Datrix, Inc NOV - 1 2005. Appendix G. 510(k) Summary of Safety and Effectiveness for Datrix, Inc CardioServer ECG Management System



Similar documents
GE Healthcare MAR

January 12, Dear Amy Yang:

JUN 2 6 butt. EkoSonicTM Endovascular System with Rapid Pulse Modulation

February 5, Dear Kristin Pabst,

Ultimate Concepts Inc.

510(k) SUMMARY MANI Needle and Suture Pack MANI, Inc.

AW Server 510 (k) Summary of Safety and Effectiveness

FEB Mr. Gordon J. Peters Director Regulatory Compliance DocuSys, Incorporated 820 S. University Boulevard, Suite 3-H Mobile, Alabama 36609

RAMSOFT BUG ,-. I"-, --I 2 N Tel: (416) Fax: (416) sales@ramsoftbiz (k) Summary

sbchoi~kku.edu jeremy~sooil.com DANA Diabecare IlS Insulin Infusion pump Infusion pump Class II

October 28, Cavex Holland Bv Mr. Richard Woortman Manager Technical Services Fustweg 5 Haarlem, 2031CJ The NETHERLANDS

kok1 UQ 510(k)J Device {Applicant 510(k) Summary (per 21 CFR (c)) OCT Applicant

DEC The three components of the Axxent Electronic Brachytherapy System include the Controller, Balloon Applicators-BR and X-ray Source.

L~l t l V~! MAY ?

510(k) Summary GlobalMedia Group, LIC. MAY CONiM

0 EC V-,) 133 Lj9a

May 7, Tactile Systems Technology Inc Daniel Chase V.P. Engineering & Operations 1331 Tyler St NE Minneapolis, Minnesota 55413

Q(K SVJM~jPagelIof 3

(k)Suminary k

SECTION 5 BARDEX TEMPERATURE-SENSING FOLEY CATHETER 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS INFORMATION

Brainreader ApS February 4, 2015 C/O Mette Munch QA Consultant Skagenvej 21 Egaa, 8250 DENMARK

Manufacturing Technology, Inc.

510(K) SUMMARY. 510(k) Number KOS'00-r

August 12, Oertli Instrumente AG Ms. Karin Rohr Head of Quality Management & Regulatory Affairs Hafnerwisenstrasse 4 CH 9442 Berneck Switzerland

February 22, Life Spine, Incorporated Mr. Randy Lewis General Manager 2401 West Hassell Road, Suite 1535 Hoffman Estates, Illinois 60169

University of Texas Medical School at Houston. April 14, 2015

SUMMARY OF SAFETY AND EFFECTIVENESS for Powered Muscle Stimulator

MAR (k) SUMMARY OF SAFETY AND EFFECTIVENESS (21CFR ) 1. DATE PREPARED: 4/21/2008

BMR ~131o-lvleccai Kesearcn Ltd.

DICOM Grid, Inc. January 25, Senior Consultant Biologics Consulting Group, Inc. 400 N. Washington Street, Suite 100 ALEXANDRIA VA 22314

(k) SUMMARY DEC

Koqo8 go. ER35 ERO-SCAN Pro Hearing Test System. 61 Martin Lane Elk Grove Village, IL Manager of Instrumentation Products

510(k) Summary. Dentsply Implants. April 30, 2013

DEC V,(9/azO (c 0 j

MAY SECTION VIII. 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS

April 3, Dear Autumn Liu,

I~r it NOV SIE T AENCORE Tongue Suspension System OCE L_ August 3, (k) Summary. Appendix 3:

November 20, Vascular Flow Technologies Ltd. Edwin Lindsay VP of QA/RA Prospect Business Centre, Gemini Cresent Dundee DD2 1TY United Kingdom

MViAKIO. V.A hn2 ATTACHMENT I 610(K) SUMMARY. Submitter:

,11 DSA Cable, transducer and VS3, VS4 electrode, patient connector

IQ Corporation c/o Harold G. Haines, Ph.D. President SEP 1 f 2002 South Florida BioAssociates, Inc SW 127h Street Miami, Florida

510(k) Summary of Safety and Effectiveness JUN Hip prosthesis

May 5, Dear Mr. Courtney:

