Syringe. Product Usage Information: Precautions:

Similar documents
I-140 Venipuncture for Blood Specimen Collection

To maintain a port of entry to venous flow when all available peripheral ports have failed.

Administration of Meropenem For Child

Introcan Safety. 1 billion times protection. Vascular Access

Policy and Procedure Flushing and / or Blood withdrawal Aspiration Procedure For PICC Line and Midline Catheters

Needlestick Injury Prevention Assessment Tool

Within the Scope of Practice/Role of APRN RN _ X_LPN CNA

Objectives At the completion of this module, unlicensed assistive personnel (UAP) should be able to:

PROCEDURE FOR SUBCUTANEOUS INSERTION, REMOVAL, MEDICATION ADMINISTRATION AND FLUID ADMINISTRATION FOR COMMUNITY PALLIATIVE CARE PATIENTS

Policies & Procedures. ID Number: 1118

ClikSTAR - Important facts about your new insulin delivery device.

Healthcare Waste Management Training

Attachment D Infection Control Policy METHODS OF IMPLEMENTATION AND CONTROL

Giving safe injections

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

MISSISSIPPI BOARD OF NURSING IV THERAPY COURSE FOR THE EXPANDED ROLE LICENSED PRACTICAL NURSE COURSE OUTLINE

Use and Disposal of Sharps

Promoting safer use of injectable medicines

BLOOD CULTURE COLLECTION GUIDELINES FOR PHLEBOTOMISTS (WITHIN REGION 6)

INSULIN INJECTION KNOW-HOW

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

PICC & Midline Catheters Patient Information Guide

CADD-legacy PCA pump Model ml Cassette

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

HUMULIN (HU-mu-lin) N

How To Prepare and Give a Prefilled Syringe Injection

Definitions. This plan. membrane, These are. additions and. and. weeping a source of. withstand the. demands of to or from a

Policies & Procedures. I.D. Number: 1073

Medications or therapeutic solutions may be injected directly into the bloodstream

6.0 Infectious Diseases Policy: Student Exposure Control Plan

PICCs and Midline Catheters

POSSIBLE NURSING DIAGNOSIS: Pain Potential for Infection / Infection Fluid volume deficit

ON-Q * Catheters and Introducers

An introduction to the principles and practice of safe and effective administration of injections

FLORENCE TOWNSHIP BOARD OF EDUCATION FILE CODE: / Florence, New Jersey

(800) Cryo-Cell.com

DEPARTMENT OF HEALTH PO BOX 358 TRENTON, N.J

OSHA s Bloodborne Pathogens Standard

Grady Hospital Waste Management Program For Grady Health System. An Update

Section 6: Your Hemodialysis Catheter

Care of your peripherally inserted central catheter

Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home

Bloodborne Pathogens

1) Giving patient access and control over their health information

PATIENT GUIDE. Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL

Learning to Self Inject Methotrexate at Home Developed by Andy Thompson MD FRCPC and Marie J Craig-Chambers B.Sc.Phm

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

Health Care Workers in the Community

Insulin Administration by Syringe 10/24/2012 1

Peripheral Venous Catheter Placement Simulator

INJECTION TECHNIQUE. IVF NURSING OFFICE: (301) Darshana (301) Nicole

Administration of Medications & Fluids via a Peripheral Intravenous Cannula

TREATMENT 1. Control bleeding by applying pressure over wound with Gauze Pads (Surgical Supply-4). 2. Contact Surgeon for laceration repair options.

Blood Sampling in Sheep AS-557-W

Instructions for Use HUMALOG KwikPen insulin lispro injection (rdna origin)

VUMC Guidelines for Management of Indwelling Urinary Catheters. UC Access/ Maintenance

Step-by-Step Patient Injection Guide

NHA Certified Clinical Medical Assistant (CCMA)

BD Saf-T-Intima. Hidden talents of BD Saf-T-Intima. BD SAF-T-Intima and SUBCUTANEOUS THERAPY REHYDRATION PALLIATIVE CARE. POST OPERATIVe PAIN RELIEF

Corporate Safety Infection Prevention Employee Health

Central Line Blood Draw

Mock OSHA Inspection:

BLOODBORNE PATHOGENS EXPOSURE CONTROL PROGRAM

IVF CLASS. IVF NURSE CONTACT INFORMATION: Darshana , Nicole ,

Lancet Device Incident Investigation Report

Tell your doctor about all the medicines you take, including prescription and nonprescription medicines, vitamins, and herbal supplements.

