Electronic faucets for every occasion, every application

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

INSTALLATION INSTRUCTIONS SENSOR OPERATED LAVATORY FAUCET. EBF-85 and EBF-187 Battery Powered, Sensor Operated Lavatory Faucet

Plumbing Condensed Catalog

Spouts and Flow Regulators

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

SENSOR FAUCETS. OPTIMA ETF-80 Faucet. P a r t s G u i d e 24 VAC HARDWIRE FAUCETS SLOAN VALVE COMPANY SEYMOUR AVENUE FRANKLIN PARK, IL 60131

SURGICAL SCRUB SINKS INSTALATION-OPERATION-MAINTENANCE USER MANUAL

PLUMBING SUBMITTAL

Installation Instructions

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

MAC FAUCETS. Owner s Manual. Models: FA444

FUTRUS WALL-MOUNT VANITY SINK SOLUTIONS WITH DUPONT CORIAN

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Healthcare Solutions A MASCO COMPANY. Delta Faucet Company 55 E. 111th St., P.O. Box Indianapolis, IN 46280

BRADLEY COMMERCIAL SHOWERS AND SHOWER VALVES

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Effective Date: January 1, 2009

Electric Mini Tank Water heaters GL GL 4 - GL 6+

SHOWERS SHOWERS

Float and Thermostatic Traps Series H, C and X

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

In-Line Air Separators

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

HL Series - Commercial Heaters Tankless Water Heating Solutions

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

AIR OPERATED OIL PUMPS AND KITS

James M. Pleasants Company

AUTOMATIC CHANGEOVER MANIFOLD Series 915

SF15K SF05KSS, SF10KSS

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

PLUMBING RE-SUBMITTAL

Typical Aluminum GFM Mass Flow Meter

Your safety and the safety of others are very important.

2015 CANADIAN PRICE LIST

WATER PRESSURE REDUCING VALVES

Light Duty Commercial Electric Water Heater

See Mixing Valve Catalog (PHBRMIX) for more detailed information about the products in this section.

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Installation Instructions

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Centro-Matic Automatic Lubrication Systems System Controls

AIR LINE VALVES AND GAUGES

Isotemp Basic, Slim/B & Slim Square

Domestic Hot Water Systems and Plumbing Products

B. Select combinations of fixtures and trim and other components that are compatible.

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Operators manual Basic water heater

Electric Water Heater

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

sinksfaucets bathroomshowers riveo.co

Morrison Bros. Co. General Product Specifications

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

INSTALLATION INSTRUCTIONS MK-8704

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

NFPA31FuelOilPiping 1 Revised

Powers Controls TH 192 S Single Temperature Room Thermostat

SMITH MFG. CO. PROTECT YOUR INVESTMENTS. Automatic Backwater Valve SMITH MORRIS GROUP INTERNATIONAL.

Installation S19-220PT S19-220BPT. Wall-Mounted Eyewash with Plastic Bowl. Wall-Mounted Eyewash with Stainless Steel Bowl.

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Model 1210C Battery Powered Pump Shown. Description

How To Replace A Reverse Osmosis Water Tank

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Pilot Water Heater 6-10 Gallon

STABITHERM INSTALLATION & SERVICE BOOKLET

SECTION COMMERCIAL PLUMBING FIXTURES

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Engineering Specifications

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Copper Meter Resetters

OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual

Complete units. Complete underfloor box for one Modul 45 socket and two data connection sockets. Complete service outlets

A3650/11LMWS (Metal Lever) A3650/11LPWS (Porcelain Lever)

Installation Instructions S

Jay R. Smith Mfg. Co.

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Installation Instructions

BIS WC Element / Lyft Alpro

Air Conditioner Water Heater Model ACWH18

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

GENERAL PLUMBING REQUIREMENTS

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

INSTALLATION INSTRUCTIONS BL-8704

A. Product Certificates: Submit certificates of performance testing specified in "Source Quality Control" Article.

Installation and Operating Instruction Manual

POWERS Controls No. 4 Pneumatic Damper Actuator

The Unique Accelabar Flow Meter

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Transcription:

Electronic Wallmount Faucet 1500T4 & 1501T4 Series Specification: (example) Battery (4 C cell) or Hardwire (24 VAC) infrared electronic handwash system H 2OPTICS technology no external adjustments required Chrome plated wallmount one piece cast main body with integral sensor and rigid spout Adjustable sensing range and timeout Audible low battery indicator Forged brass solenoid valve (control box No. 0 only) Tempered water supplied to solenoid valve, (except control box options No. 0 and 1) and... with... (specify battery or hardwire) Engineer/Architect Approval with... (add spout required) with... (add outlet required) Model Specified: with... (add control box required) Approval: with... (transformer - specify separately - See Back Page) Date: 1500T4670 Hardwire Battery Operated DESCRIPTION 1500T4 1501T4 PRODUCT NO. SPOUT & SENSOR OUTLET CONTROL BOX 0 0 0 Base Model with Surface Mount Housing* SEE Specification Drawing #24 1 1 1 For RECESSED MOUNTING Components ASSEMBLED in 10" Box w/s/s Cover. * SEE Specification Drawing #25 2 Vandal Resistant 1.5 USGPM (5.7 L/min.) Laminar w/agion Antimicrobial 2 2 3 Vandal Resistant 3 1.5 USGPM (5.7 L/min.) 3 Flow Control Aerator 4 4 4 5 5 5 6 (R5) Wallmount Gooseneck Spout with Integral Sensor in Base (1) 6 6 For RECESSED MOUNTING Components & Mechanical Mixing Valve (2) ASSEMBLED in 10" Box w/s/s Cover. SEE Specification Drawing #26 7 Smooth End, Laminar Flow Control in Base of Gooseneck Spout 1.1 USGPM (4.2L/min.) 7 7 8 8 8 For RECESSED MOUNTING Components & Thermostatic Mixing Valve ASSEMBLED in 10" Box w/s/s Cover. SEE Specification Drawing #27 9 9 9 * Mixing Valve supplied by others. Flowrates are at 60 PSI. (1) Optional Spouts R3, R4, R7 and R35 only available in this series due to fixed gooseneck supplied. (2) With Thermostatic Limit Stop. Refer to www.specselect.com for individual models. Note: Use this page front and back, with specification drawing page referenced above, as product submittal sheets. Page 5.C.4.1

Approvals: CSA certified Complies to ASME A112.18.1 ADA Compliant and meets Handicapped Accessibility Standard ASME A117.1 of less than 5 lbs. handle operating force. IAPMO listed Control Box Option 6 Mechanical Mixing Valve CSA certified Control Box Option 8 Thermostatic Mixing Valve CSA certified and meets ASSE 1016 and 1017 (Contact Delta Representative for State and/or Local Approvals.) U.S. Patent #6, 826, 455. FLOW (l/min.) 9 8 7 6 5 4 3 2 1 0 0 FLOWRATE vs PRESSURE No. 2 Laminar Flow Outlet FLOW (USGPM) 2.5 10 20 30 40 50 60 70 80 Line Pressure (psig) No. 3 Aerator Outlet Flowrates Spout Outlets No. 7 Flow Control OPERATION: Hands free (touchless) operation. Water flows when sensor is activated. Water flow stops upon de-activiation of sensor. Auto shut-off feature that is selectable between 15 to 75 seconds. Factory set to 45 seconds. Will reset once obstruction is removed. Adjustable sensing distance 76 to 381mm (3" to 15") factory set to 229mm (9") (+/ 1.0 ) Low battery audible beep (for battery models only) will activate after faucet shuts off when approximately 1500 cycles remain. NOTE: For optimum performance of this product,we recommend a system pressure between 20 and 80 PSI static. This product will operate up to a maximum of 125 PSI static per ANSI and CSA requirements. However, we do not recommend pressures above 80 PSI. Thermal expansion or leaking pressure reducing valves may require use of expansion tanks or relief valves to ensure your system never exceeds its maximum intended pressure setting. GOOSENECK SPOUT ASSEMBLIES A C L Spout/Outlet mm in. mm in. mm in. Gooseneck-Standard (R5) for Outlet #2 and 3 152 6 124 4.9 188 7.4 Gooseneck-Standard (R5) for Outlet #7 152 6 117 4.6 196 7.7 2 1.5 1.5 0 Integral Sensor Electronic Wallmount Faucet 1500T4 & 1501T4 Series GOOSENECK SPOUT #6 FOR THICK WALLMOUNT INSTALLATION 1500T4670 TYPICAL INSTALLATION 1500T & 1501T ELECTRONIC FAUCET OPTIONAL ACCESSORIES: TRANSFORMERS: 060704A 110 to 24VAC Class II 20VA (Up to 5 Electronic Valves) 060771A 110 to 24VAC Class II 40VA (Up to 10 Electronic Valves) 060772A 110 to 24VAC Class II 100VA (Up to 25 Electronic Valves) CORDS: 060690A 36" Cable Extension GOOSENECK SPOUT #6 FOR THIN WALLMOUNT INSTALLATION 20" Hose Supplied (4") Tempered Water By Others 3/8" (9.5mm) Compression Adaptor Wall Thickness 12.7mm - 50.8mm (.50-2.0") 32mm (1.25") Dia. Hole Required 1/4" NPT Pipe (5" long) (4") 3/8" (9.5mm) Compression Connection 1/8''(3mm) Max. 29mm (1.125") Dia. Hole Required 90º Elbow 3/8" (9.5mm) Compression Connection OUTLET D NO. mm in. 2 18 0.69 3 18 0.69 Refer to www.specselect.com for individual models. Product supplied as shown by solid lines. All items shown by dotted lines supplied by others. DSP 1500T4

