OVERVIEW OF STANDARD 7E & STANDARD 20



Similar documents
Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

OPERATIONAL STANDARD

Guidelines for Selecting and Using ISTA Test Procedures and Projects

Cold Chain Shipping: Protecting Temperature Sensitive Products. Diane McLean Pfizer Global Manufacturing

A Complete Drug Stability Program. Stability Lab Information Manager SL IM

Developing Temperature Controlled Environmental Test Standards

The Application of Electronic Records and Data Analysis for Good Cold Chain Management Practices

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET

INTRODUCTION. This book offers a systematic, ten-step approach, from the decision to validate to

A Stability Program for the Distribution of Drug Products

The Impact of 21 CFR Part 11 on Product Development

THERMAL INSULATION MATERIALS

Validation and Calibration. Definitions and Terminology

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

IMP management at site. Dmitry Semenyuta

ALACC Frequently Asked Questions (FAQs)

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Inspections: Central Laboratory of the Regions

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Considerations When Validating Your Analyst Software Per GAMP 5

Temperature mapping of storage areas Technical supplement to WHO Technical Report Series, No. 961, 2011

Packaging for the Less-than-Truckload Environment

Title:: Effective GMP AUDITS for APIs and Formulation Pharma Companies By G.Sundar-Director/Consultant PharmQA Compliance solutions

Calibration of temperature control and monitoring devices

Implementing New USP Chapters for Analytical Method Validation

CSZ s EZ-View Software

Lifecycle Management of Analytical Procedures; What is it all about? Jane Weitzel Independent Consultant

TOTAL QUALITY MANAGEMENT II QUALITY AUDIT

Concremote calibration box

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

The Advantages & Challenges of Phase Change Materials (PCMs) In Thermal Packaging. Author Richard M. Formato, R&D Manager Cold Chain Technologies

Defining Quality. Building Comfort. Heating and Cooling Coils

Data Quality. Tips for getting it, keeping it, proving it! Central Coast Ambient Monitoring Program

Check-list for auditors. Audit visit at candidate registered laboratories

Meeting the FDA s Requirements for Electronic Records and Electronic Signatures (21 CFR Part 11)

Analytical Test Method Validation Report Template

ORACLE PROCESS MANUFACTURING QUALITY MANAGEMENT

Best Practices in RFID Tag Quality Assurance and Testing

Environmental Monitoring, Alarming & Reporting When Product Safeguards & Compliance are Required

VIBRATION DATA COLLECTION: A ROAD WORTH TRAVELING?

Documenting Distribution Operations: FDA Validation Beyond the Laboratory and Manufacturing Facility

Establishment of a Quality Systems approach to Clinical Site Management An Overview of Standard Operating Procedures (SOPs)

How To Ensure Quality Assurance

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

Best Practices for Reducing Transmitter Life Cycle Costs

PROTOCOL FOR BUILDING ENERGY ANALYSIS SOFTWARE For Class 3, 5, 6, 7, 8 and 9 buildings

Wireless Data Logger Monitoring Systems

Texas Commission on Environmental Quality Page 1 Chapter Control of Air Pollution from Nitrogen Compounds

The President of Inductors Inc. is the senior executive responsible for operations.

Quality Assurance Procedures for Construction and Materials Sampling and Testing 14

Auditing as a Component of a Pharmaceutical Quality System

Ordering Drums for Hazardous or Non Hazardous Material Transportation

Procedure for Writing Technical Procedures

Monitoring manufacturing, production and storage environments in the pharmaceutical industry

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

Standard Practice for Quality Control Systems for Nondestructive Testing Agencies 1

Silicon temperature sensors. Other special selections are available on request.

QUALITY MANUAL GREAT LAKES INSTITUTE FOR ENVIRONMENTAL RESEARCH ANALYTICAL LABORATORIES. October 2008 Revision 08

Guidance for Industry

1 For more information T: / E: DAP@ul.com / W: ul.com/dap

Measuring instruments in industry.

COTS Validation Post FDA & Other Regulations

LyoBeta. R+D Freeze-Dryers

STANDARD OPERATING GUIDELINES: EVIDENTIAL BREATH ALCOHOL INSTRUMENT CALIBRATION

Surgi Manufacturing Quality Manual

New changes to cleanroom & clean air device classifications: ISO & 2

ICH Topic Q 1 A Stability Testing Guidelines: Stability Testing of New Drug Substances and Products

Example Specification for Concrete using Current Building Code Requirements

Supplier Requirements Manual M M 0 3

Guidance on Qualification of existing facilities, systems, equipment and utilities

Quality Agreement. by and between. Supplier Name. Address: and. Client Name: Address:

DNA Ladders shipped at ambient temperature reduce environmental impact and retain their quality and stability