510(k) Summary (c)

510(K) SUMMARY [as required by section (c)] FLIGHT 60 Ventilator 510(k) Number K IaO?2Z, JUL

W~c f-t. MAR 2 1 2fl09SC. 5 10(k) summary TRACTION MASTERS, INC. Traction Masters, Inc. AKA: Spinetronics, LLC 9737 NW 65 PL Parkland, Florida 33076

July 24, Dear Ms. Rhodes:

ATLANTIS Anterior Cervical Plate System ATLANTIS Translational Plate. 510(k) Summary. February 2007

51O(K) SUMMARY: Therapy family of devices.

OCT 18 20U5Ibko. a. Submitter Name: Cosmetic Dental Materials Inc. (CDM Inc.) b. Submitter Address: 812 Water St. NE Albany OR 97321

Building 6, Suite 300 RyeBrook, NY C-ontact-N~ame: --- William H-. Schofield Director of TeleHealth Operations. Signal,_Radiofrequency

Simpler Implant Solutions Inc Arbutus St. Vancouver, BC V6i 3Y9. haroldbergmanl~ogmail.com Telephone Fax K080115

EM GR.OUF DIPLOMAT. OT39?1 Company Name: (K)SUMMARY Oc. Submission Correspondent. Emergo Group, Inc. Company Address:

March 20, Dear Mr. Chen:

foq8 510(k) Summary fo r PAIRIETEX ~ COMPOSITE Mesh

510(K) Summary K102148

D I Z1. 510(k) Summary. Section 5. Siemens Medical Solutions USA, Inc. Oncology Care Systems. Date Prepared: September 09,

Fresenius Medical Care

Lewis Ward L.W. Ward and Associates, Inc Kirkwood Court Boulder, CO

510(k) SUMMARY. OPTION-vyM Urinary Catheter

AgaMatrucx. NV2 21 Salem, NH oz (k) Sumnmary

510(k) SUMMARY APR Date: 15 th December 2008

Dental Morelli Ltda.

Section 5-510(k) Summary. This document is provided in the following pages. DEC

2. Contact Person: Garo Mimaryan, MS., RAC 7 Technical Regulatory Affairs Specialist III 3. Phone Number: (914)

ItP. Section I. 510(k) Summary of Safety and Effectiveness. Applicant:

KIZ 2,33-3 p8 ~ 510(k) Summary. As required by 21 CFR (c) 510(k) Premarket Notification Submission AFrame Digital MobileCare Monitor.

March 3, Dear Ms. Alice Gong,

March 31, Etiometry, Inc. Richard Galgon Independent Consulting Associate Quintiles 5846 Cobblestone Lane Waunakee, Wisconsin 53597

August 21, TCM Associates Ltd Mr. Iain Alligan Technical Director 3 Hillgrove Business Park Nazeing Road Essex EN9 2HB United Kingdom

Phoenix Thera-Lase Systems, LLC Ms. Diane Rutherford Ken Block Consulting 1201 Richardson Drive, Suite 280 Richardson, Texas 75080

JN (k) Summary Device Identification: Device Description:

Dear Ms. Lucas: This letter corrects our substantially equivalent letter of February 18, 2016.

September 17, Keeler Instruments Inc. Mr. Eugene R. Van Arsdale Marketing Manager 459 Parkway Broomall, PA 19008

April 7, Acclarent, Inc. Mr. James Patrick Garvey II Sr. Manager, Regulatory Affairs 1525-B O'Brien Drive Menlo Park, CA 94025

June 9, Stryker Corporation Garry T. Hayeck, Ph.D. Senior Regulatory Affairs Specialist 2 Pearl Court Allendale, New Jersey 07401

I C 5 5l v ri 510(K) SUMMARY. Prowess Panther

Ad-tech Medical Instrument Corporation. Principal Consultant Quality & Regulatory Associates, LLC. 800 Levanger Lane. Stoughton, Wisconsin 53589

May 22, Rachel s Remedies, LLC Mrs. Rachel E. Jackson 2316 Delaware Ave. #174 Buffalo, New York 14216

J UN (k) SUMMARY AS REQUIRED BY SECTION (C) Mrs. Mitsuko Yoneyama President. Submitted by:

510(k) Summary. Atlanti STM Abutment and AtlantisTM Crown Abutment in Zirconia for Dentsply Ankylos Implant

September 25, Dear Ms. McCoy:

Food and Drug Administration 5 10(k) Notijfication - Partial & Total Ossicular Replacement Prostheses AUG I June 30, 2006

510(k) SUMMARY JUL Otoharmonics 0 Levo 9 System

November 17, Nanova Biomaterials, Inc. Mr. Andrew Ritts Senior Research Scientist 3806 Mojave Ct Columbia, Missouri, 65202

Ni Hau Industrial Co., Ltd. Ms. Lyn Chiu Sales Manager No. 15, Alley 125, Lane 318, Section 2, An Ho Road Tainan City, Taiwan 70967

Medical Device Data Systems, Medical Image Storage Devices, and Medical Image Communications Devices

ELASTO-GEL MANIJKAH"O"NEY JUUjj 2. fudbthsarltvl of the wound fluid, while re~leas'ing

July 21, Dentca, Inc. c/o Mr. Claude Berthoin Denterprise International, Inc. 110 East Granada Blvd, Suite 207 Ormond Beach, Florida 32176

MAY Attachment (k) Summary 21 CER

October 29, Dear Ms. Hartnett:

510(k) Summary SUBMITTER'S NAME, ADDRESS, TELEPHONE NUMBER, CONTACT PERSON, AND DATE SUMMARY PREPARED:

Summary of Safety and Effectiveness

May 20, Ivoclar Vivadent Ag Ms. Donna Hartnett Director Regulatory Affairs Ivoclar Vivadent, Inc. 175 Pineview Drive Amherst, New York 14228

r5 73~ 9/ / 510(K) Summary (K) SUMMARY

March 23, Vision Quest Industries, Inc. Mr. Mohammed Ouerghi Director of QA/RA 1390 Decision Street, Suite A Vista, CA 92081

Section (K) Summary. Kimberly-Clark Corporation Winchester Road Neenah, WI 54956

Medical Devices; Cardiovascular Devices; Classification of the Esophageal Thermal Regulation

CDRH Regulated Software

510(k) Summary May 7, 2012

Transcription:

Appendix G NOV - 1 2005 510(k) Summary of Safety and Effectiveness for CardioServer ECG Management System 1. DATE SUMMARY PREPARED: 9-26-2005 2. SUBMITTER'S NAME AND ADDRESS: Linda Gluckman 340 State Place Escondido, CA 92029 3. CONTACT PERSON: Linda Gluckman Datrix QA Manager 4. DEVICE NAME: Proprietary (trade) Name: Datrix CardioServer ECG Management System Common Name: ECG Management System Classification Name: Programmable Diagnostic Computer/ 870.1425 Product Code: DQK Class: II 5. PREDICATE DEVICE: The legally marketed device/s to which equivalence is being claimed is: Quinton Pyramis ECG Management System 3303 Monte Villa Parkway Bothell, WA 98021 K032038 Datrix CServer 510(k) Summary Appendix G 1iJ4

K o S Zegs Appendix G 6. Device Description: CardioServer ECG Management System is a software only EGG management database that stores, displays, and prints high resolution EGG data transferred from a Datrix Cardlo WiFi electrocardiograph device. All EGG records are associated by patient ID, and a final record including physician interpretation can be created. The software system analyzes data using an EGG analysis algorithm developed under direction of Dr. Peter MacFarlane, University of Glasgow (note: the same algorithm is contained in the predicate device to which equivalency is being claimed). The EGG display is able to show 1, 3, or 12 leads at once, full disclosure, user-selected strips, and interpretations editable by physician. Hardware requirements: are Windows 2000 or 2003 Server operating system; Pentium IV, 2GHz (minimum); 512 MB RAM (minimum); 10/1 00 Ethernet (minimum); RAID 5 storage; 1024x768 monitor; and standard back-up technology. 7. INTENDED USE: The GardioServer EGG Management System software is intended to be marketed to medical professionals and for point-of-care use. The software is designed to work with EGG Management databases located through out the medical community that commonly store, retrieve, display, edit, and print high-resolution records of EGG data received from devices such as the Datrix Cardio WiFi electrocardiograph. The CardioServer EGG Management System software allows medical professionals responsible for the diagnosis and treatment of patients (adult and pediatric) with heart disease to do the following: 1. Review specific patient ECG data which is available through on-screen display, printer, email, fax, or Hospital Information System (HIS) results which report by interface or other customized data bases. 2. Analyze EGG data using calipers for measurement of various intervals. The GardioServer system does not modify the original EGG waveform information, but it does provide an automated EGG interpretive analysis of the data. The EGG data display can show 1, 3, or 12 leads at once, full disclosure, user-selected strips, interpretations (editable by physician), and lists studies using various filters (study type, patient, etc.). Resulting ECG records are Datrix CServer 5 10(k) Summary Appendix G 219

