21 st Century Campus Network Responsibility Matrix 5/26/10



Similar documents
Network Design. Yiannos Mylonas

SECTION 13: COMMUNICATIONS CONTENTS

WINNEBAGO COUNTY INFORMATION TECHNOLOGY STANDARDS 2014/2015

DALLAS INDEPENDENT SCHOOL DISTRICT PURCHASING DEPARTMENT ADDENDUM No. 2 NETWORK ELECTRONICS

IS Network Services Senior Facilities Management Group 2 Hill Farms West Division of State Facilities

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications


SERVICE LEVEL AGREEMENT SILVER SUPPORT LEVEL EITS NETWORK SUPPORT PARTNERSHIP FY 2012

Information Technology Mission Statement. Information Technology Goals

TrueAlarm Fire Alarm Systems

Cisco Network Switches Juniper Firewall Clusters

ITI Network Infrastructure & ITI to Dekouene Wireless Bridge ABDULLAH ABDULLAH AYMAN AL-HAKIM BASHIR WAHHAB

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. Slide Number 1

High Speed Ethernet. Dr. Sanjay P. Ahuja, Ph.D. Professor School of Computing, UNF

Auspex Support for Cisco Fast EtherChannel TM

Request for Proposal- Network Switches and Professional Services

Universal Network Access Policy

Chapter 4 Connecting to the Internet through an ISP

IP Telephony Management

Structured Cabling Network Services & Equipment Inside/Outside Plant Design Trenching

Automating Infrastructure A connectivity perspective for BICSI SEA meeting, November 2011

Layer 3 Network + Dedicated Internet Connectivity

Campus Network Best Practices: Core and Edge Networks

CABLING REQUIREMENTS:

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Network Infrastructure

Networking Devices. Lesson 6

Network Design Incorporated

Project Scope Statement

Planeamento e Gestão de Redes. Análise de Requisitos

Sure Data Centre Bandwidth and Network Access Service Specific Terms and Conditions and SLA

Wireless and Wired Networking Specifications

Advanced Network Services Teaming

Oracle Big Data Appliance: Datacenter Network Integration

Client Security Risk Assessment Questionnaire

Computer Networking. Definitions. Introduction

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Net Optics Learning Center Presents The Fundamentals of Passive Monitoring Access

2015 Piqua City Schools RFP for Network Equipment under E-Rate Category 2

What is a Datacenter?

Request for Proposals Voice over Internet Protocol Unified Communications System /2016

Upgrading Path to High Speed Fiber Optic Networks

JOB OPENING. Please see attached Job Description: Last day to apply: February 27, 2013

Top-Down Network Design

Security & Surveillance Cabling Systems

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Voice over IP System

Digital/Unified Telecommunications Services - District-Wide, Hosted VoIP Telephony Solution, beginning in the Erate funding year 16

TELECOMMUNICATIONS & NETWORK SERVICES

APPENDIX 3 LOT 3: WIRELESS NETWORK

WINNEBAGO COUNTY INFORMATION TECHNOLOGY STANDARDS 2012/2013

Implementing Managed Services in the Data Center and Cloud Space

Questions and Answers

Norfolk Community Fiber Optic Network

How To Increase Network Performance With Segmentation

John Ragan Director of Product Management. Billy Wise Communications Specialist

Cabling and Building Infrastructure for Technology

Question and Answers RFP # IP Phone System

Elisa Carrier Services. Elisa Operator Broadband Services. Technologies, distribution centres and delivery interfaces

Transformation of the Enterprise Network Using Passive Optical LAN

Chabot-Las Positas Community College District Bond Measure Technology Improvements Supplement to Capital Improvement Program

Cisco Advanced Services for Network Security

SummitStack in the Data Center

DISASTER RECOVERY AND NETWORK REDUNDANCY WHITE PAPER

i. Each building s network connections are routed through Cisco Small Business Switch SG or 36.

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

Wired and Wireless Network Request for Proposal New Washington County High School Facility

In this section of notes you will learn the rudiments of networking, the components of a network and how to secure a network

Planning a Network Upgrade

VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR NETWORK SWITCHES TEST PLAN

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration.

