High Performance Vacuum Pump Model 15401/15601/15603/15605 Operating Manual... 2



Similar documents
US VACUUM CP SERIES MANUAL. Oil Lubricated, Rotary Vane Vacuum Pumps INSTALLATION OPERATION. Models CPS-5B & CPS-8B WARNING

DiscovR R134a Refrigerant Identifier

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

CARING FOR YOUR WATER HEATER

Rexroth Hydraulic Pump A10VO Series User Manual

PC1131 Electric Air Compressor

Operations and Maintenance Manual

PC1130 Electric Air Compressor

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Visit our website at: our technical support at:

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Air vacuum pump with r134a & r12/22

Subject: 2005 Air Conditioning Service Guidelines

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

COMPRESSED AIR DRYER

Oil and Coolant Circulating Heating System. Model - OCSM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for AR512 series and SAE J2099 and J2210 for AR500 series

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Trouble Shooting. Pump

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Line to Refrigerator Ice/Water Dispenser

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Compressor Service & Maintenance Manual

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Recovery/ Recycling/ Recharging Unit

Flushing and Cleaning the A/C System

1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves

SunMaxx Solar Filling Station Operating Instructions

Dehumidifier Users manual. For Models: DH45S DH65S

2 HP / 4 GALLON AIR COMPRESSOR OWNER'S MANUAL

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

LOBOY 16 AIR CONDITIONERS

15GAL STEEL OIL DRAIN WITH 110V PUMP

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Cooling system components, removing and installing

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

HPU14M-DS 2013 Daniels Manufacturing Corp., All Rights Reserved Page 1 of 17 REV. C 7/2013

01 12 COOLING SYSTEM COOLING SYSTEM. End of Toc. End Of Sie

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

Multi-Pitch Pitching Machine USER MANUAL

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Instruction Manual. Please read the manual carefully before installing and using this product. This product is for off road use only.

Volkswagen Golf > VW Rabbit GTI 2006->

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Cooling system components, removing and installing

Fuel Injection Pump, Rotary ( )

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Draining and filling cooling system

ClearView 100. Instruction Manual

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

accidents which arise due to nonobservance and the safety information herein.

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

4 Gallon Air Compressor Assembly & Operating Instructions

SILENT AIR COMPRESSOR

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Rules for Safe Operation

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

ENGINE COOLING SYSTEM

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Your safety and the safety of others are very important.

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Cooling Systems. Table of Contents

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

10ACC WARNING WARNING. Service Literature 10ACC SERIES UNITS

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Operating Manual for Model Recovery, Recycling, Recharging Unit

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

MODEL G300 BRAKE BLEEDER

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Cryogenic Vacuum Pumps

The Storm 20-Gallon Wet/Dry Vac

Portable Air Conditioner

Ceiling Mount Air Handler Manual

Safety, Operation and Maintenance Manual with Parts List

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Transcription:

High Performance Vacuum Pump Model 15401/15601/15603/15605 Operating Manual... 2 Bombas de Vacío de Alto Rendimiento Modelo 15401/15601/15603 Manuel del Operador... 8 Pompe à Vide à Haut Rendement Modèle 15401/15601/15603 Manuel d utilisation... 16 Hochleistungs-Vakuumpumpe Modelle 15401/15601/15603 Bedienungsanleitung... 24

