flueless gas fires & stoves



Similar documents
Quality Gas and Electric Fires

The world s most efficient flued gas fires

ELECTRIC I FIRES. CW036_Electric_brochure_art.indd 1

Heating and cooling a home in Australia amounts to around

The growing popularity of Gas Fireplaces has created a demand for an ever increasing array of styles and sizes to fit every decor and budget.

Handcrafted with passion

GAS STOVES woo GAS STOVES

the most efficient wood burning stove in the world

E L E C T R I C I FIRES

A new range of clean burning multifuel stoves

MODELS BR517R & BR517S (G.C & ) & ULTIMATE TURBOCHIM* & SUPERFLAME RF* Rear & Side Fan Flued Inset Gas Fires

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

The. fires collection. supplement brochure

Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts

Fireplace Xtrordinair Electric Fireplace Inserts

OUR CLEANBURN RANGE OF STOVES BRINGS THE COOL, MINIMALIST ELEGANCE OF SIMPLE SCANDINAVIAN STYLE INTO YOUR HOME.

OPEN GAS FIRES. Photograph courtesy of Matakana Cinema

The Savannah Steel Series Wood Burning Stoves and Inserts

INSTALLATION & USER INSTRUCTIONS

Commissioning of Heat Producing Appliances Burning Solid Fuel

Gas-Fired, Residential Storage Type Water Heaters

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

Exé page couverture Anglais.qxp 05/05/ :32 Page 1 T H E D U T Y O F Q U A L I T Y CAST IRON FIREBOXES

From its humble origins over 25 years ago on a farm near Dartmoor, renowned for its cold winters, Yeoman has grown to become one of the UK s leading

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

From its humble origins over 25 years ago on a farm near Dartmoor, renowned for its cold winters, Yeoman has grown to become one of the UK s leading

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

INSTANTANEOUS GAS FIRED

556/586 NEW NEW. One step closer to the fire.

Installation Instructions

Heating and cooling. Insulation. Quick facts on insulation:

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Across America. Wood & Coal Brochure

The space saving solution.

Condensation. Some Causes, Some Advice

Baxi Combi 80e & 105e

1 DESCRIPTION OF THE APPLIANCE

STOVES & INSERTS PELLET. PELLET STOVES & INSERTS. woo

Carbon monoxide. General information

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

The Engineer s Guide to Efficiency Requirements for Wood Burning Appliances

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

Technical Bulletin 005(A) Developed with Communities and Local Government

PROFESSIONAL AUDIO VISUAL. the ultimate in luxury, waterproof and in-wall televisions

Energy Efficient Windows

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

550,000. Westfield Close, BATH

Highly Efficient Glass-Fronted Gas Fires Issue 5. A World of heat you can rely on

Gas Fireplaces FEATURING

INSERTS GAS FIREPLACE. GAS FIREPLACE INSERTS

SRP Pricelist 2015 Including VAT. Stoves for every home

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

SYSTEM BOILER ESTIMATES!

Product Finishes Guide. More for your door than any other brand.

B u y e r s Guide Natural Gas Hearth Pro d u c t s

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Fire Standards & Regulations Are you confused?

Troubleshooting Draft Problems in Chimneys

HEAVY DUTY STORAGE GAS

Permanent Ventilators (for the Supply of Combustion

Ravelli Camino Insert Wood Pellet Burning Heater. Wood Pellet Fire Installation Specifications. Safety testing of the

TECHNICAL DESCRIPTION

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

FIRES WITHOUT COMPROMISE EXCEPTIONAL FIRES JETMASTER INSET STOVE. Installation, Operating and Servicing Instructions JETMASTER MK6

Stove-boiler for solid fuels KW Directions for use and assembling

Energy Performance Certificate

Gas appliances. Get them checked Keep them safe. The problem

Natural Gas Safety. What You Need to Know

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Having a gas appliance installed or serviced? Doing home improvements?

Mission 7: Saving Energy

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional

Energy Saving Fact Sheet Boilers

This brochure is a guide on how to use your wood heater to maximise the heat obtained from your wood and reduce woodsmoke pollution.