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

State of Texas. TEX-AN Next Generation. NNI Plan

PON Technology A Shift in Building Network Infrastructure. Bob Matthews Technical Manager CommScope Canada

Virtual Stacking. White Paper

Unit Network Infrastructure Maintenance. Standard Service Agreement (SA)

Optimizing Infrastructure Support For Storage Area Networks

Managed ICT Services. User Guide. Possibilities that are built in. Telstra Corporation Limited ABN

IT-AD08: ADD ON DIPLOMA IN COMPUTER NETWORK DESIGN AND INSTALLATION

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

Hosting Services - Dedicated Service Agreement Page 1 of 6

Voice Over IP (VOIP) Phone System Invitation to Bid

Enabling Internet Connection Sharing on Windows Enabling ICS On Windows XP As The Host 4 Enabling ICS On Windows XP As The Client 11

Cisco Network Performance Evaluation Using Packet Tracer

SUBJECT: Network Support Partnership Silver Support Level for FY 2013

IT Assessment Report. Prepared by: Date: BRI Works East Main Street, Suite 200 Charlottesville VA

Local Area Networks (LANs) Blueprint (May 2012 Release)

Connecting to the Internet. LAN Hardware Requirements. Computer Requirements. LAN Configuration Requirements

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Information and Communication Technology Network Cabling Infrastructure Standard

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Lab Developing ACLs to Implement Firewall Rule Sets

APPENDIX 8 TO SCHEDULE 3.3

Networking Systems (10102)

Region 10 Videoconference Network (R10VN)

Request for Proposal for Telephone System Hosted VoIP System On Premise VoIP System Hybrid IP System #RFP PHONE SYSTEM 1

Chapter 2 TCP/IP Networking Basics

IT Security Standard: Network Device Configuration and Management

INTERIM MARKET DOCUMENT CHANGE

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

Transcription:

Definitions: DoIT Standards This column details the minimal configuration, which DoIT has defined in order to provide a campus-wide standard level of service. Departments may request services, which exceeds these standards. DoIT will develop a review process to address these requests. Central Management This column details the responsibilities for managing the network components when a department/division elects to have DoIT provide support to the faceplate. There is no Authorized Agent to provide onsite support. Collaborative Management This column details the responsibilities for managing the network components when a department/division elects to have management where a local Authorized Agent within the department may manage specific network functions. Although the Authorized Agent may perform specific network functions, DoIT will provide support and backup. Delegated Management This column details the responsibilities for exceptional instances where DoIT has delegated responsibilities for managing portions of the building network to the site s Authorized Agent. Management is delegated only with a request from the Dean or division head and approval from the campus IT Executive Committee. Authorized Agent Department personal who are certified by DoIT to perform data network operations in telecommunication rooms. Information in cells extending across more than one column apply to all the columns which the cell extends under. Components/Activity DoIT Standards Central Management Collaborative Management Delegated Management Workstation & Horizontal Network 1.1 Network Interface Card (NIC) Primary: 10/100 Mbps NIC Secondary: 10/100/1000 Departments are responsible for providing, installing and servicing the user s NIC, unless the department has contracted DoIT to provide desktop services. 1.2 NIC to Wall-plate patch cable Mbps NIC Primary: Category 5e cable, any color Secondary: Category 6 cable, any color 1.3 Wall plate Primary: Category 5e compatible RJ-45 jacks Alternate: Category 6 compatible RJ-45 jacks 1.4 Horizontal wiring - copper 1.5 Horizontal wiring - fiber Primary: Category 5e wire Alternate: Category 6 wire Primary: Multi-mode fiber Department s are responsible for providing, installing and servicing any patch cable, mini-switch or hub used in an office, lab or server space outside the building s telecommunication rooms, unless the department has contracted DoIT to provide desktop services. installing and servicing the communications wall plate for initial installations and additional requirements. Departments are responsible for cost of relocating wall plates resulting from remodeling projects. installing and servicing the horizontal copper wiring. DoIT will provide and install additional horizontal wires as required by departments. Upgrades will be coordinated with building remodeling projects were appropriate. FP&M or outside contractors will perform the installations. installing and servicing the horizontal fiber cabling. DoIT will coordinate installation of additional horizontal cables as required by departments. Upgrades will be coordinated with building remodeling projects were appropriate. FP&M or outside contractors will perform the installations. 1

