HP ProLiant DL580 Gen8 and HP LE PCIe Workload WHITE PAPER Accelerator 90TB Microsoft SQL Server Data Warehouse Fast Track Reference Architecture

Similar documents
Maximum performance, minimal risk for data warehousing

Fusion iomemory iodrive PCIe Application Accelerator Performance Testing

HP high availability solutions for Microsoft SQL Server Fast Track Data Warehouse using SQL Server 2012 failover clustering

HP ProLiant Gen8 vs Gen9 Server Blades on Data Warehouse Workloads

Lenovo Database Configuration for Microsoft SQL Server TB

HP recommended configurations for Microsoft Exchange Server 2013 and HP ProLiant Gen8 with direct attached storage (DAS)

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

HP 85 TB reference architectures for Microsoft SQL Server 2012 Fast Track Data Warehouse: HP ProLiant DL980 G7 and P2000 G3 MSA Storage

Improve Business Productivity and User Experience with a SanDisk Powered SQL Server 2014 In-Memory OLTP Database

HP ProLiant BL660c Gen9 and Microsoft SQL Server 2014 technical brief

Solution Brief: Microsoft SQL Server 2014 Data Warehouse Fast Track on System x3550 M5 with Micron M500DC Enterprise Value SATA SSDs

SQL Server Business Intelligence on HP ProLiant DL785 Server

Lenovo Database Configuration for Microsoft SQL Server TB

Best Practices for Optimizing SQL Server Database Performance with the LSI WarpDrive Acceleration Card

Accelerating Enterprise Applications and Reducing TCO with SanDisk ZetaScale Software

The MAX5 Advantage: Clients Benefit running Microsoft SQL Server Data Warehouse (Workloads) on IBM BladeCenter HX5 with IBM MAX5.

Express5800 Scalable Enterprise Server Reference Architecture. For NEC PCIe SSD Appliance for Microsoft SQL Server

HP PCIe IO Accelerator For Proliant Rackmount Servers And BladeSystems

Data Center Storage Solutions

ACCELERATE SQL SERVER 2014 WITH BUFFER POOL EXTENSION ON LSI NYTRO WARPDRIVE

HP ProLiant DL380p Gen mailbox 2GB mailbox resiliency Exchange 2010 storage solution

Data Center Solutions

HP recommended configuration for Microsoft Exchange Server 2010: ProLiant DL370 G6 supporting GB mailboxes

Optimizing SQL Server Storage Performance with the PowerEdge R720

SUN ORACLE EXADATA STORAGE SERVER

Accelerate SQL Server 2014 AlwaysOn Availability Groups with Seagate. Nytro Flash Accelerator Cards

How To Store Data On An Ocora Nosql Database On A Flash Memory Device On A Microsoft Flash Memory 2 (Iomemory)

PSAM, NEC PCIe SSD Appliance for Microsoft SQL Server (Reference Architecture) September 11 th, 2014 NEC Corporation

WITH A FUSION POWERED SQL SERVER 2014 IN-MEMORY OLTP DATABASE

Dell Microsoft Business Intelligence and Data Warehousing Reference Configuration Performance Results Phase III

SUN ORACLE DATABASE MACHINE

DATA WAREHOUSE FAST TRACK FOR MICROSOFT SQL SERVER 2014

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

All-Flash Storage Solution for SAP HANA:

Intel RAID SSD Cache Controller RCS25ZB040

How To Write An Article On An Hp Appsystem For Spera Hana

Microsoft SQL Server Acceleration with SanDisk

Amadeus SAS Specialists Prove Fusion iomemory a Superior Analysis Accelerator

HP reference configuration for entry-level SAS Grid Manager solutions

HP SN1000E 16 Gb Fibre Channel HBA Evaluation

MaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1

Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array

Delivering Accelerated SQL Server Performance with OCZ s ZD-XL SQL Accelerator

QuickSpecs. What's New Support for two InfiniBand 4X QDR 36P Managed Switches

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820

Microsoft SQL Server 2014 Fast Track

SanDisk Lab Validation: VMware vsphere Swap-to-Host Cache on SanDisk SSDs

EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server

Virtuoso and Database Scalability

Oracle Database Reliability, Performance and scalability on Intel Xeon platforms Mitch Shults, Intel Corporation October 2011

