Energy Monitoring and Control System Local and multi-site energy management solutions ENERGY MANAGEMENT AND BUILDING AUTOMATION NHP Electrical Engineering Products Pty Ltd AUS NZ 1300 NHP NHP 0800 NHP NHP nhp.com.au nhp-nz.com
Connect now and plan for tomorrow... The VMU-C energy management evolution Manage peak demand and implement an energy plan that works for you Reduce your running and maintenance costs Achieve better returns and higher occupancy Protect your assets and improve your capital value Attain longer lease terms 2
Scalable Energy Management Solutions for Local and Multi-site Applications Multi-Site Energy Management VMU-Y Embedded Energy Management pg 7 OR EM 2 -Server Cloud based energy management software pg 7 Modbus TCP, FTP, HTTP EM 2 -Server Site 1 (or Zone 1) Site 2 (or Zone 2) Site 3...Site N (or Zone 3... Zone N ) Local Site/ Zone VMU-C VMU-C Webserver Master pg 4 I/O Modules RS485 COM1 RS485 COM2 RS485 Modbus (up to 32x devices) Remote I/O Modules Energy Meters Pulse Pulse Acquisition Module Pulse Field Device Level Energy, Gas and Water Meters Also other energy measuring field devices i.e. energy meter circuit breakers, PFC controllers, VSDs and so on Remote connection of VMU-O and VMU-P modules Water Gas 3
Energy Management Controller VMU-C The VMU-C Energy management controller is the ideal web-server based solution for monitoring small to medium size installations. Gathering data from energy meters, power analysers and VMU series I/O modules (refer below), the VMU-C provides an easy to use monitoring system assisting organisations to optimise their energy and resource consumption and achieve good industry efficiency ratings such as NABERS and Green Star. With its integrated machine to machine (M2M) functionalities it is capable of automatically transferring data via FTP, HTTP or MODBUS/TCP to a remote server where a SCADA, BMS or other specific database software is running. By combining VMU-C with VMU-Y or EM 2 -Server, the end user has the ability to remotely manage multi-site installations (more detail on the following pages). VMUCEMAWSSUX An integrated Wired Web-Server Solution Since plant data is very important, VMU-C dedicates 4 GB of memory to secure data storage. VMU-C provides also a micro SD slot (up to 32 GB SDHC cards) and a hot-swap USB interface (for direct memory stick connection) on the top of the unit for: Plant configuration backup and restore; Plant database backup and restore The Ethernet interface allows to operate and configure the VMU-C, by means of LAN or direct connection to a PC, thanks to the integrated web-interface. In the case Ethernet cannot be accessed, the mini USB can be connected to a PC. Memory Advantages of the VMU-C Onsite Database No need for a dedicated PC for monitoring No crash problems which lead to data loss No compatibility problems due to different operating systems, different languages, libraries, etc Polling device, datalogger, Ethernet gateway all available in a single compact unit Modular concept for additional input/output whenever needed Ordering Information Description Webserver master unit 12-28V DC Ethernet USB RS485 Catalogue No. VMUCEMAWSSUX Ethernet and Mini USB 4
VMU Series Optional Modules Additional signalling modules can be added easily and quickly to the VMU-C control unit, either connected directly to the local bus or remotely connected via the VMU-M master unit. Application examples of where these modules are best suited include: Remote signalling when event or alarm is triggered on the VMU-C control unit Temperature and other analogue measurements Event/Alarm signalling to the VMU-C General speed/flow measurements Model Description Modules Combination Connected to the RS485 Port Catalogue No. VMU-M VMU-P VMU-O VMU-M VMU-P Master module and data logger Required when using VMU-P and VMU-O modules Environment variable module Two temperature inputs, 1 analogue input and 1 pulse rate input 1 ) 10 2 ) VMUM4XS1T2EM MAX 1x per VMU-M VMUP2TIWXSEM VMU-O I/O unit Two digital inputs and two relay outputs managed by the VMU-C or VMU-M unit MAX 3x per VMU-M VMUOXI2R2EM 1 ) VMU-P does not count pulses. Pulse aggregator D4CR12 or meter with pulse aggregator function such as EM24DIN should be used if required 2 ) VMU-M connects to RS485 port COM1 should be used if required Example Architecture of VMU-C connected to VMU modules and energy meters Webserver display VMU-C local bus array RS485 (COM1) RS485 (COM2) VMU-M local bus array Up to 10x VMU-M arrays per VMU-C Field measuring devices Up to 32x devices per VMU-C 5
Examples of Embedded Webserver Dashboards By simply opening your internet browser and logging into your VMU-C via the IP address, a number of pages are available to analyse and monitor the information recorded. The home page provides a dashboard containing: Energy consumption information (active and reactive power and energy); Cost information (yearly, monthly and daily expenses); Instantaneous 3-phase variables of the plant (voltages and currents); Graph comparing present day to previous days total energy consumption Refer below image for example From the home screen, the user can easily navigate to other pages including: Monitor page: Displays instantaneous variables on a daily, monthly or annual basis. The variables can be monitored by specific set points. In the case of problems or faults, it is possible to analyse the plant s history before the event, so as to understand the relevant reasons and act accordingly. Plant page: All the real-time variables of any meter can be displayed in this section. This is very useful for confirming meter operation and fault diagnosis. Economy page: The consumption of each energy meter can be analysed on a daily, monthly or annual basis. In the same section information acquired by pulses from the gas, water or remote heating meters, and also the analogue and environmental variables acquired by the VMU modules, can be displayed and analysed. Export page: The database, including all the history of the plant, can be accessed to get a set of data in a defined time period. The data is then available in Excel compatible format for further analysis by the user. VMU-C Webserver home page 6