Instructions for Use

8/6/2010. Name of medication Concentration (1:1,000 or 1mg/1ml) Expiration date

Instructions for Use PROCRIT (PRO KRIT) (epoetin alfa)

Your Guide to Peritoneal Dialysis Module 3: Doing Peritoneal Dialysis at Home

My Doctor Says I Need to Mix Insulins... How Do I Begin? BD Getting Started. Mixing Insulins

New 7/1/2015 MCFRS 1

POLICY 08:18:00 BLOODBORNE PATHOGENS CONTROL PLAN

Pediatric Blood Draws HELEN MAXWELL

X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary

How to Care for your Child s Indwelling Subcutaneous Catheter

HYFLAM D3: Report of Scenarios 08/02/2012

Medication Administration Quick Guide

A P P E N D I X SAMPLE FORMS

Blood Borne Pathogen Exposure Control Plan Checklist

Biliary Drain. What is a biliary drain?

Giving Yourself Dalteparin (Fragmin) or Heparin

Page 1 of 10 MC1482 Peripherally-Inserted Central Catheter. Peripherally-Inserted Central Catheter (PICC)

Safe Tattooing How is it done? Things to remember before getting a tattoo: What are the risks? Hepatitis B Hepatitis C: HIV/AIDS:

PATIENT INFORMATION. Medicine To Treat: D iabetes. What You Need to Know About. Insulin

3. Blood and blood products such as serum, plasma, and other blood components.

Disposable Insulin Delivery Device User Manual

Roger Williams University. Bloodborne Pathogens Exposure Control Plan

EAST CAROLINA UNIVERSITY INFECTION CONTROL POLICY

UW MEDICINE PATIENT EDUCATION. Using Insulin. Basic facts about insulin and self-injection. What is insulin? How does diabetes affect the body?

OCCUPATIONAL EXPOSURE TO BLOODBORNE PATHOGENS (29 CFR )

Guidelines for Viral Hepatitis CTR Services

Health Care Worker Health and Safety: Preventing Needlestick Injury and Occupational Exposure to Bloodborne Pathogens

INTERDISCIPLINARY CLINICAL MANUAL Policy and Procedure

PICC and Midline Catheters

Transcription:

Syringe Standard Draw Procedure In-Patient, Automated Retraction Non-Reusable. Prepare and give injection using aseptic technique according to institutional policy.. For injection into patients, continue depressing plunger to activate automatic needle retraction while needle is still in patient. For injection into IV ports, continue depressing plunger to activate automatic needle retraction and immediately remove needle from port. Full dose is administered only when needle retraction is activated.. Needle will automatically retract into syringe, preventing exposure to contaminated needle and rendering syringe non-reusable. In the event that needle retraction mechanism does not activate, discard syringe in an appropriate sharps container per protocol of institution. Do not recap contaminated needles.. Dispose of VanishPoint syringe in an appropriate sharps container per protocol of institution. Single use only. Reuse of this device may result in exposure to bloodborne pathogens, including Hepatitis B virus (HBV), Hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Contents are sterile, non-toxic, and non-pyrogenic. Do not use if product or package is damaged. Use only with attached needle. Needle cannot be changed. Automated needle retraction occurs only when barrel is emptied and plunger is fully depressed. For applications where full dose is not administered, expel remaining contents according to institutional policy and activate needle retraction. M00 Rev. 9 EN, JUL 0 00, 0 Retractable Technologies, Inc. All rights reserved.

Suggested Technique For TB Skin Testing Using ml VanishPoint Tuberculin Syringe. Prepare and give injection using aseptic technique according to institutional policy.. Using other hand, fully depress plunger to activate automatic needle retraction while needle is still in patient. Full dose is administered only when needle retraction is activated.. Needle will automatically retract into syringe, preventing exposure to contaminated needle and rendering syringe non-reusable. In the event that needle retraction mechanism does not activate, discard syringe in an appropriate sharps container per protocol of institution. Do not recap contaminated needles.. Dispose of VanishPoint syringe in an appropriate sharps container per protocol of institution. M0 REV. EN, AUG 0 00, 0 Retractable Technologies, Inc. All rights reserved.

U-00 Insulin Syringe Standard Draw Procedure In-Patient, Automatic Retraction Non-Reusable. Prepare and give injection using aseptic technique according to institutional policy.. For injection into patients, continue depressing plunger to activate automatic needle retraction while needle is still in patient. Full dose is administered only when needle retraction is activated.. Needle will automatically retract into syringe, preventing exposure to contaminated needle and rendering syringe non-reusable. In the event that needle retraction mechanism does not activate, discard syringe in an appropriate sharps container per protocol of institution. Do not recap contaminated needles.. Dispose of VanishPoint syringe in an appropriate sharps container per protocol of institution. Use U-00 Insulin only. Single use only. Reuse of this device may result in exposure to bloodborne pathogens, including Hepatitis B virus (HBV), Hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Contents are sterile, non-toxic, and non-pyrogenic. Do not use if product or package is damaged. Use only with attached needle. Needle cannot be changed. Automated needle retraction occurs only when barrel is emptied and plunger is fully depressed. M06 REV. EN, Aug 0 0, 0 Retractable Technologies, Inc. All rights reserved.

