Intel RAID Performance 12Gb/s SAS RAID Controllers



Similar documents
Intel RAID SSD Cache Controller RCS25ZB040

Intel RAID RS25 Series Performance

Accelerating Server Storage Performance on Lenovo ThinkServer

Evaluation Report: Accelerating SQL Server Database Performance with the Lenovo Storage S3200 SAN Array

HP Smart Array Controllers and basic RAID performance factors

Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper

Performance Brief: MegaRAID SAS 9265/9285 Series

DIABLO TECHNOLOGIES MEMORY CHANNEL STORAGE AND VMWARE VIRTUAL SAN : VDI ACCELERATION

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1

Configuring RAID for Optimal Performance

Best Practices for Deploying SSDs in a Microsoft SQL Server 2008 OLTP Environment with Dell EqualLogic PS-Series Arrays

Dell Microsoft Business Intelligence and Data Warehousing Reference Configuration Performance Results Phase III

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

Accelerating Data Compression with Intel Multi-Core Processors

Using Synology SSD Technology to Enhance System Performance. Based on DSM 5.2

EMC XtremSF: Delivering Next Generation Storage Performance for SQL Server

Intel RAID Controllers

Performance Report Modular RAID for PRIMERGY

Optimizing SQL Server Storage Performance with the PowerEdge R720

EMC XtremSF: Delivering Next Generation Performance for Oracle Database

DEPLOYING IBM DB2 FOR LINUX, UNIX, AND WINDOWS DATA WAREHOUSES ON EMC STORAGE ARRAYS

QLogic 2500 Series FC HBAs Accelerate Application Performance

Using Synology SSD Technology to Enhance System Performance Synology Inc.

Best Practices for Optimizing SQL Server Database Performance with the LSI WarpDrive Acceleration Card

Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance

TEST REPORT Dell PERC H700 average percentage win in IOPS over FEBRUARY 2006 Dell PERC 6/i across RAID 5 and RAID 10. Internal HDD tests

Using Synology SSD Technology to Enhance System Performance Synology Inc.

QLogic 16Gb Gen 5 Fibre Channel for Database and Business Analytics

Virtuoso and Database Scalability

PARALLELS CLOUD STORAGE

Delivering Accelerated SQL Server Performance with OCZ s ZD-XL SQL Accelerator

As enterprise data requirements continue

How SSDs Fit in Different Data Center Applications

HP Z Turbo Drive PCIe SSD

Intel X38 Express Chipset Memory Technology and Configuration Guide

LSI MegaRAID FastPath Performance Evaluation in a Web Server Environment

Intel Solid-State Drives Increase Productivity of Product Design and Simulation

Solid State Drive vs. Hard Disk Drive Price and Performance Study

HP ProLiant DL580 Gen8 and HP LE PCIe Workload WHITE PAPER Accelerator 90TB Microsoft SQL Server Data Warehouse Fast Track Reference Architecture

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

Best Practices for Optimizing Storage for Oracle Automatic Storage Management with Oracle FS1 Series Storage ORACLE WHITE PAPER JANUARY 2015

High Performance Tier Implementation Guideline

Benefits of Intel Matrix Storage Technology

Converged storage architecture for Oracle RAC based on NVMe SSDs and standard x86 servers

Cloud Storage. Parallels. Performance Benchmark Results. White Paper.

EMC Business Continuity for Microsoft SQL Server Enabled by SQL DB Mirroring Celerra Unified Storage Platforms Using iscsi

IOmark- VDI. Nimbus Data Gemini Test Report: VDI a Test Report Date: 6, September

Accelerating Enterprise Applications and Reducing TCO with SanDisk ZetaScale Software

RAID Basics Training Guide

Windows 8 SMB 2.2 File Sharing Performance

INCREASING EFFICIENCY WITH EASY AND COMPREHENSIVE STORAGE MANAGEMENT

PowerVault MD1200/MD1220 Storage Solution Guide for Applications

Accomplish Optimal I/O Performance on SAS 9.3 with

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014

The Transition to PCI Express* for Client SSDs

EMC VFCACHE ACCELERATES ORACLE

High Performance SQL Server with Storage Center 6.4 All Flash Array

The 8Gb Fibre Channel Adapter of Choice in Oracle Environments

RAID 5 rebuild performance in ProLiant

Removing Performance Bottlenecks in Databases with Red Hat Enterprise Linux and Violin Memory Flash Storage Arrays. Red Hat Performance Engineering

