Model DH436R-A and DH536R-A Heated, Drum-Mounted Recirculating Parts Cleaner Operations and Maintenance Instructions



Similar documents
Benchtop Series Ultrasonic Cleaning Tanks Operations and Maintenance Instructions

15GAL STEEL OIL DRAIN WITH 110V PUMP

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

3 WATT LED SPOTLIGHT Model No. SLM

PAINT SPRAY GUN WASHER

Instruction Manual. SonicMax Ultrasonic Cleaning Systems. Graymills

LKN-Series LIFTKLEEN Parts Washer Aqueous and Solvent Models Operations and Maintenance Instructions

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

CARING FOR YOUR WATER HEATER

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

IMPORTANT SAFETY RULES TO FOLLOW

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

TR-SERIES LIFTKLEEN PARTS WASHER HEATED/AQUEOUS For units manufactured after January 2011

4 in 1 Air Compressor

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Rules for Safe Operation

ClearView 100. Instruction Manual

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Ceiling Mount Air Handler Manual

Instruction Manual. AWK-115S

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Dehumidifier Users manual. For Models: DH45S DH65S

Troubleshooting Guide for Dispenser Model #900172

Ultrasonic support removal tank

Safety, Operation and Maintenance Manual with Parts List

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

SunMaxx Solar Filling Station Operating Instructions

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Bottom Loading Water Dispenser

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Customer Support

Leak Detection System

Peasouper Operator s Manual

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

GAS SAFETY PRECAUTIONS

USER S MANUAL HSC-24A

Hydraulic Transmission Jacks Operating Instructions & Parts Manual

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

Instructions & Safety Information Models A220-20D and A220-20L Version 2

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Please read and keep these instructions. Run water through your machine before first use

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions

National- Spencer Inc.

Installation Instructions

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Mini-led spotlight with magnetic base

MODEL G300 BRAKE BLEEDER

Super Cascade Filtration Systems (CE)

1/3 HP Submersible Sump Pump with Vertical Float Switch

55-Gallon Dispenser Package

MODEL # Introduction

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Rexroth Hydraulic Pump A10VO Series User Manual

Oil and Coolant Circulating Heating System. Model - OCSM

ROTOR LOADER OWNER S MANUAL

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

Portable Air Conditioner

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Cambridge Electric Infared Fireplace User Manual

LKN-Series LIFTKLEEN Parts Washer Aqueous and Solvent Models Operations and Maintenance Instructions

Owner s manual Keurig K-Cup K10 MINI Plus Brewer

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Instruction Manual. Fun Pop 8oz. Popper

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

PC1130 Electric Air Compressor

OUTDOOR GAS FIREPLACE USER GUIDE North America _2 EF

B150 Series Commercial Brewer. Direct Plumb Kit

Float and Thermostatic Traps Series H, C and X

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

The Storm 20-Gallon Wet/Dry Vac

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Li Battery Pack & Charger Safety & Operating Instructions

SDX Submersible Depth Transmitter User Manual

Geyser-R Heat pump water heater Installation manual

Transcription:

Graymills Model DH436R-A and DH536R-A Heated, Drum-Mounted Recirculating Parts Cleaner Operations and Maintenance Instructions Be sure anyone operating this unit reads and understands all warnings and instructions. Keep this manual available for reference/training. SAFETY WARNINGS You will find various types of safety information on the following pages and on the labels attached to Graymills equipment. The following Safety Statements explain their meaning: This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid personal injury or death. DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION, without the safety alert symbol, is used to address practices not related to personal injury. READ BEFORE OPERATING Use only Aquatene TM 330 or Super Aquatene TM 360 cleaning solution. Do NOT use solvents, gasoline, etc., as they will create an extremely hazardous situation. Do NOT contaminate cleaning fluid with any flammable or combustible material such as gasoline, alcohol, mineral spirits, etc. Drain parts to be cleaned of any flammable material or combustible material before cleaning. Even small quantities can create a dangerous fire hazard. Never work with equipment you feel may be unsafe. Contact your supervisor immediately if you feel a piece of equipment is in unsafe condition. Cleaning solutions may be irritating to skin and eyes. Always wear gloves, apron and safety glasses when using. If splashed in eyes, flush thoroughly with water and follow directions on cleaning solution MSDS. See USE OF INDUSTRIAL CLEANING SOLUTIONS on page 2. Install machine in a well ventilated area. Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 1

