Vortex AC. Refrigerant Recovery Machine



Similar documents
1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves

Air vacuum pump with r134a & r12/22

Dehumidifier Users manual. For Models: DH45S DH65S

, User s Manual

This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for AR512 series and SAE J2099 and J2210 for AR500 series

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

GAS SAFETY PRECAUTIONS

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

Visit our website at: our technical support at:

3 WATT LED SPOTLIGHT Model No. SLM

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

tire inflator with pressure gauge

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Cylinder Leak- Down Tester

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

COMPRESSED AIR DRYER

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

Recharge Procedure for Telemark TVP-2000 and TVP-3500

INSTANT HOT WATER RECIRCULATING SYSTEM

Compressor Service & Maintenance Manual

accidents which arise due to nonobservance and the safety information herein.

Leak Detection System

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

CARING FOR YOUR WATER HEATER

Bottom Loading Water Dispenser

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Customer Support

Get Me Cool Now Portable Air Conditioner User s Manual

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

The Storm 20-Gallon Wet/Dry Vac

Why and How we Use Capacity Control

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Operating Instructions Split System Air Conditioner

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

12-Volt 10-Amp Regulated Power Supply

Line to Refrigerator Ice/Water Dispenser

OPERATION MANUAL FOR REFRIGERANT RECOVERY WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Advantium 2 Plus Alarm

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

3000W Power Inverter

Ceiling Mount Air Handler Manual

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

4 in 1 Air Compressor

USER S MANUAL HSC-24A

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

NITROUS TRANSFER PUMP INSTRUCTIONS

Meaco 30L and Meaco 40L dehumidifier instruction manual

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Tools & Instruments. Totaline P920-RECOVERY115 Oil-Less Refrigerant Recovery Unit

VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

Operations and Maintenance Manual

PAINT SPRAY GUN WASHER

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Safety, Operation and Maintenance Manual with Parts List

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Addendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals

PNEUMATIC PLANISHING HAMMER

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

POWER TO GET THE JOB DONE

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Installation Manual DIAPHRAGM WELL TANK

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

PC1130 Electric Air Compressor

10ACC WARNING WARNING. Service Literature 10ACC SERIES UNITS

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

PC1131 Electric Air Compressor

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)

Single Phase Soft Starter

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

BroadBand PowerShield. User Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Test Code: 8297 / Version 1

United Technologies USER'S MANUAL. Split Type Room Air Conditioner

National- Spencer Inc.

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Installation and Operating Instructions (for chargers shown below)

LOBOY 16 AIR CONDITIONERS

8 ton air/hydraulic long ram jack

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Transcription:

O P E R A T I N G M A N U A L Vortex AC Refrigerant Recovery Machine

Thank you for buying the INFICON Vortex AC Refrigerant Recovery Machine! To get the best performance from your Vortex AC, please read this manual carefully before you start using the recovery machine. If you have any questions or need additional assistance, call 800-344-3304. We ll be happy to help you! Safety First! When found on the machine, this international symbol is intended to alert the user to the presence of important operating, safety and maintenance (servicing) instructions in this Manual. As used in the Manual, it is intended to draw your attention to critical items. It is important to read this entire Manual and be familiar with its contents before using the machine! The Vortex AC is a Recovery Machine for a broad range of refrigerants. Recovering refrigerants into a separate storage tank involves a process of gas compression, resulting in high pressures within the machine, the connecting hoses and the storage tank. High pressure systems must always be treated with care and respect to prevent careless accidents. EPA Certification The INFICON Vortex AC is an EPA Certified machine in accordance with Section 608 of the Clean Air Act. It has been independently tested and certified to be in conformance with ARI standard 740-1998 by Underwriters Laboratories Inc. Product Safety For the highest level of safety, the recovery operation should always be performed using a DOT approved storage tank with a shutoff switch (tank float) properly connected to the Vortex AC s Over Fill Protection circuit (available as an option). Additionally, approved refrigerant hoses must be used which have shut-off devices within 12 inches (304.8 mm) of the ends to reduce the likelihood of refrigerant leakage to the atmosphere when changing tanks or setups. Responsibility The INFICON Vortex AC must only be operated by a Qualified Technician who has been properly trained in the care and use of such equipment and in the recovery process itself. Use of this equipment by unqualified personnel is potentially dangerous and should not be attempted. Trademarks The trademarks of the products mentioned in this manual are held by the companies that produce them. INFICON, Vortex, Compass, D-TEK Select, TEK-Mate, and Wey-TEK are trademarks of INFICON. All other brand and product names are trademarks or registered trademarks of their respective companies. The information contained in this manual is believed to be accurate and reliable. However, INFICON assumes no responsibility for its use and shall not be liable for any special, incidental, or consequential damages related to the use of this product. 2004 All rights reserved. Reproduction or adaptation of any part of this manual without permission is unlawful. Preface