Building Network 2.1 Main Distribution Facility (MDF) and Intermediate Distribution Facility (IDF) Telecommunication Rooms 2.2 Copper wire patch 2.3 Fiber cable patch 2.4 Patch panel to network access equipment patch cables See Telecommunication Room Design Standards Primary: Category 5e patch Alternate: Category 6 patch Primary: Multi-mode fiber Primary: Category 5e cabling Alternate: Category 6 cabling The departments along with Space Management are responsible for providing adequate space for telecommunication rooms. DoIT is responsible for configuring the space and installing equipment. DoIT will coordinate upgrades with building remodeling projects where appropriate. DoIT will maintain physical access to the MDF and IDF rooms. The departments along with Space Management are responsible for providing adequate space for telecommunication rooms. DoIT is responsible for configuring the space and installing equipment. DoIT will coordinate upgrades with building remodeling projects where appropriate. DoIT will maintain physical access to the MDF and IDF rooms. Authorized Agents will have access to the rooms. installing and servicing copper wire patch, including connecting horizontal wires to the ports. DoIT will coordinate the installation of additional patch as required by departments. Upgrades will be coordinated with building remodeling projects were appropriate. FP&M or outside contractors will perform the installations. installing and servicing fiber cable patch, including connecting horizontal cables to the ports. DoIT will coordinate the installation of additional patch as required by departments. Upgrades will be coordinated with building remodeling projects were appropriate. FP&M or outside contractors will perform the installations. installing and servicing telecommunication room patch cables and fiber jumpers. DoIT will stock additional cables as required. installing and servicing telecommunication room patch cables and fiber jumpers. The Authorized Agent may install Cat 5e or 6 patch cables as part of an upgrade project or to add additional capacity. The Authorized Agent must open a service request for Cat 3 cable connections. DoIT will stock additional cables on site. providing patch cables to the department s Authorized Agent. The Authorized Agent will install and service these patch cables. 2

2.5 Network access equipment 2.6 Network access equipment IOS 2.7 Network access equipment spares See 21 st Century Network Standard: Network Electronics. This document defines the standard network capacity as 100 Mbps between the workstations and network access equipment and 1Gbps between the network access equipment and building concentration equipment. Latest DoIT approved Cisco IOS with appropriate patches. DoIT will maintain on campus, a sufficient quantity of each network access equipment models used in the network. installing and servicing network access equipment. DoIT will maintain ownership of the equipment and maintain appropriate maintenance as required. installing and servicing network access equipment. DoIT will configure and install the equipment with the assistance of the Authorized Agent. DoIT and the Authorized Agent will monitor capacity, and as required, DoIT will size, configure and install the additional equipment with assistance of the Authorized Agent. DoIT will maintain ownership of the equipment and maintain appropriate maintenance as required. installing and servicing campus standard IOS version and patches. DoIT will perform installation through a centralized update method. Departments will be notified prior to activation of the IOS upgrade. DoIT will maintain current backup copies of access equipment configurations. maintaining spare equipment at a central location and replacing equipment as required. DoIT will load the most recent backup configuration. DoIT will maintain ownership of the equipment. providing the network access equipment. DoIT will design the network access equipment with the department s Authorized Agent. The Authorized Agent is responsible for installing and configuring the equipment as well as monitoring capacity. If additional capacity is required, DoIT will size and provide additional equipment with assistance of the Authorized Agent. DoIT will maintain ownership of the equipment and maintain appropriate maintenance as required. defining campus standard IOS version and patches. Authorized Agents are responsible for obtaining, installing and servicing the standard IOS. DoIT will notify the Authorized Agent when IOS upgrades are required and an upgrade compliance date. If the department wishes to use additional IOS features approved by DoIT, they are responsible for purchasing and installing the software. DoIT will maintain equipment at a central location for pickup and replacement by the Authorized Agent. DoIT will maintain ownership of the equipment. 3