Cisco-EMC Microsoft SQL Server Fast Track Warehouse 3.0 Enterprise Reference Configurations. Data Sheet

Data Center Solutions

An Oracle White Paper May Exadata Smart Flash Cache and the Oracle Exadata Database Machine

Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays

Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering

James Serra Sr BI Architect

Improving Microsoft Exchange Performance Using SanDisk Solid State Drives (SSDs)

New to servers. Are you new to servers? Consider these HP ProLiant Essentials servers. Family guide HP ProLiant rack and tower servers

Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance

Using Iometer to Show Acceleration Benefits for VMware vsphere 5.5 with FlashSoft Software 3.7

Oracle Acceleration with the SanDisk ION Accelerator Solution

Microsoft SharePoint Server 2010

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

Cisco UCS and Fusion- io take Big Data workloads to extreme performance in a small footprint: A case study with Oracle NoSQL database

Database Server Configuration Best Practices for Aras Innovator 10

How System Settings Impact PCIe SSD Performance

Dell s SAP HANA Appliance

Business white paper. HP Process Automation. Version 7.0. Server performance

Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage

HP Client Virtualization SMB Reference Architecture for Windows Server 2012

HP D3600 Disk Enclosure 4,000 Mailbox Resiliency Exchange 2013 Storage Solution

How To Compare Two Servers For A Test On A Poweredge R710 And Poweredge G5P (Poweredge) (Power Edge) (Dell) Poweredge Poweredge And Powerpowerpoweredge (Powerpower) G5I (

Configuring and using DDR3 memory with HP ProLiant Gen8 Servers

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

All Silicon Data Warehouse: Violin Memory Fast Track Data Warehouse Reference Architecture. Installation and Configuration Guide

Accelerating Microsoft Exchange Servers with I/O Caching

Brainlab Node TM Technical Specifications

2009 Oracle Corporation 1

Configuring the HP DL380 Gen9 24-SFF CTO Server as an HP Vertica Node. HP Vertica Analytic Database

Copyright 2013, Oracle and/or its affiliates. All rights reserved.

SQL Server 2014 Optimization with Intel SSDs

Vormetric and SanDisk : Encryption-at-Rest for Active Data Sets

The Hardware Dilemma. Stephanie Best, SGI Director Big Data Marketing Ray Morcos, SGI Big Data Engineering

Boost Database Performance with the Cisco UCS Storage Accelerator

Dell Microsoft SQL Server 2008 Fast Track Data Warehouse Performance Characterization

HP Smart Array Controllers and basic RAID performance factors

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

SUN ORACLE DATABASE MACHINE

HP RA for SAS Visual Analytics on HP ProLiant BL460c Gen8 Servers running Linux

Virtualizing Microsoft SQL Server on Dell XC Series Web-scale Converged Appliances Powered by Nutanix Software. Dell XC Series Tech Note

Capacity Management for Oracle Database Machine Exadata v2

Scaling in a Hypervisor Environment

High Performance SQL Server with Storage Center 6.4 All Flash Array

Cisco SmartPlay Select. Cisco Global Data Center Promotional Program

QuickSpecs. HPE Solid State Drives (SSD) Overview. HPE Solid State Drives (SSD) What's New

Transcription:

WHITE PAPER HP ProLiant DL580 Gen8 and HP LE PCIe Workload WHITE PAPER Accelerator 90TB Microsoft SQL Server Data Warehouse Fast Track Reference Architecture Based on Microsoft SQL Server 2014 Data Warehouse Fast Track (DWFT) Reference Architecture Western Digital Technologies, Inc. 951 SanDisk Drive, Milpitas, CA 95035 www.sandisk.com