Table Of Contents 1.0 Safety Precautions............................. 2 2.0 Specifications, Features and Warranty............. 4 2.1 Vortex AC Specifications......................... 4 2.2 Warranty...................................... 5 3.0 Setup and Operation............................ 5 3.1 Getting Started................................. 5 3.2 Normal Recovery Operation....................... 6 3.3 PURGING the Vortex AC......................... 8 3.4 Push-Pull Operation............................. 8 3.5 Cooling The Recovery Tank....................... 9 3.6 Special Operating Notes......................... 10 4.0 Maintenance................................. 11 5.0 Troubleshooting.............................. 12 6.0 Service...................................... 13 6.1 General...................................... 13 6.2 Electrical Schematic............................ 15 7.0 EPA Requirements............................ 16 1

1.0 Safety Precautions THIS EQUIPMENT MUST ALWAYS BE OPERATED BY A QUALIFIED TECHNICIAN WHO IS FAMILIAR WITH REFRIGERANT SYSTEMS, REFRIGERANTS, REFRIGERANT SAFETY AND THE EPA REQUIREMENTS. READ THIS MANUAL and become familiar with the specifications and operation of this machine prior to use. WEAR APPROPRIATE SAFETY PROTECTION APPAREL such as gloves, eye protection and foot protection when working on refrigeration systems. REFRIGERANT VAPOR CAN BE HAZARDOUS AND ITS BY PRODUCTS CAN BE LETHAL work only in well ventilated areas. When working indoors, ensure there is adequate airflow in the work space and install a separate circulation fan if necessary. DO NOT WORK IN AN ENCLOSED AREA without special safety equipment as appropriate for the conditions. KNOW THE PROPER SAFETY AND HANDLING REQUIREMENTS for the Refrigerant being recovered by reviewing the Material Safety Data Sheets (MSDS) and the Temperature - Vapor Pressure information. PERFORM LEAK DETECTION in accordance with recommended practice only. For best results use only a refrigerant detector such as the INFICON D-TEK Select, Compass, or TEK-Mate. NEVER USE OXYGEN for this process as it can become an explosive mixture in the presence of oil and pressure. STORE REFRIGERANTS in a cool, dry place. SEPARATE DIFFERENT REFRIGERANTS. Avoid mixing refrigerants by using separate storage cylinders and filters for each type recovered. 2

NEVER OVERFILL A STORAGE CONTAINER. The safest approach is to use a DOT certified storage cylinder with a Tank Full cutoff switch that is properly connected to the Vortex AC s optional Over Fill Protection Circuit. If the storage cylinder does not have a cutoff switch, or if PUSH-PULL OPERATION is used, the use of a refrigerant scale, such as the INFICON Wey-TEK, is required to prevent overfill. OVERFILLED TANKS CAN RUPTURE EXPLOSIVELY! OPEN SERVICE OR CYLINDER VALVES SLOWLY to ensure that all connections are tight and there is no danger. DISCONNECT POWER before moving or servicing the INFICON Vortex AC. This unit should be opened only by a technically qualified person who has been trained in basic electronics and refrigeration. The risk of ELECTRIC SHOCK and exposure to HOT compressor parts is possible if the unit is opened. TO REDUCE THE RISK OF FIRE, EXTENSION CORDS SHOULD NOT BE USED with this equipment as the wiring can overheat under conditions of high current draw. If an extension cord is absolutely necessary, its length should be as short as possible and it should contain size 16 AWG or larger wiring. FLAMMABLE ENVIRONMENTS ARE DANGEROUS when any machine is used because motors and switches can generate sparks. This equipment should be used in locations with mechanical ventilation providing at least four air changes per hour, or the equipment should be located at least 18 above the floor. DO NOT USE THIS EQUIPMENT IN THE VICINITY OF SPILLED OR OPEN CONTAINERS OF GASOLINE OR ANY OTHER FLAMMABLE LIQUID. 3

