ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.



Similar documents
ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

1. Description. 2. List of Accessories included A B C F G H

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Please also see 10 golden rules for correct Saniflo installation on

For heavier duty macerator/pumping applications

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

PLUMBING CARE AND REPAIR

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

SunMaxx Solar Filling Station Operating Instructions

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

INFRARED QUARTZ WALL HEATER

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Liquorice Kitchen Sink Tap

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Chill 4 Hole Bath Shower Mixer

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Operators manual Basic water heater

SF15K SF05KSS, SF10KSS

Thermostatic bar showers. Troubleshooting and maintenance

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Line to Refrigerator Ice/Water Dispenser

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

*h5h/7h$ù,5,7ø75(ùø0/(59(68.$d$./$5, <$1/,ù0217$-'$1.$<1$./$1$%ø/ø5 &ø+$=,$6/$d$/,ù0$67$1',h=(5ø1'( 7$ù,0$<,1,=

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Almond Kitchen Sink Tap

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

PBX Series Quick Fit Connector Bimetallic Steam Traps

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

AL-System 6 AQUALOOP System 6. Installation and operating instructions WATER IS OUR ELEMENT.

Portable Air Conditioner

Apricot Kitchen Sink Tap

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

This section gives you some helpful information and tips on running your home and the equipment in it.

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Meaco 30L and Meaco 40L dehumidifier instruction manual

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

Conlift1, Conlift2, Conlift2 ph+

Almond Kitchen Sink Tap

B150 Series Commercial Brewer. Direct Plumb Kit

IMPORTANT SAFETY RULES TO FOLLOW

MODEL INSTALLATION INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR VW MK5

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Drayton Digistat +2RF/+3RF

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Apricot Kitchen Sink Tap

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.

CERTIFYING DRAINLAYER

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

LUCCI AIRFUSION QUEST II CEILING FAN

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

SERVICE MANUAL Order No.WH0911S001V0

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

100 Series Maxi Internal Filters. Instruction Manual

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

XONYX Solid Surface Owner's Manual

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

Installation Instructions

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Shower Handbook (Also covers 650 chrome variant)

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Heavy Duty Pressure Washer Kit RAC-HP021

Installation Instructions

Installation Instructions S

- 2 - IMPORTANT SAFETY REMINDERS

Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References

Saferand easierinstallation

Please read and keep these instructions. Run water through your machine before first use

Model 1210C Battery Powered Pump Shown. Description

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

User and Installer Handbook

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

NAVIEN AMERICA INC FITCH AVENUE

SMD Rework Station TABLE OF CONTENTS

ATS Overhead Table Shelf System INSTRUCTION MANUAL

12. Design of plumbing systems for single dwellings

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Transcription:

1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to SO 9001(2000) accredited by AFAQ. The correct operation of your unit depends on correct installation and usage. Please pay particular attention to the following: Possible danger to personnel Warning of possible electrical hazard ATTENTON This is a general warning that failure to follow instructions could result in poor functioning of the unit. This equipment benefits from the latest technological innovations concerning soundproofing. To benefit fully from the advantages provided by this new generation of appliances, it is important to comply with the installation instructions in section 5. Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 2. List of Accessories included x1 x5 x1 x1 A C D Discharge elbow Hose clip for discharge elbow 32 x 50 90 x 110 Hose clip for WC pan spigot lanking off inlet cap x2 x1 x1 x2 E F G H nlet connector Optional Euro 22-32mm reducer Discharge hose Floor mounting bracket x2 J x4 Discharge hose clip 20 x 32 Rubber feet

Ø46mm 36mm 282mm 263mm 3. Dimensions and overall measurements 91mm 413mm 47mm 180mm 66mm This pump/macerator has been designed to pump away the waste from a WC and the sanitary appliances in step 1. This unit is for domestic use only. nstalled and used correctly, this unit will give consistent and reliable service. You can find the technical data in step 9. 4. Performance Curve & Height and Length of the discharge pipe 8 7 6 5 EN 12050-3 ø 32 The discharge pipe size for Sanipro can be 22mm or 32mm. Metres 4 3 2 1 0 0 10 20 30 40 50 60 70 80 90 100 110 litre/min 5m max 4m 3m 1% 2m 1m 0m 10m 20m 40m 60m 80m 90m 100m