Operating Manual Table of contents Robinair high performance vacuum pumps...2 Pump components...3 Warnings...3 Before using your vacuum pump...4 To use the gas ballast feature...5 To shut down your pump after use...5 To maintain your high vacuum pump...5 Vacuum pump oil...5 Oil change procedure...5 Cleaning your pump...5 Motor lubrication...5 Troubleshooting guide...6 Failure to start...6 Oil leakage...6 Failure to pull a good vacuum...6 Pump specifications...6 Replacement parts...7 Warranty coverage...7 Out of warranty...7 For use on A/C-R systems using CFCs, HCFCs and HFCs in conjunction with mineral oil, ester oil, alkylbenzene oil and PAG oil as lubricants. Not for use with ammonia or lithium bromide systems. Not for use with flammable refrigerants. Robinair high performance vacuum pumps Congratulations on purchasing one of Robinair s top quality vacuum pumps. Your pump has been engineered specifically for air conditioning and refrigeration service, and is built with Robinair s proven offset rotary vane for fast, thorough evacuation. You ll appreciate these key features... Iso-Valve TM Allows the pump to be shut off while still connected to the A/C-R system, which is handy for checking rate of rise. With the valve handle in the OPEN position, the pump is open to the system being evacuated. In the CLOSE position, the pump is isolated from the system. This minimizes pump oil pulled into the pumping module, making start-up easier and reducing wear and tear on the pump components. High vacuum rating The two-stage, offset rotary vane design provides powerful, quiet, high vacuum capability and ensures moisture removal, while the high pumping capacity reduces evacuation time. Lifetime filtration The intake filter prevents foreign matter from entering the pumping chamber, and an internal exhaust filter separates oil vapor from the exhaust flow. Directed exhaust The exhaust is expelled through the handle to direct it away from the service technician. Gas ballast A precise amount of atmospheric air is introduced into the pump, preventing condensation of moisture vapor and helping maintain the purity of the pump oil. By using the gas ballast, the pump operates more efficiently and pump life is extended. Sure-grip handle The one-piece, molded handle makes it easy to carry the pump to and from job sites, and the handle stays cool to the touch during operation. Compact design The pump measures approximately 40 cm long, while aluminum housing and offset rotary vanes keep the pump weight low, making it easy to carry. 2

11 12 1 2 3 10 4 9 Pump Components 1. Intake Fitting 2. Gas Ballast Valve (located beside handle base) 3. Oil Fill Port 4. Sight Glass 5. Die-Cast Aluminum Housing 6. Oil Drain 7. Molded Polycarbonate Base 8. Iso-Valve TM (isolates the pump from the system) 9. High Torque Motor 10. Power Switch 11. Through-the-Handle Exhaust 12. Sure-Grip Handle 8 7 Warnings Wear goggles when working with refrigerants. Contact with refrigerants may cause injury. Incorrect use or connections may cause electrical shock. Study and follow the instructions carefully. and take precautions to avoid electrical shock hazards. All associated devices must be grounded before energizing circuits. The normal operating temperature will cause certain external portions of the pump to be hot to the touch. Do not touch the pump housing or motor during operation. 6 5 Operating Manual NOTICE: Airborne Noise Emissions This equipment has been tested for airborne noise emission per the Council Directive for Machinery (89/392/EEC) Section 1.7.4 Instructions Essential Health and Safety Requirements. Sound levels do not exceed 80dB(A) actual value. 116292 Rev. F June 18, 2013 3