Leveraging EMC Fully Automated Storage Tiering (FAST) and FAST Cache for SQL Server Enterprise Deployments

Lenovo Database Configuration for Microsoft SQL Server TB

Intel Q35/Q33, G35/G33/G31, P35/P31 Express Chipset Memory Technology and Configuration Guide

Benchmarking Cassandra on Violin

Express5800 Scalable Enterprise Server Reference Architecture. For NEC PCIe SSD Appliance for Microsoft SQL Server

8Gb Fibre Channel Adapter of Choice in Microsoft Hyper-V Environments

Lab Evaluation of NetApp Hybrid Array with Flash Pool Technology

Intel Platform and Big Data: Making big data work for you.

Intel 965 Express Chipset Family Memory Technology and Configuration Guide

VTrak SATA RAID Storage System

SUN ORACLE DATABASE MACHINE

HP ProLiant BL660c Gen9 and Microsoft SQL Server 2014 technical brief

Accelerating High-Speed Networking with Intel I/O Acceleration Technology

2009 Oracle Corporation 1

IBM System Storage DS5020 Express

IBM Software Information Management Creating an Integrated, Optimized, and Secure Enterprise Data Platform:

Intel X58 Express Chipset

Business white paper. HP Process Automation. Version 7.0. Server performance

Real-Time Big Data Analytics SAP HANA with the Intel Distribution for Apache Hadoop software

Performance characterization report for Microsoft Hyper-V R2 on HP StorageWorks P4500 SAN storage

Q & A From Hitachi Data Systems WebTech Presentation:

The Foundation for Better Business Intelligence

Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems

Dell Compellent Storage Center SAN & VMware View 1,000 Desktop Reference Architecture. Dell Compellent Product Specialist Team

Intel RAID Software User s Guide:

WHITE PAPER FUJITSU PRIMERGY SERVER BASICS OF DISK I/O PERFORMANCE

Dell Virtualization Solution for Microsoft SQL Server 2012 using PowerEdge R820

HP SN1000E 16 Gb Fibre Channel HBA Evaluation

The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage

Accelerating Business Intelligence with Large-Scale System Memory

Integrated Grid Solutions. and Greenplum

The MAX5 Advantage: Clients Benefit running Microsoft SQL Server Data Warehouse (Workloads) on IBM BladeCenter HX5 with IBM MAX5.

Accelerating Business Intelligence with Large-Scale System Memory

Comparison of Hybrid Flash Storage System Performance

NVM Express TM Infrastructure - Exploring Data Center PCIe Topologies

Transcription:

Intel RAID Performance 12Gb/s SAS RAID Controllers WHITE PAPER September 2014 DB10-000023-00 For more information on the Intel RAID visit: www.intel.com/go/raid Intel, the Intel logo, Intel Inside, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. Copyright 2014 Intel Corporation. All rights reserved. 09/14/SJ/EM/PDF Please Recycle

Table of Contents Intel RAID Performance 12Gb/s SAS RAID Controllers White Paper 3 1 Introduction 3 1.1 Architectural Benefits of 12Gb/s SAS Capable RAID 3 2 Performance Tests and Results 4 2.1 Intensive Streaming Applications 4 2.2 Transaction-Oriented Applications 7 2.3 Common Enterprise Applications 8 2.4 Microsoft SQL Server 2014 OLTP Benchmarking 10 3 12Gb/s SAS Intel RAID: Best-in-Class Storage Portfolio 11 4 Summary 11 5 Hardware Configurations Tested 11