5. nstallation H J H Warning: The unit must be connected to WC pan with a horizontal outlet spigot conforming to EN33 or EN 37. The macerator and its connections is integral with the WC pan itself. The unit should be accessible for possible service. t is supplied with floor fixing lugs to prevent it from moving during use. To optimise the latest technical developments concerning soundproofing incorporated into this unit, it is important to: Position the WC pan so that it is not in contact with a partition or wall of the room. Place the WC pan on a perfectly level surface to ensure that the resilient mounts are fully efficient. Fix the discharge pipe correctly, with distances of not more than one metre between the fastenings. 6. WC Connection 1 2 C First, put some silicon or liquid soap on the WC spigot. Fit the collar supplied on the bowl outlet. Pull the flexible sleeve over the pan spigot. Position the metal hose clip (C) over the edge of the flexible sleeve and tighten with a screwdriver. Once the appliance has been positioned, fix it to the floor using the 2 screws (H) supplied. Warning! There should be no water dripping from the WC cistern or any other sanitary appliances. f there is, this will cause the unit to activate repeatedly as it pumps the water away. The Sanipro unit and all its connections should be easily accessible for possible maintenance / removal.

7. Connections of extra sanitary appliances 1 E Plugging side inlet D Closed 2 See figs 1 and 2 for connections that may be required for sanitary appliances. E 8. Connection of discharge pipework G A A G F A F nsert the discharge elbow (A) into the rubber discharge pipe which rises up through the lid, turn to the desired direction and secure with the hose clip provided (32-50mm) (). Then connect the hose to it using the 20-32mm hose clip (), making sure the hose is not kinked.

9. Technical advice for discharge pipework 1 2 Vertical before horizontal 3 1% 4 Air Admittance Valve 5 6 100/110mm 22mm 28mm 32mm 40mm 1 Horizontal pipe runs must have a minimum fall of 1:100 (10mm per metre) to the soil stack. 2 f a vertical lift is required, it must be made before the horizontal run at the start of the piperun. 3 We would recommend that a drain-off point is installed to allow the discharge pipework to be drained down before any service work. 4 f the discharge pipework runs to a level considerably lower than the unit, the resultant siphoning effect can suck out the water seal in the unit. Fitting an air admittance valve capable of withstanding 10psi pressure (A approved) at the high point of the pipe run will overcome this problem. 5 Ensure all external pipework is adequately lagged to avoid the possibility of freezing. 6 The discharge pipework must be connected to the soil stack using an appropriate strap on boss. N.. Any elbow on the discharge pipe of the unit will create friction loss (roughly 50cm per elbow to be deducted from the vertical pumping specification). Always use smooth bends (or 2 x 45 degree bends together) and not 90 degree elbows. Note. The discharge pipework should be copper or rigid solvent weld plastic. 1% Ø 28 / 32 / 40mm 120mm min. max. 5m Ø 22 / 28 / 32mm 2nd possibility for connection of wash basin Ø 40 3%

