EPIC. Uniclass. L5161+L542:N373 Cl/SfB E122:Y45 (42)+(45) R (P3)



Similar documents
Smartstrand Cleaning Guidelines

YOUR EXPERT CARPET GUIDE BROUGHT TO YOU BY CARPET COUNTRY

tretford Maintenance Instructions

Heavy traffic areas which begin to show soiling can be cleaned without cleaning the entire carpet by using:

PROCHEM EUROPE LTD SPOT & STAIN REMOVAL GUIDE

Sunbrella Care and Cleaning Instructions

INSTALLATION & CLEANING INSTRUCTIONS FOR SOLUTION-DYED NYLON CARPETS

Developing A Plan To develop a proper plan, you should define the type of traffic patterns the carpet will receive.

sound reduction systems for commercial, educational and industrial environments

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

WOVEN CARPET DRY CLEANING KIT INFORMATION & DIRECTIONS FOR USE. Ph:

MIRACLE FIBRE COLOUR FAST BLEACH RESISTANT COLOUR FAST BLEACH RESISTANT. Caring. for your Stainproof carpet FLOORCOVERINGS (PTY)LTD.

CLEANING GUIDE.

Domestic Cleaning and Maintenance Guide

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Carpet Care & Maintenance

Protect your investment

Product Information. Tel: x2426 or x2443 Fax:

Care and Maintenance for Wood Flooring

Table of Contents Markers...1

Carpet Warranty & Maintenance Guide

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

Work from the outside to the center of large stains to prevent spreading.

REDEFINING INNOVATION AND SUSTAINABILITY IN THE DESIGN OF INTERIOR ACOUSTICS

Fiberglas, Exterior Wall Thermal Insulation

Total Floor Care System

ROOM ACOUSTICS DESIGN. Room Acoustics Design Intent: Appropriate Articulation

Acoustic. Publication date June

CARE AND MAINTENANCE: WOOL CARPET

Product Data Sheet ROCKPANEL Rockclad

WARRANTY, PERFORMANCE AND CARE GUIDE

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

CARPET CARE & MAINTENANCE GUIDE

Stone Developments. Caring for Irish Blue Limestone Products. Irish Blue Limestone Maintenance Guide

did you know? ...you can choose from thousands of carpet and flooring options carpets & flooring FURNITURE & INTERIORS

Energy Company Obligation (ECO): Technical Monitoring Questions

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

WELCOME TO ENGINEERED FLOORS

Ecophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x x x x600 M206, M208, M238

Rooflighting and Glazing

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Ecophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x x x600

Columbia flooring will resist fading from exposure to sunlight or artificial light.

Healthcare Environments Cleaning, Care, and Maintenance

Rockwool Flexi Insulation Application Guide

Maintenance Specification Guide

PTFE Slide Bearings 04/10 149

Acoustic design with wall acoustic solutions

Controlling the Transmission of Impact Sound through Floors

Site sampling and testing of concrete

All Purpose Cleaner. Carpet Care. Specialty Cleaner

DIY CABINET REFACING INSTALLATION GUIDE

How does Architecture Affect the Acoustics of a Space

CAREPLUS CARE AND MAINTENANCE GUIDELINE Page 1 of 5

Contents BB93 Acoustic Design for Schools

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

GigaCrete Specification PlasterMax

Important Information

Congratulations! Quality products for quality floors

Wetroom Panel (Concealed Fix)

BedRug Bedliner Installation Instructions. Part Number(s): Multiple. Preparation

carpet care, cleaning and maintenance handbook

Leeds Metropolitan University - Design and Build of new Acoustic Laboratory Suite

Installation Instructions

ACOUSTICS. Axiom Canopy Clouds Absorption Data Sabines (average 500, 1k, 2k, 4k Hz) ACOUSTICS TESTING DATA Sound Absorption in Sabines

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Cleaning of floor coverings. Vacuum Cleaners Brush-Type Vacuum Cleaners Spray Extractors Single Disc Machines Cleaning Machines - Cleanser

CARPET MAINTENANCE & CLEANING MANUAL. A Tarkett Company THE ULTIMATE FLOORING EXPERIENCE

Bafl-Sorb Sound Absorbing Ceiling Baffles

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Affordable Sports Halls

VERTICAL DESIGN OPTImAL ACOUSTICS

If you hire a Professional Wood Fitter. If fitting the Wood Floor yourself (DIY)

Adelman 1001 S. 84th Street West Allis, WI (414)

Vacating Your Northwood III Apartment

Acoustic design according to room type

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Limited Warranties STAINMASTER Carpet. stainmaster.com

Rockwool Cladding Roll

Keeping your Carpet Beautiful

Contents. Introduction... A Note About Heatsinks... Precautions...