Control No: QQM-02 Title: Quality Management Systems Manual Revision 10 07/08/2010 ISO 9001:2008 Page: 1 of 22

Temperature mapping of storage areas

1 Quality Assurance and Quality Control Project Plan

GOOD DOCUMENTATION AND QUALITY MANAGEMENT PRINCIPLES. Vimal Sachdeva Technical Officer (Inspector), WHO Prequalification of Medicines Programme

Process Validation for Medical Devices

QUALITY CONTROL AND QUALITY ASSURANCE IN CLINICAL RESEARCH

Simplicity. Reliability. Performance

COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS

Generic CMMS Quality Assurance Plan

ISO 9001:2008 QUALITY MANUAL. Revision B

ISO/IEC QUALITY MANUAL

21 CFR Part 11 Compliance Using STATISTICA

COMMERCIAL ITEM DESCRIPTION CUSHIONING MATERIAL, PACKAGING, CLOSED CELL FOAM PLANK

CALIFORNIA PUBLIC EMPLOYEES RETIREMENT SYSTEM STATEMENT OF INVESTMENT POLICY FOR GLOBAL EQUITY. October 13, 2014

unless the manufacturer upgrades the firmware, whereas the effort is repeated.

Mirador. Features include: Applications:

(WHO Technical Report Series, No. 961, 2011), Annex 9. Temperature and humidity monitoring systems for fixed storage areas 107

MEASUREMENT OF THE LNG DELIVERED AND THE GAS REDELIVERED

Jonathan Wilson. Sector Manager (Health & Safety)

9. Quality Assurance 9.1 INTRODUCTION 9.2 FIELD SAMPLING QUALITY ASSURANCE 9.3 ANALYTICAL QUALITY ASSURANCE Internal Quality Control

Guidance for Industry Computerized Systems Used in Clinical Investigations

PROCEDURE FOR FRESH APPLE AND PEAR EXPORTS FROM SOUTH AFRICA TO MEXICO. Responsibility: Service Manager: Special Shipments Name: Initial:

Combination Products. Presented by: Karen S. Ginsbury For: IFF March PCI Pharma

ISO17025 INTERPRETATION DOCUMENT FOR CEC TEST METHODS

Transcription:

Standard for Thermal Transport Packaging Used in Parcel Delivery System Shipment 7E 2 010 ISTA 7E Usage Modes VERSION DATE OCTOBER 2010 Initial Release ISTA, Distributing Confidence, Worldwide ISTA 7-Series tests have historically been a combination of thermal profile "simulations" and procedure protocols. This new 7E is different. It is a set of standard profiles based on exhaustive real world measurements made in the parcel shipping environment. 7E is specifically designed to be used with a companion testing procedure, Standard 20. 7E may be used as a standalone profile set for proprietary testing procedures. If the user desires the tested package to be certified by ISTA in the context of 7E, Standard 20 must be acquired and followed in testing. This document presents the 7E Standard Profile set in graphic and digital format. No testing procedures are a part of this 7E Profile document. OVERVIEW OF STANDARD 7E & STANDARD 20 Use of 7E with proprietary testing procedures Standard 20 + Standard 7E = ISTA Certification of a Thermal Transport Package Standard 20 Standard 7E is designed to evaluate the effects of external temperature exposures of individual packaged-products shipped through a parcel delivery system. It can be used as a standalone profile standard. As such, it is useful for general testing and qualification of insulated shipping containers. When it is used in conjunction with ISTA Standard 20, its usefulness is enhanced: It can be used for the development of temperature controlled transport packages made of any material. It can be used for individual or comparative performance analysis of standard or insulated transport packages against normally encountered conditions. It can provide a measure of the relative ability of a package to protect a product when exposed to test cycles that simulate both the range and time of exposure to ambient temperature conditions. It allows the testing laboratory to submit results to ISTA for certification that the package conforms to testing according to Standard 20 using the 7E standard profiles. Packages so certified can legally bear the ISTA 7E Thermal Certification Mark. ELEMENTS OF STANDARD 20: Qualification of a design and testing operation to certify packages to 7E requires all three of the elements of Standard 20: Training At least one Certified Thermal Professional Level I and one Certified Thermal Professional at Level II must be active in the performance and reporting of tests. ISTA provides testing and training procedures for this element. Laboratory Protocols Documentation of testing protocols, data packages and reports in a specified format is required. The Standard 20 document provides everything needed for this aspect of compliance. Laboratory Audit Successful completion of an onsite laboratory audit by Certified ISTA Thermal Transport Lab Auditor is required. Important Notes IMPORTANT NOTES ABOUT STANDARD 20: Standard 20 is not intended to evaluate the protection afforded packaged-products from shock, vibration and/or compression. While physical testing is called for, the results are intended to evaluate physical impact on thermal performance. The cycle profiles in 7E are general simulations not intended to represent the worst case thermal exposure in the small parcel shipment environment. Many variables affect the thermal and distribution performance of a package and the ambient exposure profile extremes found in the distribution environment for each distribution situation can vary. ISTA profiles for all of the lanes used in the averaging procedures for the generation of the 7E profile set are available. Contact ISTA as indicated below for the availability of these lane-specific profiles. If testing is for compliance with specific government, industry, laboratory, validation or regulatory standards or guidelines that would supplement or supersede this procedure or if the value of the product or the liability of damage is significant, other ISTA Procedures may be appropriate for different conditions or to meet different objectives. ISTA 7E 2010 - Page 1 of 5