The unit has been factory set to maintain an approximate optimal temperature of 110. Do NOT attempt to change thermostat setting. This is a heated system. Always use caution when first putting hand under liquid stream to prevent injury from heated solution. If the liquid feels uncomfortably hot, discontinue use, unplug machine and call Graymills Customer Service. Failure to keep proper liquid level will result in burning out the pump and heater coil, creating a potential fire hazard. To help prevent this, this unit is equipped with a low liquid level device which will shut off the pump and heater. If solution stops circulating and the red RESET light becomes illuminated, immediately turn off and unplug unit. For instructions on filling the reservoir, please see INSTALLATION AND OPERATION steps 6 through 8. DH436R Only After extended use, the gas-spring used to assist in opening and closing the lid may lose its ability to keep the lid open. At the first sign of this, replace the gasspring immediately. Automatic Safety Cover. Since certain soils may be combustible, e.g., oils, greases, this unit is equipped with a fusible safety link cover mechanism designed to support the open cover at a slightly forward angle. In the event of a fire, the fusible link will melt at 165ºF permitting the cover to slam shut, limiting oxygen supply to the fire. Do not leave the unit unattended with parts in the tank which would prevent the cover from closing completely in the event of a fire. Keep cover closed when unit is not in use. If the fusible link breaks, do not operate the unit until a replacement link is installed. Turn pump and/or power off if unit is to be idle for extended periods (overnight and weekends). POWER SUPPLY, WIRING AND GROUNDING Failure to permanently ground the unit and controls before connecting to electrical power can cause shock, burns or death. Install ground and wiring according to local and national electrical code requirements. Install a fused disconnect switch on all power legs near the unit Disconnect and lockout electrical supply before installing or servicing unit. Unit must be properly grounded to prevent electric shock hazard. Connect only to three-prong outlet. Should cord become cracked, frayed or damaged in any way, it should be repaired/replaced immediately by a qualified electrician. Never use an extension cord. (See Spare Parts List) The full-load amperage draw for this machine is 12 amps. USE OF INDUSTRIAL CLEANING SOLUTIONS Always wear the recommended safety apparel and glasses. Adequate ventilation should be provided when operating this unit. When making an initial batch of cleaning solution or when adding compound, follow cleaning solution s directions exactly. Industrial cleaning solutions may be irritating to some individuals. Be certain to consult the MSDS for the cleaning solution you are using before filling or using parts washer. If splashed in the eyes, follow cleaning solution MSDS instructions. If cleaning solution is splashed on clothing, remove promptly and thoroughly wash any body areas which have been in contact with solution. DO NOT permit saturated clothing to remain in contact with skin. Consult cleaning solution s MSDS instructions. Clean up fluid spills immediately. Cleaning solutions can create a slippery surface and could damage floor coverings or painted surfaces. Graymills strongly recommends that federal, state and local authorities be consulted before proceeding with discarding and handling of used materials. Graymills Corporation accepts no responsibility for user s failure to comply with regulations. For best results, Graymills recommends using only Aquatene TM 330 or Super Aquatene TM 360. Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 2

MACHINE INSTALLATION AND OPERATION 1. Place unit on a smooth, level surface in a well ventilated area. 2. Install backsplash as show to the right (DH536R only). 3. Read all warnings posted on machine. 4. Inspect electrical control box, cord and plug for wear or damage. Do not use machine or add fluid if any wear or damage is noticed until impaired components are repaired or replaced. 5. Install filter cartridge: a. Unscrew filter cartridge bowl. b. Remove clear plastic packaging from filter cartridge. Remove and discard BIO- POUCH from hollow center of cartridge. c. Install new filter cartridge in the cartridge bowl. d. Re-attach filter cartridge bowl to filter body. Be sure electrical cord is unplugged and cleaning solution and heater coil is cool before adding cleaning solution or performing any maintenance. 6. Remove center sink drain (stainless steel strainer basket, mesh strainer assembly). 7. Add 30-gallons of Aquatene TM 330 or Super Aquatene TM 360 solution to the base reservoir tank. 8. Put center sink drain assembly back into sink drain opening. 9. Plug power cord into properly grounded 115V, 15 amp circuit. Full load amp-draw of unit is 12 amps. 10. Press TEST button on GFCI on rear of control (right) to ensure switch is operating properly. Press RESET button on GFCI to prepare unit for operation. 11. Air pump will begin operation immediately upon power being applied to the machine and the red RESET light will illuminate. 12. Toggle RESET switch located under the electrical box to begin operation. If the unit has an adequate level of cleaning solution in the tank, the green READY light will illuminate and the red RESET light will extinguish. 13. The amber HEAT light indicates power to the heater. 14. If cleaning solution is not at the appropriate temperature and heat is required you should hear the thermostat engage with a CLICK and the amber HEAT light will illuminate. Should this not happen, press the red thermostat reset button on the rear of the control box (right). Should this problem persist: unplug machine and call factory. 15. When the unit reaches its predetermined temperature, the HEAT light will extinguish, indicating the cleaning solution is at the proper temperature to obtain maximum cleaning efficiency. For maximum cleaning efficiency, allow heater to warm solution for 2 to 4 hours before use. 16. To operate the fluid pump, toggle PUMP switch on front of electrical box to the ON position. 17. For fluid via the flexible hose turn the directional valve counterclockwise to the left. 18. For fluid via the flow-thru brush turn the directional valve clockwise to the right. Backsplash Assembly for DH536R-A Operator Interface DH436R-A and DH536R-A Front and Back When not in use return flow-thru brush to brush clip holder to holder to avoid obstructing lid closure (DH436R only). 19. Failure to keep proper liquid level will result in burning out the pump and heater coil, creating a potential fire hazard. To prevent this, this unit is equipped with a low liquid level device which will shut off the pump and heater. If solution stops circulating and the red RESET light becomes illuminated, immediately turn off and unplug unit. Follow steps 6 through 8 above for instructions on refilling unit. 20. When finished, turn pump off and close lid to minimize liquid loss due to evaporation (DH436R only). Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 3

