Implementing a Reliable Furnace Monitoring System



Similar documents
Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

SCADA Questions and Answers

Software INTERACT. MachineLogic. The Shortest Distance Between Man and Machine

SCADA and Monitoring for Solar Energy Plant

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

EnerVista TM Viewpoint Monitoring v7.10

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

Semaphore T BOX Applications in Data Center Facilities

Combined Cycle Control Overview

Configuring PROFINET

Siemens and National Instruments Deliver Integrated Automation and Measurement Solutions

G4 Digital DC Output Modules. G4 Digital DC Output Modules. Features. Description. Part Numbers

SCADAvantage Network Topology System software products

Introduction To SCADA and Telemetry

Radiological Assessment Display and Control System

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management

QUICK REFERENCE GUIDE MOBILE HUMAN MACHINE INTERFACE (HMI): INNOVATION THAT EMPOWERS THE MOBILE OPERATOR

1 nrsapre@gmail.com, 2 dr.s.m.kumar@gmail.com

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Complete SCADA solution for Remote Monitoring and Control

Field Products. Experion LX. Proven, Easy to Use and Purpose-built Distributed Control System

PLCs and SCADA Systems

Visualize, Document & Keep Your Network Running!

Bristol ControlWave Redundant Control

REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS

DSX-HSCS Hot Swap Comm Server

The Benefits of Component Object- Based SCADA and Supervisory System Application Development

AutoLog ControlMan. Remote Monitoring & Controlling Service

Square D Model 6 Motor Control Centers

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing

SPPA-T3000 Control System The Benchmark in Controls

Technical Training Module ( 30 Days)

SMS GSM Alarm Messenger

Industrial Control Solutions

Intelligent Vibration Monitoring

S m a r t M a s t e B T E C O R P O R A T I O N USER MANUAL

WinCon Programmable Automation. Controller

SHORT TRAINING COURSES

Monitoring & Control of Small-scale Renewable Energy Sources

NEW. EVEN MORE data acquisition and test stand automation

Process Control and Automation using Modbus Protocol

Remote monitoring & control solutions for cathodic protection rectifier

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Operator Station Software Suite

Accelerating your engineering workflow. Engineering solutions for industry

H.V.A.C. Design Plumbing Design

Ovation Controller Data Sheet

Reconfigurable Integrated Production Control System of Industrial Processes on QNX Neutrino Platform***

Communication on a higher plane. Simulation Package for Test System Integration. Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik

ETERE SNMP CONSOLE: A centralized, automatic and real-time monitoring of broadcast system networks

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)

PROFIBUS/PROFINET System design

Technical Service Bulletin

Web Studio HMI Software Used to Automate Home

Control of Boiler Operation using PLC SCADA

EZ-View Network Communications Guide

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

Introducing: BioXpert. Supervisory Control and Data Acquisition Software

Bioreactor Process Plant Powered by NI LabVIEW and NI CompactRIO

HMI and Industrial PC Solutions

EUROTHERM MASTER COMMUNICATIONS 5000 Series with Master Communications for unsurpassed access to process data everywhere

INFORMATION UNIFICATION BE- TWEEN ENTERPRISE RESOURCE PLANNING SYSTEM AND PRODUC- TION CONTROL SYSTEM

High rate and Switched WiFi. WiFi QoS, Security 2G. WiFi a/b/g. PAN LAN Cellular MAN

PROBA 4. In control of banana ripening. World leaders in process control.

The Case for Intelligent Remote I/O. The Case for Intelligent Remote I/O. Wise Delegation for Your Automation System. Introduction

STERIDRY DRY HEAT Sterilization. Lower Cost, Worry-Free & Green WHY GRUENBERG DRY HEAT STERILIZATION?