Applicability and Use APPLICABILITY AND USE: Applicability: The ISTA documents outlined here, 7E, Standard 20 and Standard 14 are recommended for use in supporting an FDA regulated organization s compliance activities relative to the Center for Drug Evaluation and Research ( CDER) guidelines on process validation as applied to an insulated shipping container (ISC) thermal performance. Reference the following compliance documents: Guidance for Industry, Q7A Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients ICH, 2001. CDER website, http://www.fda.gov/downloads/drugs/guidancecomplianceregulatoryinformation/guidances/ucm079645.pdf Use: ISTA documents provide the means to comply with both internal and external quality system requirements through individual (Certified Thermal Professional) certification, thermal transport laboratory certification (Standard 14), and ISC design qualification (Standard 20). The ISTA documents provide the user with a standardized methodology for demonstrating the performance of an insulated shipping container against a real world set of shipping lane temperature data, which has been statistically analyzed to create a robust thermal profile. Benefits End Result Benefits to Industry of a new thermal profile and ISC qualification process: What it is--- A complete insulated shipping container (ISC) qualification tool for industry application and subsequent regulatory submission, as required. What it is not o customized shipping lane data o customized worst case shipping qualification Who benefits End user, purchaser of ISC designs and products o Off the shelf, independently certified packaging solution that meets industry requirements with the requisite qualification data to support high value pharmaceutical/biopharmaceutical manufacturers and global regulators. o Supply chain optimization through selection of the most competitive ISC solution(s) for the most economical shipping lanes. o Reduction in cost and time to market by selecting pre-qualified ISC designs. Internal resource demands are minimized and focused on product development activities. o Internal laboratories benefit from improved efficiency in executing thermal performance testing. Supplier of ISC designs and products o Supply markets will open up and provide a more level playing field by providing designs which can be compared based on performance data, cost and service levels. o Facilitates and encourages new product development and innovation as there will exist an industry accepted methodology to demonstrate benchmark thermal performance for new ISC products. Contract test laboratories o Industry standardization via ISTA 7E and Standard 20 deployment will increase the demand for independent test laboratories certification activities (Standard 14); and the resultant value of the independent test laboratory within the marketplace is increased. o Standardization and supporting qualification documentation greatly improves the laboratory s efficiency in completing high quality work for their clients. End result: ISTA reviews ISC qualification results and issues the Standard 20 certification mark for the ISC design. A complete ISC qualification documentation package is achieved and ready for regulatory submission, as required. Additionally, laboratories are certified for thermal performance testing via Standard 14 and qualified ISC designs can be listed on the ISTA.org website, readily available for purchasers of ISC s for commercial use. An essential element of Standard 20 is the consistency of approach and the consistency of documentation. Certification CERTIFICATION USING STANDARD 20: Users seeking ISTA 7E Certification for their packages must employ 7E Profiles according to the requirements and all of the specific procedures set forth in Standard 20. Using 7E Profiles without acquiring and complying with Standard 20 will not qualify any tested package for certification. Contact ISTA for specifics of Standard 20: pricing, acquisition and necessary steps for certification. Go to www.ista.org or contact ISTA at (+1) 517.333.3437 ISTA 7E 2010 - Page 2 of 5

