ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.



Similar documents
ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

1. Description. 2. List of Accessories included A B C F G H

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Please also see 10 golden rules for correct Saniflo installation on

For heavier duty macerator/pumping applications

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

INFRARED QUARTZ WALL HEATER

SunMaxx Solar Filling Station Operating Instructions

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

PLUMBING CARE AND REPAIR

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

Line to Refrigerator Ice/Water Dispenser

Meaco 30L and Meaco 40L dehumidifier instruction manual

Liquorice Kitchen Sink Tap

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

PBX Series Quick Fit Connector Bimetallic Steam Traps

SF15K SF05KSS, SF10KSS

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Operators manual Basic water heater

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Portable Air Conditioner

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

Conlift1, Conlift2, Conlift2 ph+

Apricot Kitchen Sink Tap

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Almond Kitchen Sink Tap

ATS Overhead Table Shelf System INSTRUCTION MANUAL

B150 Series Commercial Brewer. Direct Plumb Kit

Drayton Digistat +2RF/+3RF

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

MODEL INSTALLATION INSTRUCTIONS

Apricot Kitchen Sink Tap

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

Electric Mini Tank Water heaters GL GL 4 - GL 6+

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Model 1210C Battery Powered Pump Shown. Description

IMPORTANT SAFETY RULES TO FOLLOW

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

- 2 - IMPORTANT SAFETY REMINDERS

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Chill 4 Hole Bath Shower Mixer

SMD Rework Station TABLE OF CONTENTS

*h5h/7h$ù,5,7ø75(ùø0/(59(68.$d$./$5, <$1/,ù0217$-'$1.$<1$./$1$%ø/ø5 &ø+$=,$6/$d$/,ù0$67$1',h=(5ø1'( 7$ù,0$<,1,=

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER


Oil and Coolant Circulating Heating System. Model - OCSM

Almond Kitchen Sink Tap

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

This section gives you some helpful information and tips on running your home and the equipment in it.

VOYAGER 570G. 744A Sprayer Control

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

SERVICE MANUAL Order No.WH0911S001V0

Hydraulic control unit series

Heavy Duty Pressure Washer Kit RAC-HP021

Operating Instructions

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

Mechanical Services Standard Specification Above Ground Soil, Waste and Ventilation Pipes

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

User and Installer Handbook

100 Series Maxi Internal Filters. Instruction Manual

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

INSTALLATION INSTRUCTIONS FOR VW MK5

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

767 Diagnostic System

BeoLab 7-1 BeoLab 7-2. Guide

ClearView 100. Instruction Manual

Operating Instructions

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

EP ; WO2012/080751; GB

MIC-WKT and MIC-WKT-IR

Assembly and instructions

Installation Instructions

MCR1900 Media Converter 19-Slot Chassis

Hot Water Urns. all models. Helpline. v3.0

Transcription:

1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to ISO 9001(2000) accredited by AFAQ. The correct operation of your unit depends on correct installation and usage. Please pay particular attention to the following: Possible danger to personnel Warning of possible electrical hazard ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit. This equipment benefits from the latest technological innovations concerning soundproofing. To benefit fully from the advantages provided by this new generation of appliances, it is important to comply with the installation instructions in section 5. Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 2. List of Accessories included x1 x1 x1 A B C H x1 Discharge elbow Hose clip for discharge elbow 32 x 50 90 x 110 Hose clip for WC pan spigot Optional Euro 22-32mm reducer I x1 x2 x2 x4 J K M Discharge hose 20 x 32 Floor mounting bracket Discharge hose clip Rubber feet

3. Dimensions and overall measurements This pump/macerator has been designed to pump away the waste from a WC. This unit is for domestic use only. Installed and used correctly, this unit will give consistent and reliable service. You can find the technical data in step 8. 4. Performance Curve & Height and Length of the discharge pipe 8 7 6 5 EN 12050-3 ø 32 The discharge pipe size for Saniflo can be 22mm or 32mm. Metres 4 3 2 1 0 0 10 20 30 40 50 60 70 80 90 litre/min 4m 3m 1% 2m 1m 0m 10m 20m 40m 60m 80m 90m

