www.kaeser.com Refrigeration Dryers SECOTEC Flow rate 0.6 to 14.3 m³/min



Similar documents
Rotary Screw Compressors SM Series With the world-renowned SIGMA PROFILE Free air delivery 0.28 to 1.52 m³/min, pressures 5.

Rotary Screw Compressors SK Series

Compressed Air Filters KAESER FILTER Flow rate 0.60 to m³/min

Rotary Screw Compressors SK Series

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

Rotary Screw Compressors CSD / CSDX Series With the world-renowned SIGMA PROFILE Flow rate from 1.05 to m³/min, Pressure 5.

Electronic Condensate Drains ECO-DRAIN Series

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min.

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

Rotary Screw Compressors ESD Series

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Rotary Screw Compressors ASD Series With the world-renowned SIGMA PROFILE FAD 2.09 to 5.51 m 3 /min, Pressure 5.

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Kompressoren. Adsorption Dryer AD

Adsorption air dryers ADS 1 215

With the world-renowned OMEGA PROFILE

Compressed Air Filters

ThermoSorb Desiccant Dryers

Workshop Compressors CLASSIC Series

ThermoStar Refrigeration Air Dryers

Refrigeration Compressed Air Dryer Buran Ultrapulse

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Innovative to the Core

ETC -SV. Class 0 oil-free compressed air through catalysis

Refrigerated Air Dryers. Catalogue

Refrigeration Air Dryers. Catalogue

Rotary screw compressors kw 5,5 7, , bar MODULO

Sigma Frequency Control

Compressed Air Engineering

Screw Compressors ESM Fixed Speed & VS Variable Speed

Atlas Copco Quality Air Solutions. Compressed Air Filters

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

ECOCIAT. Domestic hot water heat recovery unit

Air Treatment Solutions

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

REFRIGERATED COMPRESSED AIR DRYERS

Medical Air Systems: Scroll

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

CONDENSATE MANAGEMENT

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

Pro Dry Heatless dessiccant compressed air dryers

Kompressoren. Oil Water Separators OWS

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

ultrafilter HEATLESS HL Adsorption Dryer

Portable Compressors. MOBILAIR M 13 M 350 With the world-renowned SIGMA PROFILE Flow rate 1.2 to 34.0 m³/min ( cfm)

Desiccant Air Dryers Heatless, Heated and Heated Blower

Technical data. Danfoss DHP-A

DRYPOINT RA REFRIGERATION DRYER RANGE

industry revolves around

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Thermostatic valve Type AVTA

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

NITROX // safer diving

Nirvana. Cycling Refrigerated Dryers

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

Screw Compressors. S Series. Capabilities from: 8.8 to 89 cfm Pressures from: 80 to 217 psig.

Basic Hydraulics and Pneumatics

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Split units TH with hermetic compressors

At A Glance... Products for a complete air system

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

Rotary Screw Compressors UP-Series 4 & 5.5 kw

Compressed air systems. How to plan, install and operate. Best Practices for Maintenance Management

CRAC Precision climate control units for data centres

Concept WVM Brief description. Effi cient compressed-air adsorption dryer with vacuum regeneration. NEW! Now with improved ZDMC2

Clinic Washer-Disinfectors. Washer-Disinfector Line

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA (VSD) ( kw/ hp)

High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

Compressor Service & Maintenance Manual

Series IDU/IDF. Refrigerated Air Dryer

IV. Rear Mount System

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

Are these noise cancelling devices needed to make your chiller quiet??

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Compressed air conditioning

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

GA GA VSD

Chilled Water Precision Air Conditioner For Critical Application

Dehumidification Frequently Asked Questions

Meeting Your Compressed Air Treatment Needs

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1


SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

AIRROLLAIR COMPRESSORS E

Rotary Screw Compressor. MSM MINI 2, ,5 kw

ROTARY SCREW COMPRESSOR. RMD kw

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

Medical Air Plant. uair Series (7-145 l/s / cfm)

Screw Compressors 11-22kW


Pressure Dew Point Probe / Application Information

In-Line Filters and Coalescers with Automatic Drains

Transcription:

Refrigeration Dryers Flow rate 0.6 to. m³/min

Energy savings all day, every day SECOTEC refrigeration dryers SECOTEC refrigeration dryers reliably remove the moisture from compressed air while minimising energy consumption. They feature premium quality components to ensure a long and dependable service life. The cycling control enables significant energy savings. Made in Germany: All SECOTEC refrigeration dryers are built in accordance with the very highest quality standards at KAESER s plant in Gera. Reliable compressed air drying As with all KAESER products, SECOTEC dryers are designed and built for maximum reliability. The broad range of available models makes it possible to install the most suitable dryer for virtually any application. Premium components High quality, generously-sized components (e.g. in the condenser) ensure optimum flow at all times even at high operating temperatures and guarantee a long and dependable service life. Details such as the use of smooth-bore copper piping in the refrigeration circuit also contribute to exceptional system effi ciency. Impressive performance and efficiency KAESER KOMPRESSOREN s innovative SECOTEC system is a true energy-saver when it comes to compressed air drying: unlike most refrigeration drying systems, KAESER SECOTEC energy-saving dryers consume power only when air actually needs to be dried thanks to their highly effi cient cycling control. Perfect for compressor stations Every SECOTEC dryer is EN 600- compliant and is tested for electromagnetic compatibility. Unlike equipment conforming to VDE 0700, SECOTEC dryers conform to a strict industrial standard and are equipped with a control cabinet to IP 5, a control transformer and fuses for the control and power circuits. The whole system is designed with maximum safety and reliability in mind. Reliable refrigerant circuit The refrigerant circuit in SECOTEC TF refrigeration dryers is specially designed for effi cient use of R-a refrigerant. This ensures maximum effi ciency and reliability, even at higher temperatures. Image: SECOTEC TB 9

Quality counts SECOTEC with thermal mass Hot gas bypass continuous control Reliable refrigerant circuit The refrigerant circuit in SECOTEC TF refrigeration dryers is specially designed for efficient use of R-a refrigerant. This ensures maximum effi ciency and reliability, even at higher temperatures. Saves energy: SECOTEC control The SECOTEC cycling control signifi cantly reduces energy consumption compared with conventional systems with continuous control. The refrigeration circuit is activated only when cooling is actually required. Image: SECOTEC TE Minimal pressure drop SECOTEC series dryers ensure minimal pressure drop thereby saving additional energy, as the required maximum pressure is reduced. No pre-filter SECOTEC energy-saving dryers do not require a pre-filter (with piping unaffected by corrosion). This translates into significantly lower investment and maintenance costs, as well as a lower pressure differential. 5

Quality engineered Efficient condensate separator KAESER s corrosion-free stainless steel condensate separators provide dependable compressed air drying and ensure reliable condensate separation even at partial load. This is especially important for compressor systems with standby dryers. Control cabinet to EN 600- The electrical components in SECOTEC dryers are designed and built in accordance with European standard EN 60- and applicable EMC standards. The dustand splash-proof IP 5 enclosure ensures maximum safety and durability at all times. Dependable condensate drainage Fitted as standard (except for the TA 5 model), the ECO-DRAIN is equipped with an intelligent levelsensing control that prevents pressure loss when the condensate is drained from the air system. Dependability to + C Thanks to perfectly matched refrigeration circuit components, SECOTEC dryers provide dependable performance at ambient temperatures of up to + C. 6 Image: TE 6 internal view 7

Easy to maintain Maintenance-friendly design All components in SECOTEC dryers are easily accessible. Furthermore, the condenser is located at the front of the dryer, which allows possible dirt accumulation to be quickly spotted and rectified. Excellent accessibility The SECOTEC refrigeration dryer s enclosure covers are quick and easy to remove. The tower design makes maintenance a breeze, which signifi cantly reduces servicing requirement and therefore costs. Easy-to-test refrigeration circuit KAESER service technicians and our partners technical staff are refrigeration technology experts. They not only check operation of the refrigeration dryer, but also of the cooling circuit itself using intake- and pressure-side service valves. Dependable condensate drainage Condensate drains play a key role in ensuring dependable operation of SECOTEC energy-saving dryers. The electronic ECO-DRAIN condensate drains are therefore subject to regular scheduled maintenance and inspection. 8 9

The energy-saving effect of the system Air consumption over a -hour period Compressed air / Energy consumption 00 % 90 % 80 % 70 % 60 % 50 % 0 % 0 % 0 % 0 % 0 % Time Early shift Midday break Additional energy-saving potential (for use at summer temperatures, e.g. ambient temperature 0 C) Energy saving potential Day shift Air consumption Designed for use in ambient temperature The SECOTEC advantage: Below the blue line: Air consumption Above the blue line: Energy-saving potential Night shift 6 - - - 6 C 0 C 5 C 0 C 5 C The TE 9 dryer, for example, can save a total of approximately 785 per year with single shift operation compared to dryers which use hot gas bypass control. This cost saving is calculated as follows: (8760 h - 000 h) x.5 kw x 0.0 /kwh = 785 The graph shows a typical compressed air consumption profile. SECOTEC dryers save energy because the refrigerant system is shut down during breaks, periods of low demand and downtime the control system operates without fixed run-on periods. The integrated thermal mass ensures that the system is always ready for operation. 0