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

ProRox Slabs (formerly known as RW slabs)

74 Chapter CO 2 Cleaning

FLOOR MAINTENANCE GUIDE EXPECTATIONS AVOIDING PROBLEMS

General Carpet Care Basics

Shaw Limited Lifetime Stain Warranty

Composite Panel Firewall Systems

FIRE RESTORATION PRODUCTS

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Coastal Comfort PURECOLOR - SOFT YARN CARPET. Lifetime Stain Warranty

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Armstrong Do-It-Yourself Tile Installation System

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

2012 /13 Design Guide

pinta ACOUSTIC PANEL [1/7]

After The Fire The First 24 Hours

QWALL 4 ACRYLIC SHOWER WALL INSTALLATION INSTRUCTIONS

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Transcription:

Uniclass L5161+L542:N373 Cl/SfB EPIC E122:Y45 (42)+(45) R (P3) CMS SuperPhon range Sound absorption for walls and ceilings

Sound absorption Reverberation time is a measure of how long it takes noise to die away after the sound source ceases. Achieving the optimum reverberation times for a room is vital in sound sensitive spaces such as schools and call centres, where echoing sound can be particularly disruptive to the occupants. The most commonly used method of controlling reverberation times is acoustic wall coverings or ceiling panels. Comprising attractive wall mounted and ceiling suspended acoustic systems, the CMS SuperPhon range is designed to absorb high levels of reflected noise within a room to improve the listening environment. Flexible by design Accommodating flexibility of use and design, SuperPhon acoustic wall coverings and ceiling systems offer a cost effective solution to reverberation challenges. As a fully bespoke solution, CMS SuperPhon is tailored to exact project requirements including system size, acoustic performance and final finish. Using dedicated in-house resources, from design through to manufacture and delivery, CMS Acoustics ensures an efficient turnaround of all SuperPhon products in line with specific project timescales. With a lightweight structure and aesthetically pleasing finish, the SuperPhon range is ideal for a wide variety of applications including recording studios, offices, schools, cinemas, theatres and leisure centres.

CMS SuperPhon range Offering complete or partial wall coverage, as well as a suspended sound solution, the SuperPhon range provides an effective means of controlling reverberation times and reflected sound in rooms. Selecting a SuperPhon system The most appropriate acoustic system for an area will depend on the sound absorption performance required and environmental constraints. For example, in noise sensitive spaces such as recording studios, CMS SuperPhon Wall Panels offer a complete floor to ceiling solution for superior sound absorption. Where there is a risk of impact, such as in sports halls or spaces with high levels of public traffic, SuperPhon absorbers are ideal, as the ceiling-suspended installation keeps them out of reach, preventing damage to the acoustic treatment. For all applications, CMS SuperPhon systems can be designed to either complement the existing décor or be used as an attractive feature or focal point, which is particularly useful when the treatment is to be applied retrospectively. Complete wall coverage Manufactured from sound absorbing, non-combustible, mineral board, covered with high quality open weave fabric, the SuperPhon Wall System combines excellent acoustic absorption properties with an aesthetically pleasing finish. Available in standard or bespoke sizes and thicknesses, the CMS SuperPhon Wall System is ideal for use in noise sensitive spaces, such as recording studios, audiology rooms and call centres. The wall panels can be positioned to achieve total wall coverage for superior sound absorption. U channels on the top and bottom of the SuperPhon Wall System are used to fix the panels to the wall, with a variety of trims available to cover vertical joints and internal and external corners. In addition, channels and trims can also be cover matched to the liner panel fabric to achieve a seamless finish from floor to ceiling. Partial wall coverage Where reflected sound needs to be absorbed but complete wall coverage is not practical, CMS SuperPhon Panels have been designed to offer partial wall coverage. Whether blending in with the existing environment, enhancing architectural features or creating a new design feature, the panels offer a cost effective solution for rooms requiring a low reduction in reverberation times. As the panels are retrospectively applied, they are suitable for use in both new build projects and remedial works. Acoustic panels can be fixed directly to the wall using a variety of concealed fixing methods including adhesives and wall fixing plates. Where removable pads are required, Velcro pads can be used in conjunction with the base support angle. For increased performance, the panels can be installed on timber battens to create an air void for additional absorptive properties. Suspended absorbers Providing a high performance sound absorption system, CMS SuperPhon Suspended Absorbers are designed for use in areas where total wall coverage is not practical, whether because of impact challenges or access requirements. The composition of a mineral fibre or open-cell melamine absorbing foam core, covered with an open weave fabric provides a lightweight structure. As such, CMS SuperPhon Suspended Absorbers can be applied to ceilings using a range of bespoke suspension methods. The absorbers can be suspended out of sight or manufactured in a fabric to blend in with the existing environment or, for maximum design impact, there is also the option to use the panels as a striking design feature.