RECOMMENDED NORMAL MAINTENANCE Be sure electrical cord is unplugged and cleaning solution and heater coil is cool before performing any maintenance. 1. Check fluid level in unit daily. 2. Due to evaporation and drag-out, fluid should be topped off with Aquatene TM 330 or Super Aquatene TM 360 cleaning solution as needed. 3. Inspect strainer basket daily. Remove and dispose of solid waste accumulation. To assure proper drainage rinse out vapor barrier filter daily. 4. Check operation of liquid level control. Make sure that float switch moves freely up and down. 5. Unit is equipped with a blue temperature-sensitive label on the front of the reservoir. When solution is heated, the temperature change will cause the label to change from blue to pink. The change will occur only at or below the liquid level, allowing the level to be determined without having to look through the drain or remove the sink. When control assembly is removed from reservoir, care must be taken not to damage components. 6. Inspect heating coil monthly, remove any deposits or build up with a soft wire brush. Deposits and build up can cause premature failure of the heating coil. 7. Filter cartridge will require periodic replacement depending on the volume and types of soils involved. A significant reduction in the flow through the flexible hose signals the need to replace the cartridge (see RECOMMENDED ANNUAL MAINTENANCE). Order replacement cartridges, part number BIOFL1, from either your Graymills distributor or the factory. 8. After extended use, the gas spring used to assist in opening and closing the lid on model DH436R may lose its ability to keep the lid open. At the first sign of this, replace the gas spring immediately. Order part number 765-09631. RECOMMENDED ANNUAL MAINTENANCE Graymills recommends that the entire system be inspected and cleaned annually. To perform this maintenance: Be sure electrical cord is unplugged and cleaning solution and heater coil is cool before performing any maintenance. 1. Remove sink drain filters and rinse. 2. Clean filter cartridge assembly: a. Unscrew filter cartridge bowl. b. Pour liquid from filter bowl into reservoir. c. Remove filter cartridge and dispose of in proper manner. d. Remove clear plastic packaging from filter cartridge. Remove and discard BIO-POUCH from hollow center of cartridge. e. Install new filter cartridge in the cartridge bowl. f. Re-attach filter cartridge bowl to filter body. 3. Unscrew sink hold downs. 4. Lift sink straight up until mounting ring clears reservoir and set to the side. 5. Lift off control assembly being careful not to damage heater, float switch or pump. When control assembly is removed from reservoir, care must be taken not to damage components. 6. Visually inspect pump, pump inlet filter, heater float switch, and tubing for damage or wear. 7. Replace all parts as necessary. Make sure all tie-offs for pump, heater and float switch are still in place insuring proper separation and alignment of these components. 8. Clean excess accumulation off heater coil with a soft wire brush. 9. Inspect surface of cleaning solution and skim to remove any oil or debris. 10. Pump cleaning solution into acceptable container for future reuse. 11. Rinse inside of reservoir tank with clean water. 12. Refill reservoir tank with saved solution from step 10. 13. If necessary, top-off cleaning solution with enough fresh of Aquatene TM 330 or Super Aquatene TM 360 cleaning solution to bring reservoir up to 30-gallon mark. 14. Replace control assembly and sink. 15. Follow steps 8 through 12 in MACHINE INSTALLATION AND OPERATION to complete annual maintenance. Save this manual for future training. Do not allow operation without reading and understanding these instructions. Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 4

