LM1851 LM1851 Ground Fault Interrupter



Similar documents
LM709 LM709 Operational Amplifier

LM556 LM556 Dual Timer

LM388 LM W Audio Power Amplifier

54LS174,54LS175,DM54LS174,DM54LS175, DM74LS174,DM74LS175

LM5030 LM5030 Application: DC - DC Converter Utilizing the Push-Pull Topology

Application Note AN107

DS8907 DS8907 AM/FM Digital Phase-Locked Loop Frequency Synthesizer

TL081 TL081 Wide Bandwidth JFET Input Operational Amplifier

AMC1100: Replacement of Input Main Sensing Transformer in Inverters with Isolated Amplifier

LM108 LM208 LM308 Operational Amplifiers

LM566C Voltage Controlled Oscillator

Design Note DN304. Cebal CCxxxx Development Tools USB Driver Installation Guide By Åsmund B. Bø. Keywords. 1 Introduction

LM138,LM338. LM138/LM338 5-Amp Adjustable Regulators. Literature Number: SNVS771A

LM381 LM381A Low Noise Dual Preamplifier

LM138 LM338 5-Amp Adjustable Regulators

LM380 Audio Power Amplifier

Providing Continuous Gate Drive Using a Charge Pump

LM1596 LM1496 Balanced Modulator-Demodulator

Data sheet acquired from Harris Semiconductor SCHS078C -- Revised October 2003

LM79XX Series 3-Terminal Negative Regulators

LMS8117A LMS8117A 1A Low-Dropout Linear Regulator

CD4093BM CD4093BC Quad 2-Input NAND Schmitt Trigger

LH0091 True RMS to DC Converter

CD4027BM CD4027BC Dual J-K Master Slave Flip-Flop with Set and Reset

LM117 LM317A LM317 3-Terminal Adjustable Regulator

MM54C150 MM74C Line to 1-Line Multiplexer

APPLICATION NOTE BUILDING A QAM MODULATOR USING A GC2011 DIGITAL FILTER CHIP

CD4008BM CD4008BC 4-Bit Full Adder

54157 DM54157 DM74157 Quad 2-Line to 1-Line Data Selectors Multiplexers

CD4511BM CD4511BC BCD-to-7 Segment Latch Decoder Driver

Analysis of Power Supply Topologies for IGBT Gate Drivers in Industrial

DM54161 DM74161 DM74163 Synchronous 4-Bit Counters

54191 DM54191 DM74191 Synchronous Up Down 4-Bit Binary Counter with Mode Control

5495A DM Bit Parallel Access Shift Registers

5485 DM5485 DM Bit Magnitude Comparators

Importing a SPICE NetList Into TINA9-TI

MM58274C MM58274C Microprocessor Compatible Real Time Clock

LM2900,LM3301,LM3900. LM2900/LM3900/LM3301 Quad Amplifiers. Literature Number: SNOSBV6

LF412 Low Offset Low Drift Dual JFET Input Operational Amplifier

LM101A LM201A LM301A Operational Amplifiers

Ultrasonic Sensing Basics for Liquid Level Sensing, Flow Sensing, and Fluid

DM54LS260 DM74LS260 Dual 5-Input NOR Gate

AN-1733 Load Transient Testing Simplified

LM386 Low Voltage Audio Power Amplifier

Application Report. 1 Description of the Problem. Jeff Falin... PMP Portable Power Applications ABSTRACT

Quad 2-Line to 1-Line Data Selectors Multiplexers

54LS169 DM54LS169A DM74LS169A Synchronous 4-Bit Up Down Binary Counter

54LS193 DM54LS193 DM74LS193 Synchronous 4-Bit Up Down Binary Counters with Dual Clock

TL082 Wide Bandwidth Dual JFET Input Operational Amplifier

AN-225 IC Temperature Sensor Provides Thermocouple Cold-Junction

DM74184 DM74185A BCD-to-Binary and Binary-to-BCD Converters

Design Note DN041. Using CC253X or CC254X with Dipole PCB Antennas. Keywords. 1 Introduction. By Espen Wium CC2530 CC2531 CC2533 CC2540 CC2541

Design Note DN004. Folded Dipole Antenna for CC25xx By Audun Andersen. Keywords. 1 Introduction CC2500 CC2550 CC2510 CC2511

µa7800 SERIES POSITIVE-VOLTAGE REGULATORS

Calculating Gain for Audio Amplifiers

AN-311 Theory and Applications of Logarithmic Amplifiers

DC/DC LED Lighting Developer s Kit Hardware

SDLS068A DECEMBER 1972 REVISED OCTOBER Copyright 2001, Texas Instruments Incorporated

