicate normal or abnormal test conditions. Defective Connection Indicators Light to indicate defective connection of cords or broken wire in S-P cord. Current Selector Switches Output Level Indicators Light when the switch under the indicator is pressed. Output Adjustment Switches Output level from 0.5 to 5.0 (with 0.5 increment) is selected. Power Switch Footswitch Connector TEST Connector Accepts the smaller plug of Check Lead (for test). Patient-plate Connector Accepts S-P cord. Active Cord Connector Accepts A-cord (for electrosurgery) or the larger (clip-tipped) plug of Check Lead (for test).

Main Body & Components Cord Hanger Carrying Handle Ventilation Grill (rear) (front) Power Cord Connector (Appliance Inlet) Ventilation Grills Ratings Plate Fuse Holder TEST plug Terminal PATIENT plug Check Lead S-P Cord S-cord (to endoscope) ACTIVE plug (to Patient-plate) Patient-plate P-cord Pedal Footswitch FOOT SW. plug S-P Cord for disposable patient plate (optional) Power Cord

3 CONSTRUCTION Panel Control Circuit Panel Display Circuit OsciIlator Waveform Generating Circuit Control Circuit Amplifier Comparator Endoscope Footswitch When the footswitch is depressed, active current (IA) flows through the A-cord. Return current (IP) flowing through the patient plate to the P-cord connector is monitored. The feedback ratio IP/IA is computed. If the ratio is more than a preset value, the feedback ratio monitor determines that excessive current leakage is not present in the circuitry and allows the selected current to flow. The current stops when the footswitch is released. Waveform and output level can be selected by push-button switches. Patient-plate (neutral electrode) Active electrode Patient Body cavity

4 STANDARD SET Please check each item in the set against the list of standard components below. Contact Olympus if there are any missing or defective parts. Electrosurgical Unit PSD-10 1 Check Lead (MB-576) 1 S-P Cord (MB-575) 1 Fuses (spare) 2 Patient-plate (MB-574) 1 Vinyl Dust Cover 1 Footswitch (MB-585 or MB-399). 1 Power Cord 1

5 PREPARATION FOR USE 5-1 Installation of PSD-10 5-2 Connection to AC Power Also refer to the instruction manuals provided with the endoscope, electrosurgical accessories and light source, as well as the Radio-frequency Cutting and Coagulation in Endoscopic Use booklet and related literature. Check that all safety precautions described in Section 1 3 are met. Place the PSD-10 on a stable surface in a horizontal position. Ventilation must not be obstructed. Carts and stands must be of adequate size and strength to support load. Do not place in a vertical position, such as on the ventilation grill on the side panel. Make sure the power switch is in the OFF position. Power switch should be in the OFF position. Ratings plate Connect the power cord to a properly grounded HOSPITAL GRADE receptacle (or wall mains outlet with grounding contact) that meets the input requirements indicated on the ratings plate on the rear panel. Use only the supplied power cord. Do not use a 3-pin to 2-pin adapter or a cable tap. Connect the power cord securely to prevent accidental disconnection during procedure. The cord should not be sharply bent, twisted or crushed. Power cord Power plug Hospital grade receptacle with grounding contact If an additional protective earth is required to guard against electric shock which may be caused by trouble of the protective earth conductor: Screw a suitable lead wire firmly to the additional protective earth terminal provided on the rear panel of the electrosurgical unit (PSD-10). Connect the other end of the lead wire to the earth terminal facility of the room.