2.0 Specifications, Features and Warranty 2.1 Vortex AC Specifications Refrigerants......................... EPA Certified to ARI 740-98 for R-134a, R-22, R407, R410A and all refrigerants listed under categories III, IV, & V in ARI standard 740-98. Power.............................. 115 V(ac), 60 Hz, 10 A Compressor:........................ 1/2 HP Oilless, No inlet valve, AC Motor Drive Cooling:............................ Fan driven off AC compressor motor Protection:.......................... High Pressure Switch Cutoff at 550 PSI Compressor motor thermally protected 80% Tank Full Shutoff available Pressure............................ Low side design pressure 240 PSI; High side design pressure 550 PSI Temperature........................ Operating Range 50 to 104 F (10 to 40 C) Case............................... Blow-Molded, High Impact Strength Size................................ 18 L X 9.5 W X 14.5 H (457.2 mm x 241.3 mm x 368.3 mm) Weight............................. 27.7 lbs. (12.6 kg) 4

2.2 Warranty Vortex AC Operating Manual INFICON warrants your Vortex AC Refrigerant Recovery Machine to be free from defects of materials or workmanship for three years from the date of purchase. INFICON does not warrant any machine that has been subjected to misuse, negligence, or accident, or has been repaired or altered by anyone other than INFICON. The Compressor is warranted for a period of three years by the manufacturer. To keep this WARRANTY in force it is required that a standard filter or filter drier be used on the Inlet Port or Hose at all times to prevent particulates from entering the compressor. FAILURE TO USE A FILTER WILL VOID THE COMPRESSOR WARRANTY. INFICON s liability is limited to machines returned to INFICON, transportation prepaid, not later than thirty (30) days after the warranty period expires, and which INFICON judges to have malfunctioned because of defective materials or workmanship. INFICON s liability is limited to, at its option, repairing or replacing the defective machine or part. This WARRANTY is in lieu of all other warranties, express or implied, whether of MERCHANTABILITY or of FITNESS FOR A PARTICULAR PURPOSE or otherwise. All such other warranties are expressly disclaimed. INFICON shall have no liability in excess of the price paid to INFICON for the machine plus return transportation charges prepaid. INFICON shall have no liability for any incidental or consequential damages. All such liabilities are EXCLUDED. 3.0 Setup and Operation 3.1 Getting Started Only personnel who have been properly trained in the use and operation of Refrigeration Systems, Refrigerants and Service Equipment should operate this equipment. Failure to follow proper safety precautions could result in personal injury or death. Review the full contents of this Manual before attempting to use the Vortex AC in actual service. Install an approved filter on the inlet. Attach the hoses per the diagram below. The Vortex AC has a female refrigerant flare fitting so that it may accept a filter with male flare fittings, the hoses then attach to the filter. DO NOT USE AN ADAPTER FITTING IN PLACE OF A FILTER AS THIS MAY CAUSE DAMAGE TO THE VALVES AND VOID THE WARRANTY. 5

Connect the AC Power cord to a circuit that is protected by a 15 amp breaker. Use an extension cord only when absolutely necessary to perform the service be sure it is the minimum length required, that it contains a safety ground wire and that it contains wires sized 16 AWG or larger. When recovering refrigerant, it may be necessary to throttle the Manifold Gauge control valve(s) or the Vortex AC s INLET Valve when a significant amount of liquid is present. This is required if a loud knocking sound is heard from the compressor. While the Compressor in the Vortex AC is tolerant of liquid, no compressor will run on 100% liquid without damage for more than a few minutes. In addition, a liquid slug can cause the High Pressure shutoff to activate, thus adding time to the process. It is thus important to open the valves slowly and monitor the process carefully. Should the compressor start to Knock, rotate the INLET valve clockwise until the knocking stops. This can also be accomplished by adjusting the Manifold Gauge valves. Exercise care to ensure that the compressor is not damaged in this way as it will void the warranty. If the Tank Full shutoff is not in use, it is necessary to use a Refrigerant Scale to ensure that the tank is not filled to more than 80% of its capacity by weight. When operating in the NORMAL RECOVERY or PUSH-PULL mode without the tank shutoff, it is possible to overfill the tank. Check the tank weight before transporting if you are not sure. OVERFILLED TANKS CAN RUPTURE EXPLOSIVELY! 3.2 Normal Recovery Operation 1 Connect all cables and hoses as described in section 3.1 and as shown in Figure 3-1 below. Ensure that they are tight and routed in such a way that they will not interfere with the operation. Figure 3-1 Setup Procedure For Normal Refrigerant Recovery 6