Data sheet acquired from Harris Semiconductor SCHS067B Revised July 2003

LM118/LM218/LM318 Operational Amplifiers

V OUT. I o+ & I o- (typical) 2.3A & 3.3A. Package Type

SDLS940A MARCH 1974 REVISED MARCH Copyright 1988, Texas Instruments Incorporated

ZigBee Sensor Monitor SWRU157D 2008 Low-Power RF

White Paper on Decision of Make vs. Buy of ISM RF Module Written by Bruce Ulrich October 2006

LM78XX Series Voltage Regulators

LMC835 LMC835 Digital Controlled Graphic Equalizer

Data sheet acquired from Harris Semiconductor SCHS087D Revised October 2003

Evaluating the complex configuration options of the Texas Instruments advanced fuel gauges can be

Features. Applications

AN-1963 IEEE 1588 Synchronization Over Standard Networks Using the

AN-1900 LM3150 Evaluation Boards

How to Read a Datasheet

Data sheet acquired from Harris Semiconductor SCHS020C Revised October 2003

LM380 Audio Power Amplifier

TI and ibiquity Introduce Industry s Lowest Cost Single-Chip AM/FM and HD Radio Baseband John Gardner Digital Radio Marketing Manager

LM2941 LM2941C 1A Low Dropout Adjustable Regulator

with Ultra-Fast Transient Response and High Light-Load Efficiency

LM5025,LM5026,LM5034 Operation and Benefits of Active-Clamp Forward Power Converters

Thumbus2300. User's Guide. 1 Introduction. 1.1 Features. 1.2 Kit Contents


Multi-Transformer LED TV Power User Guide. Anderson Hsiao

Application Report. 1 Introduction. 2 Resolution of an A-D Converter. 2.1 Signal-to-Noise Ratio (SNR) Harman Grewal... ABSTRACT

Wireless Subwoofer TI Design Tests

ORDERING INFORMATION. TOP-SIDE MARKING PDIP N Tube SN74LS07N SN74LS07N PACKAGE. SOIC D Tape and reel SN74LS07DR


AN-1405 DP83848 Single 10/100 Mb/s Ethernet Transceiver Reduced Media Independent Interface (RMII ) Mode

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

Introduction to Power Supplies

DM74157 Quad 2-Line to 1-Line Data Selectors/Multiplexers

Using C to Access Data Stored in Program Memory on the TMS320C54x DSP

Texas Instruments. FB PS LLC Test Report HVPS SYSTEM AND APPLICATION TEAM REVA

Features. Note Switches shown in digital high state

LM3444 MR16 Boost Reference Design for Non-Dimming & Dimming LED Applications

LM2907,LM2917. AN-162 LM2907 Tachometer/Speed Switch Building Block Applications. Literature Number: SNAA088

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

CD4071B Quad 2-Input OR Gate CD4072B Dual 4-Input OR Gate CD4075B Triple 3-Input OR Gate

Data sheet acquired from Harris Semiconductor SCHS049C Revised October 2003

LM3940 1A Low Dropout Regulator for 5V to 3.3V Conversion

LM1084 5A Low Dropout Positive Regulators

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

Transcription:

LM1851 LM1851 Ground Fault Interrupter Literature Number: SNIS158

LM1851 Ground Fault Interrupter General Description The LM1851 is designed to provide ground fault protection for AC power outlets in consumer and industrial environments Ground fault currents greater than a presettable threshold value will trigger an external SCR-driven circuit breaker to interrupt the AC line and remove the fault condition In addition to detection of conventional hot wire to ground faults the neutral fault condition is also detected Full advantage of the U S UL943 timing specification is taken to insure maximum immunity to false triggering due to line noise Special features include circuitry that rapidly resets the timing capacitor in the event that noise pulses introduce unwanted charging currents and a memory circuit that allows firing of even a sluggish breaker on either half-cycle of the line voltage when external full-wave rectification is used Features June 1992 Internal power supply shunt regulator Externally programmable fault current threshold Externally programmable fault current integration time Direct interface to SCR Operates under line reversal both load vs line and hot vs neutral Detects neutral line faults LM1851 Ground Fault Interrupter Block and Connection Diagram TL H 5177 1 Order Number LM1851M or LM1851N See NS Package Number M08A or N08E C1995 National Semiconductor Corporation TL H 5177 RRD-B30M115 Printed in U S A