5-3 Connection of Footswitch Connect the footswitch to the FOOT SW. connector on the PSD-10, with the red positioning dot on the plug facing upward. Fully tighten the clamping ring on the plug by turning clockwise. Red mark 5-4 Connection of S-P Cord Connect the S-P cord to the PATIENT connector on the PSD-10, with the red dot facing upward. Push the plug until it is locked in place. Red mark P-cord connector Connect the P-cord connector to the Patient-plate. Fully tighten the clamping Terminal ring. S-cord connector Connect the S-cord to the endoscope (S-cord connector mounted on the light guide connector), which has been plugged in the output socket of the light source. Fully tighten the clamping ring. Patientplate S-cord connector The alarm will be activated when the power switch is turned on, if above mount connections (Steps through are defective. Disposable Lever patient plate In case a disposable patient plate (Scotchplate #1149, 3M) is being used: Lift the lock lever of the special S-P cord (MB-583, optional) and insert the terminal of the patient plate into the port. Press the lever back down to secure plate. Clamp Terminal Connection of disposable patient plate

6 INSPECTION OF ELECTROSURGICAL SYSTEM 1 Power Feeding Turn ON the power switch. The power indicator and LED (Light-Emitting Diode) indicators on the front panel will light and the cooling fan will be heard. If the unit fails to turn on, inspect the power cord connection. Turn on power switch.

2 Output Check 1 (PSD-10 alone) The Check Lead plugs are at an extremely high potential when the footswitch is depressed. DO NOT TOUCH! Severe burns may result. Connect the Check Lead to the TEST connector and to the ACTIVE connector on the PSD-10, by pushing each plug fully into the connector. Check Lead CUT indicator lights. Depress the footswitch for approximately 1 second (until the output tone ceases to sound). Make sure the CUT output indicator (yellow) lights and the TEST OK light (green) comes on after the output tone has stopped. The TEST FAULT light (red) may come on if the pedal is released before the output tone stops or if the allowable voltage fluctuation range is exceeded. The FAULT light comes on: if the footswitch is depressed when the WARNING light is glowing red. Re-connect the S-P cord correctly and repeat above procedure. (If the red WARNING light fails to go out, consult an Olympus service center.) Do not touch the Patient-plate; burns may occur. Disconnect the Check Lead from the PSD-10. OK indicator should light.

3 Output Check 2 (Electrosurgical system) Active plug Clip After proper operation of the PSD-10 has been confirmed by Output Check 1, insert the electrosurgical accessory into the endoscope and proceed with the following steps. The entire electrosurgical system cannot be tested when using PSD-10 in combination with CD-3U/L or CD-4U/L. Be sure to perform the Output Check 1 for the PSD-10 to ensure the proper connection of the system. Electrode wire Endoscope Attach spring-loaded clip to electrode wire. SD-handel Light source S-P cord Connect the A-cord to the PSD-10 (ACTIVE connector) and to the electrosurgical accessory (A-cord plug on SD-handle). Only Olympus A-cord MA-255 is compatible with this equipment. Push each end of the A-cord until a click is felt and heard. Connect the smaller plug of the Check Lead to the PSD-10 TEST connector. Connect the larger plug (spring-loaded clip) to the electrode tip/snare wire which is protruding out of the endoscope. Before connection, wipe the clip clean with gauze dampened with alcohol. When attaching the clip to the wire, be careful not to deform or damage the wire (snare, loop, etc.) A-cord Check Lead Footswitch S-cord P-cord Patientplate Depress the footswitch and ascertain that the TEST OK light (green) comes on. If the TEST FAULT light (red) comes on: a. Connection between the A-cord and the electrosurgical accessory is defective. b. Wire is broken in the above line, or c. The electrode tip is in contact with the metal portion of the endoscope tip. Electrode wire Do not touch the Patient-plate; burns may occur. Assembled electrosurgical system (for test) After performing this check, disconnect the Check Lead and the A-cord from the PSD-10.

4 Checking the Output Adjustment Switches Press a given output adjustment switch (0.5 to 5.0): the indicator above the switch should light. 5 Checking the Current Selector Switches Press a given current selector switch: the waveform pattern above the switch should light. 6 Checking the Connection Monitor Connection between S-cord and endoscope Loosen the clamping ring on the S-cord connector. Check that: a. S-cord indicator (red) lights and the warning tone (intermittent) sounds simultaneously. b. Depress the footswitch. Make sure output indicators and output tone are not activated. Re-tighten the clamping ring to resume correct connection. Connection between P-cord and Patient-plate Loosen the clamping ring on the Patient-plate connector. Check that: a. The P-cord indicator (red) lights and the warning tone sounds simultaneously. b. Depress the footswitch. Make sure output indicators and output tone are not activated. Loosen clamping ring and check Re-tighten the clamping ring.