Equipment General design Tower construction with removable side panels, sheet steel panelling powder-coated outside and galvanised inside; all cold components insulated; all materials CFC-free; the built-in control cabinet is enclosure-protected to IP 5, air to air heat exchanger (model TA 8 upwards); condensate separation system, automatic condensate drain; scope of delivery includes refrigerant and oil. Operating panel Equipped with dew point trend gauge, emergency stop switch, LEDs to indicate Thermal mass active and Refrigerant compressor ON. LEDs for High dew point and ECO- DRAIN alarm are fi tted as standard on TE models and upwards. TF models and upwards feature two operating hours counters. Refrigerant circuit Refrigeration circuit features large heat exchanger surface area and service valves, SECOTEC cycling control with thermal mass and automatic dew point control. Installation example Installation example For generally consistent air demand, the SECOTEC refrigeration dryer is located downstream from the air receiver. For heavily fl uctuating air demand, the SECOTEC dryer is located between the compressor, centrifugal separator with condensate drain and air receiver. General design Compressed air outlet Compressed air inlet Example: TE series Air/air heat exchanger Air/refrigerant heat exchanger with thermal mass Condensate separator ECO-DRAIN condensate drain Installation example Refrigerant Refrigerant Refrigerant compressor Refrigerant condenser Capillary tubes Filter / dryer High pressure switch Low pressure switch Fan pressure switch PDP trend indicator Large compressor systems requiring large volumes of high quality compressed air must have in-built redundancy as part of their design. Sophisticated compressed air supply systems designed and installed from a fully integrated perspective by KAESER s compressed air experts provide longterm durability and effi ciency with lowest possible life-cycle costs. Compressed air inlet/outlet

Technical specifications Dimensions Masse Abmessungen Dimensions W B x T D x H Compressed Druckluft air Connection Anschluss Compressed Druckluft air Elektrische Electrical Versorgung connection Refrigerant Masse Kältemittel mass Refrigerant Masse Kältemittel mass als as CO Äquivalent equivalent Modell Model* *) Volumenstrom Flow rate Pressure Druckverlust loss, Kältetrockner refrigeration dryer Elektrische Electrical power Leistungsaufnahmsumption con- bei at 00 % load Vol. Elektrische Electrical power Leistungsaufnahmsumption con- bei at 50 % load Vol. Connection Anschluss Condensate Kondensatablass drain hermetischer Hermetic refrigeration Kältekreislauf as i.s. def. circuit F-gases F-GaseVO reg. TA series Front view Rear view Left view Right view -D view m³/min bar kw kw Kg kg mm G G/DN kg t TA 5 0.60 0.07 0.9 0.6 70 0.7 0. 0 V / 60 x 8 x TA 8 0.85 0. 0.7 0.5 80 ¾ G ¼ Ph / 779 0. 0. 779 TA.5 0.7 0.8 0.5 85 0.6 0.5 8 60 TB 9.0 0.9 0.55 0.0 08 0.60 0.9 0 V / 60 x 50 x DN 0 Ph / 96 ¼ TB 6.55 0.0 0.6 0. 6 0.58 0.8 TB series TC.0 0.5 0.75 0. 55 0.76. 0 V / 76 x 660 x DN 0 TC 6.90 0.6 0.88 0.8 70 ¼ Ph / 0.97. 009 ¼ 96 TC.70 0.5 0.89 0.9 00..6 50 60 TD 5 5.65 0. 0.86 0.7 5.5.8 TD 6 7.00 0.5.0 0.6 5 ½ 00 V / 5 x 759 x DN 0 Ph / 87 ¼.8.8 TC series TD 76 8.5 0.7.0 0.77 87.50. TE 9 0.5 0.5.5 0.6 570.90.7 009 TE.70 0.8.5 0.80 660 00 V / 50 x 060 x xdn 0 Ph / 5 ¼.0.0 TE.0 0..60 0.88 660.0.0 660 77 *) Suitable for ambient temperatures from + to + C. Max. compressed air intake temperature +55 C; Gauge pressure min./max. to 6 bar Performance characteristics at reference conditions to ISO 78 Option A: Operating pressure 7 bar, ambient temperature +5 C, compressed air inlet temperature +5 C, pressure dew point + C. The fl ow rate changes for deviating operating conditions. Contains fl uorinated greenhouse gas R-a (GWP =,0). TD series Correction factors for deviating operating conditions (flow rates in m³/min x k...) Deviating working pressure p at dryer inlet 87 Modell p bar(ü) (g) 5 6 7 8 9 0 5 6 TA-TE TA-TF k p 0.75 0.8 0.90 0.95.00.0.07.0..5.7.9.. 759 5 Compressed air inlet temperature T i Modell Ti e ( C) 0 5 0 5 50 55 TA-TE TA-TF k Te.0.00 0.8 0.7 0.60 0.9 k Ti Ambient temperature T a Modell Ta u ( C) 5 0 5 0 TA-TE TA-TF k Tu.00 0.99 0.97 0.9 0.9 k Ta TE series Calculation of flow rate under deviating operating conditions: Selected refrigeration dryer: TB 9 with. m³/min (V Reference ) Example: 5 Working pressure: 0 bar (g) Compressed air inlet temperature: 0 C Ambient temperature: 0 C Table Table Table k p =.0 k Ti = 0.8 k Ta = 0.99 V max. operation = V Reference x k p x k Ti x k Ta V max. operation =. m³/min x. x 0.8 x 0.99 =.9 m³/min 060 50 5