1 Introduction The Intel 12Gb/s SAS RAID controllers, featuring the LSI dual-core SAS3108 RAID-on-Chip (ROC) processor, offer significant performance enhancements for solutions architected with 12Gb/s or 6Gb/s SAS drives. The superior read/write performance ideally suits the controllers for a broad range of application workloads: Enterprise data center applications, such as email, transactional databases, and analytical databases Cloud computing, software-defined storage systems, and big data (Hadoop) Content applications, such as streaming video and cold storage/archival The massive growth of cloud and big data applications require enterprise features to manage, optimize, and improve the efficiency of growing data centers and clusters. The Intel 12Gb/s SAS RAID controller StorCLI utility features extensive command line options that easily integrate into clustered environments, and include server storage management, both locally or remotely, from a single pane of glass with the RAID Web Console application. This generation of storage, spurred by the increased adoption and trending lower costs of flash, requires more bandwidth and I/O per second (IOPs) capability then the previous generation. Additionally, balancing power and performance in environments where solid state devices and SAS and SATA spinning hard drives coexist becomes even more critical. This paper demonstrates how Intel 12Gb/s SAS RAID controllers, with premium feature offerings such as Fast Path I/O and RAID SSD Cache, have met and exceeded this challenge. In addition to outstanding performance, the Intel 12Gb/s SAS product family supports advanced features such as multipathing, VMware ESXi virtualization, dual level advanced RAID types, and revertible hot-spare. The product family is flexible, with support for high-performance SAS hard drives, high-capacity SATA hard drives, and energy-efficient solid state drives (SSDs). 1.1 Architectural Benefits of 12Gb/s SAS Capable RAID The Intel 12Gb/s SAS generation of RAID products offer architectural changes to provide new or enhanced benefits. The new LSI SAS3108 chip combines the processing power of a dual 1.2 GHz dedicated RAID processor, low latency DDR3-1866 RAID cache, and built-in hardware acceleration engines dedicated to processing and protecting data with the lowest latencies and highest performance. The products come in multiple form factors for easy installation in most Intel-based servers. The faster clock speed and memory dramatically increase the RAID 5 and RAID 6 write capability of the controller, producing a 30% increase in performance over the previous generation products. The integrated 12Gb/s SAS capability of the controller allows for twice the SAS throughput of the previous generation with up to 1 GB/s per port transfer speed. To support the increased bandwidth, the Intel 12Gb/s SAS RAID controllers include 1 GB of RAID cache memory and an 8-lane PCI Express (PCIe ) 3.0 bus interface. These hardware features come together with a highly optimized RAID firmware stack that supports over 125% more IOPs compared to the previous generation. The added IOPs capability of Intel 12Gb/s RAID products provides a cost effective means to support an SSD environment with high performance read and write operations.

2 Performance Tests and Results Using IOMeter 1.1, an open-source I/O workload generator, Intel designed I/O workload profiles to demonstrate how real-world applications might perform. Sequential read and write benchmarks reveal how well streaming applications perform. Real-world benchmarks simulate multiple enterprise workloads that typically include mixed and overlapping reads and writes across request sizes, such as the real-world applications in the following table. Table 1 Real-World Applications Workload Streaming reads Streaming writes Workstation Web server OS drive File server Email server Enterprise databases Multithreaded reads Multithreaded writes Analytics Typical Applications Online analytical processing (OLAP), data warehousing, extract-transform-load (ETL), virtual tape library Video surveillance, medical imaging, archival, backup Scientific and office application Web serving applications Operating systems Structured file systems Server accept, deliver, store and forward applications Online transaction processing (OLTP), OLAP transactions, email applications Video on demand, Hadoop Framework, Hadoop Distributed File System (HDFS ), cloud content Hadoop source ingest (Apache Sqoop or Flume ) SQL, NewSQL and NoSQL databases, MapReduce 2.1 Intensive Streaming Applications The Intel 12Gb/s SAS RAID controllers implement eight lanes of PCIe 3.0 (8 GT/s) that provide 8,000 MBps of unidirectional bandwidth, while eight phys of third generation SAS produces 9,600 MBps of SAS bandwidth. Streaming applications focus on efficiency, storage capacity, and throughput. As the following figure shows, all RAID types provide similar high read performance of nearly 6,000 MBps. When you require highly available and protected data, there is a penalty in write performance to either provide mirrored writes (RAID 1/10) or to compute and store parity (RAID 5/6). In terms of mean time to data loss (MTTDL), RAID 0 scores the lowest followed by RAID 5, RAID 10, and RAID 6.