2.8 Network access equipment to vertical fiber jumper cables Dependent on the detail requirements of the building. 2.9 Vertical fiber cables Minimum of two pair, plus growth, of multi-mode fiber optic cable to each IDF. 2.10 Vertical fiber to building aggregation equipment jumper cables 2.11 Building aggregation equipment 2.12 Building aggregation to backbone equipment jumper cable or interbuilding connection Dependent on the detail requirements of the building. See 21 st Century Network Standard: Network Electronics. This document defines the standard network capacity as 1Gbps between the network access equipment and MDF equipment as well as 1 Gbps between the building aggregation equipment and the node/supernode equipment. Dependent on the detail requirements of the building. installing and maintaining these jumper cables for the network access equipment. DoIT will maintain ownership of these cables. providing and the departments are responsible for installing and maintaining these cables. DoIT will maintain ownership of these cables. installing and servicing the vertical fiber cables. DoIT will coordinate installation of additional vertical cables as required. Upgrades will be coordinated with building remodeling projects were appropriate and performed by FP&M or outside contractors. installing and maintaining these jumper cables with the building aggregation equipment installation. DoIT will maintain ownership of these cables. installing and servicing the building aggregation equipment. DoIT will monitor capacity and install additional equipment as needed. DoIT will maintain ownership of this equipment. installing and servicing the building aggregation equipment. DoIT will design and install the building aggregation equipment in conjunction with the department s Authorized Agent. DoIT and the Authorized Agent will monitor capacity and install additional equipment as needed. DoIT will maintain ownership of this equipment. providing, installing and configuring the building aggregation equipment for buildings with multiple networks. DoIT will design and install the building aggregation equipment in conjunction with all Authorized Agents. In buildings with a single network, the Authorized Agent is responsible for configuring the equipment and monitoring capacity. If additional capacity is required, DoIT will size and install additional equipment with assistance of the Authorized Agent. DoIT will maintain ownership of the equipment and maintain appropriate maintenance as required. installing and maintaining these jumper cables with the building aggregation equipment installation. DoIT will maintain ownership of these cables. 4

2.13 Electrical service See Telecommunication Room Design Standards Backbone Network 3.1 Inter-building fiber Primary: Single-mode fiber Alternate: Multi-mode fiber which supports 1Gbps connections. contracting with FP&M or outside contractors in providing, installing and maintaining appropriate electrical service for the telecommunication room. Electrical circuits installed for the network will be for use of the 21 st Century Network equipment or department equipment approved by DoIT. Electrical upgrades will be coordinated with building remodeling projects were appropriate. DoIT will install, maintain and allocate inter-building fiber. Fiber termination will be locked in fiber cabinet. 3.2 Node and Supernode See 21 st Century Network Network equipment Standard: Network Electronics 3.3 Jumper cables Dependent on the detail requirements of the Node or Supernode. DoIT will provide, install and service any node and supernode equipment as well as the IOS. DoIT will retain ownership of this equipment. DoIT will provide, install and service all jumper cables connected to the backbone equipment. DoIT will retain ownership of these jumper cables. 3.4 Protocols IP DoIT will only route IP traffic on the backbone network. 5

Network Management and Functions 4.1 Centralized network monitoring HP Openview 6.4 - NNM 4.2 Local network monitoring 4.3 Management Access Network 4.4 Configuration backups No standard Nightly backup of changed network equipment configurations. DoIT will provide 24x7 monitoring of the network. Departments are required to maintain contact information for events that occur in the building s network. DoIT will monitor the network performance and take appropriate action. 4.5 VLANs defining VLANs and assigning ports to VLANs as identified by the department. DoIT will provide 24x7 monitoring of the network. Departments are required to maintain contact information for events that occur in the building s network. DoIT will monitor the network performance and take appropriate action. Authorized Agents will have access to traffic statistics, MAC address tracking, and IP tracking. DoIT will also monitor the network performance and take appropriate action in collaboration with the Authorized Agent. DoIT will provide 24x7 monitoring of just the department s network connection to the network. The department is required to maintain current contact information in Openview by notifying DoIT DCO of any changes. Departments may maintain network-monitoring systems for their own use so long as they do not interfere with the centralized network monitoring system or any part of the network. DoIT will provide, install and maintain a separate network for remote access to the building aggregation equipment by DoIT network engineers. DoIT will capture and store configuration backups on a central server and provide recovery of the configuration in case of hardware failure. defining VLANs and assigning ports to VLANs as identified by the department. The Authorized agent may assign ports to VLANs utilizing the Edge Port Management Tool. 4.6 Multicasting maintaining multicasting functionality on the backbone and building networks. The departments are responsible for configuration backups. defining cross-campus VLANs. The Authorized Agent is responsible for assigning ports to VLANs. The Authorized Agent is responsible for maintaining multicasting functionality for the building network. 6

Network Security 5.1 Physical access To be defined DoIT will maintain physical access to all telecommunication rooms. 5.2 Firewalls To be defined Departments may continue to use firewall solutions, however, they should be aware of redundancy and capacity shortfalls of the systems. 5.3 Intrusion detection To be defined 5.4 Vulnerability scanning To be defined 7