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Housing Services Guidance for tackling condensation, damp and mould in your home

Building Condition Assessment Report

San josé OWNER S MANUAL

UDSA - UDSBD unit heater

Module 2.2. Heat transfer mechanisms

Can you design a frameless shower enclosure that doesn't leak?

The ultimate in contemporary luxury. the range HOMES MAGAZINE

woodburning stoves Bronpi Calefaccion SL

Rainwater Harvesting

because it s personal

Keggomax CM Reflux Still

Faber Collection 2013

Saffron Square (Keats) Unit 6.05 apt 36

Cast Iron Gas & Electric Stoves

Fuel and Energy Conversion and Equivalence Chart

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

healthy homes assessment

Chimneys in Thatched Properties

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE

Transcription:

Made in the UK flueless gas fires & stoves Latitude 4500 with satin trim

Conventionally flued fires lose most of their heat up the chimney. Burley flueless gas fires are designed to operate without a flue or chimney. This means that all the gas is used to heat your room not the environment. Burley flueless gas fires boast 100% efficiency and therefore significantly reduce your fuel bill. 4500 with contrast trim Latitude The Latitude, featured on the front cover, is the latest, exciting addition to the range. Its stunning sleek design makes it a perfect centrepiece for contemporary living areas. The Latitude is extremely slim in design which means that it can be fitted on a flat wall without being recessed. Choose between a plain fuelbed or a layer of white chips. Satin trim Minimum room size 30m 3 Natural Gas only 2 Orbital trim shown with white chips option

Ambience & Esteem stoves Handsome cast aluminium stoves with the classic good looks and homeliness of traditional wood stoves but without the inefficiency or mess of a chimney or flued fire. Esteem 4231 log / 4221 coal Minimum room size 30m 3 100% EFFICIENT 3 Ambience 4121 Minimum room size 40m 3

Perception The Perception, with realistic hand-painted pebbles and solid cast front, makes a striking impression in both traditional and contemporary surroundings. Inset into a standard fireplace opening or simply freestand against a flat wall. Minimum room size 30m 3 4260 / 4260-R 4

4267 / 4267R Minimum room size 30m 3 100% EFFICIENT 5 4264 / 4264-R

Environ This established best seller offers one contemporary and four traditional models, all of which combine fine styling with 100% efficiency. Both the Environ and the Perception will freestand against a flat wall or inset into a standard fireplace opening. 4247 / 4247-R 100% EFFICIENT 6 4242 / 4242-R

4240 / 4240-R Minimum room size 30m 3 4248 / 4248-R 4244 / 4244-R 7

fixed flueless gas fires how do they work? Introduction Burley introduced fixed flueless gas fires to Britain in 1999. Although the concept is relatively new in this country, fixed flueless gas fires have a long established history in Japan (where there are 40 million), the United States (approximately 20 million) and Australia. Fixed flueless gas fires give a combination of convenience, efficiency and safety which flued fires can never equal. We have entered an era of spiralling gas prices, gas shortages and global warming. It is short sighted to continue wasting energy at such a rate when there is an alternative product which is superior to flued fires in so many ways. Efficiency Most of the heat from an open flued gas fire or solid fuel fire goes straight up the chimney. By comparison 100% of the heat generated by a flueless gas fire goes to heating the room. Tests commissioned by Burley compared a 2.5kW flueless gas fire (Burley Environ), a typical 6kW inset flued gas fire (quoted efficiency 59%), a decorative flued gas fire and a 2kW electric fire. These tests, in the living room of a detached house, showed that the flueless gas fire produced over 3 times more heat per kilowatt than the flued gas fire and over 12 times more heat than the decorative gas fire. In other words the flued gas fire lost over 70% of the heat up the chimney and the decorative fire lost over 90%. If the 15 million flued gas fires in Britain were replaced by flueless fires, the country would save around 23,500,000,000 kilowatts of gas every year (costing 1,600,000,000) which in turn would reduce carbon dioxide emissions by over 4,200,000 tonnes every year. Temperature rise in room 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 Time vs Temperature rise in room 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Time in minutes 2.5kW Flueless gas fire 2kW Electric fire 6kW flued gas fire 7kW decorative gas fire Source: http://cdiac.esd.ornl.gov/pns/faq Safety As Burley s flueless gas fires do not rely on a chimney, they provide an unsurpassed level of safety to which flued fires can only aspire. Flues and chimneys can become blocked or adversely affected by down-draughts. Burley flueless gas fires are designed to burn the gas extremely cleanly without a flue. The burnt gases are then passed through a catalytic converter. Every Burley flueless gas fire has an oxygen depletion sensor which constantly monitors the air quality in the room. If the level of oxygen drops by just 1.5%, the fire automatically shuts down. To prevent rubbish being thrown onto the fire and to ensure absolute clean burning, Burley fit a ceramic glass front to every fire. Burley s production method is unique. Every flueless gas fire we have ever made has been bench run for 30 minutes, during which time we monitor numerous combustion and safety criteria. Burley s rigid test criteria for combustion are four times stricter than the European standards. 8