13o tvs3 Appendix G all associated by patient ID and include the physician interpretation. 8. NON-CLINICAL TESTS USED IN DETERMINATION OF SAFETY: The substantial equivalence of the Datrix EGG Management System is Demonstrated by the following non-clinical testing: * Testing to the FDA Guidance Document: General Principles of Software Validation; Final Guidance for Industry and FDA Staff. * Testing for the performance, functionality, and reliability characteristics of the software device followed established test procedures in a quality system. 9. CONCLUSIONS FROM NON-CLINICAL TESTING: Datrix's CardioServer EGG Management system meets the FDA Guidance Document: General Principles of Software Validation; Final Guidance for Industry and FDA Staff with acceptable results, demonstrating substantial equivalence. 10. Technological Comparison with Predicate: Both systems: * Receive EGGs via wireless LAN, LAN, USB2, and other standard transmission modes; * Store, archive, and display EGGs; * Export EGGs in industry standard formats to electronic health records; * Print EGGs; * Utilize Windows standards; * Are delivered as software only system; * Provide secure access to patient health information; * Log all interaction with patient health information; * Provide clinical access to EGG data across the users network; * Utilize the University of Glasgow EGG Algorithm for data interpretation; * Utilize the University of Glasgow EGG Algorithm for serial comparison of EGGs; * Allow user editing of ECG interpretation; * Provide EGG measurements; * Gontain calipers for user edit of EGG measurements; * Generate management reports such as departmental EGG volume. Datfix CServer 5 1 0(k) Summary Appendix G3 3I

~ot& 2rf3 Datrix CServer 5 10(k) Summnary Appendix G 4 *1

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food andbrug Administration 9200 Corporate Boulevard Nov - 1 2005 Rockville MD 20850. c/o Mr. Mark Job Regulatory Technology Services, LLC 1394 25 th Street NW Buffalo, MN 55313 Re: K052883 Trade Name: Datrix CardioServer ECG Management System Regulation Number: 21 CFR 870.1425 Regulation Name: Programmable Diagnostic Computer Regulatory Class: Class II (two) Product Code: DQK Dated: October 10, 2005 Received: October 13, 2005 Dear Mr. Job: We have reviewed your Section 5 10(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class Ill (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 2 1. Parts 800 to 898. In addition. I DA ma' publish further announcements concerning your device in the Federal Register.

Page 2 - Mr. Mark Job Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 ). please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda. gov/cdrh/industry/support/index.html. Sincerely yours, Enclosure Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health

Appendix E Indications for Use Statement 510(k) Number (if known): KStaM3 Device Name: Datrix ECG Management System Model: Datrix CardioServer Indications for Use: The CardioServer ECG Management System software is intended to be marketed to medical professionals and for point-of-care use. The software is designed to provide a database used through out the medical community to store, display, edit and print high resolution ECG data received from devices such as electrocardiographs. The CardioServer ECG Management System software allows medical professionals responsible for the diagnosis and treatment of patients (adult and pediatric) with heart disease to: review and edit specific patient ECG data including intervals such as QT measurements and algorithm generated preliminary interpretative statements. ECG records are all associated by patient ID and other demographic data. Secure access to the database is provided. Prescription Use X Over-The-Counter Use (Part 21 CFR 801 Subpart D) (21 CER 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) $rslq'f -,,on of Cardiovascular Devices ) Number AY>x&&i5 1/I