OPAL TM Detector range



Similar documents
MINERVA MX MX Virtual Multi-Sensor Detectors

Analogue addressable devices

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Notifier by Honeywell: Cost Effective Fire Detection and Alarm

Repeaters and Mimics Data Sheet

Fire detection equipment

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Triple Waveband Infra-Red Flame Detection

Fire Detection Product Range

SMART SENSOR COLLECTION

FSD Circular Letter No. 7/95 Automatic Fire Detection System - Design and Maintenance Considerations

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Notifier by Honeywell: Voice Alarm Solutions

Advanced Intelligent Modules. Overview. Description

How To Make A Commercial Detector

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Fire. The Fire Installers Mate. A guide to fire alarm systems design

HART HSSD High Sensitivity Smoke Detection

Fire Detection Systems

Smoke Detector PSD 2 & 4 Wire Units

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

FAAST. Fire Alarm Aspiration Sensing Technology

Consultant s Guide for Fire Detection & Alarm Systems for Buildings

Fire Alarm system Installation Guide

Smoke detector 500 Series The art of invisible fire detection

Principles of ASA firedetection

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

CB Zone Conventional Control Panel

Hygro-Thermometer + InfraRed Thermometer Model RH101

Product Overview Brochure. Flexibility to design a fire system that best suits you

E-PDD Duct Smoke Detector Installation Sheet

FIRE DETECTION AND ALARM SYSTEMS

Sea Eagle FCCT. Naval Electro-Optical Fire Control System

PROTEC CIRRUS HYBRID ASPIRATING SMOKE DETECTION SYSTEMS

DUCT SMOKE DETECTOR D4120

DCP Fan Controller. Version 01/2009. The engineer s choice

Faraday Intelligent Fire Detection Systems

Fire Detection System. for Wind Power Plant

INTELLIGENT MONITORING FOR SAFER BUSINESS

Iophic Smoke Detection Technology. An Introduction. Universal Security Instruments. Over 40 Years of Residential & Commercial Safety Innovations

Emergency Voice Communication Systems

BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Conventional Fire Detection and Extinguishant Control System Specification

EMF/EMR. Holder/Release Devices with Integral Door Closers

Digital input modules

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

AlarmSense 2-wire detection and alarm system. Product Guide

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

WD-AMX Water Detection Controllers

conventional system operation

2 & 5-Wire Overfill Sensors

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

THE OPTIMUM IN FIRE DETECTION

SERIES 65 ENGINEERING PRODUCT GUIDE

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Smart Thermostat page 1

VEGA Analogue Addressable Control Panels

Life safety solutions. protecting every single asset

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

False Alarm/Unwanted Fire Signals Reduction Guidance

BS5839 Part 1:2002 Overview

A Tradition of Fire Detection Innovation

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Precision Leaded Resistors

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

ALARMLINE ANALOGUE Linear Heat Detection System

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

How to Select a Flame Detector

ADVANCED SCOOTER CONTROL SYSTEMS PG DRIVES TECHNOLOGY

EVALUATION OF THE PERFORMANCE OF FIRE DETECTION SYSTEM IN AN INSTITUTIONAL BUILDING

Bringing good things ahead

QCS Section 23 Part 2 Fire Alarm and Detection Systems Page 1 2. FIRE ALARM DETECTION SYSTEMS...2

New XUY roller sensors

NetScanner System. Toronto: , Montreal: , Toll Free: ,

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Fire alarm system EBL512 G3

Standard the the Raising

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Overview of Fire Alarm Systems and Maintenance

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

TLP281,TLP281-4 TLP281,TLP281-4 PROGRAMMABLE CONTROLLERS AC/DC-INPUT MODULE PC CARD MODEM(PCMCIA) Pin Configuration (top view)

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

Technical Manual MDT Rain sensor

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

welcome to our world fire alarm systems - series 600

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Dual Laser InfraRed (IR) Thermometer with Color Alert

Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors

Product Catalogue. catalogue. Fire and Gas Detection Systems. Product catalogue. Honeywell Life Safety Benelux. nl

QCS 2014 Section 23: Fire Fighting and Fire Alarm Systems Page 1 Part 01: General

Always on the Lookout Perfect Protection against Burglary

Transcription:

OPAL TM Detector range Data Sheet The revolutionary OPAL range delivers a totally new detector platform incorporating an advanced digital protocol. The advanced protocol delivers more devices on the loop and gives greater control, configurability and device management whilst enabling the overall system to be optimised to the location and use of the building with far greater flexibility than ever before. Features Available with or without short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector and ease installation and wiring Technology Leadership Opal incorporates major hardware and software technology driven developments. A completely new optical chamber design is proven in extensive testing to be more efficient, less liable to false alarm due to dust and insects and less susceptible to fault in high air velocities or back pressure. Extensive hydrodynamic modelling has confirmed the greater efficiency of the new chamber and housing shape combination. Largescale integration of the all-new electronics, through the fully automated surface mount PCB assembly, coupled with inline testing through the manufacturing process, laser PCB cutting along with a completely new compound of plastic offers improved quality and reliability. All OPAL detectors are environmentally friendly and meet the WEEE and RoHS legislative requirements, minimising end of life disposal costs, and are mechanically and electrically backwards compatible with existing devices. Product Range The family consists of six detection devices: three heat detectors (58 and 78 fixed temperature, and rate of rise), an optical smoke, a photo-thermal multi-sensor and our award winning SMART 3. All six devices come with or without electrical short circuit isolation and the new Advanced Protocol. In addition to the new family of devices, a new installation base that makes the installation process far easier and quicker, replaces the previous versions. This document is not intended to be used for installation purposes. Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. For more information, contact: NOTIFIER. Charles Avenue, Burgess Hill, West Sussex, RH15 9UF. United Kingdom Phone: +44 (0) 1444 230 300 Fax: +44 (0) 1444 230 888 Page 1 of 6-990-137_0110 ISO9001 Design, Manufacture and Supply to Quality Management Systems Certified to ISO9001:1994 www.notifierfiresystems.co.uk

Opal TM Photoelectric Smoke Detectors - NFX-OPT & NFXI-OPT The Opal photoelectric smoke detector has a completely new detection chamber design, the result of many years of research and development. This delivers improved responsiveness, reduced sensitivity changes caused by settling dust and reduced false alarms resulting from ingress of insect and other debris. The plug-in unit uses sophisticated processing circuitry that incorporates smoothing fi lters to help eliminate transient environmental noise conditions that can be the cause of unwanted alarms. The devices are managed by embedded software running complex algorithms that further improve resilience to false alarms and improve detection speed. The Opal NFX-OPT has two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red, amber and green status indications available. Opal NFX-OPT (without isolator) Opal NFXI-OPT (with isolator) 52mm installed in B501AP base 97g (inc base) Opal NFX-OPT 300μA @ 24Vdc (LED blink enabled, once every 5 seconds) using the B501AP: typ 20mohm (max 30 mohm) Only found in Opal NFXI-OPT : typ 80mohm @ 24V Page 2 of 6-990-137_0110

Opal TM Photoelectric Smoke / Thermal Multi-Criteria Fire Detectors - NFX-SMT2 & NFXI-SMT2 The Opal multi-criteria, multi-sensor, photo, thermal detector uses thermal assistance to the core photoelectric smoke detector to give enhanced false alarm immunity and faster response to a wide range of incipient fires. The plug-in unit combines two separate sensing elements that are managed by embedded software to act as a single unit. The Opal NFX-SMT2 conforms to EN54-7, a 58 C fixed temperature and rate of rise thermal assistance conforming to EN54-5. The thermal detection function combines thermistor technology with a software corrected linear temperature response. In areas where the normal daytime activities may potentially create unwanted alarms, the detector can be programmed to operate in a heat only mode, automatically reverting to full photo-thermal operation during unoccupied periods. The sensing elements of the Opal NFX-SMT2 are panel controllable so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detector has two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red, amber and green status indications available. Opal NFX-SMT2 (without isolator) Opal NFXI-SMT2 (with isolator) 61mm installed in B501AP base 99g (inc base) Opal NFX-SMT2 300μA @ 24Vdc (LED blink enabled, once every 5s) using the B501AP: typ 20mohm (max 30 mohm) Only found in Opal NFXI-SMT2 : typ 80mohm @ 24V Sensitivity Settings Alarm level 1 Alarm level 2 Alarm level 3 Alarm level 4 Alarm level 5 Alarm level 6 1%/ft smoke 2%/ft smoke 3%/ft smoke 3%/ft smoke 3%/ft smoke Class A1R Page 3 of 6-990-137_0110