5. Installation J M J WARNING: The unit must be connected to WC pan with a horizontal outlet spigot conforming to EN33 or EN 37. The unit should be accessible for possible service. It is supplied with floor fixing lugs to prevent it from moving during use. To optimise the latest technical developments concerning soundproofing incorporated into this unit, it is important to: Position the WC pan so that it is not in contact with a partition or wall of the room. Place the WC pan on a perfectly level surface to ensure that the resilient mounts are fully efficient. Fix the discharge pipe correctly, with distances of not more than one metre between the fastenings. 6. WC Connection 1 2 C First, put some silicon or liquid soap on the WC spigot. Fit the collar supplied on the bowl outlet. Pull the flexible sleeve over the pan spigot. Position the metal hose clip (C) over the edge of the flexible sleeve and tighten with a screwdriver. Once the appliance has been positioned, fix it to the floor using the 2 screws (J) supplied. WARNING! There should be no water dripping from the WC cistern. If there is, this will cause the unit to activate repeatedly as it pumps the water away. The Saniflo unit and all its connections should be easily accessible for possible maintenance / removal.

7. Connection of discharge pipework K K A I K A I H B H Insert the discharge elbow (A) into the rubber discharge pipe which raises up through the lid, turn to the desired direction and secure with the metal hose clip provided (32-50mm) (B). Then connect the hose to it using the 20-32mm metal hose clip (K), making sure the hose is not kinked. 8. Technical advice for discharge pipework 1 2 Vertical before horizontal 3 1% 4 Air Admittance Valve 5 6 100/110mm 22mm 25/28mm 32mm 40mm 1 Horizontal pipe runs must have a minimum fall of 1:100 (10mm per metre) to the soil stack. 2 If a vertical lift is required, it must be made before the horizontal run at the start of the piperun. 3 We would recommend that a drain-off point is installed to allow the discharge pipework to be drained down before any service work. 4 If the discharge pipework runs to a level considerably lower than the unit, the resultant siphoning effect can suck out the water seal in the unit. Fitting an air admittance valve capable of withstanding 10psi pressure (BBA approved) at the high point of the pipe run will overcome this problem. 5 Ensure all external pipework is adequately lagged to avoid the possibility of freezing. 6 The discharge pipework must be connected to the soil stack using an appropriate strap on boss. N.B.: Any elbow on the discharge pipe of the unit will create friction loss (roughly 50cm per elbow to be deducted from the vertical pumping specification). Always use smooth bends (or 2 x 45 degree bends together) and not 90 degree elbows. Note. The discharge pipework should be copper or rigid solvent weld plastic.

1% 9. Electrical connection The electrical installation should be carried out by a qualified person. All wiring must conform to BS7671, 1992 requirements for electrical installations. The Saniflo requires a 220/240V single phase AC 50 Hz supply (UK specification). Do not connect the Saniflo to a conventional plug and socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The Saniflo has an earth wire. The wires in the mains lead are coloured in accordance with the following code: Brown Live Blue Neutral Green/Yellow Earth Warning: Ensure the electricity is turned OFF at the main switchboard before wiring to connector. All work on cable, pressure chamber and motor should only be carried out by a qualified Saniflo servicing agent, as special tools are required. UK 230/240V 50Hz. The unit should be installed so it is easily accessible/removable for possible maintenance. The unit should not be exposed to splashing in normal use. CANADA USA EUR CH GB 10. Norms This appliance conforms to EN 12050-3. Lifting plant for waste water containing faecal matter for limited applications and the European directives and standards concerning electrical safety and electromagnetic compatibility. SANIPLUS Société Française d Assainissement EN 12050-3 LA01-x10 220-240 V - 50 Hz - 550 W - IP44 2,9A - - 5,4 KG 11. Commissioning the unit Once electrical and plumbing connections have been made, flush the WC once. The motor should run from 5 to 10 seconds (sometimes in several small bursts) to clear the waste (depending on the height of the pipe run). If it runs for more than 20 seconds, check that the pipework is clear, and that the discharge hose is not kinked. Flush the WC checking that all seals, and connections are watertight. Check the discharge pipework from the unit.