Before using your vacuum pump Operating Manual In all cases, motors are designed for operating voltages plus or minus 10% of the normal rating (see SPECIFICATIONS). 1. Verify the voltage and frequency at the outlet match the specifications on the pump motor decal. Verify the ON / OFF switch is in the OFF position before you plug the pump into an outlet. Verify the gas ballast valve is closed. Remove and discard the exhaust plug from the end of the pump s handle. 2. The pump is shipped without oil in the reservoir. Before starting the pump, fill with oil. Remove the OIL FILL cap (black plastic plug directly in front of the handle), and add oil until the oil just shows in the bottom of the sight glass. The approximate oil capacity of the pump is 375 milliliters. 3. Replace the OIL FILL cap and remove the cap from one of the inlet ports. Turn the Iso-Valve to OPEN. Turn the motor switch ON. When the pump runs smoothly, turn the Iso-Valve to CLOSED and replace the cap on the inlet port. This may take from two to 30 seconds, depending on the ambient temperature. After the pump runs for approximately one minute, check the sight glass for correct oil level oil should be even with the sight glass OIL LEVEL line. Add more oil if necessary. When the pump is running, the oil level should be even with the line on the sight glass. Underfilling will result in poor vacuum performance. Overfilling can result in oil blowing from the exhaust. Your pump is now ready to evacuate air conditioning and refrigeration systems. Follow normal service procedures and the A/C-R manufacturer s instructions for connections to the system. CAUTION! Before connecting the vacuum pump to an A/C-R system, remove refrigerant from the system in an accepted manner. Damage to the pump may occur if evacuation is started while the system is under high pressure. Robinair recommends use of our Refrigerant Recovery and Recycling equipment. Wiring Instructions: This vacuum pump features dual voltage ranges. Before operating the pump, read and follow these rewiring instructions (if necessary) to be sure your pump is wired for the appropriate voltage. CAUTION! Unplug the unit before beginning any service work. Incorrect use or connections can cause electrical shock. Only qualified personnel should perform service work. This vacuum pump is factory wired for a high voltage range of 220 to 250 volts. To wire the switch for a low voltage range of 110 volts to 115 volts, follow these steps: 1. Disconnect the unit from the AC power source. 2. Loosen the screws on the plate at the rear of the motor, and carefully move the plate aside to clear the opening. 3. Disconnect the leads and reconnect for low voltage, following the diagram and chart. (High voltage connections are also shown if you want to rewire in the future.) 4. Verify connections are secure and there are no short circuits. Verify the grounding connector is correctly connected. 5. Re-install the plate on the rear of motor with the screws which were loosened in Step 2. IMPORTANT: Check for short circuits using a continuity tester before reconnecting to the AC power source. NOTE: EXTERNAL POWER LEADS ARE ALWAYS CONNECTED TO TERMINALS 1 AND 4. EMERSON INTERNAL VOLTAGE CONNECTION MOTOR LOW HIGH LEAD VOLTAGE VOLTAGE BROWN 3 6 WHITE 4 3 BLACK 2 3 INST0350 4 General Electric Motors Emerson Motors

To use the gas ballast feature To maintain the high vacuum pump Moisture from the A/C-R system that is carried into the pump as a vapor tends to condense into a liquid and combine with the vacuum pump oil. When moisture contaminates the pump oil, it reduces the pump s ability to reach its ultimate deep vacuum level. The gas ballast valve purges a small amount of atmospheric air through the exhaust chamber. This extra volume of air mixes with the vapor from the refrigerant system to prevent condensation and to help exhaust moisture in the form of vapor from the pump. To use the gas ballast, start the pump and open the gas ballast valve until the system has reached approximately 1000 3000 microns. Close the valve to allow the pump to pull down to its ultimate vacuum level. (The gas ballast valve is located beside the handle, opposite the inlet fitting.) The gas ballast valve may be opened or closed at any time during pump operation. It is fully open at two turns counterclockwise. NOTE: Robinair recommends the use of a thermistor vacuum gauge to most accurately measure vacuum levels. To shut down the pump after use To help prolong pump life and promote easy starting, follow these procedures for shutdown: 1. Close the manifold valve between the pump and the system. 2. Turn the Iso-Valve to the CLOSED position. 3. Remove the hose from the pump inlet. 4. Turn the pump power switch to OFF, then return the Iso-Valve to the OPEN position for a few seconds to relieve any vacuum inside the pump. 5. Cap the inlet port to prevent any contamination or loose particles from entering the port. For maximum performance, Robinair recommends changing vacuum pump oil after each use. Vacuum pump oil The condition and type of oil used in any high vacuum pump are extremely important in determining the ultimate attainable vacuum. Robinair recommends the use of our Premium High Vacuum Pump Oil. This oil has been specifically blended to maintain maximum viscosity at normal running temperatures and to improve cold weather starts. Our Premium High Vacuum Pump Oil is available in quart or gallon containers. Order by part number: 13203 Quart (shipped 12 quarts per case) 13204 Gallon (shipped 4 gallons per case) Oil change procedure 1. Be sure the pump is warmed up. 2. Remove the OIL DRAIN cap. Drain contaminated oil into a suitable container and dispose of correctly. Oil can be forced from the pump by opening the inlet and partially blocking the exhaust with a cloth while the pump is running. Do not operate the pump for more than 20 seconds using this method. 3. When the flow of oil has stopped, tilt the pump forward to drain residual oil. 4. Replace the OIL DRAIN cap. Remove the OIL FILL cap, and fill the reservoir with new vacuum pump oil until the oil just shows at the bottom of the sight glass. The approximate oil capacity of the pump is 375 milliliters. 5. Verify the inlet ports are capped. Turn ON the pump, and allow it to run for one minute. Check the oil level. If the oil is below the sight glass OIL LEVEL line, add oil slowly (with the pump running) until the oil reaches the OIL LEVEL line. Replace the OIL FILL cap, cap the inlet, and tighten the drain cap. 6. If the oil is badly contaminated, you may need to flush the pump. To flush, remove the pump drain cap and start the pump. Slowly pour a small quantity of new pump oil through the oil fill inlet. Repeat this procedure as required until the contamination is removed. Replace the OIL DRAIN cap and refill the reservoir to the correct level using fresh pump oil (Step 4). Cleaning the pump Use only soap and water to clean the pump. Do not use commercial cleaners that contain degreasing agents that can damage polycarbonates. The pump handle and base are made of Lexan, one of the toughest polycarbonate plastics available. However, it is sensitive to degreasing agents. *Lexan is a registered trademark of General Electric Motor lubrication After three years of normal service or one year of heavy-duty service, add motor oil. Use electric motor oil or SAE 10 oil. Operating Manual 5