Specification Drawing #24 COMPONENTS ONLY UNASSEMBLED PRODUCT NO. VALVE TYPE COVER 1500T 4 0 Deckmount Handwash Hardwire Surface Mounted,Vandal Proof Control Housing 1501T 4 0 Deckmount Handwash Battery Surface Mounted,Vandal Proof Control Housing 36mm (1.43") VANDAL PROOF SURFACE MOUNT CONTROL HOUSING 146mm (5.73") Recommended 381mm (15" max.) to top of counter 139mm (5.47") 1/8" Allen Screw Battery Pack 3/8" Compression Connection Outlet 100mm (3.96") Inlet 3/8" NPT or 3/8" Compression Adaptor (Supplied) Note: Stainless Steel hose connection supplied between Solenoid Valve and Spout 508mm (20") S/S HOSE 89mm (3.5") MAX. 3/8" COMPRESSION FITTING BOTH ENDS Page 5.C.18.3

TEMPERED WATER - ASSEMBLED CONTROL BOX Specification Drawing #25 PRODUCT NO. FAUCET TYPE MOUNT TYPE COVER 1500T 4 1 Deckmount Handwash Hardwire Recessed Mount 305mm (12") Stainless Steel 1501T 4 1 Deckmount Handwash Battery Recessed Mount 305mm (12") Stainless Steel 127mm (5.0") 25mm (1.0") Outlet 3/8" M.I.P. 257mm (10.13") 305mm (12.0") Stainless Steel Cover Screwdriver Stop 25mm (1.0") Aluminum Control Box 127mm (5.0") Tempered Water (By Others) Inlet: 1/2" Copper (4.0") 254mm (10.0") Note: For wallhung sink installations, sensor conduit rough-in should be directly under basin to minimize sensor cord exposure. DSP 1500T4A

Specification Drawing #26 MECHANICAL MIXING VALVE ASSEMBLED CONTROL BOX PRODUCT NO. FAUCET TYPE MOUNT TYPE COVER 1500T 4 6 Deckmount Handwash Hardwire Recessed Mount 305mm (12") Stainless Steel 1501T 4 6 Deckmount Handwash Battery Recessed Mount 305mm (12") Stainless Steel 53mm (2.07") Outlet: 3/8" M.I.P. Bracket and battery holder not required for hardwire models Driver board to be located on this bracket Outlet 3/8" M.I.P. Inlets 1/2" Copper 257mm (10.13") 305mm (12.0") Stainless Steel Cover Screwdriver Stop (4.0") 254mm (10.0") Mechanical Mixing Valve with Checks and Thermostatic Limit Stop Note: For wallhung sink installations, sensor conduit rough-in should be directly under basin to minimize sensor cord exposure. Page 5.C.18.4

Specification Drawing #27 THERMOSTATIC MIXING VALVE ASSEMBLED CONTROL BOX PRODUCT NO. FAUCET TYPE MOUNT TYPE COVER 1500T 4 8 Deckmount Handwash Hardwire Recessed Mount 305mm (12") Stainless Steel 1501T 4 8 Deckmount Handwash Battery Recessed Mount 305mm (12") Stainless Steel 53mm (2.07") Outlet: 3/8" M.I.P. Bracket and battery holder not required for hardwire models Driver board to be located on this bracket Outlet 3/8" M.I.P. Inlets 1/2" Copper 257mm (10.13") 305mm (12.0") Stainless Steel Cover Screwdriver Stop (4.0") Thermostatic Mixing Valve with Checks 254mm (10.0") Note: For wallhung sink installations, sensor conduit rough-in should be directly under basin to minimize sensor cord exposure. DSP 1500T4B