Table of Contents Executive Summary... 3 About the HP ProLiant DL580 Gen8... 3 Key Benefits and Features... 3 New Data Warehouse Features in Microsoft SQL Server 2014... 4 About the Data Warehouse Fast Track (DWFT) Reference Architecture... 4 Storage Configuration... 4 Storage Layout... 4 Power Override... 5 Database Configuration... 5 TempDB Configuration... 5 SQL Server Settings... 5 Resource Governor... 5 Max Degree of Parallelism (MDOP)... 6 Memory Configuration... 6 Trace Flags... 7 Windows Server 2012 R2 Configuration... 7 Power Settings... 7 BIOS Configuration... 7 SQL Server Data Warehouse Fast Track Reference Architecture Results... 8 Summary... 9 Bill of Materials... 10 2

Executive Summary The Microsoft SQL Server Data Warehouse Fast Track (DWFT) reference architecture is designed to eliminate the complexity of properly sizing hardware, which helps reduce unnecessary scale- out of storage and servers. The sizingtechniques used in SQL Server DWFT will properly size servers, based on I/O and CPU consumption. This consumption- based approach ensures your data warehouse can fully take advantage of your hardware investment. This document is for individuals (BI Architects, DBAs, Report Developers, and IT Directors) involved in decision making who are looking for guidance when designing enterprise, business - intelligence applications. About the HP ProLiant DL580 Gen8 The HP ProLiant DL580 Gen8 Server is an enterprise- grade, four- socket (4S) x86 server offering breakthrough performance, rock- solid reliability, and compelling consolidation and manageability efficiencies. It is the ideal choice for mission- critical enterprise, business intelligence, and database applications. Featuring Intel Xeon E7-4800/8800 v2 processors, the HP ProLiant DL580 Gen8 offers 2.3X performance with enhanced processor performance, more memory slots (96 DIMMs), greater I/O bandwidth (9 PCIe Gen3.0 slots), and increased storage performance (12 Gb/s SAS). In addition, HP ProLiant DL580 Gen8 has security and data protection features for system resiliency that your business can depend on. Unique features such as HP Advanced Error Recovery and HP Memory Quarantine increase memory and processor reliability by over 30 percent. With intelligent manageability provided by embedded HP Integrated Lights- Out (ilo 4) capabilities, integrated management through HP OneView, and an array of customer- inspired features, your infrastructure management becomes faster and less expensive. Key Benefits and Features 1 Breakthrough 4S performance and scalability for blazing- fast results on your most demanding applications Up to 2.3X system performance and 50 percent more cores with Intel Xeon E7-4800/8800 v2 processors to speed up your mission- critical enterprise, business intelligence, and database applications 1.5X memory slots (96 DIMMs) for large- scale, in- memory computing and virtualization 2.7X I/O bandwidth with 9 PCIe Gen3 I/O slots, including 5 x 16 FL/FH slots for greater PCIe flash storage or co- processor cores Leading x86 availability and rock- solid reliability your business can depend on 30 percent fewer memory- and processor- based outages with HP Advanced Error Recovery and HP Memory Quarantine Industry- leading performance, uptime, and productivity integrated into a personalized, simplified support experience with HP Proactive Care Support Services Compelling efficiencies with intelligent manageability and scale- up consolidation 45 percent lower total cost of ownership with scale- up consolidation efficiencies, and options for fewer cores and high- frequency processors to drive down software licensing costs Faster, lower- cost infrastructure management and a single integrated view of your IT infrastructure with HP OneView 3X faster administrative updates with 93 percent less downtime and 69 percent less operator time using industry- leading maintenance tools with HP Smart Update Manager 1 Source: http://h20195.www2.hp.com/v2/getdocument.aspx?docname=4aa5-1019enw&doctype=data sheet&doclang=en_us&searchquery=&cc=us&lc=en 3