12. Usage and Warning WARNING! If away for long periods (e.g. holidays) we recommend that you turn off the water supply to the WC served by the unit. WCs connected to this unit can be used like any normal toilet, and it requires minimum maintenance. The unit will operate automatically as soon as the required level of water enters the case. This unit is designed for use in the domestic environment. WARNING! Only the disposal of toilet paper, faecal matter, and waste water will be under guarantee. Any damage due to foreign bodies such as cotton, condoms, sanitary towels, wet wipes, food, hair, metal, wood or plastic objects, will not be under guarantee. Solvents, acids and other chemicals can also cause damage to the unit, and will invalidate the guarantee. 13. Care of your unit In order to remove scale and clean the macerator and the bowl, use a household descalent (like SANIFLO descaler). As a general rule, household disinfectants and bleaches designed for a normal WC are suitable for use with a Saniflo unit. Disconnect the macerator power supply. Pour an amount of descalent / bleach in the pan. Flush the WC once. Leave it to stand for 1 or 2 hours. Re-connect the macerator power supply. Rinse by operating the flushing system twice. Carry out the operation once every 3 months on average, but the frequency may need to be changed depending on the hardness of the water. 14. Maintenance DISCONNECT THE ELECTRICAL POWER SUPPLY, BEFORE ATTEMPTING ANY WORK ON THE UNIT. No need of any particular maintenance. This unit is fitted with an active carbon filter, and requires no external venting. This filter has to be changed every year.

15. Fault Finding / Remedies For the most past, any inconsistencies in the operation of the unit will be minor and easily rectified. Please refer to the chart below. IN ALL CASES, YOU MUST DISCONNECT THE MACERATOR FROM THE POWER SUPPLY If the problem cannot be easily remedied in this way, please call our Service organisation. ALL WORK INVOLVING DISMANTLING OF THE APPLIANCE MUST BE CARRIED OUT BY AN APPROVED REPAIR AGENT SYMPTOMS PROBABLE CAUSES REMEDIES The unit stops The motor intermittently activates An object is blocking the blades The unit has been running for too long and the (self re-setting) thermal cut out has engaged The connected sanitary device is dripping The non-return valve is faulty Call approved service engineer. The unit will reset itself. Check the installation upstream Clean or replace the non-return valve (externally mounted) The water in the WC pan goes down very slowly and is pumped away in bursts The air vent (under carbon filter) is clogged up The WC pan is partially blocked Clear the air vent. Clear the WC pan The motor operates normally, but continues to run for a long time The length or height of the installation is over the specification, or there are too many bends/elbows The pump chamber is blocked Check the installation Call approved service engineer The motor does not activate The electrical power supply is not active The motor or the control system is defective Restore the electrical supply Call approved service engineer The motor emits a rattling or crunching sound, hums, but does not run Foreign object in the box Problem with the motor or the control system Call approved service engineer

16. Removal 2 1 4 3 6 5 DISCONNECT THE ELECTRICAL POWER SUPPLY BEFORE ANY SERVICE REMOVING THE UNIT FROM THE WC SUITE 1 Disconnect the electrical power supply. 2 Turn off the water feed to the WC cistern. Bail out as much water as possible from the cistern. 3 Drain down any vertical discharge pipework and remove discharge hose from elbow. 4 Disconnect any inlet pipes from the unit. 5 Unscrew the 2 fastening screws (to the floor) if fitted. 6 Loosen the metal clip securing the flexible connector and pull off the WC spigot, now slide the unit out from behind the WC. 17. Guarantee 2 years guarantee as from its date of purchase subject to correct installation and correct use.

18. Parts