Blood Collection Tube Holder VanishPoint 5 6 VanishPoint VanishPoint Van. Securely thread multiple sample blood collection needle into tube holder. Remove needle cover when ready to use. Perform venipuncture per protocol of institution.. Insert blood collection tube into tube holder, pushing forward to start blood flow. Remove blood collection tube when filled and repeat with additional tubes as required. For small diameter tubes, use VanishPoint small diameter tube adapter with tube holder.. Once last tube has been removed and needle is still in patient s vein, close end cap securely into tube holder. 5. Needle will automatically retract from patient s vein into tube holder. In the event that needle retraction mechanism does not activate, discard tube holder in an appropriate sharps container per protocol of institution. Do not recap contaminated needles. 6. Dispose of tube holder in an appropriate sharps container per protocol of institution. Single use only. Reuse of this device may result in exposure to bloodborne pathogens, including Hepatitis B virus (HBV), Hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Do not use if product is damaged. For use with conventional multiple sample blood collection needles up to / (8 mm) in length. Not for use with winged needle sets or luer adapters. Do not attempt to remove blood collection needle from tube holder after retraction. M00 REV. EN, AUG 0 005, 0 Retractable Technologies, Inc. All rights reserved.

Blood Collection Set Select and prepare venipuncture site using aseptic technique according to institutional policy. For blood collection using a tube holder, thread the luer adapter into a tube holder, while ensuring winged hub remains tightly connected to adapter. For blood collection using a syringe, remove luer adapter and attach syringe. Dispose of luer adapter in an appropriate sharps container per protocol of institution. Holding device using the finger grips, carefully remove needle cover.. Perform venipuncture, observing for blood return in device. Collect blood specimen according to institutional policy.. Once blood collection is complete and the needle is still in the patient s vein, depress retraction trigger indicated by the color-coded arrow ( ).. The needle will automatically retract from the patient s vein into the device. In the event that needle retraction mechanism does not activate, discard blood collection set in an appropriate sharps container per protocol of institution. Do not recap contaminated needles.. Dispose of blood collection set and tube holder (or syringe) in an appropriate sharps container per protocol of institution. Do not remove tube holder from blood collection set. For blood collection using a syringe, transfer blood to appropriate specimen container per institutional protocol. Single use only. Reuse of this device may result in exposure to bloodborne pathogens, including Hepatitis B virus (HBV), Hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Do not use if product or package is damaged. Not made with DEHP. Not made with PVC. The VanishPoint blood collection set can be used for blood collection for diagnostic purposes or for short term IV administration, up to hours. The same set should not be used for both procedures. M05 REV. EN, MAR 0 0, 0 Retractable Technologies, Inc. All rights reserved.

I.V. Catheter Select and prepare site using aseptic technique according to institutional policy. Based on patient allergy information, select an antiseptic solution to disinfect the insertion site. Recommended solutions include: % chlorhexidine, 0% providoneiodine, 70% alcohol. Remove needle cover and inspect catheter unit.. Perform venipuncture, observing for blood return. Advance the catheter slightly to assure full catheter entry into the vein.. Holding the flashback chamber stationary, disengage the hub from the introducer needle and advance the catheter into the vein. DO NOT REINSERT THE NEEDLE INTO THE CATHETER AT ANY TIME.. Before withdrawing the introducer needle from the catheter, depress the color coded end of the needle housing to activate the automated retraction of the introducer needle. To activate the retraction mechanism using one hand, stabilize the color coded end of the needle housing against the proximal portion of the palm, while pulling back the housing using the finger grips.. The introducer needle will retract into the housing. In the event that needle retraction mechanism does not activate, discard catheter introducer in an appropriate sharps container per protocol of institution. Do not recap contaminated needles. Dispose of the introducer needle in an appropriate sharps container per protocol of institution. Securely connect tubing or adapter to the catheter hub, following the manufacturer s instruction for the device. Secure catheter and dress site per protocol of institution. Single use only. Reuse of this device may result in exposure to bloodborne pathogens, including Hepatitis B virus (HBV), Hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Do not use if product or package is damaged. To prevent exposure to contaminated needle, activate safety mechanism prior to withdrawing needle from catheter. Do not use scissors or sharp implements near I.V. catheters. Never reinsert the introducer needle into the catheter. Clinicians must follow instructions for use and be trained on proper product use. During catheter insertion, maintenance, replacement, and removal, follow current Guidelines for the Prevention of Intravascular Catheter-Related Infections, Centers for Disease Control and Prevention, Atlanta, GA. Notify physician immediately and follow facility protocols in the event patients exhibit symptoms of infusion-related complications. View from underside of palm M00 REV. EN, AUG 0 005, 0 Retractable Technologies, Inc. All rights reserved.