Scalable Multi-site Energy Management Solutions A single centralised energy management database is possible with the VMU-Y or EM²-Server options available from NHP. Ideal for applications involving monitoring many different zones and different site locations, information recorded by the multiple VMU-C control units is easily accessible by users from any location simply by using a standard web-browser. More comprehensive data exporting is available from both the VMU-Y and EM²-Server packages with any variable from any connected meter exportable Multi-site Energy Management OR (cannot combine VMU-Y & EM 2 -Server) VMU-Y (connects up to 10x VMU-C) Modbus TPC, FTP, HTTP EM 2 -Server (connects up to 100x VMU-C) Site 1 (or Zone 1) Site 2 (or Zone 2) Site 3...Site N (or Zone 3... Zone N ) Local Site / Zone VMU-C I/O Modules RS485 COM1 RS485 COM2 RS485 Modbus (up to 32x devices) Field Device Level Remote I/O Modules Energy Meters Pulse Pulse Acquistion Module Pulse Water Gas 7
Embedded Solution VMU-Y The VMU-Y can connect to 10x VMU-C control units collating all the information to one centralised database. The VMU-Y is embedded within a compact 2-DIN module hardware similar in appearance to the VMU-C control unit, providing a comprehensive multi-site energy management database. There is no need to install any software, with quick and easy connection to the VMU-C control units. Examples of VMU-Y dashboards are described on the folowing page. Ordering Information VMUCEMAWSSUX Description Web server data concentrator unit Catalogue No. VMUYEMAWSXUX Cloud Based Solution EM²-Server The EM 2 -Server is a software solution provided as a virtual machine to be hosted in the cloud, either in the customer s facility or in a hosting farm. With the ability to connect to 100x VMU-C control units, (i.e. maximum of 3200x measuring field devices), the EM 2 -Server packages also includes an additional feature of a synoptics page, useful for visually showing the layout and locations of the connected meters. Combining the EM 2 -Server software with an industrial PC, NHP can provide a ready to go energy management solution. EM 2 -Server (connects up to 100x VMU-C) Basic PC Requirements CPU (minimum) RAM (minimum) Free disk space (minimum) Host operating system 64 bit (AMD Opteron / Intel Itanium) 8GB According to portfolio size (4GB for the bare virtual machine) Suggest at least 64GB VMWare compliant Ordering Information please contact NHP 8
Examples of VMU-Y and EM 2 -Server Dashboards Multiple Screen, Multiple Views Em 2 -Server s web interface allow users to match the needs of control rooms, by allowing the simultaneous displaying of different charts and information on the same monitor of on same screens. Position and size of the desired displaying tools can be saved for later use. Multi-site Information Management By using the Map and Navigator tools it is possible to locate information from distributed installations with ease, according to user s access rights. Present or historical values and charts are displayed according to the selected parameters and filters. Devices Status and Installations Alerts Monitoring Dedicated tools allow users to immediately check if any abnormal situation or unexpected condition is affecting the monitored plants and the monitoring devices. Distributed VMU-C EM units can be surfed via VPN and commands may be broadcasted to pools of units. Tariff Profiling Multiple tariffs may be set, splitting days in hourly slices, and defining calendars based on different daily profiles according to company needs: monthly cost reports are available as XLS files based tarrifs and real consumption data. Synoptics (only available on EM 2 Server) It is possible to create synoptic views as combinations of maps, diagrams, schematics and live icons representing the desired meters. Load Profiling The load profile tool allow statistical calculation of consumption in the single demand interval for the chosen interval of analysis. It is possible to estimate the typical daily consumption profile according to the desired confidence ratio. 9
Features Matrix Used in conjunction with VMU-C VMU-C VMU-Y EM 2 -Server Catalogue No. VMUCEMAWSSUX VMUYEMAWSXUX * Group Feature Single installation Yes Yes Yes Installation type and scalability Multiple installations No Yes Up to 10 x VMU-C EM Number of meters 32 320 3200 Yes Up to 100 x VMU-C EM Form factor 2-DIN 2-DIN Virtual machine User management User and admin profiles (multiple users) Access rights management at instrument level Yes Yes Yes No Yes Yes Online help Yes Yes Yes Variable monitoring Yes Yes Yes Custom trend analysis tool Yes Yes Yes Variable monitoring Virtual main meter management Free virtual meter management Yes Yes Yes No Yes Yes Synoptic tool No No Yes Excel data export Fixed Free Free Tariffs and costs Alarms management Tariff profiles 2 Free Free Custom calendars No 1 Free Dedicated web-view Yes Yes Yes E-mail Yes Yes Yes VMU-C remote management Remote broadcast commands via web interface N/A Yes Yes * Please contact NHP 10
TECHNICALLY FOCUSED, INDUSTRY EXPERIENCED NHP TECHNOLOGY SPECIALIST GROUP Call on the NHP TSG for your energy management and building automation solutions needs. We can help implement solutions to maximise production value, optimise performance and minimise downtime. With the optimal balance of knowledge and experience, NHP s newly created Technology Specialist Group (TSG) offers customers exclusive access to leading experts within our industry. The result? Value-add product and application support that helps deliver the best possible solution for customers and their projects. Scan the QR Code to request a call-back from one of our TSG members!