Figure 1 Intel Integrated RAID Module RMS3CC080 Large Streaming Reads and Writes Streaming workloads represent contiguous requests made to the disk. The workloads are predominately sequential I/O. Applications such as data warehousing, ETL, and VTL backup operations experience this type of workload for reads. Applications such as media capture (video surveillance, medical imaging, and so on), archival, and backup experience this type of workload for writes. High bandwidth is crucial for these applications. Multithreaded Workloads For multithreaded read and write workloads, high bandwidth and the ability to identify and optimally manage multiple threads are crucial for these applications. Intel 12Gb/s SAS RAID controllers can identify multiple threads and optimize the commands to reduce missed rotations and minimize disk seeks. Multithreaded workloads, while similar to streaming workloads, vary in that there are multiple simultaneous threads that typically do not overlap. This workload is mimicked by launching 1 through 24 threads at 64 KB (or larger) separated by 2 GB ranges, as shown in the following figure. Applications such as media servers (video-on-demand), cloud content delivery, Hadoop MapReduce, and HDFS experience this type of workload for reads. Big data applications such as Hadoop source ingest (Sqoop or Flume) and media operations (video surveillance) experience this type of workload for writes.

Figure 2 Intel Integrated RAID Module RMS3CC080 40x 15,000 RPM 6Gb/s SAS HDD, Multithreaded Reads and Writes The previous figures highlight the streaming bandwidth of the 12Gb/s SAS infrastructure with both SAS HDDs and SAS SSDs, bypassing the previous theoretical 6Gb/s SAS limitation and now achieving nearly 6,000 MBps. Sequential writes, in write-back mode, can exceed 4,500 MBps, while write-through mode sails to 6,530 MBps (not shown in the figures). Some workloads, such as those employed in disaster recovery plans (DRPs), truly benefit from this increase in bandwidth by improving time to optimal (TTL) when implementing restore operations. Similarly, this helps reduce scheduled backup window times an important yardstick as businesses store more and more data. Multithreaded workloads benefit too, such as allowing more simultaneous video and audio feeds, or improving Hadoop MapReduce batch job times to help customers explore their data faster.

2.2 Transaction-Oriented Applications Applications dominated by random I/O access patterns are well-suited for both SAS hard drives and SSDs. These applications include traditional and transaction capable NewSQL or NoSQL databases. Enterprise database workloads include transaction-oriented queries such as OLTP and OLAP against structured data. OLTP databases that observe ACID-compliance require high concurrency and strict in-order processing, which includes a number of data accesses: a read of the original value, followed by an update, then write and verify operation. Because these operations must be handled in order, low latency and optimal cache strategies are necessary for enterprise database performance. OLAP style processing is characterized by relatively low volume of transactions; however the queries are often very complex and involve aggregations. An 8 KB, 2:1 ratio of random reads:writes workload simulates these types of queries. Analytics is becoming increasingly popular due to the proliferation of NoSQL databases combined with declining disk cost, and innovative cost-effective distributed scale-out storage architectures that let businesses collect more data that analytic database management software can efficiently mine. Besides traditional analytics, real-time analytics such as targeted ads, security intelligence, or fraud detection require the highest performance to keep up with customer transactions. Additional features beyond traditional database management software (DBMS) (such as column-oriented storage organization, automated data replication and distributed data, write-ahead logging, and hybrid storage organization) can mean data acrobats when it comes to characterizing typical I/O operations. Analytics benchmarks typically simulate database reads, inserts, and updates; with the most common benchmarks comprised of a series of data loads followed by percentages of read, write, and insert operations. Multiple clients analytical workloads are simulated with 8 KB random 50:50 read to write ratio at high queue depths. In addition, because data access patterns can vary wildly, pure random reads and random writes are spotlighted to identify the maximum performance potential for these types of operations. Random read performance does not vary with the RAID type, but the type of data organization influences random writes. The Intel 12Gb/s SAS RAID controller cache architecture optimizes random write operations by buffering writes and sorting them in a physical order to reduce disk seek overhead. The results show a large increase in the random write IOPs combined with lower latencies, ensuring fast application response times, as shown in the following figure. Figure 3 Intel Integrated RAID Module RMS3CC080 15,000 RPM 6Gb/s SAS HDD, Transactional Workloads As customers look to increase the overall performance of their storage infrastructure, SSDs continue to make inroads into the enterprise server market. SSDs are well-suited for server workloads that require very high IOPs. Applications that fit this profile include online transaction systems with small, random reads and writes such as reservation and ecommerce systems. The true performance advantage of Intel 12Gb/s SAS RAID controllers are best demonstrated with SSDs. Only with SSDs can you see the full performance capabilities of the Intel 12Gb/s SAS RAID controllers, as shown in the following figure.