OPAL TM SMART 3 Photo, Thermal, & Infra Red Multi-Criteria Detectors - NFX-SMT3 & NFXI-SMT3 The Opal multi-criteria, multi-sensor, photo, thermal and infra red (SMART 3 ) detector is the environmentally friendly alternative to the ionisation detector, a technology that is now over sixty years old. The SMART 3 offers comparable speed of response to the ionisation technology for a fast flaming fire and is less susceptible to false alarms. It can be deployed with confidence in locations where the main risk is from fast-developing flaming fires. SMART 3 moves the goal posts in the fight against false alarms in the core detector space by delivering enhanced false alarm immunity. In addition to being an effective alternative to ionisation units, SMART 3 offers better performance over the alternative technologies of dual angle or dual wavelength optical detectors and photo-thermal detectors. The integration of continual monitoring for all three major elements of a fire enables the Opal NFX-SMT3 to respond far more quickly to an actual fire and has the highest immunity to nuisances. Based upon the sensor signals, the program dynamically changes sensor thresholds, sensor gain, time delays, combination, sampling rates, averaging rates and, if any sensor fails, changing sensitivity of the remaining sensors as well as indicating a fault condition. The sensing elements of the Opal NFX-SMT3 are panel controllable so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detector has two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red, amber and green status indications available. Opal NFX-SMT3 (without isolator) Opal NFXI-SMT3 (with isolator) 63mm installed in B501AP base 102g (inc base) - Opal NFX-SMT3 300μA @ 24Vdc (LED blink enabled, once every 5s) using the B501AP: typ 20 mohm (max 30 mohm) Note: The panel threshold should be chosen according to the specifi c environment. The following would be Notifi er s recommendations: Ultra-clean applications use Level 1 for pre alarm or alarm. Clean Applications use Level 1 for pre alarm and Levels 2 & 3 for alarm. Moderate environments use Level 1,2 or 3 for pre alarm and Level 4 for alarm. Harsh environments use Level 2 or 3 for pre alarm and Levels 5-6 for alarm Page 4 of 6-990-137_0110 - Only found in Opal NFXI-SMT3 : typ 80mohm @ 24V Sensitivity Settings Alarm level 1 Low false alarm resistance, high photoelectric only sensitivity. 1%/ft smoke Alarm level 2 Medium false alarm resistance, medium photoelectric only sensitivity. 2%/ft smoke Alarm level 3 Standard false alarm resistance, low photoelectric only sensitivity. 3%/ft smoke Alarm level 4 High false alarm resistance, low photoelectric only sensitivity. 3%/ft smoke Alarm level 5 Very high false alarm resistance, low photoelectric only sensitivity. 3%/ft smoke Alarm level 6 Class A1R

OPAL TM Thermal Sensors - NFX-TDIFF, NFX-TFIX58, NFX-TFIX78 The Opal NFX-TFIX58 & NFX-TFIX78 are fixed temperature analogue addressable sensors employing low mass thermistors and microprocessor technology for fast response and linear temperature sensing. Their linear response allows these sensors to be used to signal temperatures over the range of 58 C (Class A1S) to 78 C (Class BS). The Opal NFX-TDIFF uses the same thermistor and microprocessor technology to provide an alarm when the rate of rise in temperature exceeds 10 C/minute (typical) or if the temperature exceeds a threshold of 58 C (Response Class A1R). With the implementation of the advanced protocol, any model can be software configured to be either a fixed 58 C, a fixed 78 C unit or a 58 C with rate of rise device. For backwards compatibility and approval continuity, three separate versions continue to be available as separate part numbers. The sensing elements of all three heat sensors are panel controllable through the Advanced Protocol so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detectors have two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red, amber and green status indications available. Opal NFX-TDIFF, NFX-TFIX58, NFX-TFIX78 (without isolator) Opal NFXI-TDIFF, NFXI-TFIX58, NFXI-TFIX78 (with isolator) 61mm installed in B501AP base 88g (excluding base) Opal NFX-TDIFF, NFX-TFIX58, NFX-TFIX78 300μA @ 24Vdc (LED blink enabled, once every 5s) using the B501AP: typ 20 mohm (max 30 mohm) Only found in Opal NFXI-TDIFF, NFXI-TFIX58, NFXI-TFIX78 : typ 80mohm @ 24V Heat Detection Performance NFX/NFXI-TDIFF Class A1R: 58 C fixed temperature and rate of rise NFX/NFXI-TFIX58 Class A1S: 58 C fixed temperature NFX/NFXI-TFIX78 Class BS: 78 C fixed temperature Page 5 of 6-990-137_0110

Product Range at a Glance Isolator Colour Part Number NFX-OPT OPAL Optical smoke detector Ivory NFX-OPT-IV NFXI-OPT NFX-SMT2 OPAL Optical smoke & heat detector Ivory NFX-SMT2-IV NFXI-SMT2 NFX-SMT3 OPAL Optical smoke & heat detector with infra-red fl ame sensing Ivory NFX-SMT3-IV NFXI-SMT3 NFX-TFIX58 OPAL Heat detector, fi xed 58ºC Ivory NFX-TFIX58-IV NFXI-TFIX58 NFX-TDIFF OPAL Heat detector (A1R), rate of rise + fi xed 58ºC Ivory NFX-TDIFF-IV NFXI-TDIFF NFX-TFIX78 OPAL Heat detector, fi xed 78ºC Ivory NFX-TFIX78-IV NFXI-TFIX78 Analogue sensor base with SEMS screw connections for isolated and non-isolated detectors and address identifi cation label n/a B501AP n/a Ivory B501AP-IV Page 6 of 6-990-137_0110 Charles Avenue Burgess Hill W. Sussex RH15 9UF T: +44 (0) 116 246 2255 F: +44 (0) 116 246 2210 E: sales@notifierfiresystems.co.uk www.notifierfiresystems.co.uk