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

AMICO Information. Management System (AIMS)

FUNDAMENTALS OF CONTROL ENGINEERING

A P P L I C A T I O N. Nutricia Polska. Control system for jar-packed baby-foods manufacturing department

Premium Server Client Software

Intrusion Detection and Cyber Security Monitoring of SCADA and DCS Networks

Communication Interface Units. CIU Prime & CIU Plus

CPUs - CPU PN/DP

The integrated HMI-PLC

Best Practises for LabVIEW FPGA Design Flow. uk.ni.com ireland.ni.com

Testing for the Unexpected: An Automated Method of Injecting Faults for Engine Management Development

Connectivity. PowerShield 3. Communications Software

SCADA, OPC and Database Systems

A Real Time, Object Oriented Fieldbus Management System

Copyright Copyright 2014 SerVision Ltd. All Rights Reserved.

Control of Computer Room Air Conditioning using Sensors in the IT Equipment. Energy Efficient Data Center Demonstration Project

Introduction to Data Acquisition

Industry White Paper. Ensuring system availability in RSView Supervisory Edition applications

ELM Security System Electronic Locking & Monitoring

Medical Vacuum Systems-PXMI

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

ADB Airfield Solutions Runway Guard Light System Operation

Understanding Programmable Automation Controllers (PACs) in Industrial Automation

LADDER LOGIC/ FLOWCHART PROGRAMMING DIFFERENCES AND EXAMPLES

Monitoring Underground Power Networks

OpenControl. Utilization

ProducTVity Station. Real-time performance monitoring for the factory floor. And beyond.

Transcription:

Category: Manufacturing Implementing a Reliable Furnace Monitoring System Products Used: RT Series PXI (PXI 1002 And PXI 8156B) LabVIEW Real-Time by V. Arunachalam Sr. Project Engineer Anand Chinnaswamy Director & CTO Ganesh Devaraj, Ph.D. Managing Director Soliton Automation Pvt. Ltd. The Challenge: Implementing a reliable oven monitoring system that operates around the clock and unattended during the night, with supervisory control to shut down ovens that show signs of faulty operation. The Solution: Developing a highly reliable, flexible monitoring and supervisory control system, accessible via the Web. Using National Instruments RT Series PXI, distributed I/O modules, and LabVIEW Real-Time graphical development environment to monitor and record the process parameters in 20 ovens and initiate safety shutdown when necessary. Abstract We developed a highly reliable and flexible monitoring and supervisory control system using RT Series PXI, distributed I/O modules, and a PC running a LabVIEW application. The system monitored and recorded the process variables in 20 ovens and also activated the shutdown procedures in the event of any emergency. The LabVIEW Real-Time application running on PXI provides the reliability needed for this system, which operates around the clock and unattended during the night. The system is also Webenabled for remote viewing of the status and reports. Introduction The GE Medical Systems plant located in Bangalore, India, manufactures many critical components used to build sophisticated, high-value medical equipment. Some of these components are processed in ovens where both the temperature and vacuum are cycled according to predetermined recipes for up to 72 hr. Figure 1 shows the layout of the ovens in the plant. The oven manufacturer equipped each of the 20 ovens with a programmable logic controller (PLC) to control the numerous valves, vacuum pump, and sense operator inputs such as start and stop. A PID controller was incorporated for temperature control.

Figure 1: Layout of the Ovens in the Plant Because the ovens were purchased at different times and they came equipped with PLCs of different manufacturers, the customer found it difficult to link them to a central computer to automatically record the process values. Therefore, this procedure was conducted manually by periodically reading the local displays showing the temperature and vacuum. When the number of ovens increased to 20, the customer decided to establish an automated monitoring system. They called upon Soliton Automation to provide a solution. GE wanted their investment in the monitoring system to ideally give them the following features: Automatically record the process parameters from each of the ovens (temperature and vacuum) Raise alarms and automatically shut down the oven in case of an emergency (over temperature for example) Provide the reliability to operate around the clock and also unattended during the nights Perform as a highly flexible system which can be reconfigured and reprogrammed easily for monitoring different cycle profiles and different alarm conditions Offer remote access to the entire monitoring system across the Web The customer clearly wanted the flexibility, easy networking capabilities, and standardization provided by a Windows-bas ed monitoring system. However, they also mentioned that reliability was a serious concern because the system had to run continuously around the clock. National Instruments innovations kept pace with the market requirements because NI released LabVIEW Real-Time for the PXI. System Description A schematic of the networked furnace monitoring system (FMS) is shown in figure 2. The brain of the system is the RT Series PXI, which continuously monitors the oven parameters, checks them against the limits, and initiates appropriate actions when necessary. Because the ovens are distributed around the plant floor, distributed I/O modules are used for the remote data acquisition and control. A PC running a LabVIEW application provides the user interface that allows the operator to view the status of all