Sequence STANDARD 20 TESTING SEQUENCES: Sequence Design Thermal Qualification Physical Qualification Thermal Qualification Verification What is being tested Initial laboratory testing to affirm that the design is performing according to user requirements is performed using 7E profiles. (May be repeated to refine designs for achieving user requirements). Laboratory testing to affirm accuracy and repeatability of Design is performed using 7E profiles. Laboratory testing to affirm package integrity is sufficient to assure thermal performance is performed using ISTA physical testing standards. Field testing to affirm that laboratory thermal testing results are repeatable in field conditions is performed using sensor placement determined by prior laboratory testing. The testing sequences are set forth in detail in the documentation of Standard 20. Standard 20 is a suite of documents that provide everything that a laboratory or design team will need to get a package to the point of submission for ISTA approval and certification. Standard 20 CONTENTS OF THE STANDARD 20 DOCUMENT: Document ISTA Designation Contents Standard 20 Main Document STD-0020 A complete set of instructions for laboratory procedures, equipment requirements, calibration, setting of acceptance criteria, documentary standards and data handling requirements for the 7E profiles to be applied according to Standard 20 Design Protocol APPX-0023 An outline of the protocol document for Design Thermal Design Report APPX-0024 The form and requirements for reporting results of Design Thermal Design Data Package Example APPX-0026 A complete example of illustrating the requirements of a Design Data Package Thermal Qualification Protocol APPX-0027 An outline of the protocol document for Thermal Qualification. Thermal Qualification Report APPX-0028 The form and requirements for reporting results of Thermal Qualification Physical Qualification Protocol APPX-0031 An outline of the protocol document for Physical Qualification Physical Qualification Report APPX-0032 The form and requirements for reporting results of Physical Qualification Thermal Verification Protocol APPX-0035 An outline of the protocol document for Thermal Qualification Thermal Verification Report APPX-0036 The form and requirements for reporting results of Design Thermal Continued on next page ISTA 7E 2010 - Page 3 of 5

Continued from previous page Document History File Template APPX-0039 An outline of the user document presenting the results of testing to Standard 20 ISC Qualification Program Worksheets FORM-0046 A compilation of worksheets that are part of the Data Packages Significant Figures and Rounding SOP-0039 A thorough explanation of data handling techniques for significant figures and results that conform to quantitative user requirements Good Documentation Practice SOP-0044 A thorough explanation of required standards for signatures, authorities for document approval and exceptions handling. ISTA 7E 2010 - Page 4 of 5

7E Used Standalone TESTING USING 7E STANDALONE The profile set provided here represents annual Heat and cold seasonal maxima and minima for a parcel shipping environment. Users who intend to employ their own testing procedures are encouraged to consider using Standard 20 as a procedure standard for testing. If users do not determine a need for Standard 20, the following guidelines are recommended. Recommendations Samples should be the untested actual package and product, but if one or both are not available, the substitutes shall be as identical as possible to actual items. The product and package should be considered together and not separately. Substituted products should be as close as possible in regard to content, composition, thermal mass, consistency (e.g. liquid, powder, or paste), and other physical properties, and be packaged in the product specific primary package. It is recommended that the simulated packaged-product tested be as close as possible in its specific heat to the actual product so that changes in temperature of both materials would occur at the same rates. If a refrigerant or temperature stabilizer is used, it shall be the exact type that will be used by the shipper. To permit an adequate determination of representative performance of the packaged-product, ISTA recommends that the procedure to be performed a minimum of one time, preferably three or more times using new samples with each test. Packages that have already been subjected to the rigors of transportation cannot be assumed to represent standard conditions. In order to insure testing in perfect condition, products and packages shipped to laboratories for testing should be: over-packaged for shipment to the laboratory, or re-packaged in new packaging at the laboratory. Temperature Conditioning: Draft-free Room or Chamber and Control apparatus complying with the apparatus section of ASTM D 3103. Temperature Indicators complying with the apparatus section of ASTM D 3103. It is important to measure and document the package + product: gross weight in pounds (kg), and outside dimensions of Length, Width and Height (L x W x H) in inches (mm or m) CAUTION: Level of Performance Standardization establishes a rule or measure for quality and level of performance. The 7E standard was developed by characterizing the transport environment and developing Heat and Cold profiles to test packaging configurations with a high degree of confidence. These test profiles are science-based with data to support their claim and are designed to replicate known and anticipated environmental conditions in a parcel distribution network. The profiles are presented in Heat and Cold and for 72 hour and 144 hour durations. The user is referred to ISTA document ISTA Report 0043 ISTA Global Heat and Cold Profiles for an explanation of the relationship of these profiles to the full suite of temperature measurements. Standard 20 allows for a temperature profile tolerance of ±3.0 C (above or below the Profile value for each hourly interval). This is indicated in the graphs that follow. The average temperature of the profile used must have an average value that is ±1.0 C relative to the mean temperature for the 7E profile average value. If a programmed chamber profile test results fit within the indicated envelope, as shown in the graphs and in the tabular data, and it produces a mean temperature value within the limits, then it is considered to be a valid 7E profile. Important: The full text version of 7E, including the heat and cold profiles, is available for separate purchase by contacting ISTA Headquarters at 1-517-333-3437, or by visiting the ISTA website at www.ista.org. ISTA 7E 2010 - Page 5 of 5