www.kaeser.com Choose the required grade of treatment according to your field of application: Explanation Application examples: Selection of treatment classes to ISO 857- (00) Air treatment with refrigeration dryer Solids Water Pure air and clean room technology, dairies, breweries Food and beverage production, ultra-clean conveying air, chemical plants Pharmaceuticals industry, weaving machines, photo labs Paint spraying, powder coating packing, control and instrument air General factory air, high-grade sand blasting Shot-blasting Conveying air for wastewater systems, no quality specifications Oil Installation for fluctuating air demand KD ACT ZK Activated carbon adsorber AQUAMAT AQUAMAT DD Desiccant dryer Air-main charging system Air receiver ECD ECO-DRAIN KA Activated carbon filter, adsorption KB Coalescence filter, Basic KBE Extra combination KD Particulate filter, dust Coalescence filter, Extra A Carbon combination RD Refrigeration dryer THNF Bag filter ZK Centrifugal separator Compressed air quality classes to ISO 857-(00): RD A RD Optional filtration ACT ED Compressor THNF Solid particles/dust 0. d 0.5 0 AQUAMAT 7 KB With KAESER rotary screw compressors 6 7-X Max. particle count per m³ * of a particle size d in [μm] 5 0.5 d.0.0 d 5.0 Please consult KAESER regarding specific requirements > 0,000 00,000 00 6,000 90,000 0 00,000 0,000 00,000 Particle concentration Cp in mg/m³ * 6 7 X 0 < Cp 5 5 < Cp 0 Cp > 0 Water Compressed air treatment with desiccant dryer Pure air and clean room technology, pharmaceuticals, dairies, breweries Microchip production, optics, food and semiluxury food production Paint spraying installations Process air, pharmaceuticals Especially dry conveying air, paint spraying, fine pressure controllers - - Oil KD ACT - - 0 Please consult KAESER regarding specific requirements 5 6 70 C 0 C 0 C + C + 7 C + 0 C Concentration of liquid water CW in g/m³ * 7 8 9 X CW 0.5 0.5 < CW 5 5 < CW 0 CW > 0 A DD - ZK KBE DD Optional filtration Pressure dew point, in C Compressor THNF KD ) Achievable particle class at proper pipe system and commissioning. ) Achievable total oil content when using recommended compressor oils and clean inlet air. ) Downstream of heat-regenerated desiccant dryers, high-temperature filters are required, and an aftercooler if required. ) In critical applications requiring high compressed air purities (e.g., electronics and optics), we recommend the use of an Extra combination (filter combination of KB and downstream filter). AQUAMAT Oil Total oil concentration (fluid, aerosol + gaseous) mg/m³ * 0 Please consult KAESER regarding specific requirements X 0.0 0..0 5.0 > 5.0 *) At reference conditions 0 C, bar(a), 0% humidity KAESER KOMPRESSOREN SE P.O. Box 960 Coburg GERMANY Tel +9 956 60-0 Fax +9 956 600 e-mail: productinfo@kaeser.com www.kaeser.com P-0ED Specifications are subject to change without notice..6/5 Solids Water Installation for fluctuating air demand