Absolute Maximum Ratings If Military Aerospace specified devices are required please contact the National Semiconductor Sales Office Distributors for availability and specifications Supply Current Power Dissipation (Note 1) Operating Temperature Range Storage Temperature Range 19 ma 1250 mw b40 Ctoa70 C b55 Ctoa150 C Soldering Information Dual-In-Line Package (10 sec ) 260 C Small Outline Package Vapor Phase (60 sec ) 215 C Infrared (15 sec ) 220 C See AN-450 Surface Mounting and Their Effects on Product Reliability for other methods of soldering surface mount devices DC Electrical Characteristics T A e25 C I SS e5ma Parameter Conditions Min Typ Max Units Power Supply Shunt Regulator Voltage Pin 8 Average Value 22 26 30 V Latch Trigger Voltage Pin 7 15 17 5 20 V Sensitivity Set Voltage Pin 8 to Pin 6 6 7 8 2 V Output Drive Current Pin 1 With Fault 0 5 1 2 4 ma Output Saturation Voltage Pin 1 Without Fault 100 240 mv Output Saturation Resistance Pin 1 Without Fault 100 X Output External Current Pin 1 Without Fault Sinking Capability V pin 1 Held to 0 3V (Note 4) 2 0 5 ma Noise Integration Pin 7 Ratio of Discharge Sink Current Ratio Currents Between No Fault 2 0 2 8 3 6 ma ma and Fault Conditions AC Electrical Characteristics T A e25 C I SS e5ma Parameter Conditions Min Typ Max Units Normal Fault Current Figure 1 (Note 3) 3 5 7 ma Sensitivity Normal Fault Trip Time 500X Fault Figure 2 (Note 2) 18 ms Normal Fault with 500X Normal Fault 18 ms Grounded Neutral Fault 2X Neutral Figure 2 (Note 2) Trip Time Note 1 For operation in ambient temperatures above 25 C the device must be derated based on a 125 C maximum junction temperature and a thermal resistance of 80 C W junction to ambient for the DIP and 162 C W for the SO Package Note 2 Average of 10 trials Note 3 Required UL sensitivity tolerance is such that external trimming of LM1851 sensitivity will be necessary Note 4 This externally applied current is in addition to the internal output drive current source FIGURE 1 Normal Fault Sensitivity Test Circuit TL H 5177 2 2

Internal Schematic Diagram TL H 5177 3 3

Typical Performance Characteristics Average Trip Time vs Fault Current Normal Fault Current Threshold vs R SET Output Drive Current vs Output Voltage Pin 1 Saturation Voltage vs External Load Current I L TL H 5177 4 Circuit Description (Refer to Block and Connection Diagram) The LM1851 operates from 26V as set by an internal shunt regulator D3 In the absence of a fault (I f e0) the feedback path status signal (V S ) is correspondingly zero Under these conditions the capacitor discharge current I 1 sits quiescently at three times its threshold value I TH so that noise induced charge on the timing capacitor will be rapidly removed When a fault current I f is induced in the secondary of the external sense transformer the operational amplifier A1 uses feedback to force a virtual ground at the input as it extracts I f The presence of I f during either half-cycle will cause V S to go high which in turn changes I 1 from 3I TH to I TH Although I TH discharges the timing capacitor during both half-cycles of the line I f only charges the capacitor during the half-cycle in which I f exits pin 2 Thus during one half-cycle I f I TH charges the timing capacitor while during the other half-cycle I TH discharges it When the capacitor voltage reaches 17 5V the latch engages and turns off Q3 permitting I 2 to drive the gate of an SCR 4