the ovens and also set up the different cycle profiles and alarm conditions. The PC also runs a Web-server that allows the detailed status and trends to be viewed over the Internet. RT Series PXI GE Intranet / Internet Ethernet switch PC with LabVIEW & Web server RS-232 Bank 1 RS-485 Bank 2 RS-485 Bank 5 OVEN 1 OVEN 2 OVEN 3 OVEN 4 OVEN 5 OVEN 6 OVEN 7 OVEN 8 OVEN 17 OVEN 18 OVEN 19 OVEN 20 Figure 2: Schematic Representation of the Networked Furnace Monitoring System The data acquisition from the ovens and the supervisory control is accomplished using distributed modules. Five banks of modules are used (depicted in figure 2) where each bank consists of a thermocouple module, an analog input module, a digital input module, and a relay module along with a RS-485 communications module. These modules are wired to the thermocouples, vacuum sensors, operator push buttons, audio alarms, and the main contactor feeding power to the ovens (for emergency shutdown). The RT Series PXI system polls all the inputs from the 20 ovens every 250 ms, and then checks them against the expected profiles and tolerance limits. If a problem is detected, an audio alarm is raised, and the oven is shut down if necessary. The temperature and pressure values are periodically transferred to a database on the PC. TCP/IP is used to transfer the data from the RT Series PXI to the PC and the LabVIEW application running in the PC writes this data into an SQL database. An IIS Web-server running on the PC displays Web pages showing the current status of all the ovens, parameter trends, and the history of the alarms for each oven using the data from the database (Figure 3). The PXI running LabVIEW Real-Time provides the necessary reliability for around the clock operation. If the PC or the Ethernet network connection fails, the RT Series PXI continues to perform monitoring and supervisory control and saves the measured data in the local 4 GB hard drive, while periodically rechecking the connection to the PC. After the connection is reestablished, the software applications running in the RT Series PXI and the PC work together to transfer the data to the database on the PC. Because the RT Series PXI has substantial hard drive capacity, no data is lost even if the PC is down for an extended time.

Figure 3: Oven Status across the Web System Benefits Comparison Parameter Productivity and Cost Earlier Manual System People required around the clock to monitor and log parameters RT Series PXI-Based System Fully automated Reliability and Safety Cannot ensure integrity of manually collected data; no redundant safety mechanisms Reliable data collection; supervisory control provides safe shutdown in case of malfunction Access to Oven Status and Scheduling Oven status updated only once every 30 min without convenient access for scheduling Continuous real-time access to the status of all the ovens, alarms, and trends, from any location via the company intranet and Internet; scheduling becomes easy Table 1: Comparison between the Earlier and New Systems Conclusion The customer wanted the reliability of a real-time operating system (RTOS), along with the benefits of the Windows operating system in terms of programming ease and networking standardization. The networked

furnace monitoring system built around RT Series PXI and has proven to be ideal for the application. Having never been exposed to an RTOS earlier, it would have been impossible for us to develop such a sophisticated system with all the features required by the customer and deploy it in 10 weeks without LabVIEW Real-Time. After the successful completion of this project, we confirmed that LabVIEW Real-Time provides both the reliability of an RTOS and the programming ease of LabVIEW.