2 Make sure that the hose from the Vortex AC to the Recovery Tank is attached to the LIQUID PORT. Open the tank s LIQUID PORT valve, keeping the VAPOR port closed. 3 CLOSE the INLET valve (V1). 4 OPEN the DISCHARGE valve (V3) to its fully open position. 5 SET the PURGE/RECOVERY valve (V2) to the RECOVERY position. 6 Open the Manifold Gauge LIQUID valve slowly and verify that no leaks are present. Extracting as much liquid as possible will speed up the recovery process. 7 Switch ON the Vortex AC. 8 MONITOR the inlet pressure (LP, Low Pressure Gauge) and SLOWLY OPEN the Vortex AC s INLET valve (V1). THROTTLE the INLET valve or the Manifold Gauge s Liquid and Vapor valves if too much liquid is entering the machine. If the Tank Full shutoff is not in use, it is necessary to use a Refrigerant Scale to ensure that the tank is not filled to more than 80% of its capacity by weight. When operating in the NORMAL RECOVERY or PUSH-PULL mode without the tank shutoff, it is possible to overfill the tank. Check the tank weight before transporting if you are not sure. OVERFILLED TANKS CAN RUPTURE EXPLOSIVELY! 9 When the liquid has been transferred, OPEN the INLET valve (V1) fully to transfer the remaining VAPOR. Ensure that the Manifold Gauge valves (liquid and vapor) are also fully opened. 10 Continue to operate until the required VACUUM has been pulled on the system, as indicated by the LP gauge. Switch OFF the Vortex AC, CLOSE the INLET (V1), and wait for 5 minutes. If the Pressure in the system, as noted on the Manifold Gauge, rises above 0 PSIG, refrigerant is still present. If this is the case, REOPEN the INLET (V1), RESTART the Vortex AC, and run until the required VACUUM is reached again. Repeat this process until all the refrigerant is removed resulting in a final reading, after the 5 minute period, of 0 PSIG or less. 11 IMMEDIATELY PURGE the Vortex AC per the procedure as described in section 3.3 of this Manual. 7

3.3 PURGING the Vortex AC 1 Rotate the PURGE/RECOVER valve (V2) to the PURGE position. Rotate valve V3 to OPEN. See Figure 3-2. 2 Switch the POWER ON and rotate the INLET valve (V1) slowly to the PURGE. Prevent flooding the compressor with liquid, do not rotate the V1 valve quickly. 3 Observe the LP Gauge and continue to run the unit until a VACUUM of at least 20 In/Hg is achieved. Switch the POWER OFF and immediately CLOSE the Recovery Tank s valve. The INLET valve (V1) should be returned to the CLOSE position. Finally close V3. 4 IMPORTANT RETURN V2 TO RECOVERY POSITION THE HOSE AND THE DISCHARGE PORT WILL CONTAIN A SMALL AMOUNT OF REFRIGERANT UNDER PRESSURE. EXERCISE CARE WHEN REMOVING THIS HOSE AND OPENING THE VALVE V3. Figure 3-2 Setup Procedure for Purging 3.4 Push-Pull Operation The PUSH PULL method is used to move a large amount of liquid refrigerant from the system being serviced to the recovery tank without passing it through the compressor. This method is only useful when more than 15 pounds of liquid is known to be in the system and it can be easily isolated. DO NOT ATTEMPT the PUSH PULL process unless you are sure of the situation. Connect the refrigerant hoses as shown in Figure 3-3. The addition of a SIGHT GLASS in the line from the system being serviced to the recovery tank is an important aid to determine when the liquid has been transferred and vapor remains. 8

This process uses the PULL from the exhausted recovery tank and the Discharge PUSH from the Vortex AC to move the liquid refrigerant. Rates in excess of 15 pounds per minute can be achieved by this procedure. The SCALE is required in this process to ensure that the tank is not overfilled. The tank shutoff switch, if used, would stop the compressor but could not guarantee that additional refrigerant flow would cease because of the dynamics of the system, thus possibly overfilling the tank. Figure 3-3 Setup Procedure for Push-Pull Method 3.5 Cooling The Recovery Tank The Vortex AC can be used to PRE-cool (or SUB-cool) the recovery tank if the head pressure is too high to complete the recovery process. This can occur when working with certain refrigerants with a high vapor pressure when the ambient temperature is high. If the recovery process stalls out because of high head pressure, stop the Vortex AC, shut off the hose valves and reconfigure the setup as shown in Figure 3-4. This can also be done before starting the recovery process, but it may have marginal long term effect. NOTE: This will only work if there is at least 5 pounds of liquid in the recovery tank to develop the necessary pressure differential required. 9