7 ENDOSCOPIC ELECTROSURGERY This section outlines a general procedure for endoscopic electrosurgery. The endoscopist should evaluate the clinical factors involved and decide on the specific details of the procedure. 7-1 Precautions against Patient/Operator Burns To prevent accidental burns, attention must be paid to the following points. The patient should not come into contact with grounded metal objects (e.g., iron bar of bed, external surface of an appliance). Patient skin surfaces should not touch each other (e.g., bare arm and chest). Patient s clothes must be dry. Patient monitoring electrodes should be placed as far away from the operative field as possible. The A-cord or S-P cord should not touch or lay on the patient. When using lower GI endoscopes, intestinal gas should be replaced with nonflammable gas (CO2, etc.) before operation. The operator and assistant should wear rubber handgloves.

7-2 Setup of Patient-plate Incomplete attachment of the Patient-plate may cause patient burns. Put gauze pads which are slightly larger than the Patient-plate and moistened with physiological saline or conductive paste (e.g., Conductive Gel #1103, 3M) on the Patient-plate. Attach it to the patient s thigh or calf with the fastening band, or lay it under the hip. Wet gauze pads with saline or conductive paste. The gauze pads should be wet throughout the operation. If they become dry, wet again. Do not apply the Patient-plate to a hairy or cicatrized skin area. Do not deform the Patient-plate. The entire surface of the Patient-plate should be in contact with the patient. When a disposable patient plate (#1149, 3M) is being used: Remove the protective paper and attach the plate to the patient. The plate may become detached easily unless thoroughly dry. Avoid a hairy or cicatrized skin area. Do not wrinkle the plate. with the patient s skin. Its entire surface should be in direct contact Entire surface of plate should be in direct contact with patient s skin. The plate should not be reused.

7-3 Electrosurgery The type of output current and its intensity must be determined by reference to related papers and based on one s own experience. 1 Power Feeding Turn ON the power switch. 2 Selection of Current Press the desired current selector switch (CUT, BLEND or COAG). If none of the current selector switches are pressed, none of the current indicators above them will be lit; instead, the warning tone sounds and current will not be delivered when the footswitch is depressed. If more than two current selector switches are pressed, the current indicators corresponding to the pressed switches will light: in this case also, the warning tone sounds and the output is inhibited. 3 Selection of Output Level Press the desired output adjustment switch. If none of the output adjustment switches are pressed, none of the LEVEL indicators above them will be lit; instead, the warning tone sounds and current will not be delivered when the footswitch is depressed. If more than two output adjustment switches are pressed, the LEVEL indicators above them corresponding to the pressed switches will light; in this case also, the warning tone sounds and the output is inhibited.

SD-handle A-cord 4 Connection of A-Cord Connect the A-cord to the PSD-10 and to the electrosurgical accessory. Only Olympus A-cord MA-255 is compatible with this equipment. As an added precaution, connect to the accessory as the final step before depressing the footswitch. 5 Operation Depress the footswitch and operate on the tissue. Attach A-cord as the final step before depressing the footswitch. If the electrosurgical procedure is not progressing as expected, do not increase the power hastily. Inspect the whole circuitry again (connection of cords, contact of Patient-plate, etc.) for any abnormality. If the output tone sounds and the output indicator lights when the footswitch is not operated, immediately stop the use of the equipment and turn OFF the power switch. If the output tone does not sound and the output indicator does not light, it may be because some abnormality is detected by the monitor and the output is inhibited. The table below lists some possible remedies. (For detailed discussion refer to the Radio-frequency Cutting and Coagulation in Endoscopic Use booklet.) Symptom Metal portion of endoscope s distal end is touching the target tissue. The metal portion above is indirectly touching the tissue via fluids. The metal portion is touching electrode tip. Remedy Move endoscope tip back from the tissue. Suction fluids from around the tissue and move endoscope tip back from the tissue. Move electrode tip well away from the tissue and bring electrode tip into clear view.