Operating Manual Troubleshooting guide This pump has been designed for dependable use and long life. If something should go wrong, however, the following guide will help you get the pump back into service as quickly as possible. If disassembly of the pump is required, please check your warranty. The warranty may be voided by misuse or customer tampering that results in the pump being inoperable. Failure to start Check line voltage. Robinair pumps are designed to start at +10% line voltage (loaded) at 0 o C. At extremes, however, switching between the start and run windings may occur. When starting the pump in cold temperatures, verify the Iso-Valve and inlet port are open to free air. Oil leakage 1. Verify the oil is not a residual accumulation from spillage, etc. 2. If leakage exists, the module cover gasket or the shaft seal may need replacing. Follow the instructions supplied with the seal replacement kit, part number 15367. If leakage exists in the area of the drain plug, reseal the plug using a commercial pipe thread sealer. Failure to pull a good vacuum 1. Verify the Iso-Valve on the pump is in the OPEN position, and the gas ballast knob is tightly sealed. 2. Verify the vacuum gauge and all connections are in good conditon and leak-free. Confirm leakage by monitoring the vacuum with a thermistor gauge while applying vacuum pump oil at connections or suspected leak points. Vacuum will improve briefly while the oil is sealing the leak. 3. Be sure the pump oil is clean. A badly contaminated pump may require several oil flushes. See OIL CHANGE PROCEDURE. 4. Verify the oil is at the correct level. For maximum pump operation, the oil must be even with the OIL LEVEL line on the sight glass when the pump is running. See OIL CHANGE PROCEDURE. Do not overfill. Operating temperatures cause the oil to expand, so it will appear at a higher level than when the pump is not running. To check the oil level, start the pump with the inlet capped. Check the oil level in the sight glass. Add oil if necessary. Pump Specifications Model 15401 Frequency Range... 50-60 Hz Free Air Displacement...4 cfm/60 Hz... 94 l/m @ 50 Hz... 113 l/m @ 60 Hz Stages...2 Motor Speed...1425 rpm @ 50 Hz...1725 rpm @ 60 Hz Voltage Range...110V 115V... 220V 250V Factory Micron Rating... 15 microns Approximate Oil Capacity... 400 ml Weight... 13 kg Width... 14.29 cm Height... 24.6 cm Length... 40 cm Intake... 1 /4" and 1 /2" SAE MFL Min. Starting Temp. (at 90% voltage)... 0 o C Motor Size...0.25kW ( 1 /3 HP) Capacitor Start Operating Temp... 68 o C Models 15601/15603/15605 Frequency Range... 50-60 Hz Free Air Displacement...6 cfm/60 Hz... 142 l/m @ 50 Hz... 170 l/m @ 60 Hz Stages...2 Motor Speed...1425 rpm @ 50 Hz...1725 rpm @ 60 Hz Voltage Range...110V 115V... 220V 250V Factory Micron Rating... 15 microns Approximate Oil Capacity... 400 ml Weight... 13 kg Width... 14.29 cm Height... 24.6 cm Length... 42 cm Intake... 1 /4", 3 /8", and 1 /2" SAE MFL Min. Starting Temp. (at 90% voltage)... 0 o C Motor Size...0.25 kw ( 1 /3 HP) Capacitor Start Operating Temp... 68 o C Notes: 1. All motors are internally protected (automatic reset). 2. Operating temperatures are typical for normal operating conditions. 3. Model 15603 has a bipolar side grounded plug. 4. Models 15405 & 15605 have Australian plugs. Because of ongoing product improvements, we reserve the right to change design, specifications, or materials without notice. 6