Figure 4 Intel Integrated RAID Module RMS3CC080 12Gb/s SAS SSD, Transactional Workloads The Intel 12Gb/s SAS RAID controller exhibits incredibly high performance, easily achieving more than 500,000 8-KB random reads - nearly 4,000 MBps. This translates to more than 100,000 database operations for a typical RAID 10 configuration, and even a more capacity-optimized RAID 5 configuration can still achieve upwards of 70,000 database type IOPs. 2.3 Common Enterprise Applications Workstation workloads represent primarily single tenancy operating systems running multiple applications that predominately handle random read requests, with a mix of sequential reads and writes. Low response times and effective caching strategies are essential for workstation users. Web server workloads typically service multiple, primarily random simultaneous requests. Text, images, video, and audio are commonly featured files served by web servers, with a high skew towards the most popular web pages. Low response times are critical to support fast page loads and ensure customer satisfaction. Operating system drive workloads represent the I/O activity of an operating system drive. This workload is defined as a pseudo random 70:30 mix of reads and writes combined with small sequential I/Os that simulate logging. Operating systems must manage system cache, metadata and application code and effective caching of frequently accessed data, while maintaining data integrity. The ability to handle numerous outstanding requests is absolutely essential. With the extensive use of virtualization and distributed file technologies, optimal OS performance is more important than ever. File server workloads are characterized by a large number of users requesting access to structured reference data and files. While file systems and access patterns can vary significantly, we measure 80:20 random read and write workload with the majority of request sizes ranging, bimodally balanced, around 4 KB and 64 KB. Email server workloads typically service multiple simultaneous requests to transport or store email. Many email servers use databases or database-like structures to manage and store user data. Because of the variations in email server applications, two common types of email servers were simulated in testing: 1. 8 KB 50% mix of random reads and writes 2. 32 KB 65% mix of random reads and writes The following figures show the common enterprise application performance testing results at 6Gb/s SAS and 12Gb/s SAS.

Figure 5 Intel Integrated RAID Module RMS3CC080 15,000 RPM 6Gb/s SAS HDD, Common Enterprise Workloads Figure 6 Intel Integrated RAID Module RMS3CC080 12Gb/s SAS SSD, Common Enterprise Workloads

2.4 Microsoft SQL Server 2014 OLTP Benchmarking IOmeter simulation characterizes performance well, however real applications have multiple system interactions that are hard to capture in an artificial benchmark. To determine the true database capabilities of the Intel 12Gb/s SAS RAID controller, it was measured using a Microsoft SQL Server 2014 database and a standard benchmark that exercises complex transactional operations modeled after a brokerage house. This benchmark allowed measurements and observations of the Intel RAID SSD cache benefits from one to four SSDs, as shown in the following steps and charts. 1. Database loaded with data for 10,000 customers. 2. Baseline measurement taken with only SAS HDDs. 3. Added SSDs 1 to 3 (for RAID 0), and 2 and 4 (for RAID 10), configured with both read and write caching and assigned to the database volume. 4. Tests ran for four hours. After each four-hour run, the average transactions per second and the SQL Server Page IO Latch Wait Time was recorded. 5. The database was restored to its original state. The results are quite astounding. Figure 7 Intel Integrated RAID Module RMS3CC080 Microsoft SQL Server 2014 OLTP Benchmark Three disks in a RAID 0 SSD cache volume provided the highest increase of 381%, and even a protected RAID 10 produced a very generous 167% increase in the number of achieved transactions. Using the SSD cache feature is one of the most cost effective ways to enhance application performance, especially when working with hot user data.