TROUBLESHOOTING Problem Probable Cause Suggested Remedy No Machine Function Heat Not Working Red RESET Light ON Little or No Fluid Flow Machine unplugged GFCI tripped No power at outlet Thermostat tripped Plug machine into appropriate wall socket Press RESET button on GFCI Consult plant electrician Press red thermostat reset button Heater malfunction Contact Graymills for more information 1-888-472-9645 Heater coil dirty Machine needs to be reset Low solution level Float sensor or control relay malfunction Valve shut off Clogged filter Cracked or broken hose Clean heater coil (see Recommended Maintenance) Toggle RESET switch Add cleaning solution Contact Graymills for more information 1-888-472-9645 Turn valve fully to the left or right to open valve Replace filter cartridge (Part #BIOFL1) Inspect and replace hose (See parts list) If your problem is not listed above or problems persist, please contact Graymills for further assistance. 1-888-472-9645 Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 5

DRAWINGS AND PARTS LISTS DH436R-A DH536R-A Items common to both the DH436R-A and the DH536R-A DH436R-A Only REF DESCRIPTION PART NO. Complete Electrical Control Ass y 457-40313 Toggle Switch (Pump) 770-09192 Electrical Control Assembly Components (Not Shown) Toggle Switch (Reset) 770-92011 Toggle Switch Boot 770-08481 Indicator Light Green 772-92079 Indicator Light Amber 772-92078 Indicator Light Red 772-92080 GFCI 115V 777-09499 Float Switch 770-90167 Heater 780-90166 Pump 390-09663 Tube Bulkhead Compression Fitting 735-91249 ¼ Air Tubing 729-90678 8 Power Cord and Plug 777-04152 Relay 782-92066 Relay Socket 782-92126 Rubber Condensation Guard 744-37878 Polyurethane Foam Filter 742-90883 3/8 Trim Bulb 603-37983 15 Tank 727-37995-GRAY 16 Drum 727-37883-GRAY 17 Ring 727-37995R-GRAY 18 Black Neoprene Hose 729-90327 19 Lockline Adapter 728-90796 20 Gripper Clip 769-90170 21 3-Way Fluid Valve 738-90795 22 Flex Hose and Nozzle Assembly 728-90951 23 Strainer 715-26971-81 24 Vapor Barrier 742-90144 25 Filter Cup 742-34222-81 26 Ring Mounting Thumb Screws 753-04325-81 27 Flow-Thru Brush with Hose 749-09925 28 Filter Housing 742-90186 29 Filter Cartridge BIOFL1 30 Filter O-Ring 744-90187 31 Lid 727-34157-GRAY 32 Gas Spring Assembly 765-09631 33 Fuse Link Assembly Bracket 432-34800-81 34 Linkage Bracket 435-39511-81 35 Fuse Link Assembly 451-23482 N/A DH536R-A Backsplash Assembly 402-38092 Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 6

ELECTRICAL SCHEMATIC WARRANTY INFORMATION Graymills Corporation warrants that the equipment manufactured and delivered, when properly installed and maintained, shall be free from defects in workmanship and will function as quoted in the published specification. Graymills does not warrant process performance, nor assume any liability for equipment selection, adaptation, or installation. Warranty does not apply to damages or defects caused by shipping, operator carelessness, misuse, improper application or installation, abnormal use, use of add-on-parts or equipment which damages or impairs the proper function of the unit, and modifications made to the unit. Warranty does not apply to expendable parts needing replacement periodically due to normal wear and tear. A new Warranty period shall not be established for repaired or replaced materials or products. Such items shall remain under Warranty for only the remainder of the Warranty period of the original material or product. THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, WHETHER ORAL, WRITTEN, EXPRESSED, IMPLIED OR STATUTORY. GRAYMILLS CORPORATION MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESTATED OBLIGATION ARE HEREBY DISCLAIMED BY GRAYMILLS CORPORATION AND EXCLUDED FROM THIS SALE. Graymills warranty obligations and Buyer remedies (except to title), are solely and exclusively stated herein. In no case will Graymills be liable for consequential damages, loss of production, or any other loss incurred due to interruption of service. Graymills' obligation under this Warranty shall be limited to: 1. Repairing or replacing (at Graymills sole discretion) any non-conforming or defective component within one year from the date of shipment from Graymills. 2. Repairing or replacing (at Graymills sole discretion), components supplied by, but not manufactured by Graymills, to the extent of the warranty given by the original manufacturer. Buyer must give Graymills prompt notice of any defect or failure. If you believe you have a Warranty claim, contact Graymills at (773) 248-6825. Any return material must have an RMA number on the outside of the package and shipping prepaid or shipment will be refused. Graymills will promptly examine the material and determine if it is defective and within the Warranty period. Graymills Corporation 3705 N. Lincoln Ave. / Chicago, IL 60613 Phone: 773.477.4100 Fax: 773.477.8673 www.graymills.com 7