Figure 3-4 Setup Procedure for Sub-Cooling Method VAPOR Optional Connection To System POWER ON the Vortex AC and ROTATE the DISCHARGE Valve (V3) to achieve a pressure differential of at least 100 PSIG between the LP Gauge and the HP Gauge. KEEP THE HP BELOW 550 PSIG on the HP Gauge to ensure that the HP Cutoff Switch will not actuate. After several minutes of running, the tank will be cold. POWER OFF the Vortex AC and reconfigure the setup for NORMAL RECOVERY. Repeat as needed. 3.6 Special Operating Notes During normal operation, when the High Pressure switch activates the machine will restart automatically when the head pressure drops below approximately 425 PSI. When the Tank Over Fill Protection Device (OFPD) is installed, the yellow Tank Full signal light will be illuminated when the OFPD cable is not connected or when the tank is full. 10

4.0 Maintenance Vortex AC Operating Manual Your Vortex AC will provide many seasons of reliable service providing it is properly maintained. The actual maintenance requirements are minimal but important. Keep the unit clean by wiping it down with a damp cloth to remove dirt, oils, etc., prior to storage for the day. Standard household detergent or isopropyl alcohol may be used if the unit is particularly dirty in all cases, exercise care to prevent liquids from entering the unit. Gasoline and other solvents are to be avoided as they can damage the Vortex AC s plastic enclosure and they are hazardous. Ensure that the Inlet and Discharge ports are protected in transit and storage keep the inner diameter and the outer threads clear and clean. For best results, keep a FILTER permanently connected to the INLET port and change it regularly. When performance falls off it is likely that the compressor seals require replacing. This is normal with use and may occur after a year or two, or more often depending upon the conditions that are prevalent during the recovery operations. Contact your Wholesaler for assistance in selecting the proper maintenance kit. 11

5.0 Troubleshooting Vortex AC Operating Manual PROBLEM CAUSE ACTION Unit will not start Compressor does not start Unit will not start Optional Over Fill Protection Device is installed. Compressor starts but cuts out within a few minutes pressure indication on HP gauge is high 1. Power Cord not attached 2. No voltage at receptacle 3. Circuit breaker has opened 4. Discharge pressure too high, HP Switch has opened 5. Electronics failure in Motor 1. Tank Full cable not connected to tank 2. Float switch in Tank is open 3. Tank is full and float switch has opened 1. V2 is in Purge position and HP switch activates 2. V3 not open and HP switch activates 3. Recovery tank valve not open 4. Blocked discharge hose 5. Air in system/tank 1. Attach Power Cord 2. Verify voltage at Job Site 3. Identify cause of breaker activation, rectify and reset 4. Reduce pressure and rotate V2 to Purge and back to Recovery 5. Factory service required 1. Connect cable 2. Check tank switch with multimeter; change tanks or use scale 3. Change tanks 1. Rotate V2 to Recovery 2. Rotate V3 to open position 3. Open tank valve 4. Check & clear blockage 5. Bleed air from system/tank 12

PROBLEM CAUSE ACTION Compressor stops intermittently Unit overheats Recovery process too slow 1. Vapor pressure of refrigerant in tank is close to HP trip point 2. Thermal overload switch in compressor is activating Excessive head pressure due to: 1. High ambient temperature 2. Restricted discharge hose 3. Air in recovery tank 1. Head pressure too high 2. System refrigerant iced up 3. Compressor seals are worn 1. Reduce tank temperature 2. Reduce amount of liquid being pumped and let machine cool down before proceeding 1. Reduce tank temperature 2. Check & clear restriction 3. Bleed air from tank 1. Reduce tank temperature or change tanks 2. Throttle gauge manifold valves and V3 to reduce pressure differential between LP and HP gauges 2. Interrupt process to allow ice to dissipate 3. Rebuild compressor with service kit check with wholesaler for assistance 6.0 Service 6.1 General The Vortex AC uses only UL or CSA Recognized electrical components or components which have been specially designed for this application. DO NOT CHANGE any of these components as the safety of the machine could be compromised. All service work must be performed at an INFICON approved facility in order to maintain the safety rating and the Warranty, if applicable. Technical assistance and service information can be obtained by calling the factory at 800-344-3304. 13