10. Electrical connection The electrical installation should be carried out by a qualified person. All wiring must conform to S7671, 1992 requirements for electrical installations. The Sanipro requires a 220/240V single phase AC 50 Hz supply (UK specification). Do not connect the Sanipro to a conventional plug and socket. t must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The Sanipro has an earth wire. The wires in the mains lead are coloured in accordance with the following code: rown Live lue Neutral Green/Yellow Earth Warning: Ensure the electricity is turned OFF at the main switchboard before wiring to connector. All work on cable, pressure chamber and motor should only be carried out by a qualified Saniflo servicing agent, as special tools are required. UK 230/240V 50Hz. The unit should be installed so it is easily accessible/removable for possible maintenance. The unit should not be exposed to splashing in normal use. CANADA USA EUR CH G 11. Norms This appliance conforms to EN 12050-3. Lifting plant for waste water containing faecal matter for limited applications and the European directives and standards concerning electrical safety and electromagnetic compatibility. SANPRO XR Société Française d Assainissement EN 12050-3 LA03-p30 220-240 V - 50 Hz - 400 W - P44 1,9A - - 6,5 KG 12. Commissioning the unit Once electrical and plumbing connections have been made, flush the WC once. The motor should run from 5 to 10 seconds (sometimes in several small bursts) to clear the waste (depending on the height of the pipe run). f it runs for more than 20 seconds, check that the pipework is clear, and that the discharge hose is not kinked. Flush the WC checking that all seals, and connections are watertight. Check both the discharge pipework from the unit and the other sanitary appliances connections. When pumping the water away from a washbasin or shower, the unit will run in short bursts with an interval between each one. 13. Usage and Warning Warning! f away for long periods (e.g. holidays) we recommend that you turn off the water supply to the WC served by the unit. WCs connected to this unit can be used like any normal toilet, and it requires minimum maintenance. The unit will operate automatically as soon as the required level of water enters the case. This unit is designed for use in the domestic environment. Warning! Only the disposal of toilet paper, faecal matter, and waste water will be under guarantee. Any damage due to foreign bodies such as cotton, condoms, sanitary towels, wet wipes, food, hair, metal, wood or plastic objects, will not be under guarantee. Solvents, acids and other chemicals can also cause damage to the unit, and will invalidate the guarantee. 14. Care of your unit n order to remove scale and clean the macerator and the bowl, use a household descalent (like SANFLO descaler). As a general rule, household disinfectants and bleaches designed for a normal WC are suitable for use with a Saniflo unit. Disconnect the macerator power supply. Pour an amount of descalent / bleach in the pan. Flush the WC once. Leave it to stand for 1 or 2 hours. Re-connect the macerator power supply. Rinse by operating the flushing system twice. Carry out the operation once every 3 months on average, but the frequency may need to be changed depending on the hardness of the water.

15. Maintenance DSCONNECT THE ELECTRCAL POWER SUPPLY, EFORE ATTEMPTNG ANY WORK ON THE UNT. No need of any particular maintenance. This unit is fitted with an active carbon filter, and requires no external venting. This filter has to be changed every year. 16. Fault Finding / Remedies For the most part any inconsistencies in the operation of the unit will be minor and easily rectified. Please refer to the chart below. f the problem cannot be easily remedied in this way. Please call our Service organisation. N ALL CASES, YOU MUST DSCONNECT THE MACERATOR FROM THE POWER SUPPLY f the problem cannot be easily remedied in this way, please call our Service organisation. ALL WORK NVOLVNG DSMANTLNG OF THE APPLANCE MUST E CARRED OUT Y AN APPROVED REPAR AGENT SYMPTOMS PROALE CAUSES REMEDES The unit stops The motor intermittently activates An object is blocking the blades The unit has been running for too long and the (self re-setting) thermal cut out has engaged The connected sanitary devices are dripping The non-return valve is faulty The unit will reset itself Check the installation upstream Clean or replace the non-return valve (externally mounted) The water in the WC pan goes down very slowly and is pumped away in bursts The air vent (under carbon filter) is clogged up The WC pan is partially blocked Clear the air vent Clear pan The motor operates normally, but continues to run for a long time The length or height of the installation is over the specification, or there are too many bends/elbows The pump chamber is blocked Check the installation The motor does not activate The electrical power supply is not active The motor or the control system is defective Restore the electrical supply The motor emits a rattling or crunching sound, hums, but does not run Foreign object in the box Problem with the motor or the control system Cloudy water comes up into the shower tray (units with side inlets) Shower installed too low as compared with the macerator unit Hinged side inlet discs clogged up Check the installation Clean the hinged discs (see section 17)

17. Removal 2 1 3 5 4 6 DSCONNECT THE ELECTRCAL POWER SUPPLY EFORE ANY SERVCE REMOVNG THE UNT FROM THE WC SUTE 1 Disconnect the electrical power supply. 2 Turn off the water feed to the WC cistern. ail out as much water as possible from the cistern. 3 Drain down any vertical discharge pipework and remove discharge hose from elbow. 4 Disconnect any inlet pipes from the unit. 5 Unscrew the 2 fastening screws (to the floor) if fitted. 6 Loosen the hose clip securing the flexible connector and pull off the WC spigot, now slide the unit out from behind the WC. HNGED SDE NLET VALVES CLOGGED Remove the sleeves and use a screwdriver to free or clean the rubber flaps if necessary. 18. Guarantee 2 year guarantee as from its date of purchase subject to correct installation and usage.

19. Parts