For more information, scan to download the NHP ecatalogues App offering exclusive video content, catalogues and literature! AUSTRALIA nhp.com.au SALES 1300 NHP NHP FAX 1300 NHP FAX NEW SOUTH WALES Sydney 30-34 Day Street North Silverwater NSW 2128 Tel +61 2 9748 3444 QUEENSLAND Brisbane 16 Riverview Place Murarrie QLD 4172 Tel +61 7 3909 4999 NEW ZEALAND nhp-nz.com SALES 0800 NHP NHP FAX 0800 FAX NHP VICTORIA Melbourne 43-67 River Street Richmond VIC 3121 Tel +61 3 9429 2999 Laverton 104-106 William Angliss Drive Laverton North VIC 3026 Tel +61 3 9368 2901 Albury / Wodonga 847 Ramsden Drive Albury NSW 2640 Tel +61 2 6049 0600 Fax +61 3 6025 0592 Dandenong Unit 1/80 Monash Drive Dandenong South VIC 3175 Tel +61 3 8773 6400 Fax 1300 647 329 TASMANIA Hobart 29B Lampton Ave Derwent Park TAS 7009 Tel +61 3 6228 9575 Fax +61 3 6228 9757 Launceston Unit 3 13-17 Merino Street Kings Meadows TAS 7249 Tel +61 3 6345 2600 Fax +61 3 6344 6324 Newcastle 575 Maitland Road Mayfield West NSW 2304 Tel +61 2 4960 2220 Fax +61 2 4960 2203 Wollongong Unit 3 1 Resolution Drive Unanderra NSW 2526 Tel 1300 647 647 Fax 1300 647 329 ACT Canberra Unit 1 187 Gladstone Street Fyshwick ACT 2609 Tel +61 2 6280 9888 Fax +61 2 6280 9588 WESTERN AUSTRALIA Perth 38 Belmont Ave Rivervale WA 6103 Tel +61 8 9277 1777 NORTHERN TERRITORY Darwin 3 Steele Street Winnellie NT 0820 Tel +61 8 8947 2666 Fax +61 8 8947 2049 Townsville 5 Leyland Street Garbutt QLD 4814 Tel +61 7 4779 0700 Fax +61 7 4775 1457 Rockhampton 1 Lawson Street Parkhurst QLD 4702 Tel +61 7 4927 2277 Fax +61 7 4922 2947 Toowoomba Cnr Carroll Street and Struan Court QLD 4350 Tel +61 7 4634 4799 Fax +61 7 4633 1796 Cairns Unit 2 1 Bramp Close Portsmith QLD 4870 Tel +61 7 4035 6888 Fax +61 7 4035 6999 SOUTH AUSTRALIA Adelaide 36-38 Croydon Road Keswick SA 5035 Tel +61 8 8297 9055 PO Box 62-009 Sylvia Park Auckland 1644 New Zealand Auckland 118a Carbine Road Mt Wellington 1060 Hamilton 78 Rostrevor Street Hamilton 3204 Napier 126 Taradale Road Onekawa 4110 New Plymouth 2 Dean Place Waiwhakaiho 4312 Wellington Unit B4, 59 Marsden Street Melling Lower Hutt 5010 Christchurch 27 Iversen Terrace Waltham 8011 Dunedin 30 Fox Street South Dunedin 9012 NHP Electrical Engineering Products Pty Ltd A.B.N. 84 004 304 812 NEMCSC 2/16 Copyright NHP 2016