NOTE: Do not return a defective unit directly to the factory. Contact your Wholesaler or the factory for assistance. The following Parts and Accessories for your Vortex AC are available through the same dealer from whom you purchased the unit: Item Part # Compressor, 115 V(ac) 714-407-P1 Motor Start Relay 060-0055 Run Capacitor, 50μf, 240 V(ac) 043-0109 Start Capacitor, 161-193 μf, 125 V(ac) 043-0106 Circuit breaker, 110/220 V, 10 A 062-0079 Cord set, IEC plug, 110 V, 15 A 068-0391 On/Off Switch 065-0261 Socket power in, IEC male 051-1359 Manifold Assembly with extensions and fittings 708-403-P1 Gauge, High Pressure, 1/8 NPT M Conns. 708-402-P1 Gauge, Low Pressure, 1/8 NPT M Conns. 708-401-P1 Pressure Switch, high pressure cutout 032-0055 Condenser Assembly with tubes 708-204-G1 Case Housing - right side 714-306-P1 Case Housing - left side 714-307-P1 Strap, shoulder 708-404-P1 Cap and strap, plastic with lead 070-1107 Handle, SS tube 708-311-P1 Overfill Protection Device Cable - Yellow QC20032 Overfill Protection Device Complete (with LED cover plate) 708-203-G1 Only technically qualified personnel who are familiar with basic electronics and refrigeration systems should install the Over Fill Protection Device. Disassembly of the unit to rebuild the compressor or to provide other repair work should be referred to an approved service center as indicated above. 14

6.2 Electrical Schematic Vortex AC Operating Manual AC Power Receptacle 120 120 VAC VAC Input AC GND Return BLACK Power S1 1 2 Switch BLACK Circuit CB1 1 2 10A Breaker Breaker BLACK WHITE RED MOTOR START CAPACITOR RED BLACK HI Pressure SW SW2 BLACK C1 161-193uF 125VAC MOTOR RUN CAPACITOR RED 1 2 3 LS1 TI Motor Klixon Start Relay 2 4 3 4CR-1-738 C2 50uF 240VAC M1 AC Compressor TI Klixon 25PS06-0018 Motor J2 VLP-03V JST 3 2 1 P1 VLR-03V JST 4 5 1 2 3 J1 VLR-03V Qualtek 701W-X2/04 1 2 3 ORANGE WHITE AC Compressor BLACK OFPD Jumper Figure 6-1 Electrical Schematic Diagram 15

7.0 EPA Requirements Under Section 608 of the Clean Air Act (40 CFR Part 82), the Environmental Protection Agency (EPA) has established regulations that cover all aspects of the refrigerant recovery process. These regulations have established service practices that maximize the recycling of ozone-depleting compounds during the servicing and disposal of air-conditioning and refrigeration equipment. Certification requirements for recovery equipment and technicians have also been established. The INFICON Vortex AC has been EPA Certified for use by Underwriters Laboratories Inc. The EPA has also established Evacuation Requirements for equipment which is being opened for service, to ensure that any release of CFCs or HCFCs to the atmosphere is minimized. Technicians repairing small appliances such as household refrigerators, window air conditioners and water coolers, must recover 80% of the refrigerant when the compressor in the appliance is not operating. Technicians repairing small appliances must recover 90% of the refrigerant when the compressor in the appliance is operating. NOTE: These requirements may also be met by evacuating the small appliance with the recovery machine to four inches of mercury vacuum. Other requirements are covered in the following Table 7-1. 16

Table 7-1 EPA Requirements Vortex AC Operating Manual TYPE OF APPLIANCE REQUIRED INCHES OF HG VACUUM HCFC-22 appliance normally containing less than 200 pounds of refrigerant 0 HCFC-22 appliance normally containing 200 pounds or more or refrigerant 10 Other high pressure appliance normally containing less than 200 pounds of refrigerant 10 Other high pressure appliance normally containing 200 pounds or more of refrigerant 15 Very high pressure appliance (CFC-13, -503) 0 Low Pressure appliance (CFC-11, HCFC-123) 1 The EPA also requires that service technicians certify to the appropriate EPA Regional Office that they have acquired recovery equipment and that they are complying with the applicable laws established by the Clean Air Act. Forms for this are available from the Regional Office of the EPA. Any questions about the EPA requirements can be answered by contacting the OZONE PROTECTION HOTLINE TOLL FREE @ 800-296-1996. 17

TWO TECHNOLOGY PLACE EAST SYRACUSE, NY 13057-9714 USA Phone: +1.800.344.3304 Fax: +1.315.437-3803 Email: reachus@inficon.com www.inficon.com 074-402-P1B