7-4 After Operation Turn OFF the power switch. Disconnect the power plug from the hospital grade receptacle if the PSD-10 is not going to be sued for an extended period.

8 CARE AND STORAGE 8-1 Care After Use Disconnect the A-cord, S-P cord and footswitch from the PSD-10. Lightly wipe all surfaces using a soft cloth or gauze sponge. If dirt remains, moisten the gauze with disinfectant ethanol and wipe again. Wipe cords clean. For disinfection, wipe with a gauze sponge moistened with disinfectant ethanol or 2% glutaraldehyde solution. If a glutaraldehyde solution is used, wipe again with disinfectant ethanol to remove all residue. Avoid touching the electrical contacts and connectors: poor electrical contact will result. To prevent scratches, do not use harsh or abrasive wiping material. Surfaces must be thoroughly dry before use. Wipe panel clean. 8-2 Storage Band Wind the power cord around the hanger on the rear of the PSD-10. Place the PSD-10 on a stable surface in the horizontal position. Put on the vinyl dust cover. Storage area must be maintained at normal temperature and humidity, and away from water splashes. Do not subject to heavy blows or impacts. Put on the vinyl cover.

9 MAINTENANCE 9-1 Replacement of Fuse If the PSD-10 ceases to operate and the malfunction cannot be isolated, check the fuse holder on the rear of the PSD-10 after unplugging the power cord from the hospital grade receptacle. Be sure to unplug the power cord from the AC mains. Turn off power switch and unplug from hospital grade receptacle. If the fuse is found to have blown, replace it with a new fuse making sure that the requirement for supply voltage fluctuation in 1-2 Main Specifications, is met. Fuse holder In case the spare fuse has been expended, use a commercially available equivalent (rated value is indicated near the fuse holder). After replacement, if the new fuse blows again, contact an Olympus service center. 9-2 Cleaning of Ventilation Grills If dust and dirt have collected on the ventilation grills, clean using a vacuum cleaner. 9-3 Periodic Inspection Periodically inspect the PSD-10 following the procedure in Section 6 IN- SPECTION. lf any irregularity or abnormality is suspected, contact your Olympus representative. Repair must be made by an authorized Olympus service center, and should not be attempted by non-olympus service personnel.

10 ELECTROSURGICAL SYSTEM CHART Adapter SC16-10 OES Camera Fiberscope OTV-F2 TV System Light Source S-P Cord MB-575 Patient-plate MB-574 CLE-10 CLE-F10 CLV-10 CLV-F10 CLV-U20 Electrosurgical Unit PSD-10 S-P Cord for Disposable (Disposable Patient-Plate) Patient-plate MB-583 Patient-plate No. 1149 (3M) Foot Release MB-332 SNARE A-Cord MA-255 SD-Handle MA-254 Check Lead MB-576 or Footswitch MB-585 Footswitch MB-399

San-Ei Building, 22-2, Nishi Shinjuku 1-chome, Shinjuku-ku, Tokyo, Japan (Premises/Goods delivery) Wendenstrasse 14-16, D-20097 Hamburg, Germany. (Letters) Postfach 10 49 08, D-20034 Hamburg, Germany. 4 Nevada Drive, Lake Success, N.Y. 11042-1179, U.S.A. KeyMed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, United Kingdom BLK 211, Henderson Road No. 13-03, Henderson Industrial Park, Singapore 0315 The design of the product is under constant review and whilst every effort is made to keep this manual up to date, the right is reserved to change specifications and equipment at any time without prior notice. X5574 01 001 This publication is printed on recycled paper. Printed in Japan 9408 M 02