New Data Warehouse Features in SQL Server 2014 Microsoft added clustered column store indexes (CCI) in SQL Server 2014, which are designed to decrease query response times and deliver deeper levels of data compression. CCI eliminates the need to build summary tables, thus further reducing ETL run times. CCI is optimized for query performance. Our solution deliver 7x better query performance when using CCI. CCI accomplishes this by using a columnar format to compress the data by 10x or more, processing a set of rows in batches, and reading only the columns that are referenced in the query. CCI is updateable allowing concurrent insert both bulk import and trickle insert of new data while query workload is running. This reduces the data latency from the time data is born to when it is available for querying. About the DWFT Reference Architecture The SQL Server DWFT reference architecture provides a scalable framework centered on balancing I/O to achieve maximum performance from SMP- based servers. SQL Server DWFT eliminates the complexity of sizing servers with data warehouses by providing a set of data consumption rates that properly balances performance between the disk subsystem, CPU, and memory. This architecture is based on the HP ProLiant DL580 Gen8 and HP PCIe LE Workload Accelerator storage controller. This configurationis optimized for data warehouse (scan I/O) workloads and is rated by Microsoft for up to 90TB of compressed data. More information on SQL Server DWFT reference architecture can be found here: http://www.microsoft.com/en- us/server- cloud/data- warehouse- fast- track.aspx Storage Configuration Storage Layout Slot Number Device Capacity Mount Point Allocation Notes 1 HP PCIe LE WA PX600-5200 5.2TB IOM01 Data Files JBOD 2 HP PCIe LE WA PX600-5200 5.2TB IOM02 Data Files JBOD 3 HP PCIe LE WA PX600-5200 5.2TB IOM03 Data Files JBOD 4 HP PCIe LE WA PX600-5200 5.2TB IOM04 Data Files JBOD 5 HP PCIe LE WA PX600-5200 5.2TB IOM05 Data Files JBOD 6 HP PCIe LE WA PX600-5200 5.2TB IOM06 Data Files JBOD 8 HP PCIe LE WA PX600-1300 1.3TB IOMLOG Log and Staging Files Mirrored 9 HP PCIe LE WA PX600-1300 1.3TB IOMLOG Log and Staging Files Mirrored 4

Power Override Enabling the power override setting on the HP PCIe LE Workload Accelerator product line is required to achieve the performance results below. A server reboot is required for the setting to be active and persist. Example: Database Configuration File Group FT_Demo_Base FT_Demo_stage_part_ci1 FT_Demo_stage_part_ci2 FT_Demo_stage_part_ci3 FT_Demo_stage_part_ci4 FT_Demo_stage_part_ci5 FT_Demo_stage_part_ci6 FT_Demo_stage_part_ci7 FT_Demo_LOG # of Data Files 1 (transaction log on mount volume) TempDB Configuration One 20GB tempdb file was stored on each iomemory volume. In total, six tempdb data files were spread across six iomemory volumes. The tempdb transaction log file was stored on the volume designated from log and staging files. SQL Server Settings Resource Governor The Memory Grant % value was set to 12% of the memory allocated for row store runs and 25% for column store runs. The settings were changed in the Default resource pool. 5

Max Degree of Parallelism (MDOP) MDOP was set to 30 for row store and 120 for column store. This provided the best scan rates for the respective runs. Example: Memory Configuration SQL Server was allocated 90% of the server memory. The SQL Server service account was assigned the Lock Pages in Memory policy. 6

Trace Flags Trace flag - T1117 was used to increase performance. This flag forces all data files in a file group to grow at once, which reduces hot spots of data pages. This ensures that all databases with more than one data file will grow properly across all the data mounts, which in turn ensures maximum physical I/O performance. Trace flag E was omitted, as testing revealed a sharp increase in queue depth and latency which decreases scan performance. Therefore trace flag - E is not recommended with our flash technology. Windows Server 2012 R2 Configuration Power Settings The High Performance plan was chosen to reduce CPU throttling. BIOS Configuration Hyper- threading was enabled. System Profile was set to High Performance mode. Fan Offset was set to Increased Cooling. 7