Features and Benefits With a wide selection of colour finishes and installation options, the SuperPhon range provides an aesthetically pleasing reverberation solution for a range of applications. Design flexibility The SuperPhon range is available in standard sizes and thicknesses, and bespoke panels and absorbers of a specific size, thickness, shape or fabric facing can be readily manufactured. As well as the broad offering of standard fabric colours, panels can be colour matched to any chosen fabric. Applications With a flexible design and installation process, the CMS SuperPhon range is suitable for a variety of applications where reverberation times and reflected sound needs to be addressed. The wall covering systems and suspended absorbers are ideal for use in schools to achieve BB93 standards for reverberation times. Bespoke installation options CMS SuperPhon systems can be installed using a range of non-visible fixings systems, such as Velcro strips or fabric covered metal strips fixed between top and bottom U channels, allowing panels to be easily removed for access. Alternatively, the panels and absorbers can be installed permanently using wall fixing plates. CMS Acoustics provides comprehensive installation guidelines with each product. Maintenance and care To maintain their appearance, SuperPhon Wall Panels and Suspended Absorbers can be cleaned periodically with a low powered vacuum cleaner. For cleaning guidance on removing stains, please refer to the treatment guide within the technical specification. Suitable applications for the SuperPhon Wall System and Panels include: Recording studios Audiology rooms Commercial premises Offices Reception areas Cinemas and theatres Call centres and conferences rooms Public entertainment facilities SuperPhon Suspended Absorbers offer a cost effective and high quality solution for the following: Schools Leisure centres Exhibition centres Offices Physical information SuperPhon Wall System and Panels Thickness: 25mm and 50mm Other thicknesses available on request Max panel size: Weights: 3000 x 1200mm Subject to fabric limitations 3.25kg/m 2 for 25mm panel 5.00kg/m 2 for 50mm panel SuperPhon Suspended Absorbers Size: 1200 x 600 x 50mm Other sizes available on request Colours: 40 standard colours Other colours are available on request

Technical Specification CMS SuperPhon wall coverings To ensure effective sound absorption is achieved, noise surveys and anticipated reverberation times pre- and postinstallation should be carried out. Random incidence sound absorption coefficients are tested to BS EN ISO 354: 2003. Independent tests undertaken by Sound Research Laboratories Limited. Test data available on request. Absorber Frequency / Thickness 125 250 500 1k 2k 4k NRC Classification* 12mm panel 0.05 0.10 0.35 0.60 0.75 0.85 0.45 D Solid back 25mm panel 0.07 0.31 0.76 1.02 1.09 1.10 0.80 C Solid back 25mm panel 0.11 0.42 1.01 1.12 1.09 1.08 0.90 C 25mm air gap 25mm panel 0.18 0.55 1.13 1.10 1.05 1.02 0.95 B 50mm air gap 25mm panel with 0.10 0.37 0.93 0.99 0.90 0.82 0.80 C two simulated posters on face 50mm panel 0.32 0.90 1.15 1.10 1.09 1.10 1.05 A Solid back 50mm panel 0.35 1.04 1.21 1.15 1.10 0.98 1.15 A 25mm air gap 50mm panel 0.41 1.02 1.15 1.10 1.03 1.00 1.10 A 50mm air gap *Calculated to EN ISO 11654:1997 Treatment guide Blood Grass C Oil Chewing Gum I Grease Paint - water based AFC Chocolate Ink - Ballpoint DE Paint - oil based AHDC Cooking Oils Ink - Fountain Sauces BCD Crayon/Colour Markers Lipstick BECD Shoe Polish BCD Drinks (Cola, Juices, Beer) Mildew C Urine Dust/Dirt Vacuum, Milk AE Vomit D then J or C Mud BC Wine A, add salt, C Excrement BC Nail Polish AG A Mop up excess as soon as possible. B Remove surplus with a knife edge or appropriate instrument. C Sponge with a solution of carpet shampoo working from well outside the stain in a circular motion towards the centre [this avoids spreading the stain]. Sponge afterwards with clean warm water and mop up excess moisture with a clean dry cloth or sponge. Allow to dry then brush gently with a soft cloth. If any stain remains, sponge with a solution of 1 part household bleach to 6 parts water. Rinse thoroughly after treatment. D Lightly sponge with household dry cleaning fluid and blot. Apply sparingly, as the substance may have an adverse effect on the adhesive. E Sponge with methylated spirits and blot dry. F Lubricate stain with glycerine or petroleum jelly. G Apply nail polish remover. The nail polish remover should not include lanolin or be of a greasy nature. H Sponge with turpentine or a substitute. I Freeze with ice cubes and scrape away when cold. J Clean with regular extractive carpet cleaner if possible. CMS SuperPhon Suspended Absorbers Frequency 125 250 500 1k 2k 4k Sound Absorption Coefficient 0.24 0.49 0.92 1.05 1.01 1.01 Equivalent Sound Absorption Area, m 2 1.8 3.6 6.6 7.4 7.4 7.4 Acoustic performance of SuperPhon Suspended Absorbers Noise Absorption Level 1.2 1.0 0.8 0.6 0.4 0.2 0 125 250 500 1000 2000 4000 Frequency (Hz) call 01925 577 711 www.cmsacoustics.co.uk

The CMS SuperPhon range is just one of a number of acoustic solutions available exclusively in the UK from CMS Acoustic Solutions call 01925 577 711 www.cmsacoustics.co.uk Northern Office: Unit 4 Eagle Park Eagle Park Drive Warrington. WA2 8JA t: 01925 577 711 f: 01925 577 733 Southern Office: Unit 9 Enterprise Way Wickford. SS11 8DH t: 01268 568 762 f: 01268 568 764 A MEMBER OF THE CMS GROUP