Movement of air through a house with a flueless fire Movement of air through a house with a chimney Air movement Flueless fires gently dissipate heat throughout the entire house. A small air vent regulates air into the room which is being heated. This heated air dissipates away from the fire and circulates around the house. A chimney or flued fire, by comparison, draws a huge amount of air from around your house. This is warm air (that you have paid to heat) which is replaced by cold air leaking in through windows and doors. Catalytic converters All Burley flueless gas fires incorporate a catalytic converter. This is a honeycomb which is coated with rare metals. Oxygen sticks to the coating. If a carbon monoxide molecule meets it, the oxygen converts the carbon monoxide to carbon dioxide (which is harmless and is present in fresh air). Burley has NEVER had a catalytic converter fail or need replacing. All Burley appliances are CE marked by international test houses. One of the tests that the fires must pass is to have the catalytic converter removed. In this condition it must still pass all the strict combustion tests. Convenience A flueless gas fire can be fitted in minutes rather than several hours. It is an extremely simple and problem free operation provided the Gas Safe registered fitter follows the installation instructions. If it is to go in an open chimney, then the flue must be blocked. Apart from that the fire just needs connecting and testing, and the air vent fitting. When fitting a flueless fire, it does not need to be sealed to the fireplace opening. Flueless gas fires do not have to be installed on an outside wall. As no flue is required, thousands of pounds can be saved by not building a new chimney or restoring a condemned one. Annual servicing for a flueless fire simply consists of cleaning the fire, checking the combustion, and checking for damaged components. No problems with chimneys Chimneys and flues are fraught with potential problems, all of which will stop a flued fire from operating safely. 1. The fabric of the chimney could collapse. 2. A nest or debris could block the flue. 3. Atmospheric conditions or open doors can create a down draught. 4. Extractor fans can create a draught to reverse the pull of a chimney, causing it to spill the products of combustion into the room (this makes flueless gas fires particularly popular and safe for use in pubs and restaurants). Burley's flueless gas fires suffer from none of these problems. 9

4111-R chrome Acumen The impressive Acumen hole in the wall fire with ceramic log fuel bed makes a bold and striking statement and boasts a very high maximum heat output. 100% EFFICIENT Minimum room size 50m 3 4111-R two tone chrome 4111-R black 10

4238 / 4238 R chrome Image The Image is a contemporary and versatile fire which can be wall mounted or semi-inset. Minimum room size 30m 3 4237 / 4237 R brushed steel 11