SQL Server Data Warehouse Fast Track Reference Architecture Results DWFT Certification #2014-002 DWFT Rev. 5.4 HP ProLiant DL580 Gen8 with HP PCIe LE Workload Accelerator 90TB reference architecture for Microsoft SQL Server 2014 Data Warehouse Fast Track Report Date 9/3/2014 System Provider System Name Processor Type Memory Operating System HP ProLiant DL580 Gen8 Intel Xeon E7-4890 v2 2.8 GHz (4/60/120) SQL Server Edition 1536GB Storage Provider Windows Server 2012 R2 SQL Server 2014 Enterprise Edition Storage Information 6 x 5.2TB HP PCIe LE Workload Accelerator Flash devices for data and tempdb 2 x 500GB 7200RPM HDD for OS (RAID 1) 2 x 1.3TB HP PCIe LE Workload Accelerator Flash devices for log (RAID 1) Primary Metrics Rated User Data Capacity 1 (TB) Row Store Relative Throughput 2 Column Store Relative Throughput 3 Maximum User Data Capacity (TB) 90 314 419 108 Row Store Relative Throughput 2 Measured Throughput (Queries/Hr/TB) Measured Scan Rate Physical Measured Scan Rate Logical Measured I/O Throughput Measured CPU (Avg.) (%) 314 366 8,351 10,139 9,245 92 Relative Throughput 2 Measured Throughput (Queries/Hr/TB) Measured Scan Rate Physical Column Store Measured Scan Rate Logical Measured I/O Throughput Measured CPU (Avg.) (%) 419 2,721 3,392 N/A N/A 96 The reference configuration is a 2 socket system rated for 25TB using the FTDW V4 methodology 1 Assumes a data compression ratio of 5:1 2 Percent ratio of the throughput to the row store throughput of the reference configuration. 3 Percent ratio of the throughput to the column store throughput of the reference configuration. * Reported metrics are based on the qualification configuration, which specifies database size and SQL Server memory. 8

HP DL580 Gen8 and HP PCIe LE Workload Accelerator 90TB Data Warehouse Fast Track Reference Architecture Summary This solution went through hundreds of hours of testing and engineering to provide the most optimal and reliable configuration for the HP and SanDisk SQL Server Data Warehouse Fast Track Reference Architecture. The HP PCIe LE Workload Accelerator simplifies storage configuration by reducing the importance of sequential I/O, as evangelized in previous Data Warehouse Fast Track Reference Architectures. With 9000+ MB/s of database read throughput and a rated user data capacity 90TB, the HP ProLiant DL580 Gen8 with the HP PCIe LE Workload Accelerator delivers industry- leading, breathtaking performance with the ability to host extremely large data warehouses or a consolidation of data warehouses. Bill of Materials 90TB Certification SKU Description Quantity 728551- B21 HP ProLiant DL580 Gen8 Configure- to- order Server 1 728955- L21 HP ProLiant DL580 Gen8 Intel Xeon E7-4890v2 (2.8GHz/15- core/37.5mb/155w) FIO 4 732411- B21 HP ProLiant DL580 Gen8 12 DIMM Slots Memory Cartridge 8 708641- B21 HP 16GB (1x16GB) Dual Rank x4 PC3-14900R (DDR3-1866) Registered CAS- 13 Memory Kit 96 700752- B21 HP FlexFabric 10Gb 2- port 534FLR- SFP+ FIO Adapter 1 698537- B21 HP 4GB FIO Flash Backed Write Cache 1 775672- B21 HP 5.2TB FH/HL PCIe Light Endurance (LE) Workload Accelerator 6 775668- B21 HP 1.3TB HH/HL PCIe Light Endurance (LE) Workload Accelerator 2 652611- B21 HP 300GB 6G SAS 15K rpm SFF (2.5- inch) SC Enterprise 3yr Warranty Hard Drive 4 755996- B21 Microsoft Windows Server 2012 R2 Standard Edition FIO 2 Microsoft SQL Server 2014 Enterprise Edition License (60 cores) Available through Microsoft Specifications are subject to change. 2014-2016 Western Digital Corporation or its affiliates. All rights reserved. SanDisk and the SanDisk logo are trademarks of Western Digital Corporation or its affiliates, registered in the U.S. and other countries. Fusion iomemory is a trademark of Western Digital Corporation or its affiliates. Other brand names mentioned herein are for identification purposes only and may be the trademarks of their respective holder(s). HP DL580 Gen8 20160621 Western Digital Technologies, Inc. is the seller of record and licensee in the Americas of SanDisk products. 9