Application Circuits A typical ground fault interrupter circuit is shown in Figure 2 It is designed to operate on 120 V AC line voltage with 5 ma normal fault sensitivity A full-wave rectifier bridge and a 15k 2W resistor are used to supply the DC power required by the IC A 1 mf capacitor at pin 8 used to filter the ripple of the supply voltage and is also connected across the SCR to allow firing of the SCR on either half-cycle When a fault causes the SCR to trigger the circuit breaker is energized and line voltage is removed from the load At this time no fault current flows and the IC discharge current increases from I TH to 3I TH (see Circuit Description and Block Diagram) This quickly resets both the timing capacitor and the output latch At this time the circuit breaker can be reset and the line voltage again supplied to the load assuming the fault has been removed A 1000 1 sense transformer is used to detect the normal fault The fault current which is basically the difference current between the hot and neutral lines is stepped down by 1000 and fed into the input pins of the operational amplifier through a 10 mf capacitor The 0 0033 mf capacitor between pin 2 and pin 3 and the 200 pf between pins 3 and 4 are added to obtain better noise immunity The normal fault sensitivity is determined by the timing capacitor discharging current I TH I TH can be calculated by I TH e 7V d2 (1) R SET At the decision point the average fault current just equals the threshold current I TH I TH e I f(rms) c0 91 (2) 2 where I f(rms) is the rms input fault current to the operational amp and the factor of 2 is due to the fact that I f charges the timing capacitor only during one half-cycle while I TH discharges the capacitor continuously The factor 0 91 converts the rms value to an average value Combining equations (1) and (2) we have 7V R SET e (3) I f(rms) c0 91 For example to obtain 5 ma(rms) sensitivity for the circuit in Figure 2 we have 7V R SET e e1 5M X (4) 5mAc0 91 1000 The correct value for R SET can also be determined from the characteristic curve that plots equation (3) Note that this is an approximate calculation the exact value of R SET depends on the specific sense transformer used and LM1851 tolerances Inasmuch as UL943 specifies a sensitivity window of 4 ma 6 ma provision should be made to adjust R SET on a per-product basis Independent of setting sensitivity the desired integration time can be obtained through proper selection of the timing capacitor C t Due to the large number of variables involved proper selection of C t is best done empirically The following design example then should only be used as a guideline Assume the goal is to meet UL943 timing requirements Also assume that worst case timing occurs during GF1 start-up (S1 closure) with both a heavy normal fault and a 2X grounded neutral fault present This situation is shown diagramatically below TL H 5177 5 UL943 specifies s25 ms average trip time under these conditions Calculation of C t based upon charging currents due to normal fault only is as follows s25 ms Specification b3 ms GFI turn-on time (15k and 1 mf) b8 ms Potential loss of one half-cycle due to fault current sense of half-cycles only b4 ms Time required to open a sluggish circuit breaker s10 ms Maximum integration time that could be allowed 8 ms Value of integration time that accommodates component tolerances and other variables C t e I c T (5) V where T e integration time V e threshold voltage c I e average fault current into C t I e 120 V AC(rms) R B J c R N R G a R NJ X X heavy fault current generated (swamps I TH ) 1 1000 turnsj c 1 2J portion of fault current shunted around GFI c (0 91) (6) X X X current C t charging rms to division of on half- average input sense cycles only conversion transformer therefore C t e 120 500J c 1 6a0 4J c 1 C t e 0 01 mf 1000J c 1 2J c(0 91) c0 0008 ( (7) 17 5 5

Application Circuits (Continued) in practice the actual value of C1 will have to be modified to include the effects of the neutral loop upon the net charging current The effect of neutral loop induced currents is difficult to quantize but typically they sum with normal fault currents thus allowing a larger value of C1 For UL943 requirements 0 015 mf has been found to be the best compromise between timing and noise For those GFI standards not requiring grounded neutral detection a still larger value capacitor can be used and better noise immunity obtained The larger capacitor can be accommodated because R N and R G are not present allowing the full fault current I to enter the GFI In Figure 2 grounded neutral detection is accomplished by feeding the neutral coil with 120 Hz energy continuously and allowing some of the energy to couple into the sense transformer during conditions of neutral fault Typical Application Adjust R SET for desired sensitivity FIGURE 2 120 Hz Neutral Transformer Approach TL H 5177 6 6

Definition of Terms Normal Fault An unintentional electrical path R B between the load terminal of the hot line and the ground as shown by the dashed lines Normal Fault plus Grounded Neutral Fault The combination of the normal fault and the grounded neutral fault as shown by the dashed lines TL H 5177 7 Grounded Neutral Fault An unintentional electrical path between the load terminal of the neutral line and the ground as shown by the dashed lines TL H 5177 9 TL H 5177 8 7

LM1851 Ground Fault Interrupter Physical Dimensions inches (millimeters) Molded Dual-In-Line Package (N) Order Number LM1851N NS Package Number N08E LIFE SUPPORT POLIC NATIONAL S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMICONDUCTOR CORPORATION As used herein 1 Life support devices or systems are devices or 2 A critical component is any component of a life systems which (a) are intended for surgical implant support device or system whose failure to perform can into the body or (b) support or sustain life and whose be reasonably expected to cause the failure of the life failure to perform when properly used in accordance support device or system or to affect its safety or with instructions for use provided in the labeling can effectiveness be reasonably expected to result in a significant injury to the user National Semiconductor National Semiconductor National Semiconductor National Semiconductor Corporation Europe Hong Kong Ltd Japan Ltd 1111 West Bardin Road Fax (a49) 0-180-530 85 86 13th Floor Straight Block Tel 81-043-299-2309 Arlington TX 76017 Email cnjwge tevm2 nsc com Ocean Centre 5 Canton Rd Fax 81-043-299-2408 Tel 1(800) 272-9959 Deutsch Tel (a49) 0-180-530 85 85 Tsimshatsui Kowloon Fax 1(800) 737-7018 English Tel (a49) 0-180-532 78 32 Hong Kong Fran ais Tel (a49) 0-180-532 93 58 Tel (852) 2737-1600 Italiano Tel (a49) 0-180-534 16 80 Fax (852) 2736-9960 National does not assume any responsibility for use of any circuitry described no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications

IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video RFID OMAP Mobile Processors Wireless Connectivity www.ti-rfid.com www.ti.com/omap www.ti.com/wirelessconnectivity TI E2E Community Home Page e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright 2011, Texas Instruments Incorporated