Fire dimensions Height Width Depth Height Width Depth Acumen 4111-R 10 Bl / Ch 4.5kW I 50m 3 L 810 950 582 663 240 Acumen 4111-R 10 Tc 4.5kW I 50m 3 L 670 790 582 663 240 Ambience 4121 3 Bl 3.5kW F 40m 3 L 620 540 335 Esteem 4221 3 Bl 2.5kW F 30m 3 C 620 540 275 Esteem 4231 3 Bl 2.5kW F 30m 3 L 620 540 275 Image 4237 / 4237-R 11 Ss 2.5kW JW 30m 3 P 590 632 198 486 338 91 Image 4238 / 4238-R 11 Ch 2.5kW JW 30m 3 P 590 632 198 486 338 91 Environ 4240 / 4240-R 6 / 7 Br 2.5kW JF 30m 3 C 612 518 240 551 387 95 Environ 4242 / 4242-R 6 / 7 Ch 2.5kW JF 30m 3 C 612 518 240 551 387 95 Environ 4244 / 4244-R 6 / 7 Bl 2.5kW JF 30m 3 C 612 518 240 551 387 95 Environ 4247 / 4247-R 6 / 7 Ss 2.5kW JF 30m 3 P 612 518 240 551 387 95 Name Model Page Finishes Input / Output Positioning Minimum roomsize Thermostat Catalytic converter Fuel effect Overall Inset Key C F I J L P R W Bl Br Ch Co Or Sa Ss Tc Wc Pl Coal effect Freestanding Inset Semi inset Log effect Pebble effect Remote control Wall mounted Black Brass Chrome Contrast Bl + Ss Orbital Satin Brushed stainless steel Two tone chrome With white chips Without white chips Environ 4248 / 4248-R 6 / 7 Br 2.5kW JF 30m 3 C Perception 4260 / 4260-R 4 / 5 Br 2.5kW JF 30m 3 P Perception 4264 / 4264-R 4 / 5 Bl 2.5kW JF 30m 3 P Perception 4267 / 4267-R 4 / 5 Ss 2.5kW JF 30m 3 P Latitude 4500 1 / 2 Or / Sa 2.5kW W 30m 3 Wc / Pl 612 518 240 551 387 95 612 518 240 551 387 95 612 518 240 551 387 95 612 518 240 551 387 95 494 858 160 Inset dimensions Width Latitude 4500 2 Co 2.5kW W 30m 3 Wc / Pl Model numbers ending -R include remote control 486 822 145 Because our policy is one of constant development, details may vary slightly from those given in this publication. Images remain copyright of Burley and may not be reproduced without the permission of Burley Marketing Department. Height installation guide Depth Gas Safe Registered Fitter The fire must be installed and serviced annually by a Gas Safe Register (formerly Corgi) fitter in accordance with the installation instructions. Full instructions are supplied with the fire and on our website. Please read installation instructions before undertaking any structural preparation work. For more information and installation guide, visit www.burley.co.uk/technical_information.php Ventilation As per Building Regulations Part J, an air vent which provides not less than 100cm 2 free air must be installed in the room, at least 1 metre away from the fire. A chimney, ceiling or floor vent is not suitable. Central heating Flueless fires are not designed to be the sole source of heat in a room. They are supplementary to central heating. Existing chimney or flue Existing chimneys and flues must be blocked off completely. A cavity wall box is supplied with the Perception, Environ and Image. We recommend that this is used in all cases. Burley Appliances Limited Lands End Way, Oakham, Rutland LE15 6RB Fireplace requirements The fireplace and all materials within 200mm of the appliance must be non-combustible. All materials, including the fireplace and wall above (including any varnishes, paints etc) must be rated to withstand a constant working temperature of 150ºC. You cannot put televisions etc on the wall above the fire. Gas fires may not be fitted in basements which do not have at least one side open to the outdoors, or in bathrooms. Burley does not recommend flued or flueless gas fires in bedrooms. If in doubt, please call Burley service department for more advice. Natural gas or Propane Please specify natural gas or propane when placing your order as the fires are single category appliances. Due to the properties of propane the flame picture may differ slightly. (Note: Propane option is not available for the Latitude.) Guarantee All products come with a one-year guarantee. Return of the guarantee card and service during the first year of ownership will provide you with a free second-year guarantee (conditions apply). For more information or details of your nearest stockist: Telephone +44 (0)1572 756956 Fax +44 (0)1572 724390 United Kingdom email: sales@burley.co.uk www.burley.co.uk