3 12Gb/s SAS Intel RAID: Best-in-Class Storage Portfolio The Intel 12Gb/s SAS controller portfolio provides channel partners with best-in-class storage solution options. Intel enables channel partners to stay ahead of today s technology by offering controllers perfectly suited for database, email, and Web server environments where performance and security directly affect success. The Intel 12Gb/s SAS mainstream product family uses an LSI SAS3108 ROC processor (1.2 GHz) to provide the following features: Four- (RS3DC040) or 8- (RS3DC080) internal ports SFF-8643 internal connectors RAID 0, 1, 5, 6, 10, 50, 60 support x8 PCI Express 3.0 (8 GT/s per lane) support 1-GB DDR3 at 1866 MHz support SAS and SATA drive type support Low profile board 4 Summary When architecting a RAID solution, give careful consideration to understanding the characteristics, data availability, storage architecture, and any applications for which the storage controller will be deployed. The Intel 12Gb/s SAS RAID controllers provide optimum performance in many different environments. Features such as intelligent write back RAID cache, adaptive read ahead, various stripe size support, multi-level RAID architectures, dedicated and global hot spare support, and SSD caching allow IT professionals to customize their storage environment to ensure the highest performance and data availability. Intel offers a wide range of RAID products to architect a highly optimized and scalable solution specifically for your environment. By using advanced technology, world-class features, and a SAS design that allows for SAS, SATA and SSD drives, Intel RAID allows you to balance performance, reliability, and cost requirements. 5 Hardware Configurations Tested Intel Server Board S2600WTT 2x Intel Xeon E5-2695 v2 CPUs at 2.3 GHz 64-GB DDR3-1600 Memory x8 Generation 3.1 PCIe slot Intel RAID Controller RMS3CC080 Firmware version 4.230.20-3423 Driver version 6.600.21.08 1-GB RAID cache Drive Enclosures 2x Serial Cables SA-ENC12G-01A + 1x Serial Cables SA-ENC12G-024A with the LSI SAS 3x48 C1 expander (firmware version 0.05.00.00)

Drives 40x Seagate ST9146853SS 146 GB 6Gb/s 15,000 SAS drive 8x Hitachi HUSMM8020ASS200 200 GB 12Gb/s SAS SSD Disk cache always disabled Test Suite Windows Server 2012 R2 Standard 64-bit IOMeter Version 1.1.0 SSD data tested with 64-KB stripe size, Write Thru, Direct IO, and No Read Ahead policies SSD drives preconditioned to steady state before taking measurements HDD data tested with 256-KB stripe size, Write Back, Direct IO, and Adaptive Read Ahead policies Run time: 30 seconds Ramp time: 30 seconds Queue depth sweep from 1 to 256 Raw disk access (no file system) Microsoft SQL Server 2014 Database: 20x drive RAID 10, 256-KB stripe size, Write Thru and No Read Ahead policies Log Drive: 4x drive RAID 5, 256-KB stripe size, Write Back and No Read Ahead policies 100,000 Customer database, 4 hour run time NOTE Although testing was performed with the RMS3CC080 modular controller, expect similar performance from other Intel 12Gb/s SAS RAID models, based on the similar product architecture. For more information on the Intel RAID visit: www.intel.com/go/raid INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel may make changes to specifications and product descriptions at any time, without notice. The information here is subject to change without notice. Do not finalize a design with this information. Intel, the Intel logo, Intel Inside, Xeon and Xeon Inside are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. Copyright 2014 Intel Corporation. All rights reserved. 09/14/SJ/EM/PDF Please Recycle