12 11 9 8 9 9 7 13 14 6 5 15 4 3 INST0026 Replacement parts 15605/ 15601/ Part Item 15401 15603 Oil Drain Cap (6) 1 40572 40572 Oil Drain Kit (includes Item No. 1) 2 13193 13193 Module Cover Kit (includes Nos. 2, 4, and 5) 3 15337 15337 Oil Fill Cap (includes No. 7) 4 15371 15371 Intake Fitting (includes No. 9) 8 15364 555124 Intake Cap (1 ea.) 1 /4", 3 /8", 1 /2" SAE MFL 9 555133 555133 Vent Bolt (includes o-rings) 11 15338 15338 Handle, Power Cord and Switch Assembly 12 15466 15466 Motor 13 15465 15465 Coupling 14 13192 13192 Iso-Valve TM Assembly 15 15368 15368 Base and Foot Assembly 16 15369 15369 Pump Assembly, less motor (includes No. 3 and 6) 17 15547 15548 Seal Replacement Kit (not shown) -- 15367 15367 16 17 Warranty coverage Robinair vacuum pumps are warranted against defects in material and workmanship for one year of normal use from the date of purchase. See your distributor for warranty details. Out of warranty A pump which is no longer covered by the oneyear warranty period and which fails to operate properly should be returned to the distributor with a full written explanation of the problem. The distributor may suggest returning the pump to the factory. Before returning an out-of-warranty pump, review all maintenance procedures to avoid an unnecessary return. Replacement parts are available for doing your own service. 2 1 Operating Manual 7

Call our Toll-Free % Technical Support Line at 800-822-5561 in the continental U.S. and Canada or visit our website www.robinair.com In all other locations, contact your local distributor. To help us serve you better, be prepared to provide the model number, serial number, and date of purchase of your unit. To validate your warranty, complete the warranty card attached to your unit and return it within ten days from date of purchase. NATIONWIDE NETWORK OF AUTHORIZED SERVICE CENTERS If your unit needs repairs or replacement parts, contact the service center in your area. For help in locating a service center, call the toll-free technical support line, or visit our website. Due to ongoing product improvements, we reserve the right to change design, specifications, and materials without notice. BOSCH AUTOMOTIVE SERVICE SOLUTIONS 655 EISENHOWER DRIVE OWATONNA, MN 55060 USA TECHNICAL SERVICES: 1-800-822-5561 FAX: 1-866-259-1241 CUSTOMER SERVICE: 1-800-533-6127 FAX: 1-800-283-8665 WEB SITE: WWW.ROBINAIR.COM 116292 Rev. F June 18, 2013 Bosch Automotive Service Solutions